Public Health Engineering Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,58,000Document Cost
₹ 2,000Tender Fee
₹ 1,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_PHCJA_180325_1Bid Award Id
ViewTender No
NIT 31/2019-20 RWSS BHANDRAJTender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phedwater.rajasthan.gov.in/phed
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Coldtwisted deformed bars (IS : 1786).
3600
-
70
Centring & Shutering with plywood or steel sheets including stuting, propping bracing both ways with steel props and removel of from work for upto floor five level
walls (any thickness) including attached pilasters butterssess plinth and string cours
Add extra for shuttering in circular work (in respective centring and shuttering item
1300
-
325.2
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement for :-Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix
170
-
4350
Dry sinking of well true & vertical in all types of soil including sand, silt, clay, mixed upto 25% with gravel and river bed stones upto size 300 mm in any direction complete as per drawing and technical specification (depth from level of placing of cutting edge & internal dia, to be taken for measurement) rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level)
-
-
-
(a) For depth upto 5.00 Mtr
44
-
1229
(b) For depth above 5.00mtr upto 10.00 Mtr
44
-
1690
(c) For depth above 10.00mtr upto 15.00 Mtr
44
-
1997
Wet sinking of well in all type of strata (soil & boulders in any quantity) including required operations like chiseling, air and water jetting, hoist drives, skilled divers etc for removal of isolated obstructions and minor blasting if required and lifting of excavated material upto ground level, and spreading the same with ramming and watering within a radius of 50 m from the site of open well. Rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level)
-
-
-
for depth from 15.0 m to 20.0 mtr
44
-
4152
for depth from 20.0 m to 25.0 mtr
44
-
5008
for depth from 25.0 m to 30.0 mtr and above. 40 MTR
132
-
5865
Labour charges for horizontal boring 100 mm dia in open well in rocky strata with all types of rock cutting & drilling tools etc. including all T&P required for job including dewatering arrangement.
800
-
540
Providing & Lowering in tubewell ISI marked GI Pipe “B" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
80
-
515
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
-
-
-
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
11
-
6920
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 4.0 Sq.mm
180
-
137
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.
-
-
-
Above 5 HP and up to 10 HP
2
-
18290
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
10.0 Sq.mm, 4 core
50
-
173
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
1000
-
97
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
135
-
72
Wet sinking of well in all type of strata (soil & boulders in any quantity) including required operations like chiseling, air and water jetting, hoist drives, skilled divers etc for removal of isolated obstructions and minor blasting if required and lifting of excavated material upto ground level, and spreading the same with ramming and watering within a radius of 50 m from the site of open well. Rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level)
-
-
-
for depth from 25.0 m to 30.0 mtr and above.40 MTR
52
-
5865
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
500
-
97
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
-
-
-
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
5.5
-
6920
Providing & Lowering in tubewell ISI marked GI Pipe “B" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
15
-
515
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 4.0 Sq.mm
90
-
137
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.
-
-
-
Above 5 HP and up to 10 HP
1
-
18290
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
135
-
72
Wet sinking of well in all type of strata (soil & boulders in any quantity) including required operations like chiseling, air and water jetting, hoist drives, skilled divers etc for removal of isolated obstructions and minor blasting if required and lifting of excavated material upto ground level, and spreading the same with ramming and watering within a radius of 50 m from the site of open well. Rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level)
-
-
-
for depth from 25.0 m to 30.0 mtr and above. 40 MTR
64
-
5865
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
500
-
97
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
-
-
-
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
5.5
-
6920
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 4.0 Sq.mm
90
-
137
Providing & Lowering in tubewell ISI marked GI Pipe “B" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
15
-
515
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.
-
-
-
Above 5 HP and up to 10 HP
1
-
18290
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
135
-
72
Wet sinking of well in all type of strata (soil & boulders in any quantity) including required operations like chiseling, air and water jetting, hoist drives, skilled divers etc for removal of isolated obstructions and minor blasting if required and lifting of excavated material upto ground level, and spreading the same with ramming and watering within a radius of 50 m from the site of open well. Rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level)
-
-
-
for depth from 25.0 m to 30.0 mtr and above. 40 MTR
52
-
5865
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
500
-
97
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
-
-
-
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
5.5
-
6920
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 4.0 Sq.mm
90
-
137
Providing & Lowering in tubewell ISI marked GI Pipe “B" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
15
-
515
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.
-
-
-
Above 5 HP and up to 10 HP
1
-
18290
Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.
-
-
-
Nominal bore 200 mm dia.
60
-
1240
Construction of tube well after completion of drilling by rotary method & upto 150 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.
-
-
-
Nominal bore 200 mm dia.
120
-
1025
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes
-
-
-
200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
61
-
1841
Labour charges for making slots on blank pipes made of ERW MS black pipe of following sizes, the slotting should be as per IS:8110-2000 or as amended up to date.
-
-
-
200 mm dia nominal bore.
18
-
273
Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as amended up to date.
1
-
7056
Providing & laying ISI marked GI Pipe “A” (light) class as per IS:1239 part I 2004 or amended up to date for casing pipe for submersible cable external/internal work 40 mm dia complete in all respect.
10
-
290
Providing & Lowering in tubewell ISI marked GI Pipe “B" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
130
-
515
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.
-
-
-
50 mm dia
1
-
11201
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
-
-
-
200 mm dia
1
-
750
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
-
-
-
Up to 5.5 KW (7.5 HP) & head above 120 mtr.
5.5
-
7760
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.
-
-
-
Above 5 HP and up to 10 HP
1
-
18290
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 4.0 Sq.mm
280
-
137
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
10.0 Sq.mm, 4 core
50
-
173
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.
1
-
800
Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.
-
-
-
Demolishing cement concrete including disposal of material within 50 mtr. lead 1:3:6 or richer mix
12
-
505
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches ordrains (notexceeding 1.5min widthor10 sumon plan) including dressing of side sandrammingof bottoms, liftupto 1.5m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soils
-
-
161
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
Supply up to 110 mm dia. in coil & above 110 mm dia straight length in 6 M.
-
-
-
HDPE PE-80 PN-6
-
-
-
90 mm dia
5000
-
243
110 mm dia
800
-
360
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
-
-
-
MS pipe specials upto 600 mm dia (with minimum 5.0 mm thickness sheet)
750
-
119
Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated CI D/F Sluice valves of approved make (IS: 14846 amended upto date) PN 1.0 class of following dia complete(including jointing and jointing material) including all material, labour testing and commissioning along with pipe line as per TechnicalSpecifications and as per direction of Engineer
-
-
-
Category "B" (Makes / vendors other then Category "A" will beconsidered in category "B").
-
-
-
80 mm Dia
6
-
4250
100mm Dia
2
-
5690
Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as perls :1538 UPTO 300MM DIA.
4
-
6930
Providing and laying in position cement concrete including curing ,comption etc complete etc.complete in specified grade excluding the cost of centring and shuttring All work up to plinth level m,15 grade nominal mix 1:2:4 (1 cement:2 course sand:4 graded stone aggregate 40 mm nomical size
15
-
4370
Deepening of existing tube well by DTH system beyond existing depth upto 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water.
-
-
-
Nominal bore 200 mm dia.
280
-
1076
Providing & Lowering in tubewell ISI marked GI Pipe “B" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
75
-
515
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 4.0 Sq.mm
150
-
137
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements