Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date7 Feb 2022
Closing Date10 Mar 2022
Tender Amount₹ 98,40,00,000 
Notes
Download

Costs

  • EMD

    ₹ 1,96,80,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,000

Summary

Work Of Retrofitting Of 151 Villages Of Aspur, Dovra , Dungarpur Block And

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
200 mm dia

13926

-

2202

... More
250 mm dia

4480

-

2851

... More
300 mm dia

888

-

3639

... More
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-100 PN-6 (Dia in mm)

-

-

-

... More
125 mm dia

1508

-

494

... More
140 mm dia

2895

-

615

... More
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-100 PN-6 (Dia in mm)

-

-

-

... More
75 mm dia

694748

-

160

... More
90 mm dia

186862

-

228

... More
110 mm dia

47095

-

381

... More
HDPE PE-100 PN-10 (Dia in mm)

-

-

-

... More
90 mm dia

125295

-

337

... More
110 mm dia

1340

-

502

... More
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.

-

-

-

... More
HDPE PE-80 PN-6 (Dia in mm)

-

-

-

... More
125 mm dia

11518

-

572

... More
140 mm dia

6391

-

713

... More
160 mm dia

2671

-

897

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.

209758.72

-

172

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:

-

-

-

... More
In Soft Rock

-

-

-

... More
upto 1.5 m

82817.03

-

322

... More
In Hard Rock (Blasting Probihited)

-

-

-

... More
upto 1.5 m

121509.46

-

674

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) at Junctions, Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
100 mm dia

35

-

9960

... More
150 mm dia

11

-

16473

... More
200 mm dia

7

-

25341

... More
250 mm dia

1

-

42053

... More
Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0

-

-

-

... More
100 mm dia

35

-

3160

... More
150 mm dia

11

-

4964

... More
200 mm dia

7

-

7383

... More
250 mm dia

1

-

10111

... More
Construction of Junction Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge

23

-

48881

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet)

16063.53

-

122

... More
Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous Courses

7474.45

-

362

... More
Granular Courses

11211.65

-

259

... More
Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

22869.57

-

653

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

17045.21

-

4033

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

26016.9

-

5312

... More
Supplying and filling with River sand under the HDPE Pipes

64555.2

-

746

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
80 mm dia

252

-

7877

... More
125 mm dia

6

-

14730

... More
Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6

-

-

-

... More
80 mm dia

252

-

2715

... More
125 mm dia

6

-

4131

... More
Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge.

-

-

-

... More
100 mm dia

9

-

53000

... More
150 mm dia

2

-

71200

... More
Construction of Sluice Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge

-

-

-

... More
1200 mm x 900 mm x 1450 mm (upto 150 mm dia)

288

-

20987

... More
1500 mm x 1200 mm x 1550 mm (upto 300 mm dia)

1

-

29356

... More
Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)

-

-

-

... More
100 mm thick.

65705.95

-

291

... More
Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure Reducing / Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body & Bonet - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc - Flexible, non-wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM (FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M / AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316, raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316 ,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze ,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI-316 ,Throttling plug - Stainless Steel, AISI-304, Nut- Bolts - SS Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. nsersion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
200 mm dia

1

-

180853

... More
Providing, installation, testing, trial run and commissioning of the following, as per specifications

-

-

-

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
CPS-3 to Kareliya ESR ,Vadagodiya ESR Route route 8.15 LPS / 43 m head/9.3 KW (1W)

1

-

67983

... More
CPS-3 to Garabhabha ESR ,Masana ESR ,Katarwa ESR ,Paragi Basti Route route 6.47 LPS / 71 m head/11 KW (1W)

1

-

71679

... More
CPS-5 to Owadiya ESR Route & CPS-5 to Devsomnath ESR ,Karata ESR ,Dhawari ESR Route route 14.34 LPS / 65 m head/18.5 KW (1W+1S)

2

-

123818

... More
CPS-8 to Unadhara ESR Route & CPS-8 to Bharatpur ESR ,Upergaon ESR Route route 15.35 LPS / 42 m head/15 KW (1W)

