Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Dec 2024
Closing Date5 Jan 2025
Tender Amount₹ 6,75,11,000 
Notes
Download

Costs

  • EMD

    ₹ 13,50,220
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 2,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
110 mm dia

200

582

116400

... More
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing,disinfection, commissioning etc. complete as per technicalspecifications and direction of Engineer-in-charge of following classand diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing,design and layout are inclusive in RM measurement of the item andshall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-100 PN-6

-

-

-

... More
90 mm dia

15388

264

4062432

... More
110 mm dia

2357

442

1041794

... More
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.

-

-

-

... More
125 mm dia

3080

573

1764840

... More
140 mm dia

1969

713

1403897

... More
160 mm dia

726

897

651222

... More
180 mm dia

2940

1125

3307500

... More
200 mm dia

351

1348

473148

... More
225 mm dia

418

1697

709346

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
150 mm

942

2082

1961244

... More
200 mm

3450

2554

8811300

... More
250 mm

25

3307

82675

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil

-

-

-

... More
In All Type of Soil

12839.94

200

2567988

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

2228.33

757

1686845.81

... More
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous courses

68.59

416

28533.44

... More
Granular courses

342.84

296

101480.64

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

891.34

4678

4169688.52

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

1336.99

6162

8238532.38

... More
Providing and laying granular sub-base material having P.I. not more than 6 including spreading in layers not exceeding 150 mm compacted thickness and consolidation by 8-10 tonne power roller to required camber and grade including cost of water and hire charges of machinery including T&P with all lead (Compacted thickness to be measured).as per MoRTH specification table 400-1, 400-2,Grading - I Material

205.69

705

145012.16

... More
Providing, laying, spreading and compacting stone aggregate for Wet Mix Macadam (as per table 400-12 and 400-13) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying in uniform layers with motor grader/Front end Loader/paver finisher, in sub base/ base course on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specification : Clause 406 & Clause 112) by mechanical means with all lead .

205.69

1464

301131.62

... More
Providing and laying open graded premix carpet 20mm thick (compacted) on prepared surface in a single course as wearing course composed of specified graded crushed aggregates as per Table 500-23, heating bituminous binder @ 14.6 Kg/10 Sqm.(60/70 grade) and aggregates in Hot Mix Plant (including cost of anti-stripping compound , wherever required), transporting the mixed material with tipper and laying with paver finisher to the required level and grade, rolling with power roller, 8-10 tonne but excluding cost of tack and seal coat with all lead .[MoRTH Specification : Clause 510 & 112]

-

-

-

... More
In Hot Mix Plant 40-60 TPH, including loading of aggregates with Front end loader bitumen VG 30

27.43

100

2742.6

... More
Providing and laying premix seal coat using hot mix plant and paver finisher with aggregates of 6.7mm size defined as 100% passing through 11.20mm sieve and retained on 2.36mm sieve with 0.09 cum per 10 Sqm and 4.5%bitumen including preparation and transportation of mix, spreading, laying and rolling etc. complete in all respect including cost of binder with all lead of mix material.

-

-

-

27.43

56

1535.86

... More
Providing and laying paving fabric with physical requirements as per table 704-2 over a tack coat of paving grade Bitumen 80-100 penetration, laid at the rate of 1 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistant membrane and crack retarding layer. Paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface

27.43

338

9269.99

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

3

11616

34848

3

13234

39702

... More
Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
Air valve chamber of size0.9m x1m x1.695m for air valve size-from 50 mm-to-80mm

3

39600

118800

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated CI sluice valve of Class PN 1.0

-

-

-

... More
100 mm HW

8

8649

69192

... More
150 mm HW

5

13595

67975

... More
200 mm HW

4

22603

90412

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
100 mm dia.

9

3666

32994

... More
150 mm dia.

15

5758

86370

... More
200 mm dia.

16

8564

137024

2

11729

23458

... More
300 mm dia.

5

14024

70120

... More
400 mm dia.

2

24715

49430

... More
500 mm dia.

