Public Works Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date5 Apr 2023
Closing Date7 Jun 2023
Tender Amount₹ 11,84,00,000 
Notes
Download

Costs

  • EMD

    ₹ 23,68,000
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 2,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthwork in excavation in ordinary rock, including stacking / disposal of surplus Material exclusive of compensation of earth (MoRTH specification : clause 301 to 305). By Hydraulic Excavator CK-90 of 0.9 cum bucket capacity and tipper with disposal upto 1000 mtrs.

9073.78

308508

34

... More
Earthwork in excavation for roadway in hard rock, including stacking / disposal of surplus Material exclusive of compensation of earth (MoRTH specification : clause 301 to 305). Requiring blasting

1814.76

313953

173

... More
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material up to a lead of 1000m including removal and disposal of top organic soil not exceeding in 150 mm thickness as per MoRTH specification clause 201

5.35

92052

17206

... More
Dismantling of flexible pavements and disposal of dismantled Materials upto a lead of 1000 mtrs. Stacking serviceable and unserviceable Materials separately. (MoRTH specification : Clause 202).BY MECHANICAL MEANS.Bituminous Courses

1120

184800

165

... More
Scarifying, including picking up scarified Material and stacking of old serviceable Material within a lead of 1000 meter [MoRTH Specification: Clause 202 & 305.4.3]. Stone metal crust – 50 mm to 100mm thick by power driven scarifier alongwith 20mm premix carpet/surface dressing with all lift and lead upto 1000m for reusable Materials.

47600

628320

13.2

... More
Providing, laying and spreading and compacting specified graded crushed stone in sub-base course including premixing the Material at OMC in mechanical mixer (Pug mill), carriage of mixed Material, laying in uniform layers with Motor Grader, F.E. Loader, on a prepared surface and compacting with Vibratory Compactor to achieve the desired density including all Material, labour, machinery, lighting barricading and maintenance of Driversion complete. (MoRTH specification clause 401). with all lead & lift Including 1 km lead

4032.99

3419975

848

... More
Providing, laying, spreading and compacting crushed graded stone aggregate as per Table 400-10 & 400.11 to Wet Mix Macadam specifications including premixing the Material with water to OMC in mechanical mixer (Pug mill) as per design mix, carriage of mixed Material by tipper to site laying in uniform layers, with motor grader/F.E. loader/Paver Finisher, in sub-base/base course on a well prepared under-base and compacting with Vibratory Roller to achieve the desired density including lighting, guarding, barricading and maintenance of Driversion etc. (MoRTH specification : Clause 406). with all lead & lift . By mechanical means with lead upto 10 km

6841.51

7247211

1059.3

... More
Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS:8887 & manufacturer’s specifications @6 kg/10 sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification : Cl. 502, 112 Add extra to above item per 1 kg extra in emulsion per 10 sqm

29320.5

853226

29.1

... More
Providing and applying tack coat on the prepared surface, with bitumen emulsion as per IS:8887 & manufacturer’s specifications @0.2 kg/sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification Cl. 502, 112.

90775.5

718034

7.91

... More
Providing and applying tack coat on the prepared surface, with bitumen emulsion as per IS:8887 & manufacturer’s specifications @0.2 kg/sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification Cl. 502, 112. (a) Add extra for above item per 0.1 kg extra in emulsion per sqm

90775.5

1056626

11.64

... More
Providing and laying Dense Bituminous Macadam on prepared surface with specified graded crushed aggregates (as per table 500-9, 500-10 and design mix) for base/binder course including loading of Material with F.E. loader, heating of binder (including cost of anti stripping compound, wherever required) aggregates and filler in hot mix plant (40-60 TPH), transporting the mixed Material by tippers and laying with sensor paver finisher as per clause 504.3.5 to the required level and grade, rolling by self propelled power rollers and vibratory rollers or pneumatic tyred roller, 150-250 KN. TP=0.7 Mpa, to achieve the desired density (approved by the department) but excluding primer/tack coat. (MoRTH specification : clause 505, 112). with all lead & lift (a) 50-75mm compacted thickness with 4.5% bitumen content VG30 grade with lead of mixed Material 1 km

4538.78

30269123

6669

... More
Providing and laying Bituminous Concrete as per Design Mix on prepared surface with specified graded stone aggregates as per Table 500-17, for wearing course including loading of aggregates with F.E. loader and hot mixing of binder (including cost of anti-stripping compound, wherever required) and 3% cement filler with aggregates in Hot Mix Plant 40-60 TPH, transporting the mixed Material with tipper to paver and laying with sensor paver finisher (as per clause 504-3.5) to the required level, grades and rolling with vibratory compactor and pneumatic tyred roller 150-250 kN, TP = 0.7 Mpa, to achieve the desired density (approved by the department as per job mix) excluding cost of primer/tack coat. (MoRTH specification : clause 507). 30-45mm compacted with 6% binder with lead of mix Material 1 km With straight run bitumen grade VG30

2723.27

21146191

7765

... More
Earth work in excavation, including stacking/disposal (MoRTH specification : clause 301 to 305). By Hydraulic Excavator CK-90 of 0.9 cum bucket capacity and tipper with disposal upto 1000 mtrs.

