Public Works Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date17 Oct 2024
Closing DateCancelled
Tender Amount₹ 3,00,84,000 
Notes
Download

Costs

  • EMD

    ₹ 6,01,680
  • Document Cost

    ₹ 2,000
  • Tender Fee

    ₹ 2,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation up to a depth of 1.5 meters below ground level and 1.50 meters above Ground/Bed level.[MoRTH Specification : Clause 1000/1700] Cement concrete 1:3:6 mix with stone aggregate 20mm crusher broken.

184.89

3756

694428.06

... More
Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump. P.C.C.M-20 grade

398.3

4322

1721452.6

... More
Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump. P.C.C.M-15 grade

1032.7

3918

4046118.6

... More
Providing and laying Dry Boulder Pitching in flooring at all levels [MoRTH Specification Clause: 2500]

20.63

507

10456.88

... More
Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size 2.00 M x 2.00 M

75

38000

2850000

... More
Back filling behind abutment, wing wall and return wall, in 150mm layers, with mechanical compaction, complete with all lead and lift, as per drawing and technical specification. [MoRTH Specification : Clause : 304] Sandy material

189.94

657

124791.24

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted by vibratory roller 8-10 Tonne to meet requirement of Table 300-2 as per MoRTH specification Clause No. 305.

2210

130

287300

... More
Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means with all lead & lift For Grading I Material

157.95

890

140575.5

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per IRC:SP:49-2014

146.25

2452

358605

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane (125 micron), sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound including vaccume dewatering process, finishing to lines and grades as per drawing CC design mix grade M30

270

6250

1687500

... More
Supply of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long.

2

1570

3140

... More
Fixing of flood gauge (water Gauge) in cement concrete M-15 mix size 30x30x60 cm. complete including transportation excavation etc. complete

2

438

876

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all around it.

2

834

1668

... More
Fixing of Hazard marker including excavation & cement concrete (1:3:6) (30x30x30cm size) in foundation, curing complete as per specifications.

2

134

268

... More
Part '2' : Construction and Permanent Restoration of CD work on A/R Jodhpuriya to Chaturbhujpura at Ch.3/800

-

-

-

... More
PART 'A' : 5 Row Box Culvert 1.50m x 1.50m

-

-

-

... More
Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.[MoRTH Specification : Clause : 304]In ordinary Soil [MoRTH Specification : Clause : 301]Depth up to 3m

352.41

112

39469.92

... More
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation up to a depth of 1.5 meters below ground level and 1.50 meters above Ground/Bed level.[MoRTH Specification : Clause 1000/1700] Cement concrete 1:3:6 mix with stone aggregate 20mm crusher broken.

40.77

3756

153132.12

... More
Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump. P.C.C.M-15 grade

312.01

3918

1222466.93

... More
Providing and laying Dry Boulder Pitching in flooring at all levels [MoRTH Specification Clause: 2500]

8.25

507

4182.75

... More
Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size 1.50 M x 1.50 M

37.5

22830

856125

... More
Back filling behind abutment, wing wall and return wall, in 150mm layers, with mechanical compaction, complete with all lead and lift, as per drawing and technical specification. [MoRTH Specification : Clause : 304] Sandy material

75.28

657

49456.33

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted by vibratory roller 8-10 Tonne to meet requirement of Table 300-2 as per MoRTH specification Clause No. 305.

351

130

45630

... More
Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means with all lead & lift For Grading I Material

95.82

890

85279.8

... More
Providing, laying, spreading and compacting stone aggregate for Wet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying in uniform layers with motor grader/Front end Loader/paver finisher, in sub base/ base course on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specification : Clause 406) by mechanical means with lead & lift

91.5

1500

137250

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane (125 micron), sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound including vaccume dewatering process, finishing to lines and grades as per drawing CC design mix grade M30

206.25

6250

1289062.5

... More
Supply of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long.

1

1570

1570

... More
Fixing of flood gauge (water Gauge) in cement concrete M-15 mix size 30x30x60 cm. complete including transportation excavation etc. complete

1

438

438

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all around it.

1

834

834

... More
Fixing of Hazard marker including excavation & cement concrete (1:3:6) (30x30x30cm size) in foundation, curing complete as per specifications.

