Public Health Engineering Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Public Health Engineering Department - PHED Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Jul 2024
Closing Date15 Jul 2024
Tender Amount₹ 2,99,000
Costs
EMD
₹ 5,980Document Cost
₹ 200Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHCJA_403988_1Bid Award Id
ViewTender No
EE/PHED/HMH/2024-25/49Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phedwater.rajasthan.gov.in/phed
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent and heat resistant material having following current rating short circuit breaking capacity at 440/415 V 50 Hz O/L and S/C settings as per PWD specification for electrical Works conforming to IS/IEC 60947 P 2 2003 with front face and centralised adjustable trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal and vertical mounting without any adverse effect on electrical performance suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3 having positive isolation capability, push (test) to trip trip time less then 10 ms under s/c condition Breaking capacity Ics 100% Icu. U imp 8 KV rated insulation voltage 800 V provision for UVR shunt trip earth fault trip door interlock pad lock and rotary handle including making connections with lugs and spreaders etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure A attached with this BSR .
E090310 With Thermal Magnetic release
E090313 160 Amp 25 kA adjustable O/L and fixed S/C setting Ics 100 % Icu
2
12694
6347
SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent and heat resistant material having following current rating short circuit breaking capacity at 440/415 V 50 Hz O/L and S/C settings as per PWD specification for electrical Works conforming to IS/IEC 60947 P 2 2003 with front face and centralised adjustable trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal and vertical mounting without any adverse effect on electrical performance suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3 having positive isolation capability, push (test) to trip trip time less then 10 ms under s/c condition Breaking capacity Ics 100% Icu. U imp 8 KV rated insulation voltage 800 V provision for UVR shunt trip earth fault trip door interlock pad lock and rotary handle including making connections with lugs and spreaders etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure A attached with this BSR .
E090310 With Thermal Magnetic release
E090312 125 Amp 25 kA adjustable O/L and fixed S/C setting Ics 100 % Icu
2
10722
5361
081200 SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1 and 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required.081220 Heavy duty Three phase
440 V , 50 Hz capacitor (Bank)081220.2 Group - 1
50
27300
546
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081515 40 to 50 Amp081515.2 Group - 1
6
23700
3950
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081513 32 Amp.081513.2 Group - 1
6
12900
2150
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081512 13 to 25 Amp081512.2 Group - 1
25
24125
965
081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081511 Up to 12 Amp081511.2 Group - 1
20
12160
608
080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080801 Red/yellow/Green colour080801.2 Group - 1
20
3000
150
080500 SF of Current Transformer , with all necessary support in existing panel including connection etc. as required .080501 up to 150 / 5 Ratio , 5 VA , class 1 accuracy080501.2 Group - 1
5
1530
306
080400 SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.080410 Analog type ( 96 mm x 96 mm
)080411 Below 500 A080411.2 Group - 1
12
4500
375
080300 SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.080301 Analog type ( 96 mm x 96 mm )080301.2 Group - 1
6
3420
570
081800 P and F push button actuators and integral contact block of dia.
22.5 mm including making connection etc. as required.081802 Luminous type Red , Yellow, Green, Amber081802.2 Group - 1
18
3078
171
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to
40 Amp081704.2 Group - 1
8
17280
2160
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to
30 Amp081703.2 Group - 1
6
9600
1600
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to
20 Amp081702.2 Group - 1
15
17625
1175
081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081701 Up to
14 Amp081701.2 Group - 1
14
16450
1175
6.5 Supply and filling starter oil in oil immersed starters at site.
40
11520
288
6.3 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment)
6.3.3 31 to 60 HP.
3
1404
468
6.3 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment)
6.3.2 16 to 30 HP.
10
4320
432
6.3 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment)
6.3.1 5 to 15 HP.
25
9275
371
6.2 Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department
25
7000
280
6.1 Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc..
50
25900
518