500

13000

26

... More
Providing and Laying cement concrete 1:4:8 in sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trail length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing as per MoRTH specification : Clause No. 601, 112. By mechanical means with lead upto 20 km

1076

2376884

2209

... More
Providing and Laying un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures and vacuum processing pump as approved, curing compound, finishing to lines and grades as per drawing as per MoRTH Specification : Clause No. 602, 112. Using Cement concrete M-30 pavement Grade

1815.6

8800213

4847

... More
Providing and fixing of precast concrete interlocking blocks of 80mm thick (M-30 Grade) manufactured from fully computerized automatic stationery hydraulic vibto perssed machine & full computerized automatic batching plant of class A-I as per BS: 6717-2001. The CC interlocking paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compected sub base as defined. The work includes earth work in cutting of B/T road, cutting of WBM road and disposal of unserviceable Material with all leads & lifts and stacking of serviceable Material complete job is to be executed as per the instructions of Engineer-in- charge. The rates to be inclusive of all lead, lifts & taxes General specification of Blocks:2. Tensile splitting strength and breaking load as per BS : 6717-2001.3. Colour : Grey cement natural colour.4. Variation in Dimension : Less than 1.6mm.5. Variation in thickness : Less than 3.2mm

9800

4615800

471

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304].

2400

136800

57

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700]. (b) Cement concrete 1:3:6 mix with stone aggregate 40 mm crusher broken

240

716880

2987

... More
.Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500].With 20mm nominal size aggregate R.C.C. M-20 grade

636.75

2557824

4017

... More
Steel reinforcement in substructure complete. [MoRTH Specification : Section 1600]HYSD reinforcement

12.74

1130509

88737

... More
Supply and fixing of Fibre - reinforced Ferro-Cement drain cover ( Light duty ) designated for class "B" loading duly marked on cover with adequate steel reinforcement having thickness 50 mm to 75 mm, anti-corrosive bitumen painted M.S. Plate Rim and on M.S. lifting hooks, additives & admixture like plasticizer, shrinkage resistance compound, abrasion resistant etc. as per approved drawing and design complete in all respect. Span 701 mm to 1200 mm Standard Size 1500 x 700 mm

200

174200

871

... More
Providing and laying Reinforced cement concrete pipes NP-4 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 500 mm Dia

120

252360

2103

... More
300 mm Dia

120

123840

1032

... More
Kilometre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc Ordinary kilometer stone (precast)

12

18012

1501

... More
Hectometer stone (precast)

44

18040

410

... More
Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting

89

33375

375

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of micro prismatic grade conforming to IRC-67: 2012 & Type XI standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al / 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor. (This shall be used only for N.H, S.H & M.S.H Roads).Regulatory sign boards of 90 cm Triangle. Size 90 cms. Triangle

30

113760

3792

... More
Providing and Fixing of Retro Reflectorised 600 x 800 mm Facility sign boards made out of retro reflective sheeting of micro prismatic grade conforming to IRC-67: 2012 & TypeXI standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al / 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor. (This shall be used only for N.H, S.H & M.S.H Roads). Regulatory sign boards of 60 x 80 cm Rectangle. Size 60 x 80 cms. Rectangle

20

93480

4674

... More
Retro-Reflectorised traffic sign Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing 80 mm x 60 mm rectangular

10

21850

2185

... More
Metal Beam Crash Barrier Type - A, "W" : Metal Beam Crash Barrier Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810

120

283440

2362

... More
Raised Pavment Marker ( Cats Eyes): Supplying and Fixing of Molded Shank Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 – DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the engineer. The contractor shall submit 2 years pre qualified warranty certificate from the manufacturer for satisfactory field performance during the time of bid submission

3500

649600

185.6

... More
Providing and Fixing of Retro Reflectorised 600 x 500 mm Chevro sign boards made out of retro reflective sheeting of micro prismatic grade conforming to IRC-67: 2012 & TypeXI standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor. (This shall be used only for N.H, S.H & M.S.H Roads).Regulatory sign boards of 60 x 50 cm Rectangle. Size 60 x 50 cms. Rectangle

120

420840

3507

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

3870.1

1579000

408

... More
Cast in Situ Cement Concrete M20 Kerb ,Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408.Using Concrete Mixer

5040

997920

198

... More
Painting Two Coats on New Concrete Surfaces.Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

1512

99792

66

... More
Street Lighting,Providing and erecting street light mounted on a steel circular hollow pole of standard specifications for street lighting, 9 m high spaced 40 m apart, 1.8 m overhang on both sides if fixed in the median and on one side if fixed on the footpath, fitted with sodium vapour lamp and fixed firmly in concrete foundation.For Fixing in Median

60

472260

7871

... More
Supply and Erection of built up Overhead structure of 12-15 M span comprising of one vertical posts of 6.00 m height made up of 300mm NB heavy class M.S. pipe as vertical member welded with 12mm plate at top and bottom for bearing of horizontal fram comprising of 65mm NB made heavy class main pipe as of 32 mm heavy class NB pipe branching as per approved design and drawing with one steel primer and two coats of synthetic enamalpaint complete the work includes with construction of R.C.C. foundation 900x900x2150 mm deep over lean concrete and including 25mm dia 750mm long foundation bolts as provision of structure including cost of reinforcement as per direction of E/E.