1

134

134

... More
Part '3' : Construction and Permanent Restoration of CD work on Raholi Road to Pathraj Mustarka at Ch. 0/900

-

-

-

... More
PART 'A' : 2 Row Box Culvert 1.50m x 1.50m

-

-

-

... More
Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.[MoRTH Specification : Clause : 304]In ordinary Soil [MoRTH Specification : Clause : 301]Depth up to 3m

102.24

112

11450.88

... More
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation up to a depth of 1.5 meters below ground level and 1.50 meters above Ground/Bed level.[MoRTH Specification : Clause 1000/1700] Cement concrete 1:3:6 mix with stone aggregate 20mm crusher broken.

11.72

3756

44035.34

... More
Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump. P.C.C.M-15 grade

116.46

3918

456282.44

... More
Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size 1.50 M x 1.50 M

15

22830

342450

... More
Back filling behind abutment, wing wall and return wall, in 150mm layers, with mechanical compaction, complete with all lead and lift, as per drawing and technical specification. [MoRTH Specification : Clause : 304] Sandy material

89.51

657

58804.79

... More
Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means with all lead & lift For Grading I Material

23.49

890

20906.1

... More
Providing, laying, spreading and compacting stone aggregate for Wet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying in uniform layers with motor grader/Front end Loader/paver finisher, in sub base/ base course on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specification : Clause 406) by mechanical means with lead & lift

32.63

1500

48937.5

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane (125 micron), sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound including vaccume dewatering process, finishing to lines and grades as per drawing CC design mix grade M30

55.5

6250

346875

... More
Supply of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long.

1

1570

1570

... More
Fixing of flood gauge (water Gauge) in cement concrete M-15 mix size 30x30x60 cm. complete including transportation excavation etc. complete

1

438

438

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all around it.

1

834

834

... More
Fixing of Hazard marker including excavation & cement concrete (1:3:6) (30x30x30cm size) in foundation, curing complete as per specifications.

1

134

134

... More
Part '4' : Construction and Permanent Restoration of CD work on Sindra to Badodiya Bhanwar Sagar at Ch. 1/050

-

-

-

... More
PART 'A' : 3 Row Box Culvert 1.50m x 1.50m

-

-

-

... More
Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.[MoRTH Specification : Clause : 304]In ordinary Soil [MoRTH Specification : Clause : 301]Depth up to 3m

196.02

112

21954.24

... More
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation up to a depth of 1.5 meters below ground level and 1.50 meters above Ground/Bed level.[MoRTH Specification : Clause 1000/1700] Cement concrete 1:3:6 mix with stone aggregate 20mm crusher broken.

22.6

3756

84893.11

... More
Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump. P.C.C.M-15 grade

232.54

3918

911103.47

... More
Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size 1.50 M x 1.50 M

22.5

22830

513675

... More
Back filling behind abutment, wing wall and return wall, in 150mm layers, with mechanical compaction, complete with all lead and lift, as per drawing and technical specification. [MoRTH Specification : Clause : 304] Sandy material

78.95

657

51868.84

... More
Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means with all lead & lift For Grading I Material

22.28

890

19824.75

... More
Providing, laying, spreading and compacting stone aggregate for Wet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying in uniform layers with motor grader/Front end Loader/paver finisher, in sub base/ base course on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specification : Clause 406) by mechanical means with lead & lift

30.94

1500

46406.25

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane (125 micron), sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound including vaccume dewatering process, finishing to lines and grades as per drawing CC design mix grade M30

53.25

6250

332812.5

... More
Supply of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long.

1

1570

1570

... More
Fixing of flood gauge (water Gauge) in cement concrete M-15 mix size 30x30x60 cm. complete including transportation excavation etc. complete

1

438

438

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all around it.

1

834

834

... More
Fixing of Hazard marker including excavation & cement concrete (1:3:6) (30x30x30cm size) in foundation, curing complete as per specifications.

1

134

134

... More
Part '5' : Construction of 6 Row Box Culvert at Raholi to Tumbipura Road At KM 0/100

-

-

-

... More
Box Culvert 6 ROW (1.5 Mtr. X 1.5 Mtr.)

-

-

-

... More
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per MoRTH specification clause 202.

