If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date22 Oct 2024
Closing Date11 Nov 2024
Tender Amount₹ 86,33,000 
Notes
Download

Costs

  • EMD

    ₹ 1,72,660
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

11475

11

126225

... More
Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades.) ; Mechanical method using Penetration grade Bitumen VG - 30 and HMP of appropriate capacity not less than 75 tonnes/hour .

11475

98

1124550

... More
Seal Coat (Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats) Case - III : Type C Providing and laying of premix seal coat with HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping 6.7 mm size and penetration bitumen of suitable grade. (Aggregate 0.09 Cum / 10 Sqm , Bitumen 4.5 %) Bitumen VG - 30

11475

54

619650

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )

32.18

5409

174061.62

... More
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)

0.54

15488

8363.52

... More
Providing and Erecting typical Mukhya Mantri Sadak Yojana signboard made of two MS sheet of 1.6 mm thick each of size1500 mm x 600 mm and 1200 mm x 150 mm stiffened by angle size 25 mm x 25 mm 3 mm all around the plate and plates welded to each other at two places and assembly of plates fixed on tubular frame of 70 mm x 70 mm 12 SWG sheet Square tube ( vertical post 2500mm with angle holdfasts ) .On the top of 1200x150 mm a circular sheet of 900 mm dia to be fixed as per drawing showing Road logo & name of scheme " Mukhya Mantri Sadak Yojana ".Board duly embeded in cement concrete M-15 grade of block of 300 mmx 300 mm x 600 mm size below ground level .All MS will be stove enameled on both side. Lettering , figuring and border will be with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed post and steel tube will be painted with primer and two coat of epoxy paint as per drawing .

1

8701

8701

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil. Mechanical Means. Depth upto 3 m

380.67

51

19413.93

... More
Ordinary rock (not requiring blasting) Depth upto 3 m depth.

107.92

388

41872.34

... More
Hard rock (blasting prohibited) Manual Means

107.92

514

55470.06

... More
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)

102.9

3938

405216.26

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications PCC Grade M20

235.38

4949

1164895.62

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC Grade M20 Height upto 5m

348.81

5235

1826034.07

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications PCC Grade M15

104.85

4508

472663.8

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M25. Using Concrete Mixer For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m

110.6

6181

683601.69

... More
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications

10.15

90000

913516.49

... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications

1.03

89524

92630.48

... More
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.

1800

155

279000

... More
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification. Boulder laid dry without wire crates.

42

1322

55524

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification Granular materia

390

663

258570

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

68

128

8704



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.