2

671964

335982

... More
Supply at site of work well-decayed farm-yard manure, from any available source, approved by the Engineer in charge including carriage, screening and stacking.

405

98820

244

... More
Grassing with “Doob” grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 15 cm apart in either direction.

2700

25434

9.42

... More
Supply & Planting of shady plants (Neem, Peepal, Goolar, Jamun, Imli or other specified) along road side including the following activities :- Perparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. Supply of plant at site of two years of age & height more than 1.50 Mtr Supply of dry manure (farm yard manure organic) Supply of Insecticides Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 15 liter plant after planting. Half brick Circular tree guard in second class bricks, internal dia 1.25 meter above ground and 0.20 meter below ground, and 0.20 meter below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 Cement : 6 Sand) and the intermediate courses being in dry honey comb masonry, as per design complete. Watering to plants. Maintenance of plants by the contractor including of pits/bids preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant die during maintenance contractor has to replace same height plant at his own cost.

90

99000

1100

... More
Earthwork in excavation in foundation trenches etc. in drains and channels etc. not exceeding 2m depth, including dressing of bottom and sides of trenches, stacking the excavated soil 3m clear from the edge of excavation including disposal of surplus soil as directed within a lead of 1000 metres (MoRTH specification : clause 301, 304). Ordinary soil

430.44

24535

57

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700]. (b) Cement concrete 1:3:6 mix with stone aggregate 40 mm crusher broken.

10.98

32797

2987

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500].With 20mm nominal size aggregate.P.C.C. M-15 grade

180.12

646630

3590

... More
Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 1000mm dia

90

396900

4410

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. In ordinary soil [MoRTH Specification : clause 301]BY MECHANICAL MEANS Depth upto 3m

963.48

54918

57

... More
In Ordinary/Soft rock (not requiring blasting) [MoRTH Specification : Clause 301]BY MECHANICAL MEANS

722.61

59976

83

... More
In Hard Rock [MoRTH Specification : Clause 301, 302, 303].Blasting Prohibited

80.29

53794

670

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500].With 20mm nominal size aggregate P.C.C. M-10 grade

123.9

334653

2701

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500].With 20mm nominal size aggregateP.C.C. M-15 grade

1047.04

3758873

3590

... More
Structural cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification.Design mix concrete – [MoRTH Specification : Section 1500 & 1700].RCC M-20 grade, including form work Upto 5 mtr. height

860.03

3170930

3687

... More
Structural cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification. Design mix concrete – [MoRTH Specification : Section 1500 & 1700]. RCC in M-30 grade, including form work Upto 5m height

114.93

460064

4003

... More
Steel reinforcement in substructure complete. [MoRTH Specification : Section 1600] HYSD reinforcement

27.27

2419857

88737

... More
Providing A.C. pipe Weep holes 150mm dia in Masonry/plain Concrete/Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification. [MoRTH Specification : Clause 2205].

2071.44

236144

114

... More
Providing and filling in foundation trenches, and back filling behind abutments, wing walls, return wall etc., and below pipe bed in layers not exceeding 150mm thick including watering and compacting (IRC-78) complete as per drawing and technical specifications (MoRTH specification 710 & 2200) including all lead and lifts.Selected granular Material in filling (MoRTH specification : Clause 2200).

893.15

665396

745

... More
Providing and fixing 20mm thick Compressible Fibre Board in expansion joint complete as per drawing and technical specification in MoRTH specification : clause 2605.

97.6

88328

905

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. In ordinary soil [MoRTH Specification : clause 301] BY MANUAL MEANS Depth upto 3m

585

68445

117

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700]. (b) Cement concrete 1:3:6 mix with stone aggregate 40 mm crusher broken.

43.88

131069

2987

... More
Stone masonry work in cement mortar 1:4 with mechanical mixer for foundation (any level) complete, including all scaffolding etc., excluding pointing and plastering, as per drawing and technical specification. [MoRTH specification : Section 1000, 1400] Random Rubble Masonry (coursed/uncoursed)

514.8

1464606

2845

... More
Stone masonry work in cement mortar 1:4 for substructure complete, with scaffolding, as per drawing and technical specifications [MoRTH Specification : Section 1400]. Random Ruble masonry (coursed/uncoursed)

30

80610

2687

... More
Providing A.C. pipe Weep holes 150mm dia in Masonry/plain Concrete/Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification. [MoRTH Specification : Clause 2205].

195

22230

114

... More
Plastering 20mm thick with cement mortar (1:3) on Masonry work in sub structure as per technical specifications.

15990

2222610

139

... More
Providing and laying RCC M-20 mix with stone aggregate 20mm (nominal size) mechanically mixed and vibrated for RCC work in slab in superstructure upto 4 mtr. above 1.5 mtr. level from Bed/Ground level, excluding steel reinforcement but including centering and shuttering, laid in position. (MoRTH specification : Clause 1000/1700)

7.31

33099

4528



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.