Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Water Storage And Supply
Eprocure
Opening Date15 Jan 2025
Closing Date24 Feb 2025
Tender Amount₹ 1,97,44,70,000 
Notes
Download

Costs

  • EMD

    ₹ 3,94,89,400
  • Document Cost

    ₹ 25,000
  • Tender Fee

    ₹ 2,500

Summary

Work Of Augmentation Of Urban Water Supply Scheme Of Jodhpur South Under Phed, City Circle Jodhpur Including 05 Years Oandm After 01 Year

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
350 mm dia

18

93544

1683792

... More
400 mm dia

4

123339

493356

... More
450 mm dia

9

156591

1409319

... More
500 mm dia

2

196252

392504

... More
600 mm dia

6

243762

1462572

... More
Class PN 1.6, Motorised Operated

-

-

-

... More
200 mm dia (Filter Beds Outlets)

3

160812

482436

... More
250 mm dia (Filter Beds Outlets)

4

176267

705068

... More
300 mm dia

6

198850

1193100

... More
350 mm dia

6

216062

1296372

... More
450 mm dia (Inlet Chamber)

1

284669

284669

... More
600 mm dia (Inlet Chamber)

1

368293

368293

... More
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
EFM 50 mm

2

92924

185848

... More
EFM100 mm

13

113454

1474902

... More
EFM 150 mm

26

139687

3631862

... More
EFM 200 mm

20

141972

2839440

... More
EFM 250 mm

37

177439

6565243

... More
EFM 300 mm

28

219283

6139924

... More
EFM 400 mm

35

275303

9635605

... More
EFM 450 mm

14

387167

5420338

... More
EFM 500 mm

3

424286

1272858

... More
Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6

-

-

-

... More
80 mm dia

1

3149

3149

... More
100 mm dia.

40

3666

146640

... More
125 mm dia.

10

4792

47920

... More
150 mm dia.

51

5758

293658

... More
200 mm dia.

31

8564

265484

... More
250 mm dia.

55

11729

645095

... More
300 mm dia.

51

14024

715224

... More
350 mm dia.

37

18247

675139

... More
400 mm dia.

41

24715

1013315

... More
450 mm dia

18

28756

517608

... More
500 mm dia

9

34191

307719

... More
600 mm dia.

1

48304

48304

... More
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
For Class-AA loading

-

-

-

... More
Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- for pipe size-up to 100 mm

34

36700

1247800

... More
Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm

41

40900

1676900

... More
Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm

76

52300

3974800

... More
Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm

114

65300

7444200

... More
Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm

10

89900

899000

... More
Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm

28

33500

938000

... More
Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm

96

43500

4176000

... More
Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.45 to 0.70 mm. (iii) Uniformity Coefficient not be more than 1.70 nor less than 1.30. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 5.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). Filter media (fine sand and coarse sand) should be processed through disintegrator and dust separator in automatic plant including screening of sand to desired specification and washing and cleaning of sand with water by aqua wash technology at quarry site. (For RGF)

-

-

-

... More
for 2.5 MGD WTP

42

4190

175980

... More
For 4.0 MGD WTP

55

4190

230450

... More
Providing and placing of new graded gravel as (i) Size of Gravel vary from 50 mm at the bottom to 2. to 5 mm at the top as detailed: (a) Passing 80 mm screen but held on 10 mm- 150 mm layer (b) Passing 25 mm screen but held on 10 mm- 50 mm layer (c) Passing 10 mm screen but held on 5 mm- 50 mm layer Passing (d) 5 mm screen but held on 2 mm- 50 mm layer (ii) The filter gravel shall be as spherical as possible, hard, clean and uniform in quality and also shall not contain such impurities as dirt and clay as per IS: 8419 (Part-I) for filter gravel specifications. The work also includes washing the gravel with required concentration of HCL acid and finally with water and placing the same in filter beds as per direction of Engineer- In- Charge and technical specification complete in all respect. The gravel shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) amended up to date. (For RGF)

