Public Health Engineering Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 64,040Document Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PHCJO_443787_2Tender No
NIT No. 74-75/2024-25Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phedwater.rajasthan.gov.in/phed
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
100
1252
125235
... More
Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr.
At Padarla, Padarli Turkan
40
1306
52272
... More
Deepening of existing tube well by DTH system beyond existing depth upto 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water. At Nadi Gaushala, Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Padarla, Padarli Turkan
5
8178
40890
... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes
-
-
-
... More
200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium,
151
2734
412834
... More
Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.
-
-
-
... More
200 mm dia nominal bore of 5.4mm thickness
At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana
61
317
19337
... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
-
-
-
... More
7.5 KW (10 HP) & head up to 120 mtr. At Nadi Gaushala Raikon Ki Dhani, Mukti Dham
15
8320
124800
... More
Up to 5.5 KW (7.5 HP) & head Up to 120 mtr.
At Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
27.5
9083
249782.5
... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
-
-
-
... More
Above 5 HP and up to 10 HP At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
7
24273
169911
... More
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
... More
3 core 6.0 Sq.mm
At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
1900
283
537700
... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
... More
16.0 Sq.mm, 4 core
At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana
400
234
93600
... More
16.0 Sq.mm, 4 core At Padarla, Padarli Turkan
120
324
38880
... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.
At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
14
696
9744
... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
7
986
6902
... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
760
678
515280
... More
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
-
-
-
... More
BFM 80 mm At Kulthana, Dhingana
2
12688
25376
... More
Providing & Fixing of Double Flanged, CI Body ISI Marked NRV of Approved Make of Following size At Nadi Gaushala Raikon Ki Dhani, Mukti Dham, Bangure Stadium, Kulthana, Dhingana, Padarla, Padarli Turkan
-
-
-
... More
65 mm dia At Padarli Turkan
7
2506
17542
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%