1

34191

34191

... More
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
For Class-A loading

-

-

-

... More
Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm

7

29800

208600

... More
Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm

6

33500

201000

... More
Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm

9

43500

391500

... More
Sluice valve chamber of size1.61m x1.75m x2.795m for pipe size-from 500-to-700mm

1

78900

78900

... More
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
BFM 150 mm

2

24022

48044

... More
BFM 200 mm

1

30414

30414

... More
BFM 250 mm

1

64440

64440

... More
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M

-

-

-

... More
400 KL

400000

17

6904000

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. Extra 30m 150mm Pipe for one more inlet pipe for 250KL OHSR of tubewell feeding

-

-

-

... More
100 mm

29

2259

65511

... More
150 mm

58.3

3249

189416.7

... More
200 mm

55.8

4250

237150

... More
Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.

-

-

-

... More
MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet)

1250

126

157500

... More
Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4

-

-

-

... More
At Zone-8 150KL

150000

7

1071000

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR pipes.

-

-

-

... More
100 mm

10

2146

21460.5

... More
250 mm

15

5446

81695.25

... More
Providing, lowering, aligning, fixing in position in pipe line at work site,DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) ,Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete onfirming to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. PN 1.6 Manually Operated

-

-

-

... More
100 mm

1

11554

11554

... More
150 mm

6

19109

114654

... More
200 mm

12

29396

352752

... More
250 mm

1

48781

48781

... More
300 mm dia

4

62128

248512

... More
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN1.6

-

-

-

... More
400 mm dia

2

287479

574958

... More
500 mm dia

1

414750

414750

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
150 mm dia

4

20940

83760

... More
200 mm dia

6

36510

219060

... More
300 mm dia

1

77472

77472

... More
400 mm dia

1

107465

107465

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.

-

-

-

... More
150 mm dia

4

11445

45780

... More
200 mm dia.

6

12954

77724

... More
300 mm dia.

1

19614

19614

... More
400 mm dia.

1

30524

30524

... More
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum

3

3098

9294

... More
Construction of Pump house of RCC framed structure with pump pit in RCC walls as per scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. complete as per direction of Engineer-in-charge. The GA, structure, electrical, sanitary, P&ID, SLD to be prepared by the contractor and submitted to department for approval for earth quake zone II.

-

-

-

... More
Pump House with Monorail arrangement

24

22320

535680

... More
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.

200

5820

1164000

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.

196.2

121

23739.96

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
5.5 KW (7.5 HP)

2

55225

110450

... More
11.0 KW (15 HP)

2

83148

166296

... More
15.0 KW (20.0 HP)

4

108825

435300

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
Discharge 91 to 100 LPS and head 61 to 70 M

2

990485

1980970

... More
SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge.

-

-

-

... More
DOL STARTER 5.5 KW (7.5HP) - : For 2 motors (1 W+ 1S) I/C - MCB 40A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 25A ,TP, 10 KA, C Curve (2), Power Cont 12A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2)

1

51448

51448

... More
STAR DELTA STARTER 11.0 KW (15.0 HP) - :For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

1

70561

70561

... More
STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

2

99226

198452

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

... More
110 KW

1

229712

229712

... More
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

16

3651

58416

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
Armoured Cable16.0 Sq. mm 4 core

400

234

93600

... More
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
EFM 150 mm

2

139687

279374

... More
EFM 300 mm

1

219283

219283

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.

-

-

-

... More
Note: Road cut and restoration is not part of this item and paid separately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

550

1780

979000

... More
Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..

1375

200

275000

... More
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

1375

44

60500

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.

-

-

-

... More
300 mm Dia 8 mm thick casing pipe.

88

18353

1615064

... More
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge.

337.59

254

85747.6

... More
Dismantling CI or asbestos rain water pipe with fitting and clamps including stacking within 50 meter lead:

-

-

-

... More
100mm dia pipe.

16

19

304

... More
Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes and including stacking of pipes within 50 meter lead:

-

-

-

... More
15mm to 40mm nominal bore.

16

41

656

... More
Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes, and stacking the same within a lead of 50 meter, of dia:

-

-

-

... More
Up to 150mm.

6

86

516

... More
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.

42

15

630

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
In cement mortar.

328

538

176464

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix

16.32

5609

91550.32

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)

-

-

-

... More
Thermo-mechanically Treated bars (Conforming of relevent IS code)

13.06

77

1005.44

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :

-

-

-

... More
Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.