1

-

93815

... More
CPS-9 to Ransagar Pachor ESR Route route 5.36 LPS / 62 m head/7.5 KW (1W)

1

-

58202

... More
CPS-10 to Teejwar ESR ,Sarkan Sai ESR ,Banga Talai ESR Route route 12.9 LPS / 75 m head/18.5 KW (1W)

1

-

123818

... More
CPS-10 to Khaparda ESR ,Gokulpura ESR Route route 12.38 LPS / 65 m head/18.5 KW (1W)

1

-

123818

... More
CPS-11 to Margiya ESR ,Raiga Fala ESR ,Katara Ghati ESR Route route 6.42 LPS / 83 m head/11 KW (1W)

1

-

71679

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
CPS-4 to Savgar ESR ,Ratanpura ESR ,Nayagara ESR ,Dewla Thira ESR Route route 16.13 LPS / 70 m head/21 KW (1W)

1

-

360058

... More
CPS-8 to Damdi ESR ,Dolwar Nichali ESR ,Talaiya ESR Route route 18.42 LPS / 60 m head/21 KW (1W)

1

-

282163

... More
CPS-6 to Bhojoto ka ora ESR ,Dungra ESR Route & CPS-6 to Modra ESR ,Masaniya ESR ,Paheta ESR Route route 32.07 LPS / 79 m head/40 KW (1W+1S)

2

-

424582

... More
CPS-7 to Nepalpura ESR ,Pal Kolkhanda ESR Route & CPS-7 to Nayagaon ESR ,Badhi Ghati ESR Route & CPS-7 to Ragela ESR ,New Abadi ESR ,Samota Kaora ESR Route route 29.08 LPS / 71 m head/33 KW (1W+1S)

2

-

360058

... More
Supply erection testing commissioning of Horizontal split casing pumps & motors of approved duty conditions as per scope of work and specification given in the tender documents.

-

-

-

... More
CPS-9 to Khedakhas ESR ,BC Mala ESR ,Kankarired ESR Route route 13.56 LPS / 98 m head/25 KW (1W)

25

-

4950

... More
CPS-11 to Thaiyata ESR ,Rani Ghati ESR ,Lambired ESR ,Hamited Fala ESR ,Jhalari ESR , Route route 14.83 LPS / 98 m head/28 KW (1W)

28

-

4950

... More
MS Header pipe with all fittings such as flanges, bens, end plug etc. Size mm

-

-

-

... More
250 mm dia 6 mm thick

21

-

3691

... More
300 mm dia 6 mm thick

21

-

3960

... More
350 mm dia 6 mm thick

21

-

5546

... More
MS suction pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.

-

-

-

... More
200 mm dia 6 mm thick

12

-

3479

... More
250 mm dia 6 mm thick

15

-

3691

... More
300 mm dia 6 mm thick

12

-

3960

... More
350 mm dia 6 mm thick

6

-

5546

... More
400 mm dia 6 mm thick

6

-

6325

... More
MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-

-

-

-

... More
150 mm dia 6 mm thick

15

-

2816

... More
200 mm dia 6 mm thick

20

-

3479

... More
250 mm dia 6 mm thick

30

-

3691

... More
300 mm dia 6 mm thick

10

-

3960

... More
350 mm dia 6 mm thick

10

-

5546

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. At Individual Delivery Pipe Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
150 mm dia

3

-

120432

... More
200 mm dia

4

-

133923

... More
250 mm dia

6

-

153176

... More
300 mm dia

2

-

167176

... More
350 mm dia

2

-

220797

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 At Individual Suction Pipe

-

-

-

... More
200 mm dia

4

-

25341

... More
250 mm dia

5

-

42053

... More
300 mm dia

4

-

53559

... More
350 mm dia

2

-

100494

... More
400 mm dia

2

-

131616

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.

