If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 3,40,000Document Cost
₹ 2,000Tender Fee
₹ 2,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPWD_426099_3Bid Award Id
ViewTender No
NIT NO 02 YEAR 2024-25 PWD CIRCLE, JALORETender Authority
Public Works Department ViewPurchaser Address
-Website
http://eproc.rajasthan.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
FD order dated 22.10.2021 for additional performance security for unbalanced bid
BOQ Items
Cement Concrete for plain/reinforced concrete in open foundation, any level, complete as per drawing and technical specifications. [MoRTH Specification Section 1700&1500] P.C.C.M15 grade
366
1477176
4036
SUB STRUCTURE Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications MoRTH Section 1400,2200.Coursed rubble masonry (first sort)
1196
4847388
4053
Providing and laying Random Rubble masonry in foundation upto a depth of 1.50 metres and 1.50 metres above Ground /Bed level.[MoRTH Specfication: Clause 1000/1400] Cement sand mortar 1:6
560
1904000
3400
Providing Cement pointing 1:2 deep variety (cut or weather) on brick, stone and tile work at all levels.[MoRTH Specfication : Clause 1000/1300]
1693
248871
147
Plain/reinforced cement concrete in substructure complete as per drawing and technical specifications MoRTH Section 1500,1700, 2200.PCC Grade M-20 Height upto 5.00m.
13
57850
4450
Plain/reinforced cement concrete in substructure complete as per drawing and technical specifications MoRTH Section 1500,1700, 2200.RCC Grade M-25 Height upto 5.00m.
77
400323
5199
Supplying, fititng and placing HYSD bar reinforcement in substructure complete as per drawing and technical specification MoRTH Section 1600,2200.
6.04
516462
85507
Providing weep holes in brick masonry/ plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and technical specifications.
132
11352
86
Furnishing and placing reinforced/ prestressed cement concrete in superstructure as per drawing and MoRTH specifications section 1500, 1600, 1700. RCC Grade M-30 Using Batching Plant, Transit Mixer and Concrete Pump.For Solid Slab Superstructure Height upto 5 m.
127
693801
5463
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRTH specification section 1600.
15
1285845
85723
PCC M-15 grade levelling course below approach slab complete as per drawing and MoRTH specifications clause 14.10.
12
48108
4009
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and MoRTH specifications section 1500, 1600, 1700, 2704.
24
191160
7965
Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and MoRTH specification section 2702.
36
324720
9020
Providing & Fixing in position 20mm thick premoulded joint filer in expansion joint complete.
72
53568
744
Providing and filling joint sealing compound -Coarse sand with bitumen (6% by weight)
72
1872
26
Providing and laying of filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in Clause 2504.2. Of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications clause 710.1.4 of IRC 78 & MoRTH section 2200.
119
89012
748
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specifications clause 710.1.4 of IRC 78 & MoRTH section 2200.Granular material
1495
811785
543
Providing and laying of compression seal joint consisting of steel armoured nosing at two edges of the joint gap suitably anchored to the deck concrete and a preformed chloroprene elastomer or closed cell foam joint sealer compressed and fixed into the joint gap with special adhesive binder to cater for a horizontal movement upto 40 mm and vertical movement of 3 mm.
72
194976
2708
Construction of precast RCC railing of M-30 grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion complete as per approved drawings and MoRTH specification 2703, 1500, 1600, 1700.
86
135192
1572
Painting two coats after filling the surface with synthetic enamel paint in all shades on plastered concrete surfaces as per MORTH specifications Cl. 803. a) New Surface
600
61200
102
Providing and laying flooring complete as per drawing and Technical specification laid over cement concrete bedding 15 cm thick as per MoRTH specification clause 2505, 1700. Rubble stone laid in cement mortar 1:3 (30 cm thick)
85
359550
4230
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 metres, stacking serviceable and unserviceable materials separately as per MORTH specification clause 202.