107.1

340

36414

... More
Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75

-

-

-

... More
Cement mortar 1 : 4 (1 cement : 4 coarse sand)

246

553

136038

... More
Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in :

-

-

-

... More
Cement mortar 1 : 4 (1 cement : 4 coarse sand)

122

377

45994

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :

-

-

-

... More
20mm thick .

183

202

36966

... More
12mm thick .

183

163

29829

... More
6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)

100

139

13900

... More
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)

100

235

23500

... More
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts embedding hold fasts in cement concrete blocks with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) painting two coats of coal tar to sides of chaukhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 metres lead.

-

-

-

... More
Door chowkhats

2.64

615

1623.6

... More
Window chowkhats

4.4

383

1685.2

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:

-

-

-

... More
New work (two or more coats) over and including scrapping and priming coat with cement primer.

244

75

18300

... More
Repair to brick masonary in cement sand mortar 1:6 with new brick.

10

354

3540

... More
Labour Charges for Removing & Refixing the water Storage Tank of all sizes and including all Necessary fitting complete in all respect as per approved sample and direction of engineer in charge.

1

369

369

... More
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 750 litre

1

5881

5881

... More
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :

-

-

-

... More
15mm dia nominal bore

2

101

202

... More
20mm dia nominal bore

2

140

280

... More
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.

200

72

14400

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

200

83

16600

... More
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide

600

96

57600

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR

-

-

-

... More
Short point (up to 3 mtr.)

10

359

3590

... More
Medium point (up to 6 mtr.)

10

578

5780

... More
Long point (up to 10 mtr.)

8

772

6176

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper earth conductor 1.1 kV grade(IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thickwith earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket,Modular face plate with grid plate, screws, making connections, testingetc. as required. For specification of copper Conductor, PhenolicLaminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work referAnnexure 'A' attached with this BSR

-

-

-

... More
On board

10

357

3570

... More
Short point (up to 3 mtr.)

10

507

5070

... More
Medium point (up to 6 mtr.)

10

726

7260

... More
Long point (up to 10 mtr..)

8

920

7360

... More
Supply , Installation, Testing and Comissioning of Window type Airconditioners as per BEE star rating complete with copper power cableupto 3 Mtr, wireless Remote, suitable for working between 230 V +/-10% with low & high voltage cutoff and 50 Hz ,1 phase AC supplycapable of performing, cooling, dehumidification, air circulation R-32/R-410 Green Refrigerant with Scroll / rotary compressor complete withfixing including T&P & labour etc as required complete in all respect asspecified of following capacity. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure "A" attached with this BSR .

-

-

-

... More
1.5 TR ISEER not less then 3.0

1

32340

32340

... More
Supply , Installation, Testing and Comissioning of Inverter type AirCooled Hi Wall split type Air conditioners with latest star rating systemas per BEE amended upto date complete with Indoor unit(IDU), Out doorunit (ODU), surface / concealed copper Refrigerant piping with insulation(closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for workingbetween 230V +/- 10% with low & high voltage cutoff and 50 hz , singlephase AC supply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotary compressor. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached with thisBSR .

-

-

-

... More
1.0 TR ISEER not less then 3.8

2

40096

80192

... More
Providing & Fixing of BEE Star rated copper wounded double ballbearing capacitor start, aluminium body & Metallic blade ceiling fanConforming to all the performance requirements laid down in IS374:2019 including all amendments, as applicable ; & Carry BIS licensing(i.e. ISI marking) with down rod up to 80 cm with secondary supportsafety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulatedflexible copper conductor making connection testing etc. as required. Allas per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached with thisBSR

-

-

-

... More
1200 mm Sweep BEE 2 Star rated (service value =4.5 to 5 )

4

2025

8100

... More
Cost for basic service charges, Administration and Management, running of office, staff quarters, comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, IEC activities as per scope of work, cost of material required for maintenance & repairs, cost of lubricants, saltf for producing chorine, consumables spare parts (if the spare parts supplied to PHED are used in emergency) as per scope of work & items & conditions of contract no, amt will be paid for O&M in DLP

-

-

-

... More
For the 1st year of O&M after DLP

1

581799

581799

... More
For the 2nd year of O&M after DLP

1

610889

610889

... More
For the 3rd year of O&M after DLP

1

641434

641434

... More
For the 4th year of O&M after DLP

1

673505

673505

... More
For the 5th year of O&M after DLP

1

707180

707180



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.