-

-

-

... More
150 mm dia

3

-

9866

... More
200 mm dia

8

-

11167

... More
250 mm dia

11

-

13674

... More
300 mm dia

6

-

16909

... More
350 mm dia

4

-

21227

... More
400 mm dia

2

-

26314

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-incharge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6, Motorised Operated

-

-

-

... More
350 mm dia

2

-

186260

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M, Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,BushBrass with EPDM/NBR "O" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. PN 1.6

-

-

-

... More
150 mm dia

3

-

18052

... More
200 mm dia

4

-

31474

... More
250 mm dia

6

-

47476

... More
300 mm dia

2

-

66786

... More
350 mm dia

2

-

71739

... More
Glycerine filled pressure gauges (0-10 kg/cm2)

17

-

1280

... More
Providing, installation, testing, trial run and commissioning of the following, as per the specifications

-

-

-

... More
STAR DELTA STARTER 7.5 KW (10.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)

1

-

58735

... More
STAR DELTA STARTER 9.3 KW (12.5 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)

1

-

60615

... More
STAR DELTA STARTER 11.0 KW (15.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

2

-

64153

... More
STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

1

-

91403

... More
STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2)

3

-

99109

... More
STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2)

2

-

111880

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

2

-

91912

2

-

100643

2

-

112221

... More
Earthing system complete for LT equipments

-

-

-

... More
For LT Panet & motors Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

9

-

5500

... More
Provision of Solar Based Water Tank system (excluding construction of borewells)

-

-

-

... More
5000 Liter X 2 Nos. PE water tank, staging 10 meter.

5

-

1524430

... More
7500 Liter X 2 Nos. PE water tank, staging 10 meter.

5

-

1563402

... More
5000 Liter X 2 Nos. PE water tank , staging 12 meter.

2

-

1600694

... More
7500 Liter X 2 Nos. PE water tank, staging 12 meter.

2

-

1639666

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification. 300 mm Dia 8 mm thick casing pipe with protective coating.

220

-

16737

... More
Providing & Fixing Sluice valve 100 mm dia. at both ends and Dismantling Joint

18

-

13120

... More
Providing & Fixing Sluice valve 150 mm dia. at both ends and Dismantling Joint

4

-

21437

... More
Construction of chamber at both ends with pre-cast RCC slab on top with locking arrangement as per NH drawing

22

-

20987

... More
Earth work in excavation over areas (exceeding 30cm in depth, 1.5 Mtr. in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50m and with all lift disposed earth to be levelled and neatly dressed:

215.62

-

149

... More
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L./Power consumption etc. complete.5 - 9 HP

200

-

104

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix (with graded stone aggregate 20mm nominal size).

10.78

-

3858

... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. M25

58.34

-

6440

... More
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.

169.06

-

56

... More
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level.

78.6

-

107

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :

379.04

-

204

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo-mechanically Treated bars (Conforming of relevent IS code)

2747.82

-

70

... More
Providing and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 metres center to center founded in M15 grade cement concrete 30cmx30cmx60cm, 0.6 metre below ground level, every 15th post, last but end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 of MoRT&H specification & type "A" as per IS : 278-1978 size designation 5 (line wire 2.24, point wire 2.00mm mass 97-106 g/m) includiing all material, labour.

1500

-

350

... More
Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

34112.4

-

1786

... More
P& F Bib cock (IS : 8931 mark), superior quality of approved make, with foam flow chrome plated with complete brass body including brass handle with wt 300 to 325 gm.15 mm nominal bore.

34112.4

-

271

... More
Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..

30701.33

-

172

... More
Add extra over item no 1.21 & 1.22 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

30701.33

-

40

... More
Survey of all properties, preparation of GIS based consumer mapping of consumer water connection database, plotting assets on GIS map etc (Satellite image will be provided by the Department)

34112

-

42.5

... More
Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.