120

622

74640

... More
Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.[MoRTH Specification : Clause : 304] In hard Soil [MoRTH Specification : Clause : 301] Depth up to 3m

754.4

119

89773.6

... More
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation up to a depth of 1.5 meters below ground level and 1.50 meters above Ground/Bed level.[MoRTH Specification : Clause 1000/1700] Cement concrete 1:3:6 mix with stone aggregate 20mm crusher broken

66.79

3756

250870.75

... More
Providing and laying cement concreting including curing compaction etc. complete using stone aggregate 20mm nominal size mechanically mixed & vibrated in foundation and plinth including the cost of shuttering if required

236.83

5125

1213753.75

... More
Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size1.5 M X1.5 M

60

22830

1369800

... More
Providing and laying Steel reinforcement at any level in foundation complete as per drawing and technical Specification.[MoRTH Specification : Section: 1600(N)] HYSD bar reinforcement

7.11

88737

630476.39

... More
Providing, laying, spreading and compacting stone aggregate for Wet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying in uniform layers with motor grader/Front end Loader/paver finisher, in sub base/ base course on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specification : Clause 406) by mechanical means with lead & lift

91.98

1500

137965.5

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per IRC:SP:49-2014

87.4

2452

214304.8

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane (125 micron), sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound including vaccume dewatering process, finishing to lines and grades as per drawing CC design mix grade M30

190

6250

1187500

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all around it.

4

834

3336

... More
Supply of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long.

2

1570

3140

... More
Fixing of flood gauge (water Gauge) in cement concrete M-15 mix size 30x30x60 cm. complete including transportation excavation etc. complete

2

438

876

... More
Supply of mandatory / regulatory reflective sign board fixed on 3 meter long Angle Iron of size 65x65x6 mm complete as per IRC- 67-1977 made of 2 mm thick M.S. sheet stove enameled paint and reflective symbol. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom Stop signs with definition plate size 30x20 cm Stop signs with definition plate size 30x20 cm

2

1885

3770

... More
Part '6' : Construction of 8 Row Box Culvert at Gunsi to Raholi Upto Distt Border Road At KM 1/000

-

-

-

... More
Box Culvert 8 ROW (2.0 Mtr. X 2.0 Mtr.)

-

-

-

... More
Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.[MoRTH Specification : Clause : 304] In hard Soil [MoRTH Specification : Clause : 301] Depth up to 3m

680.8

119

81015.2

... More
Providing and laying mechanically mixed and vibrated Cement Concrete in foundation up to a depth of 1.5 meters below ground level and 1.50 meters above Ground/Bed level.[MoRTH Specification : Clause 1000/1700] Cement concrete 1:3:6 mix with stone aggregate 20mm crusher broken

89.41

3756

335816.45

... More
Providing and laying cement concreting including curing compaction etc. complete using stone aggregate 20mm nominal size mechanically mixed & vibrated in foundation and plinth including the cost of shuttering if required

194.71

5125

997899

... More
Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size 2.0 M X 2.0 M

80

38000

3040000

... More
Providing and laying Steel reinforcement at any level in foundation complete as per drawing and technical Specification.[MoRTH Specification : Section: 1600(N)] HYSD bar reinforcement

5.84

88737

518312.82

... More
Providing, laying, spreading and compacting stone aggregate for Wet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying in uniform layers with motor grader/Front end Loader/paver finisher, in sub base/ base course on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specification : Clause 406) by mechanical means with lead & lift

45.15

1500

67725

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per IRC:SP:49-2014

34.96

2452

85721.92

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane (125 micron), sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound including vaccume dewatering process, finishing to lines and grades as per drawing CC design mix grade M30

76

6250

475000

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all around it.

2

834

1668

... More
Supply of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long.

2

1570

3140

... More
Fixing of flood gauge (water Gauge) in cement concrete M-15 mix size 30x30x60 cm. complete including transportation excavation etc. complete

4

438

1752

... More
Supply of mandatory / regulatory reflective sign board fixed on 3 meter long Angle Iron of size 65x65x6 mm complete as per IRC- 67-1977 made of 2 mm thick M.S. sheet stove enameled paint and reflective symbol. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom Stop signs with definition plate size 30x20 cm Stop signs with definition plate size 30x20 cm

2

1885

3770



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.