Public Health Engineering Department Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date20 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 8,00,000 
Notes
Download

Costs

  • EMD

    ₹ 16,000
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
50/63/75mm

1

255

255

... More
80/90mm

1

262

262

... More
200/225mm

1

640

640

... More
250/280mm

1

851

851

... More
400mm

1

1178

1178

... More
450mm

1

1325

1325

1

1472

1472

... More
Add on above item no. 1.1.1 for B.T. Road

-

-

-

... More
Add on above item no. 1.1.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

-

-

-

... More
Add on above no. 1.1.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.

-

-

-

... More
Add on above no. 1.1.1 item if depth of pipeline is above 3.0 mtr.

-

-

-

... More
Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)

-

-

-

... More
In all type Soil

-

-

-

-

-

-

... More
100mm

-

-

-

... More
125mm

-

-

-

... More
150mm

-

-

-

... More
200mm

1

656

656

... More
250mm

1

1032

1032

1

1032

1032

... More
350mm

-

-

-

... More
400mm

1

1442

1442

... More
450 mm

1

2509

2509

... More
500 mm

1

3284

3284

... More
Add on above item no. 1.2.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above no. 1.2.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.

1

-

0.2

... More
Add on above no. 1.2.1 item if depth of pipeline is above 3.0 mtr.

1

-

0.3

... More
Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost)

-

-

-

... More
In all type Soil

-

-

-

... More
50/63/75mm

-

-

-

... More
80/90mm

1

186

186

... More
100/110mm

1

221

221

... More
125/140mm

1

249

249

... More
150/160/180mm

-

-

-

... More
200/225mm

1

334

334

... More
250/280mm

1

611

611

... More
300/315mm

1

729

729

1

833

833

1

950

950

... More
450 mm

-

-

-

... More
500 mm

1

1199

1199

... More
600 mm

1

1247

1247

... More
Add on above item no. 1.3.1 for B.T. Road

-

-

-

... More
Add on above item no. 1.3.1 for C.C. Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above no. 1.3.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.

1

-

0.2

... More
Add on above no. 1.3.1 item if depth of pipeline is above 3.0 mtr.

1

-

0.3

... More
Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost)

-

-

-

... More
In all type Soil

-

-

-

1

534

534

... More
100 mm

1

578

578

... More
125 mm

1

650

650

... More
150 mm

1

774

774

... More
200 mm

1

901

901

... More
250 mm

1

1261

1261

... More
300 mm

1

1559

1559

... More
350 mm

1

1989

1989

... More
400 mm

-

-

-

... More
450 mm

1

2468

2468

... More
500 mm

-

-

-

... More
600 mm

1

3204

3204

... More
Add on above item no. 1.4.1 for B.T. Road

1

-

0.05

... More
Add on above item no. 1.4.1 for CC Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no. 1.4.1 if depth of pipe line is above 1.5 mtr to 3.0 mtr

1

-

0.2

... More
Deduct on above item no. 1.4.1 if valve is fixed at plinth level / platform i.e. no excavation is required

-

-

-

... More
Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.

-

-

-

... More
In all type Soil

-

-

-

1

310

310

... More
90/80 mm

1

317

317

... More
110/100 mm

-

-

-

... More
140/125 mm

1

419

419

... More
180/160/150 mm

1

436

436

... More
225/200 mm

1

915

915

... More
250 mm

1

989

989

... More
300 mm

1

1044

1044

... More
Add on above item no. 1.5.1 for B.T. Road

1

-

0.05

... More
Add on above item no. 1.5.1 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

-

-

-

... More
Add on above item no. 1.5.1 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.

1

-

0.2

... More
Add on above item no. 1.5.1 if depth of pipe line is above 3.0 mtr.

1

-

0.3

... More
Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.

-

-

-

... More
In all type Soil

-

-

-

-

-

-

... More
100 mm

1

372

372

... More
125 mm

1

436

436

... More
150 mm

1

436

436

... More
225/200 mm

1

969

969

... More
250 mm

-

-

-

... More
300 mm

1

1097

1097

... More
Add on above item no. 1.6.1 for B.T. Road

1

-

0.05

... More
Add on above item no. 1.6.1 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no. 1.6.1 if depth of pipe line is above 1.5 mtr up to 3.0 mtr.

1

-

0.2

... More
Add on above item no. 1.6.1 if depth of pipe line is above 3.0 mtr

1

-

0.3

... More
Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour.

-

-

-

... More
Add on above item no. 1.7 for B.T. Road

1

-

0.05

... More
Add on above item no. 1.7 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no. 1.7 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr

1

-

0.2

... More
Removal of sluice valve in existing pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)

-

-

-

... More
In all type Soil

-

-

-

... More
80 mm dia pipe to 100mm

1

327

327

... More
125 mm dia pipe to 150mm

1

392

392

... More
200 mm dia pipe to 250mm

1

632

632

... More
300 mm dia pipe to 350mm

-

-

-

... More
400 mm dia pipe

1

1628

1628

... More
450 mm dia pipe

1

1767

1767

... More
500 mm dia pipe

1

1960

1960

... More
600 mm dia pipe

1

2387

2387

... More
Add on above item no. 1.8.1 for B.T. Road

-

-

-

... More
Add on above item no. 1.8.1 for CC Road Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no. 1.8.1 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr

1

-

0.2

... More
Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).

-

-

-

... More
In all type Soil

-

-

-

... More
80 mm to 110 mm

-

-

-

... More
125 mm to 165 mm

-

-

-

... More
200 mm to 300 mm

1

2368

2368

... More
Add on above item no. 1.9.1 for B.T. Road

1

-

0.05

... More
Add on above item no. 1.9.1 for CC Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no.1.9.1 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr

-

-

-

... More
Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).