50

3926

196300

... More
Supply and charging of filter media (Gravel) as per department specification including screaming, washing with 5% HCL solution to make Gravel (Size 4 to 6mm, 8 to 12mm, 10 to 20mm - Hard Coarse grit from approved quarry) free from silt, clay and other all impurities work to be executed as per scope of work fixed by the department at the time of tendering

60

2086

125160

... More
Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.20 to 0.30 mm. (iii) Uniformity Coefficient not be more than 5.0 nor less than 3.0. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 7.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). (ix) The sand should not contain more than 2% of calcium and manganese calculated as carbonate. Filter media (fine sand and coarse sand) should be processed through. Disintegrator and dust separator in automatic plant including screening of sand to desired. Specification and washing and cleaning of sand with water by aqua wash technology at quarry site. The sand shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) (Fine sand 0.2 to 0.3mm and coarse sand 1.0 to 1.7mm) (For SSF)

50

4190

209500

... More
Fixing of pipes for under drainage system including plugging pipes with CM 1:4 on one end and fixing other end in collecting channel with CM 1:4 with all Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia holes in pipes @15 cm c/c in zig-zag pattern and testing of under drainage system as per instruction of Engineer-in-charge.

200

32

6400

... More
Removing & Re-fixing of pipes for under drainage system including cleaning of one end plugged pipes and fixing /embedded in CM 1:4 on one end and fixing other end in collecting channel with CM 1:4 with all Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia holes if required in pipes @15 cm c/c in zig-zag pattern.

200

26

5200

... More
Making 4mm dia hole in pipes of under drainage system of filters duly drilled. Carriage of pipe from stacks to filter site, making two per rows on pipe and points of making holes in Zig-Zag pattern in two hold raw. Making 4mm dia holes with drill machine @ 15cm c/c in zig-zag pattern.

1000

2

2000

... More
Labour charges for screening of old sand (received from filter beds) through the standard sieves, washing the sand with HCL acid of required concentration as directed by the Engineer- In- Charge, so as to remove all the mud and other deposits from sand grains and then clean with water till the sand is as neat and clean that it impart no colour to clean while washing. It also includes placing this washed filter media (sand) in filter beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF)

50

915

45750

... More
Labour charges for screening of old gravel (received from filter beds) through the standard different sizes sieves for required sizes of gravel, washing the gravel with HCL acid of required concentration as directed by the Engineer- In- Charge, so as to remove all the mud and other deposits from gravel grains and then clean with water till the gravel is as neat and clean that it impart no colour to clean while washing. It also includes placing this washed gravel in filter beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF)

60

685

41100

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
80 mm dia

5

9137

45685

... More
100 mm dia

41

11554

473714

... More
125 mm dia

1

17087

17087

... More
150 mm dia

57

19109

1089213

... More
200 mm dia

39

29396

1146444

... More
250 mm dia

67.5

48781

3292717.5

... More
300 mm dia

53.5

62128

3323848

... More
350 mm dia

27.5

116573

3205757.5

... More
400 mm dia

35

152675

5343625

... More
450 mm dia

8

203807

1630456

... More
500 mm dia

7

262134

1834938

... More
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
150 mm dia

4

139701

558804

... More
200 mm dia

4

155351

621404

... More
250 mm dia

7

177684

1243788

... More
300 mm dia

3

193924

581772

... More
Supply of Chlorine Tonner as per specifications with rollers complete in all respect as per the direction of Engineer.