34112

-

30

... More
Cost for basic service charges, Administration and Management, running of office, staff quarters, comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, IEC activities as per scope of work, cost of material required for maintenance & repairs, cost of lubricants, saltf for producing chorine, consumables spare parts (if the spare parts supplied to PHED are used in emergency) as per scope of work & items & conditions of contract no, amt will be paid for O&M in DLP

-

-

-

... More
For the 1st year of O&M after DLP

1

-

702005

... More
For the 2nd year of O&M after DLP

1

-

737097

... More
For the 3rd year of O&M after DLP

1

-

773959

... More
For the 4th year of O&M after DLP

1

-

812652

... More
For the 5th year of O&M after DLP

1

-

853288

... More
For the 6th year of O&M after DLP

1

-

895945

... More
For the 7th year of O&M after DLP

1

-

940750

... More
For the 8th year of O&M after DLP

1

-

987782

... More
For the 9th year of O&M after DLP

1

-

1037167

... More
For the 10th year of O&M after DLP

1

-

1089032

... More
Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.

-

-

-

... More
400 KL capacity

400000

-

5.61

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm dia (For Wash Out pipe)

15

-

1849.65

... More
350 mm dia (For Inlet Pipe)

15

-

7228.55

... More
400 mm dia (For Overflow Pipe)

15

-

8786.55

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
100 mm dia

1

-

9960

... More
350 mm dia

1

-

100494

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
100 mm dia

1

-

3160

... More
350 mm dia

1

-

15730

... More
Construction of Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge

-

-

-

... More
1200 mm x 900 mm x 1450 mm (upto 150 mm dia)

1

-

20987

... More
1500 mm x 1200 mm x 1550 mm (upto 350 mm dia)

1

-

29356

... More
Providing, installation, testing, trial run and commissioning of the following, as per specifications

-

-

-

... More
Horizontal Split Casing pumps & motor all other accessories of following duty conditions

-

-

-

... More
At Dimiya Dam route 43.4 LPS / 120 m head/84 KW (1W+1S)

168

-

4950

... More
MS Header pipe with all fittings such as flanges, bens, end plug etc. Size mm

-

-

-

... More
350 mm dia 6mm thk

7

-

5546

... More
MS suction pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.

-

-

-

... More
300 mm dia 6mm thk

6

-

3960

... More
MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-6mm thk

-

-

-

... More
250 mm dia 6mm thk

7

-

3691

... More
MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -

-

-

-

... More
250 mm dia 6mm thk

24

-

3691

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 (At Common and Individual Suction Side)

-

-

-

... More
300 mm dia

2

-

53559

... More
350 mm dia

1

-

100494

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. (At Individual Delivery pipe) Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
250 mm dia

2

-

153176

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.

-

-

-

... More
250 mm dia

2

-

13674

... More
300 mm dia

2

-

16909

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
350 mm dia

1

-

15730

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M, Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,BushBrass with EPDM/NBR "O" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. PN 1.6

-

-

-

... More
250 mm dia

2

-

47476

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. 50 mm Class PN 1.6

1

-

11637

... More
EOT of 5 ton capacity or as per design with all accessories for lateral & transverse movement

1

-

439590

... More
Glycerine filled pressure gauges (0-10 kg)

3

-

1280

... More
Providing, installation, testing, trial run and commissioning of the following, as per the specifications

-

-

-

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

... More
84 KW available Market Rating 90 KW

2

-

174567

... More
Earthing system complete for LT equipments

-

-

-

... More
For LT Panet & motors Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

1

-

5500

... More
Providing, installation, testing, trial run and commissioning of the following, as per specifications

-

-

-

... More
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
250 mm dia

1

-

155982

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Short body pasttern type double eccentric butterfly valve of approved make of following class & dia complete confirfing to BS-EN-593/ BS 51555 / IS 13095 / 1991 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 - F4 / IS 13095 drilled as per IS 1538. Electrostatic epoxy powder / fusion bounded epoxy coated with min thickness of 250 micorn appled on both body & disc inside & outside. Disc seal ring of EPDM / neoprene and disc seal ring of SS / CS. Shaft of SS - AISI - 304 / 316 & shaft bearings bronze / PTET or taflon with EPDM / NBR "O" ring seal , nut bolt confirming to IS 1363 & IS 1367. (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Motorized operated with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
250 mm dia

2

-

151954

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.