65
65390
1006
Dismantling upto 1.5m in foundation and/or 1.5m above ground level including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material, and stacking serviceable material with in a lead of 1000m. [MoRTH Specification clause 202] ,by mech means
-
-
-
Cement concrete grade M-15 & M-20
65
24505
377
Rubble stone masonry in cement mortar
180
40500
225
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material upto a lead of 1000m including removal and disposal of top organic soil not exceeding in 150 mm thickness as per MORTH specification clause 201 By manual means In area of light jungle
0.25
4056
16224
Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) (incl. lead upto 1000M & all lifts) Grading III
730
36500
50
Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) (incl. lead upto 1000M & all lifts) c) For Grading III Material
108
35748
331
Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in mechanical mixer (Pug mill), carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactor to achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401].
963
788697
819
Construction of dry lean cement concrete sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm , aggregate cement ratio not to exceed 15:1 , aggregate gradation after blening to be as per Table 600-1, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant as per mix design, transported to site, laid with a hydrostatic paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing complete as per MoRTH specification clause 601.
131
274576
2096
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501, Using vacuum dewatering with required machinery
336
1837920
5470
Supply of direction and place identification sign boards made out of 2mm thick MS sheet framed to angle iron 40 x 40 x 5mm and 2 vertical posts of angle iron 65 x 65 x 6mm, 4.60m long with hold fasts including excavation and fixing with CC 1:4:8 (30 x 30 x 60cm) and transportation with painting with superior grade enamel paint of approved quality including lettering and figuring etc. complete as per IRC standard size 160 x 180cm (project board)
1
7600
7600
Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 2.85m. upto foundation level post duly painted in black & white synthetic enamel. fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801.
-
-
-
90 Cm equilateral triangle
2
8572
4286
90 cm high octagon
2
13044
6522
Providing and erecting direction and place identification retro - reflectorised sign as per IRC:67 made of high intensity grade sheeting exclusive of lettering, border & signs fixed over aluminium sheeting, 2 mm thick fixed on a mild steel angle iron frame 50mmx50mmx6mm supported on mild steel angle iron post 75 x 75 x 6 mm upto the top of sign board, length of post from bottom of sign board is 2.85 m. upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm. wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 60 Cm , 60 Cm below ground level as per approved drawing & as per MORTH specifications clause 801. Double angle post. 120 cm. X 90 cm.
2
19964
9982
Supplying of men at work sign board (folding type) made on 1.25 mm thick M.S. sheet size 900x900x900mm painted in white stove enamelled paint and reflective machine cut sheet Men's emblem and letter MEN AT WORK in red colours and additional attachment of size 150x900mm plate for gang number & name with white stoving enamelled back ground, both plates are fixed on a folding stand of M.S. (heavy) steel tube of size 13.2mm , outer dia as per IS-1239 (Part-I) 1979 duly painted in gray colour and both the plates are painted on back side in gray enamel paint.
2
2110
1055
Providing & fixing of retro-reflectorised hazard marker of size 30cm. X 90 cm. As per IRC-79-1981 made of high intensity grade sheeting in the form of alternate black & yellow strip sloping down ward at an angle of 45 degree C vide clause 801.3, fixed over aluminium sheeting, 2mm thick fixed on mild steel angle frame 50mmx50mmx6mm supported on mild steel angle post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 90 cm. upto foundation level fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm.x45cm.x60cm. below ground level as per approved drawing & as per MoRTH specification clause 801.
4
9520
2380
Supply & fixing flood gauge (water gauge) as per IRC 67 standard 200cm. long fixed on angle iron post 50mmx50mmx6mm, 2.60m. Long fixed cement concrete M-15 mix size 30x30x60 cm. Complete including transportation excavation etc. complete.
2
2430
1215
Providing and laying of hot applied thermoplastic compound inclusive type I reflectrosing glass beads as per table 800-3, 800-4 applied in uniform thickness of at least 2.5 mm and spread uniformly with reflectorising glass beads type II in addition @ 250 gms per Sqm with a road marking machine as per IRC: 35 complete with traffic diversion arrangement as per MORTH specification clause 803.4.
100
52300
523
Raised Pavment Marker ( Cats Eyes): Supplying and Fixing of Molded Shank Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 – DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the engineer. The contractor shall submit 2 years pre qualified warranty certificate from the manufacturer for satisfactory field performance during the time of bid submission
150
27900
186