2

167900

335800

... More
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
0.75 KW (1.0 HP)

2

45388

90776

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
RWPH HLFP To CHOPASNI HLFP 2.5 MGD Q-79.48 Head-65m KW-90 2W+1S

3

858245

2574735

... More
RWPH HLFP To CHOPASNI HLFP 4 MGD Q-114.38 Head-65m KW-132 2W+1S

3

1159705

3479115

... More
LLFP WTP To TO Suthla ESR, GSR Route Q-39.02 Head-61m KW-55 1W+1S

2

492515

985030

... More
LLFP WTP To TO SECTOR-6 ESR,SECTOR-2 ESR ,DEV NAGAR ESR Q-82.27 Head-42m KW-75 1W+1S

2

672571

1345142

... More
LLFP WTP To TO CHARNA BHAKHAR GSR (P) , KAMLA NEHRU NAGAR GSR , SHIV MANDIR ESR Q-163.19 Head-59m KW-200 1W+1S

2

1338395

2676790

... More
LLFP WTP To TO SECTOR-8 ESR , SECTOR-10 ESR , SECTOR-11 ESR Q-78.21 Head-46m KW-75 1W+1S

2

672571

1345142

... More
Discharge 101 to 120 LPS and head 20 to 30 M

2

492515

985030

... More
LLFP WTP To TO MAHAVEERPURAM ESR (P) , SECTOR-23 ESR , SECTOR-21 ESR Q-165.73 Head-39m KW-132 1W+1S

2

990485

1980970

... More
Jhalamand WTP To Madhuvan Housing Board,PS-04 ESRs Route Q-186.14 Head-53m KW-200 1W+1S

2

1556866

3113732

... More
Jhalamand WTP To TO JHALMAND ESR (E) Q-28.87 Head-34m KW-22 1W+1S

2

242227

484454

... More
Jhalamand WTP To JHALMAND ESR (P) Q-45.79 Head-36m KW-37 1W+1S

2

417667

835334

... More
Jhalamand WTP To CMHO ESR (P) Q-39.5 Head-37m KW-30 1W+1S

2

285634

571268

... More
Discharge 61 to 70 LPS and head 20 to 30 M

2

327309

654618

... More
Discharge 201 to 220 LPS and head 20 to 30 M

2

858245

1716490

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

10

2259

22590

... More
150 mm

365

3249

1185885

... More
200 mm

85

4250

361250

... More
250 mm

180

5733

1031940

... More
300 mm

349

7314

2552586

... More
350 mm

156

8826

1376856

... More
400 mm

192.5

10729

2065332.5

... More
450 mm

159

12686

2017074

... More
500 mm

132

14908

1967856

... More
600 mm

40

19798

791920

... More
Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonry in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.

3380

5820

19671600

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.

2660

121

321860

... More
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
Outer dia of pipe 219.1 mm and thickness

145

1626

235770

... More
Outer dia of pipe 273 mm and thickness

-

-

-

... More
3.6 mm

115

2801

322115

... More
Outer dia of pipe 323.9 mm and thickness

100

3695

369500

... More
Outer dia of pipe 355.6 mm and thickness 4 mm

275

4062

1117050

... More
Outer dia of pipe 508 mm and thickness 8.8 mm

1000

12687

12687000

... More
Outer dia of pipe 610 mm and thickness 8.8 mm

500

15279

7639500

... More
Outer dia of pipe 273 mm and thickness 4 mm

200

3107

621400

... More
Outer dia of pipe 406.4 mm and thickness

-

-

-

35

4648

162680

... More
Outer dia of pipe 219.1 mm and thickness 4 mm

120

2485

298200

... More
Outer dia of pipe 323.9 mm and thickness 4.5 mm

100

4151

415100

... More
Outer dia of pipe 406.4 mm and thickness 5 mm

20

5796

115920

... More
Outer dia of pipe 457 mm and thickness 5 mm

40

6527

261080

... More
Outer dia of pipe 508 mm and thickness 5 mm

40

7263

290520

... More
Outer dia of pipe 610 mm and thickness 5.8 mm

40

10121

404840

... More
Outer dia of pipe 813 mm and thickness 7.1 mm

20

16525

330500

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
100 mm

91286

1464

133642704

... More
150 mm

51532

2082

107289624

... More
200 mm

31661

2554

80862194

... More
250 mm

34308

3307

113456556

... More
300 mm

17280

4221

72938880

... More
350 mm

12989

5140

66763460

... More
400 mm

6275

6269

39337975

... More
450 mm

3387

7398

25057026

... More
500 mm

2436

8835

21522060

... More
600 mm

3800

11563

43939400

... More
800 mm

2650

19885

52695250

... More
Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethylene including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge. Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface.