-

-

-

... More
250 mm dia

2

-

13674

... More
Construction of Flow meter chamber

3

-

113760

... More
Providing, installation, testing, trial run and commissioning of the following, as per specifications

-

-

-

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. Centrifugal Monoblock Pump set (Single Stage)

-

-

-

... More
At Bori RWR to Bori WTP route 45.5 LPS / 10 m head/8 KW (1W+1S)

2

-

67983

... More
At Bori RWR to Udai Vilas WTP route 18.06 LPS / 35 m head/12 KW (1W+1S)

2

-

93815

... More
MS Header pipe with all fittings such as flanges, bens, end plug etc. Size mm

-

-

-

... More
250 mm dia 6mm thk

7

-

3691

... More
400 mm dia 6mm thk

7

-

6325

... More
MS suction pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.

-

-

-

... More
200 mm dia 6mm thk

6

-

3479

... More
300 mm dia 6mm thk

6

-

3960

... More
MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-6mm thk

-

-

-

... More
150 mm dia 6mm thk

7

-

2816

... More
250 mm dia 6mm thk

7

-

3691

... More
MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -

-

-

-

... More
150 mm dia 6mm thk

24

-

2816

... More
250 mm dia 6mm thk

24

-

3691

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. At Common Suction Pipe and Individual Suction Pipe Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
200 mm dia

2

-

25341

... More
250 mm dia

1

-

42053

... More
300 mm dia

2

-

53559

... More
400 mm dia

1

-

131616

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. At Individual Delivery Pipe Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
150 mm dia

2

-

120432

... More
250 mm dia

2

-

153176

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.

-

-

-

... More
150 mm dia

2

-

9866

... More
200 mm dia

2

-

11167

... More
250 mm dia

2

-

13674

... More
300 mm dia

2

-

16909

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
250 mm dia

1

-

10111

... More
400 mm dia

1

-

21306

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M, Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,BushBrass with EPDM/NBR "O" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. PN 1.6

-

-

-

... More
150 mm dia

2

-

18052

... More
250 mm dia

2

-

47476

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. 40 mm Class PN 1.6

2

-

11225

... More
EOT of 5 ton capacity or as per design with all accessories for lateral & transverse movement

1

-

439590

... More
Glycerine filled pressure gauges (0-10 kg)

6

-

1280

... More
STAR DELTA STARTER 9.3 KW (12.5 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)

1

-

60615

... More
STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

1

-

91403

... More
For LT Panet & motors Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

2

-

5500

... More
Providing, installation, testing, trial run and commissioning of the following, as per specifications

-

-

-

... More
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
150 mm dia

1

-

125776

... More
250 mm dia

1

-

155982

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
150 mm dia

2

-

120432

... More
250 mm dia

2

-

153176

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.

-

-

-

... More
150 mm dia

2

-

9866

... More
250 mm dia

2

-

13674

... More
Cost for basic service charges, Administration and Management, running of office, staff quarters, comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, IEC activities as per scope of work, cost of material required for maintenance & repairs, cost of lubricants, saltf for producing chorine, consumables spare parts (if the spare parts supplied to PHED are used in emergency) as per scope of work & items & conditions of contract no, amt will be paid for O&M in DLP

-

-

-

... More
For the 1st year of O&M after DLP

1

-

44450

... More
For the 2nd year of O&M after DLP

1

-

46670

... More
For the 3rd year of O&M after DLP

1

-

49006

... More
For the 4th year of O&M after DLP

1

-

51456

... More
For the 5th year of O&M after DLP

1

-

54029

... More
For the 6th year of O&M after DLP

1

-

56730

... More
For the 7th year of O&M after DLP

1

-

59567

... More
For the 8th year of O&M after DLP

1

-

62545

... More
For the 9th year of O&M after DLP

1

-

65672

... More
For the 10th year of O&M after DLP

1

-

68956



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.