Public Works Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date29 Aug 2024
Closing Date17 Sep 2024
Tender Amount₹ 3,88,52,000
Costs
EMD
₹ 7,77,040Document Cost
₹ 2,000Tender Fee
₹ 2,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPWD_415865_1Bid Award Id
ViewTender No
SE_PWD_NIB_NO-07_YEAR_2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://eproc.rajasthan.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing laying spreading and compacting specified graded sand, gravel (crushed graded stone material ) as per Table 400-1, 400-2 or any other coarse material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete. [MoRTH specification : Clause 401]. By mechanical means with all lead For Grading II Material
4876.88
7803008
1600
Providing and laying granular sub-base material as per MoRTH specification table 400-1, having P.I. not more than 6 including spreading in layers not exceeding 150 mm compacted thickness and consolidation by 8-10 tonne power roller to required camber and grade including cost of water and hire charges of machinery including T&P with all lead (Compacted thickness to be measured) with CBR of material not less than 15 (For rural roads only) as per MoRTH specification clause 401 with all lead For Grading VI Material
2550
2641800
1036
Providing, laying, spreading and compacting stone aggregate of specific size as per table 400-9 & 400-10 to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening and binding materials to fill-up the interstices of coarse aggregates, watering (with water browser) and rolling, making necessary earthen bund to protect edegs, lighting, guarding, barricading and maintenance of diversion etc. [MoRTH specification : Clause 404 & 112] (by manual means) with all leads (compacted thickness as specified to be measured) Using Screening Crushable type such as Moorum or Gravel Grading no.1 (63-45mm) crusher broken
2438.44
4408699
1808
Providing, laying, spreading and compacting stone aggregate of specific size as per table 400-9 & 400-10 to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening and binding materials to fill-up the interstices of coarse aggregates, watering (with water browser) and rolling, making necessary earthen bund to protect edegs, lighting, guarding, barricading and maintenance of diversion etc. [MoRTH specification : Clause 404 & 112] (by manual means) with all leads (compacted thickness as specified to be measured) Using Screening Crushable type such as Moorum or Gravel Grading no. 2 (53-22.4 mm) crusher broken
2438.44
4572075
1875
Labour charges for laying brick edging up to 23 cm deep and up to 11.5 cm. wide according to approved brick size (to be specified) including digging of trenches, fixing of bricks in position, refilling and disposal of surplus earth etc. complete.
17000
306000
18
Collection of well-burnt/ slightly over burnt bricks of minimum strength 100. Kg. Per sq.cm. of size, for soling/ Edging. Bricks with 3 Km lead
221000
1007760
4.56
Providing and applying primer coat over prepared surface or granular base with bitumen emulsion (SS-1) as per IS: 8887 & manufacturer’s specifications @ 8.5 kg /10 sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures including cleaning of road surface as per MoRTH specification CIause 502 & 112
32512.5
1267987
39
Providing and applying tack coat with bitumen emulsion (RS-1) on the prepared surface including cleaning as per IS : 8887 & manufacturer’s specifications @ 2.75 kg /10sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures as per MoRTH specification CI.503 & 112
32512.5
432416
13.3
Providing and laying open graded premix surfacing/ carpet 20mm thick (compacted) on prepared surface in a single course as wearing course, aggregates as per Table 500-23, heating bituminous binder @ 14.6 Kg/10 Sqm. and aggregates in Hot Mix Plant (including cost of antistripping compound , wherever required), transporting the mixed material with tipper and laying with paver finisher to the required level and grade, rolling with power roller 8-10 tonne but excluding cost of tack and seal coat with all lead for mix material. (MoRTH Specification : Clause 510 &112) In Hot Mix Plant 40-60 TPH, including loading of aggregates with F.E loader and laying with paver finisher (By mechanical means). with bitumen VG-30
32512.5
3706425
114
Providing and applying premixed seal coat type "B" comprising of thin application of fine aggregate (0.06 Cum. per 10 Sqm) premix with 6.8 Kg. per 10 sqm bitumen binder (including cost of antistripping compound, wherever required) in hot mix plant and laying and rolling with power roller 8-10 tonne including all lead of mix material [MORTH Specification : Clause 511] In Hot Mix Plant 40-60 TPH, including loading of aggregates with F.E loader and laying with paver finisher (By mechanical means).with bitumen VG-30
32512.5
1528087
47
Earth work in excavation in foundation trenches etc.in drains and channels etc. not exceeding 2m. depth, including dressing of bottom and sides of trenches, stacking the excavated soil 3m clear from the edge of excavation including disposal of surplus soil as directed within a lead of 1000 metres [MoRTH Specification : Clause 301,304] Ordinary Soil
612
53856
88
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/ Bed level as per MoRTH Specification : Clause 1000, 1500 & 1700 P.C.C. 1:4:8 mix with crushed stone aggregate 20 mm nominal size.