3767.95

1227

4623274.65

... More
Providing and applying 100% Solids, Rigid, DTM Polyurethane lining to internal surface of M.S. Pipe as per AWWA C222 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Polyurethane Coating shall be NSF/WARS/SS-375 approved for drinking water and minimum thickness of lining shall be 500 microns.

3663.48

643

2355617.64

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil

100474

200

20094800

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:

-

-

-

... More
Ordinary rock

133365.45

365

48678389.25

... More
Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer.

-

-

-

... More
500 mm dia.

1

51137

51137

... More
600 mm dia.

1

65372

65372

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.

-

-

-

... More
Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
40 mm dia

4

13021

52084

... More
50 mm dia

23

13499

310477

... More
80 mm dia

21

17236

361956

... More
100 mm dia

8

23449

187592

... More
150 mm dia

13

40162

522106

... More
200 mm dia

10

55019

550190

... More
Construction of RCC pillar for following size of air valves including earthwork excavation, RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
Air valve pillar for air valves size of 200mm dia

10

36500

365000

... More
Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

27316.06

757

20678257.42

... More
Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous courses

11867.01

416

4936676.16

... More
Granular courses

38721.76

296

11461640.96

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

10926.42

4678

51113792.76

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
Plain cement concrete pavement of M-30 Grade

16389.63

6497

106483426.11

... More
Construction of RCC pillar for following size of air valves including earthwork excavation, RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
Air valve pillar for air valves size of 80mm dia

35

19800

693000

... More
Air valve pillar for air valves size of 100mm dia

8

21800

174400

... More
Air valve pillar for air valves size of 150mm dia

13

30400

395200

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.

-

-

-

... More
300 mm Dia 8 mm thick casing pipe.

535

18353

9818855

... More
400 mm Dia 8 mm thick casing pipe .

185

20972

3879820

... More
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.

-

-

-

... More
j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 20 M

-

-

-

... More
800 KL capacity

800000

15

12576000

... More
900 KL capacity

4500000

15

68220000

... More
1500 KL capacity

3000000

12

38310000

... More
2000 KL capacity

2000000

11

23180000

... More
Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 22 M

-

-

-

... More
2000 KL capacity

2000000

11

23400000

... More
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).

-

-

-

... More
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm. Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx.

-

-

-

... More
Type IV ( 212.9 Sqm) At RWPS Chopasani

1

5210970

5210970

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-100 PN-6 75 mm dia

100

186

18600

... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
32 mm dia nominal bore Class-B

15

430

6450

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
Gun-metal 25mm nominal bore.

2

592

1184

... More
Gun-metal 50 mm nominal bore.

1

2280

2280

... More
Making connection of G.I. distribution branch with G.I. main including all fitting.

-

-

-

... More
25mm to 40 mm dia

2

630

1260

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-100 PN-6

-

-

-

... More
90 mm dia

66020

264

17429280

... More
110 mm dia

174319

442

77048998

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.

-

-

-

... More
HDPE PE-100 PN-6

-

-

-

... More
125 mm dia

31761

573

18199053

... More
140 mm dia

20611

713

14695643

... More
160 mm dia

26058

897

23374026

... More
180 mm dia

4295

1125

4831875

... More
200 mm dia

14246

1348

19203608

... More
225 mm dia

3092

1697

5247124

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
100 mm HW

18

8649

155682

... More
125 mm HW

7

11173

78211

... More
150 mm HW

12

13595

163140

... More
200 mm HW

7

22603

158221

... More
250 mm HW

6

35722

214332

... More
300 mm HW

3

45382

136146

... More
350 mm with Gear

5

86838

434190

... More
400 mm with Gear

5

113457

567285

... More
Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} medium of following sizes at site of work.

