Public Works Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 8,00,000Document Cost
₹ 2,000Tender Fee
₹ 2,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPWD_424985_6Bid Award Id
ViewTender No
NIT No 10 of 2024-25 ACE ZONE I JodhpurTender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://pwd.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
FD order dated 21.10.2021 for additional performance security for unbalanced bid
BOQ Items
... More
Earth work in excavation, including stacking/disposal of surplus material with all lifts and lead upto 495 metres, exclusive of compensation of earth [MoRTH specification : Clause 301 to 305] In ordinary Soil Mechanically by power shovel, including mechanical loading and carriage by tipper/dumper (6T capacity)
4968.75
40
198750
... More
Extra for laying earth as per specification for compaction in 200 mm thick loose layers and dressing [MoRTH Specification Clause 305.3.5].BY MECHANICAL MEANS, using Motor Grader, from earth in stock piles with all lead and lift but excluding rolling and watering.
4968.75
25
124218.75
... More
Extra for rolling to specification with Power Roller, 8-10 tonne when earth is at suitable moisture content with dry field density not less than 100 % of maximum dry density (Ordi-nary Procter test).excluding watering.
4968.75
26
129187.5
... More
Extra for watering the earth to bring the earth upto required O.M.C excluding rolling
4968.75
18
89437.5
... More
Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactor to achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] a) For Grading I Material
2793.76
880
2458508.8
... More
Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactor to achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] a) For Grading III Material
990
750
742500
... More
Construction of dry lean cement concrete sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm , aggregate cement ratio not to exceed 15:1 , aggregate gradation after blening to be as per Table 600-1, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant as per mix design, transported to site, laid with a hydrostatic paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing complete as per MoRTH specification clause 601.
2639.38
2200
5806636
... More
Providing and laying controlled cement concrete for cement concrete pavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with stone aggregate (crusher broken) including anti-skid textured finish to required camber/ superelevation and grade including curing etc. as per specification with cement concrete M-40 grade
3220
5800
18676000
... More
Supplying, fitting and placing mild steel reinforcement complete in substructure as per drawing and technical specifications MoRTH Section 1600,2200.
Add for Dowel Bar & Tie Bar
2.25
85000
191250
... More
Cutting of construction joint/ longitudinal joint 4 to 6 mm. wide & 75 to 100 mm deep using mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealing compound in groove including cost of sealing compound.
6325
130
822250
... More
Providing and fixing of Precast concrete interlocking blocks manufactured and laid over a sand bed of 20 -40mm thick as per IRC SP 63-2004 and IS 15658 -2006. Complete job to be executed as per the instructions of Engineer-in-charge. The rates are inclusive of all lead, lifts & taxes 1. Shape : As specified by Engineer-in-charge.
2. Strength and breaking load as per IS:15658-2006
3. Colour : As specified by Engineer-in-charge.
4. Variation in Dimension :as per IS:15658-2006
5. Variation in thickness : as per IS:15658-2006
80mm thick, Medium traffic category, M40 Grade designation blocks
3087.5
840
2593500
... More
Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively , 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M-20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per MORTH specification Clause 409.
Using Concrete Mixer
800
435
348000
... More
Providing and laying reinforced cement concrete pipes N.P.3 for culverts including jointing ends and fixing collar with cement mortar 1:2 [MoRTH Specfication : Clause : 1000/2900] 300mm dia
250
1174
293500
... More
Providing and laying reinforced cement concrete pipes N.P.3 for culverts including jointing ends and fixing collar with cement mortar 1:2 [MoRTH Specfication : Clause : 1000/2900] 600mm dia
62.5
3026
189125
... More
Providing and Fixing 100mm thick Reinforced Ferro-Cement Drain cover with 2mm thick MS sheet frame M20 Cement Concrete and 12mm steel reinforcement @ 150 mm c/c bothway with M.S. lifting hooks.