218.9
819999
3746
Providing and laying first class brick masonry work (minimum 10.5 MPa) up to a depth of 1.50 meters below ground and above 1.50m from Bed/ground level complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1300 Cement mortar 1:4 (1 cement : 4 coarse sand)
1098.14
4911980
4473
Providing Cement plaster 20 mm thick in cement mortar 1:4 at all levels as per MoRTH Specfication: Clause:1000 & 1300
3145.44
465525
148
Providing and laying Plain cement concrete mix with stone aggregate 20mm nominal size mechnically mixed and vibrated in foundation upto a depth of 1.50 metres below ground level and/or 1.50 metres above ground/bed level as per MoRTH specification : clause 1000, 1500 & 1700. P.C.C. grade M-15 in foundation & plinth upto 1.5 mtr. from ground level
26.56
121724
4583
S & F in position precast R.C.C. stone (M-15 mix) of standard IRC design including finishing in cement sand mortar 1:3, painting with enamel paint, printing letters and numerals etc. complete (MoRTH specifications clause : 800) Ordinary km stone 5th km Stone
2
7678
3839
S & F in position precast R.C.C. stone (M-15 mix) of standard IRC design including finishing in cement sand mortar 1:3, painting with enamel paint, printing letters and numerals etc. complete (MoRTH specifications clause : 800) Ordinary km stone Ordinary km stone
7
16086
2298
S & F in position precast R.C.C. stone (M-15 mix) of standard IRC design including finishing in cement sand mortar 1:3, painting with enamel paint, printing letters and numerals etc. complete (MoRTH specifications clause : 800) Ordinary km stone 200 m stone
34
17680
520
Supply of direction and place identification sign boards made out of 2mm thick MS sheet framed to angle iron 40 x 40 x 5mm and 2 vertical posts of angle iron 65 x 65 x 6mm, 4.60m long with hold fasts including excavation and fixing with CC M-15 (30 x 30 x 60cm) and transportation with painting with superior grade enamel paint of approved quality including lettering and figuring etc. complete as per IRC standard size 160 x 180cm (project board)
3
24600
8200
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type XI standards of ASTM D4956-09 specifications, fixed over 2mm thick Al / 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in GI Pipe (Medium class) 75mm dia- 3 mtr height, firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 10 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor.