-

-

-

... More
100 mm dia NB (Thickness of pipe 4.5 mm & mass of tube 12.50 Kg/m)

285

1286

366510

... More
125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m)

20

1603

32060

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)

250

1933

483250

... More
Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work, but excluding the cost of pipe line.

1000

289

289000

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
80 mm dia

3

11584

34752

... More
100 mm dia

2

13362

26724

... More
125 mm dia

1

14224

14224

... More
150 mm dia

5

20940

104700

... More
200 mm dia

5

36510

182550

... More
250 mm dia

7

55072

385504

... More
300 mm dia

3

77472

232416

... More
350 mm dia

6

83217

499302

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.

-

-

-

... More
150 mm dia.

6

11445

68670

... More
200 mm dia.

6

12954

77724

... More
250 mm dia.

10

15849

158490

... More
300 mm dia.

4

19614

78456

... More
350 mm dia.

9

23698

213282

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

30

680

20400

30

872

26160

190

901

171190

... More
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
0.75 KW (1.0 HP)

3

40555

121665

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

500

121

60500

... More
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)

1600

126

201600

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

100

196

19600

... More
16.0 Sq.mm, 4 core

50

234

11700

... More
SITC DOL Starter type LT Panel of following rating, all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. complete as per Technical Specifications and as per direction of Engineer-In-Charge.

-

-

-

... More
STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2)

1

108534

108534

... More
STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2)

1

122057

122057

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.

-

-

-

... More
Note: Road cut and restoration is not part of this item and paid separately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

27460

1780

48878800

... More
Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..

41190

200

8238000

... More
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

16476

44

724944

... More
Demolishing mud phuska/ Lime dhar/ Kharanja in terracing and disposal of unserviceable material within 50 meters lead.

50

285

14250

... More
Dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. In Cement mortar.

7

641

4487

... More
Demolishing cement concrete including disposal of material within 50 meter lead : 1:3:6 or richer mix.

33

637

21021

... More
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50mtr lead

90

15

1350

... More
Random Rubble stone masonry for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall in : Cement Mortar 1:4 (1-Cement:4-Sand).

3

3182

9546

... More
Random Rubble stone masonry for superstructure above plinth level one storey height above 30 Cm. thick walls in : Cement Mortar 1:4 (1-Cement:4-Sand).

10

3824

38240

... More
Extra for facing as per design and detailed specifications including additional cost of stones over item No. 6.1 & 6.2 for :

-

-

-

... More
Course rubble facing First Sort.

15

618

9270

... More
Course rubble facing Second Sort.

15

491

7365

... More
Centering & shuttering with plywood or steel sheets includingstrutting, propping bracing both ways with steel props andremoval of formwork for upto floor five level for :Walls (any thickness) including attached pilasters,buttresses plinth and string course.

92

289

26588

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.

24

5609

134616

... More
Rough cast plaster upto 10m height above ground level with a mixture of sand and gravel or crushed stone from 6mm to 10mm nominal size dashed over and including the fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement

225

340

76500

... More
Extra for using white cement in place of ordinary cement in the top layer of the item of washed stone grit plaster.

200

36

7200

... More
Finishing with neat cement (Punning).

425

36

15300

... More
Pointing on stone masonary in cement sand mortar 1:3 (1-Cement:3-Sand) :

-

-

-

... More
Deep grooved pointing

200

220

44000

... More
Flush or ruled pointing.

125

124

15500

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm).

400

53

21200

... More
Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls (any thickness) including attached pilasters, coloumns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, plain window sills, fillets etc up to floor three level excluding the const centering and shuttering. IS 456-2000 1:1.5:3 (1Cement :1.5 Course Sand :3 Graded stone aggregate 20 mm nominal size

13

5451

70863

... More
Nano technology water proofing, thermal insulation protection coating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment.

425

1162

493850

... More
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint

0.6

2869

1721.4

... More
Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level up to 4.5 Mtr. height in R.S. Joists flats, tees, angles and channels.