Iii) 701 to 1200mm
240
2850
684000
... More
Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm. Layers with compaction including disposal of all surplus soil, as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304]. Pick work (Hard soil)
676
230
155480
... More
Providing and laying mechnically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level.[MoRTH Specification : Clause 1000/1700]
Cement concrete 1:3:6 mix crushed stone aggregates 20mm nominal size.
78
3800
296400
... More
providing and fixing in position precast reinforced cement concrete U-shape drain (Precast T-6) as per design and shape, using --do-- 5 T Wheel load(T-6)
400
6121
2448400
... More
Pointing with cement mortar (1:3) on stone masonry as per drawing and technical specification Clauses 1406Flush and Rulled Type
1600
200
320000
... More
Providing and erecting direction and place identification retro - reflectorised sign as per IRC:67 made of high intensity grade sheeting exclusive of lettering, border & signs fixed over aluminium sheeting, 2 mm thick fixed on a mild steel angle iron frame 50mmx50mmx6mm supported on mild steel angle iron post 75 x 75 x 6 mm upto the top of sign board, length of post from bottom of sign board is 2.85 m. upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm. wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 60 Cm , 60 Cm below ground level as per approved drawing & as per MORTH specifications clause 801. Double angle post90 cm. X 75 cm.
10
6990
69900
... More
Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 2.85m. upto foundation level post duly painted in black & white synthetic enamel. fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. 90 Cm equilateral triangle
10
4200
42000
... More
Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 2.85m. upto foundation level post duly painted in black & white synthetic enamel. fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. 60 Cm circular
10
4175
41750
... More
Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 2.85m. upto foundation level post duly painted in black & white synthetic enamel. fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. 90 cm high octagon
10
7210
72100
... More
Supply of sign boards made of 1.25mm M.S. sheet duly framed with 33.30mm OD MS black tube medium class as per IS:1239 (Part-I) 1979 with a inner support of M.S. flat 12x3mm whole structure is fixed on two posts of Black m.S. tube 42mm OD MS (Medium Class)as per IS : 1239 9Part-I) 1979 height 3 m. whole board is stove enamelled painting in Black & White alternate band of synthetic enamel. 180 cm. x 120 cm.
4
3750
15000
... More
Installation of sign boards having the posts like mandantory, cautionary and informatory boards including excavation, fixing of posts in 300 mm dia. RCC hume pipe (IS marked) 1.20 m long, 75 cm embedded in ground, the in side of pipe shall be filled with cement concrete 1 : 4 : 8 with semi-circular hump at top, the pipe shall be painted white with enamel paint including transportation etc. complete.Double post
4
775
3100
... More
Providing and laying of hot applied thermoplastic compound inclusive type I reflectrosing glass beads as per table 800-9, 800-10 applied in uniform thickness of at least 2.5 mm and spread uniformly with reflectorising glass beads type II in addition @ 250 gms per Sqm with a road marking machine as per IRC: 35 complete with traffic diversion arrangement as per MORTH specification clause 803.4.
1699.2
431
732355.2
... More
Providing & fixing Two way reflective Plastic body raised road studs with anchor with shank 100x100x19.8 special reflective elements 19 degree tilted etc. complete made by swareflex at 9 m. centre to centre on edge lenes, lane lines and 1 m. centre to centre on pedestrai crossing including fixing, cost of conveyance of all materials to site including labour and hire charges for machineries involved etc. complete as per standard specifications and directions of the Engineer-in-charge..
750
306
229500
... More
Providing & fixing of retro-reflectorised hazard marker of size 30cm. X 90 cm. As per IRC-79-1981 made of high intensity grade sheeting in the form of alternate black & yellow strip sloping down ward at an angle of 45 degree C vide clause 801.3, fixed over aluminium sheeting, 2mm thick fixed on mild steel angle frame 50mmx50mmx6mm supported on mild steel angle post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 90 cm. upto foundation level fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm.x45cm.x60cm. below ground level as per approved drawing & as per MoRTH specification clause 801.
10
2380
23800
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements