Public Health Engineering Department Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date3 Feb 2025
Closing Date3 Mar 2025
Tender Amount₹ 6,00,000 
Notes
Download

Costs

  • EMD

    ₹ 12,000
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 500

Summary

Annual Rate Contract For Repairing Leakage In Various Size Of Pipeline And Removal Illegal Connection Under Jen Section Buchawas Taranagar 2 Under Sub Div. Taranagar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
80/90mm (BSR_Item_No_1.1.1.1)

1

262

262

... More
100/110mm (BSR_Item_No_1.1.1.1)

1

299

299

... More
125/140mm (BSR_Item_No_1.1.1.1)

1

364

364

... More
150/160/180mm (BSR_Item_No_1.1.1.1)

1

381

381

... More
200/225mm (BSR_Item_No_1.1.1.1)

1

640

640

... More
250/280mm (BSR_Item_No_1.1.1.1)

1

851

851

... More
300/315mm (BSR_Item_No_1.1.1.1)

1

851

851

... More
350mm (BSR_Item_No_1.1.1.1)

1

1123

1123

... More
400mm (BSR_Item_No_1.1.1.1)

1

1178

1178

... More
Add on above item no. 1 for B.T. Road (BSR_Item_No_1.1.2)

1

-

0.05

... More
Add on above item no. 1 for C.C. Road (BSR_Item_No_1.1.3)

1

-

0.1

... More
Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) (PHED/BSR/2010/8.0)

-

-

-

... More
500mm AC (BSR_Item_No_8.1)

1

725

725

... More
600 mm AC (BSR_Item_No_8.2)

1

858

858

... More
Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost) (PHED/BSR/2019/1.2)

-

-

-

... More
In all type Soil (BSR_Item_No_1.2.1)

-

-

-

... More
80mm (BSR_Item_No_1.2.1.1)

1

296

296

... More
100mm (BSR_Item_No_1.2.1.2)

1

334

334

... More
125mm (BSR_Item_No_1.2.1.3)

1

360

360

... More
150mm (BSR_Item_No_1.2.1.4)

1

432

432

... More
200mm (BSR_Item_No_1.2.1.5)

1

656

656

... More
250mm (BSR_Item_No_1.2.1.6)

1

1032

1032

... More
300mm (BSR_Item_No_1.2.1.7)

1

1032

1032

... More
350mm (BSR_Item_No_1.2.1.8)

1

1277

1277

... More
400mm (BSR_Item_No_1.2.1.9)

1

1442

1442

... More
Add on above item no. 2 for B.T. Road (BSR_Item_No_1.2.2)

1

-

0.05

... More
Add on above item no. 2 for C.C. Road (BSR_Item_No_1.2.3)

1

-

0.1

... More
Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost) (PHED/BSR/2019/1.3)

-

-

-

... More
In all type Soil (BSR_Item_No_1.3.1)

-

-

-

... More
50/63/75mm (BSR_Item_No_1.3.1.1)

1

181

181

... More
80/90mm (BSR_Item_No_1.3.1.2)

1

186

186

... More
100/110mm (BSR_Item_No_1.3.1.3)

1

221

221

... More
125/140mm (BSR_Item_No_1.3.1.4)

1

249

249

... More
150/160/180mm (BSR_Item_No_1.3.1.5)

1

249

249

... More
200/225mm (BSR_Item_No_1.3.1.6)

1

334

334

... More
250/280mm (BSR_Item_No_1.3.1.7)

1

611

611

... More
300/315mm (BSR_Item_No_1.3.1.8)

1

729

729

... More
350mm (BSR_Item_No_1.3.1.9)

1

833

833

... More
400mm (BSR_Item_No_1.3.1.10)

1

950

950

... More
Add on above item no. 3 for B.T. Road (BSR_Item_No_1.3.2)

1

-

0.05

... More
Add on above item no. 3 for C.C. Road (BSR_Item_No_1.3.3)

1

-

0.1

... More
Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit. (PHED/BSR/2019/1.5)

-

-

-

... More
In all type Soil (BSR_Item_No_1.5.1)

-

-

-

... More
75 mm (BSR_Item_No_1.5.1.1)

1

310

310

... More
90/80 mm (BSR_Item_No_1.5.1.2)

1

317

317

... More
110/100 mm (BSR_Item_No_1.5.1.3)

1

354

354

... More
140/125 mm (BSR_Item_No_1.5.1.4)

1

419

419

... More
180/160/150 mm (BSR_Item_No_1.5.1.5)

1

436

436

... More
225/200 mm (BSR_Item_No_1.5.1.6)

1

915

915

... More
250 mm (BSR_Item_No_1.5.1.7)

1

989

989

... More
300 mm (BSR_Item_No_1.5.1.8)

1

1044

1044

... More
Add on above item no. 5 for B.T. Road (BSR_Item_No_1.5.2)

1

-

0.05

... More
Add on above item no. 5 for CC Road (BSR_Item_No_1.5.3)

1

-

0.1

... More
Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree refill the pit from excavated sand by ramming it & upto ground level for entire job contractor will use his own T&P & labour. (PHED/BSR/2019/1.7)

1

254

254

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils (PWD BSR 2013/B1/1.8)

1

200

200

... More
Removing of uPVC Pipes Class- 3/ 4 already laid at various site with specials, valves, MS leackage Clip etc. with care. This includes the Excavation of Earth to be done by mannual means (Labours Only- No Mechanical Equipments) without damaging pipes, CID Joints, valves, specials etc and other material. Removed pipes and other material recieved during excavation will be clean and free from soil, carting from site and to be deposited in Store of Junior Engineer Concern. Minimum 75 to 80% of pipes will be recovered. After removing of pipes with care the excavating trenches to required length and depth with dewatering and filling of trenches with earth up to origional level and clearing of site complete job for: (Rates are Exclusive of Earth Work and WBM/ Chap/ Cement Concrete/ Bituminious Road cutting)- Pipes Nominal Dia. (mm) (PHED/BSR/e.m.f./2015 Shriganganagar)

-

-

-

... More
90mm class 3/4 (BSR_Item_No_4.1.3)

1

4

4.4

... More
110mm class 3/4 (BSR_Item_No_4.1.4)

1

6

6

... More
140mm class 3/4 (BSR_Item_No_4.1.5)

1

9

9

... More
160mm class 3/4 (BSR_Item_No_4.1.6)

1

12

12

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr.

-

-

-

... More
In all type of soil

-

-

-

... More
For HDPE pipe line dia up to 110 mm

1

82

82



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.