170

81

13770

... More
Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of lines ,grades and cross sections,includes disposal of surplus material with all lifts and lead upto 1000 metre as per MoRT & H specification clause 301

-

-

-

... More
In Hard Rock for pipeline

1.2

1010

1212

... More
Reinforced Cement Concrete work in wall ( any thickness ), including attached pilasters, Buttresses, Plinth and string courses,fillets,columns,pillars,piers,abutments,posts and struts etc. upto two stories excluding cost of centring , shuttering, finishing and reinforcement

-

-

-

... More
R.C.C. 1:1⅟2:3( 1 cement:1⅟2 course:3 graded stone aggregate 20 mm nominal size)

-

-

-

... More
R.C.C. 1:1⅟2:3( 1 cement:1⅟2 course:3 graded stone aggregate 20 mm nominal size)

10.66

7380

78670.8

... More
Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for:

-

-

-

... More
Wall ( any thickness ) including attached pilasters, buttresses, plinth and string courses etc.

10

367

3670

... More
Reinforcement for R.C.C work at all levels including straightening, cutting, bending, placing in position and binding all complete.

-

-

-

... More
@100 Kg/cum of item No.3

-

-

-

... More
Hard drawn steel wire

-

-

-

... More
3 Cum*100

300

78

23550

... More
Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
MS pipe 450 mm dia (with minimum 10mm thicknesssheet) from bed No. 3 and 4 to 8 ML CWR

5102.34

156

795965.04

... More
Silt clearance of drains, channels and canals with lift 1.5 Mtr and lead upto 50 Mtr.

-

-

-

... More
2.5 MGD

171.25

384

65845.63

... More
4.00 MGD

209.09

384

80395.11

... More
For Pipeline

24

384

9228

... More
Demolishing R.C.C work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.

-

-

-

... More
Inlet Channel

2.54

930

2362.2

... More
Filter Inlet Channel

2.7

930

2511

... More
Channel

2.7

930

2511

... More
For Pipeline

24

930

22320

... More
Earthwork in excavation in foundation trenches etc including dressing of sides and ramming of bottom including getting out the excavated matrial, refilling after laying pipe/foundation and disposal of surlus excavated material at a lead of 50 mtr suitable site as per direction of Engineeer for following depths, below natural ground/road top level In hard rock (Blasting prohibited)

-

-

-

... More
Depth upto 1.5 m

-

-

-

... More
For Pipeline

24

1772

42528

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level:

-

-

-

... More
1:3:6 (1 Cement:3 fine/coarse sand :6 graded stone aggregate 40 mm nominal size)

0.43

4885

2100.55

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level:

-

-

-

... More
1:1½:3 (1 cement: 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

0.98

6340

6213.2

... More
Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for:

1.92

367

704.64

... More
Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for:

-

-

-

... More
Columns, pillars, piers, Abutments, Posts and Struts.

66.55

375

24956.25

... More
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

-

-

-

... More
2.4@37.3Kg/rmt=89.52

89.52

100

8996.76

... More
Repair to stone masonary in cement sand mortar 1:6 with old and new stone.

266

318

84588

... More
Repair to damaged cement plaster of stone chajja with CM 1 : 3 of required thickness on top & bottom as per existing pattern and making patta etc complete up to three floor level as per direction of Engineer in charge including all necessary scoffolding etc

313

633

198129

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. (iv) IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)

714

513

366282

... More
Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 3 in following steps i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush. iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day. v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. vi) Cure the plastered surface for 15 days

400

1568

627200

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.

-

-

-

... More
Thermo Mechanically treated bars

2450

77

188650

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)

-

-

-

... More
Hot rolled deformed bars (IS : 1139).

50000

77

3850000

... More
Replacing broken roofing slab in patches including lime terrace, ceiling plaster etc. including removal of broken slabs.

45

1844

82980

... More
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks

-

-

-

... More
Cement mortar 1 : 4 (1 cement : 4 coarse sand)

40

4469

178760

... More
Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey

20

327

6540

... More
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated „J‟ or „L‟ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2.0mm thick (Wt. 3.3 Kg./Mtr. Sq.)

180

911

163980

... More
Providing flat iron brackets 50x3mm size with necessary bolts, nuts and washers etc. for fixing asbestos cement/G.S. sheets gutters with purlins.

750

42

31500

... More
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.

75

617

46275

... More
Fixing standard steel glazed doors, windows and ventilators in walls with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10 x10 cm of 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including fixing of glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws (only steel windows with lugs, glass pane cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.)

90

278

25020

... More
4 Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineerin-charge.

1080

317

342360

... More
Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)

20

1977

39540

... More
Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000:

-

-

-

... More
1:1.5:3 (1Cement:1.5Course Sand :3Graded stone aggregate 20 mm nominal size

186.95

4915

918869.08

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. (iv) IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)

465

513

238545

... More
Replacing broken roofing slab in patches including lime terrace, ceiling plaster etc. including removal of broken slabs.

40

1844

73760

... More
Fixing standard steel glazed doors, windows and ventilators in walls with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10 x10 cm of 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including fixing of glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws (only steel windows with lugs, glass pane cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.)

90

278

25020

... More
4 Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineerin-charge.

317

1080

342360

... More
Providing and fixing 20 mm thick precast terrazo tiles ofapproved make, with marble chips of size upto 6mm laid overroof with neat cement slurry mixed with pigment to match theshade of the tiles, including cutting ,grinding rubbing withmachine complete on 20 mm thick bed of cement sandmortar 1 : 4.

80

350

28000

... More
Providing & fixing steel glazed doors, windows and ventilators shutters of standard rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. IS 1038 1983.complete in all respect direction of Engineer- in charge.

-

-

-

20

3099

61980

... More
Window Fixed

42

3090

129780

... More
STRUCTURAL STEEL WORK IN SINGLE SECTION FIXED WITH OR WITHOUT CONNECTING PLATE INCLUDING CUTTING HOISTING (HEIGJHT UPTO 10 M ) FIXING IN POSITION AND APPLYING A PRIMING COAT OF APPROVED STEEL PRIMER ALL COMPLETE

30000

72

2160000

... More
SUPPLYING AND FIXING IN CEMENT MORTAR WELDED HAND RAILING MADE OUT OF MS ROUNF OR SQURE BARS, FLATSETC. FOR STAIRCASE OR VERANDAH AS PER DESIGN COMPLETE IN ALL RESPECT (WOODEN OR PVC HAND RAILING TO BE PAID EXTRA WITH PRIMING COAT OF RED OXIDE

400

81

32400

... More
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.

5233.63

64

334952.32

... More
CARRIAGE OF MATERIALS-Earth, Sand, Lime, Morrum manure or sludge

-

-

-

... More
Lead up to 2 Km

17335.11

89

1542824.79

... More
NH/SH/Railway Crossing

-

-

-

... More
500 mm Dia 8 mm thick casing pipe .

35

23569

824915

... More
Chlorine Analyser : Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range:0.05 to 20 mg/l.

5

309833

1549165

... More
Providing, installation, testing and commissioning of Turbidity Analyser : Range - Selective 0 to 4000 NTU, Accuracy:+/-2% of reading or +/-0.02NTU; Compliance to US EPA180.1, With inbuilt transmitter with 4-20 mA output , Relay contacts & Modbus communication

5

205652

1028260

... More
Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67

36

23238

836568

... More
Providing, lowering, laying, aligning, fixing in position and jointing in pipe line, C.I. dual plate check valves as per API:594 and API:598 of PN 1.0 rating of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
300 mm dia

6

26700

160200

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.