8.64
84093
9733
Raised Pavment Marker ( Cats Eyes): Supplying and Fixing of Molded Shank Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 – DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the engineer. The contractor shall submit 2 years pre qualified warranty certificate from the manufacturer for satisfactory field performance during the time of bid submission
50
12400
248
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids complete as per IRC specifications 3.70 meter wide and 10 cm high for general traffic 3.70 meter wide and 10 cm high for general traffic
15
21180
1412
Providing and Fixing of Retro Reflectorised Cautionary, Mandatory, Regulatory and Information sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a GI Pipe (Medium class) 50mm dia - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor Cautionary sign boards (900mm equilateral triangle)
14
54110
3865
Providing and Fixing of Retro Reflectorised Cautionary, Mandatory, Regulatory and Information sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a GI Pipe (Medium class) 50mm dia - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor Mandatory sign boards (600mm Circular)
2
7052
3526
Providing and Fixing of Retro Reflectorised Cautionary, Mandatory, Regulatory and Information sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a GI Pipe (Medium class) 50mm dia - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor Stop sign boards (900mm side Octagon)
3
16275
5425
Providing and Fixing of Retro Reflectorised Cautionary, Mandatory, Regulatory and Information sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a GI Pipe (Medium class) 50mm dia - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor Facility sign boards (600 x 800 mm ractangular)
2
8998
4499
Providing and laying of hot applied thermo plastic compound with material conforming to Clause 803.4 of MoRTH having Titanium Dioxide (for white) minimum 10% by weight and softening point 102.5 ±9.5°C, inclusive of type-1 reflectorising glass beads as per table 800-9, 800-10 applied in uniform thickness with reflectorising glass beads type-2 in addition @ 250 gm/sqm with a road marking machine as per IRC : 35 complete with traffic diversion arrangement as per MoRTH specification clause 803.4. Thickness is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.'Lane, Centreline, Edge line, pedestrian crossings, markings and other marking along strips for 2.5 mm thickness of marking (thickness excluding drop on glass beads)
1715
872935
509
'Providing and laying of hot applied thermo plastic compound with material conforming to Clause 803.4 of MoRTH having Titanium Dioxide (for white) minimum 10% by weight and softening point 102.5 ±9.5°C, inclusive of type-1 reflectorising glass beads as per table 800-9, 800-10 applied in uniform thickness with reflectorising glass beads type-2 in addition @ 250 gm/sqm with a road marking machine as per IRC : 35 complete with traffic diversion arrangement as per MoRTH specification clause 803.4. Thickness is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holesPedestrian crossings, Rumble strips, transverse bar markings and other marking along strips for 5.0 mm thickness of marking (thickness excluding drop on glass beads)
28.05
27713
988
Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres. [MoRTH Specification : Clause 301, 304]. Ordinary Soil
664.02
117531
177
Providing, laying & fixing in position RCC spun or hume pipes ISI marked with proper jointing in required slope packed in the gasket of hume or spun yarn and neatly finished with rich grout of cement moratar 1:3 or having flexible rubber ring joint made with prefectly air and water tight including testing of joints as per MoRTH Specfication : Clause : 1000 & 2900 . NP - 3 600 mm dia
172.5
336720
1952
Providing and laying first class brick masonry work (minimum 10.5 MPa) in superstructure up to a height 4 meters or part thereof above 1.5 meter level from Bed/Ground level complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1300 Cement mortar 1:4 (1 cement : 4 coarse sand)
14.09
65138
4623
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered or concrete surface as per MoRTH specification clause 803
90.17
7574
84
Providing and laying Plain cement concrete mix with stone aggregate 20mm nominal size mechnically mixed and vibrated in foundation upto a depth of 1.50 metres below ground level and/or 1.50 metres above ground/bed level as per MoRTH specification : clause 1000, 1500 & 1700.R.C.C. grade M-20 in bed plates upto ground level excluding cost of steel reinforcement but including the cost of centering & shuttering
4.76
24209
5086
Providing and laying Plain cement concrete mix with stone aggregate 20mm nominal size mechnically mixed and vibrated in foundation upto a depth of 1.50 metres below ground level and/or 1.50 metres above ground/bed level as per MoRTH specification : clause 1000, 1500 & 1700.R.C.C. grade M-25 in superstructure upto 4.5 mtr. from ground level excluding cost of steel reinforcement but including the cost of centering & shuttering
28.9
174151
6026
Providing & fabricating steel reinforecemnt for RCC work including cutting, bending, placing in position and binding complete including cost of binding wire as per MoRTH Specification : Section 1000 & 1600 .HYSD/ TMT Steel bars
3.7
325970
88100