-

-

-

... More
In all type Soil

-

-

-

... More
80 mm to 100 mm

1

1583

1583

... More
125 mm to 150 mm

1

1920

1920

... More
200 mm to 300 mm

1

2529

2529

... More
350 mm to 450 mm

-

-

-

... More
500 mm to 600 mm

1

3389

3389

... More
Add on above item no.1.10.1 for B.T. Road

1

-

0.05

... More
Add on above item no.1.10.1 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no.1.10.1 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr

1

-

0.2

... More
Labour charges for removal of complaint of polluted water supply to the consumers

-

-

-

... More
Survey of the locality of polluted water supply for preliminary assessment of source of pollution during supply hours

-

-

-

... More
Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. The rate includes all labour charges to complete the work for pipe size

-

-

-

... More
In all type Soil

-

-

-

... More
50 to 75 mm

1

420

420

... More
80-110 mm

-

-

-

... More
125 to 165 mm

-

-

-

... More
200 to 300 mm

1

909

909

... More
350 to 400 mm

1

1260

1260

... More
Add on above item no.1.12.1 for B.T. Road

1

-

0.05

... More
Add on above item no.1.12.1 for CC Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no. 1.12.1 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.

1

-

0.2

... More
Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution CI/DI/MS pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. The rate includes all labour charges to complete the work for pipe size

-

-

-

... More
In all type Soil

-

-

-

... More
80-100 mm

1

463

463

... More
125 to 150 mm

1

546

546

... More
200 to 300 mm

-

-

-

... More
350 to 450 mm

1

1298

1298

... More
Add on above item 1.13.1 for B.T. Road

1

-

0.05

... More
Add on above item no. 1.13.1 for CC Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.

1

-

0.15

... More
Add on above item no.1.13.1 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.

-

-

-

... More
Restoration of bitumen road by patch work of WBM using crushed / broken aggregate as per the standard specification and consolidation with hand rammer spreading and consolidation of binding material , cleaning of surface of WBM and providing of seal & tack coat as per site condition by using ready cold mix up to the satisfaction of engineer in charge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job.

1

681

681

... More
Restoration of cement concrete road including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compacting cement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction of engineer incharge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job.

1

1066

1066

... More
(4.7) Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

1

4811

4811

... More
(4.8) Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
(4.8.1) M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

1

6730

6730

... More
(4.8.2) Plain cement concrete pavement of M-30 Grade

1

7237

7237

... More
(4.9) Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)

-

-

-

... More
(4.9.1)     60 mm thick.

1

275

275

... More
(4.9.2)     80 mm thick.

1

298

298

... More
(4.9.3)     100 mm thick

1

332

332

... More
(4.12) Removing & Re-fixing of Bricks Kharbanja road by manual means for laying of pipe line, stacking of serviceable & unserviceable material separately, disposal of dismantled material lead upto 50 mtr. The Bricks interlocking be laid on average 12 mm thick bed of mud mortar and the joints to be filled with pointing in cement mortar 1:3. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the direction of Engineer in charge. The rates are inclusive of fixing of minimum 70 percent reusable Bricks and cost of required new First class FPS bricks (min. 10.5 Mpa) in place of damaged bricks, all lead and lift as per Technical Specifications and direction of Engineer in Charge.

-

-

-

... More
(4.12.1) Horizontal aligned Bricks

1

212

212

... More
(4.12.2) Vertical aligned Bricks

1

230

230

... More
(6.1) Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
(6.1.1) Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
(6.1.1.1) 80 mm HW

1

6397

6397

... More
(6.1.1.2) 100 mm HW

1

9096

9096

... More
(6.1.1.3) 125 mm HW

1

11701

11701

... More
(6.3) Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
(6.3.1) Class PN 1.0

-

-

-

... More
(6.3.1.1) 80 mm dia

1

6718

6718

... More
(6.3.1.2) 100 mm dia

1

8683

8683

... More
(6.3.1.3) 125 mm dia

1

11624

11624

... More
(6.4) Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
(6.4.1) Class PN 1.0

-

-

-

... More
(6.4.1.1) 80 mm dia

1

6329

6329

... More
(6.4.1.2) 100 mm dia

1

8138

8138

... More
(6.4.1.3) 125 mm dia

1

9965

9965

... More
(6.17) Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
(6.17.1) 80 mm dia

1

3258

3258

... More
(6.17.2) 100 mm dia.

1

3964

3964

... More
(6.17.3) 125 mm dia.

1

5018

5018

... More
(9.1) Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.

-

-

-

... More
(9.1.2) For Class-A loading

-

-

-

... More
(9.1.2.1) Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm

1

29800

29800

... More
(9.1.2.2) Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm

1

33500

33500

... More
(9.1.3) For in-campus Valve Chambers

-

-

-

... More
(9.1.3.1) Sluice valve chamber of size1.13m x0.85m x1.225m for pipe size-upto100mm

1

28800

28800

... More
(9.1.3.2) Sluice valve chamber of size1.17m x0.95m x1.37m for pipe size-from 125-to-150mm

1

32300

32300

... More
(Approved by CE (R) PHED Jaipur vide letter no. 1006-1008/. 15.5.2022) PVC Moulded couplter Prioviding and fixing unplasticised- PVC moulded couplet (for jointing AC pipe provided by department) conforming to IS:1359 type A including jointing with seal ring conforming to IS: 583 as per IS-1592-2003 or amended upto date for casing of tube well for following dia nominal bore, as per technical specification and direction of Engineer in charges.

-

-

-

... More
(1.1) 200mm dia

1

600

600

... More
(1.2) 250mm dia

1

700

700



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.