Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Jul 2024
Closing Date15 Jul 2024
Tender Amount₹ 7,18,000 
Notes
Download

Costs

  • EMD

    ₹ 14,360
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090620 With Microprocessor based release090623 630 Amp , 35/50 kA, adjustable O/L and adjustable S/C setting, Ics = 100 % Icu090623.2 Group - 1

4

112612

28153

... More
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090616 200 Amp , 25/35 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090616.2 Group - 1

4

51976

12994

... More
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090615 160 Amp , 25 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090615.2 Group - 1

2

14726

7363

... More
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090614 up to 125 Amp , 25 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090614.2 Group - 1

3

18450

6150

... More
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090613 up to 100 Amp , 25 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090613.2 Group - 1

12

57384

4782

... More
080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 Blue colour080802.2 Group - 1

20

5000

250

... More
080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080801 Red/yellow/Green colour080801.2 Group - 1

20

3000

150

... More
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081515 40 to 50 Amp081515.2 Group - 1

20

79000

3950

... More
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081513 32 Amp.081513.2 Group - 1

10

21500

2150

... More
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081512 13 to 25 Amp081512.2 Group - 1

15

14475

965

... More
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 Amp081704.2 Group - 1

5

10800

2160

... More
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 Amp081703.2 Group - 1

5

8000

1600

... More
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 Amp081702.2 Group - 1

15

17625

1175

... More
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081701 Up to 14 Amp081701.2 Group - 1

15

17625

1175

... More
Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc..

240

124320

518

... More
Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department

20

5600

280

... More
Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment)

-

-

-

... More
5 to 15 HP.

25

9275

371

... More
16 to 30 HP.

110

47520

432

... More
31 to 60 HP.

30

14040

468

... More
61 to 100 HP.

20

9360

468

... More
Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment)

-

-

-

... More
5 to 15 HP.

5

2400

480

... More
16 to 30 HP.

12

7116

593

... More
082000 P and F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required082003 One day and week reserve (digital type )082003.2 Group - 1

8

45968

5746



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.