-

-

-

... More
300 mm dia

6

20400

122400

... More
400 mm dia

6

36900

221400

... More
450 mm dia

2

38800

77600

... More
500 mm dia

1

53200

53200

... More
600 mm dia

1

69200

69200

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification in replacement of the existing backwash pumps along with the realignment of suction and delivery pipeline For backwash Tank

-

-

-

... More
294 cum/hr, 9 m head, 22 kW, 1W + 1S

2

1199400

2398800

... More
Providing, installation, testing and commissioning of D34, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, capacitors, etc, complete in all respect as per the scope of work & specifications . For Backwash

-

-

-

... More
Rating as above

44

4000

176000

... More
Supply, installation, testing and commissioning of Local Control Consoles/Push Button Stations for all motors

9

5200

46800

... More
Providing, lowering, laying, alinging, fixing in position in pipe line, manually operated Resilient Seated D/F Sluice valves of approved make & design standard PN 10 class of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
300 mm dia (Delivery)

6

50600

303600

... More
400 mm dia (Suction)

6

75100

450600

... More
450 mm dia (Suction Header & Rising Main)

3

131900

395700

... More
500 mm dia (Rising main)

2

134200

268400

... More
600 mm dia (Suction Header)

1

190200

190200

... More
Providing, installation of CI Tail Pieces, pipe pieces, flanges etc for butterfly/Sluice valves/Flowmeters in existing pipeline (CI Specials)

4000

98

392000

... More
Providing, installation of Mechanical Joints/ transition coupling joints for butterfly valves in existing pipeline

1

300000

300000

... More
Supply, installation, testing and commissioning of ultrasonic type LOH and ROF transmitter/indicator complete with all required accessories and in line with Technical Specifications

7

140000

980000

... More
Post-Chorination system (New) (1 W + 1 Stand Bye) Providing,installation, testing and commisioning of vacuum Feed Gas Chlorinator with all assessories and making connection with existing pipeline required including supply & instalation of trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM 'Y' type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity complete in all respect as per specifications/direction of engineer. For replacement of existing Gas Chalorinator 10 kg/hr

4

641400

2565600

... More
Supply, laying, termination of 1.1.Kv LT power cables complete with all acessories like lugs, glands, etc.

1

250000

250000

... More
Supply, laying, termination of 1.1.Kv LT instrumentation cables complete with all acessories like lugs, glands, etc.

1

150000

150000

... More
Overhauling, repair and refirbushment of air blowers, valves and sluice gates

1

350000

350000

... More
Replacement of sluice gates/shutters provided on feeding channel of clarifier of 2.5 MGD plant

4

225000

900000

... More
Supply and installation 1.5 Tonne Split AC of 5 star rating complete in all respect. Control room (at 2.5 MGD Filter plant)

1

40000

40000

... More
Supply of furniture of following items 1. Two tables, one revolving chair and 4 chairs

1

50000

50000

... More
Supply erection testing and commissioning of Horizontal Split Case centifugal Pumps , Motors and accessories of approved duty conditions as per scope of work and specifications.

6

2287080

13722480

... More
Spare parts for pump sets 25%

1

3430620

3430620

... More
Piping work for installation of pumps

1

300000

300000

... More
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to a lead of 50 meters from road boundary including removal and disposal of top organic soil not exceeding 150 mm in thickness as directed by Engineer.

-

-

-

... More
In area of light jungle

1

61600

61600

... More
In area of thorny jungle

2

81700

163400

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit to required compaction as per MoRT&H specification clause 201. (Measurement of girth to be done at height of 1 m above ground level)

-

-

-

... More
Girth from 300 mm to 600 mm

10

461

4615

... More
Girth from 600 mm to 900 mm

10

752

7520

... More
M- 20 Grade Concrete (1:1½:3 (1cement : 1 coarse sand : 3 graded stone aggregate 20 mm nominal size) - As per design mix)

-

-

-

... More
Inlet Channel

7.61

7380

56161.8

... More
Filter Inlet Channel

3.15

7380

23247

... More
Channel

6.3

7380

46494

... More
Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form of;

-

-

-

... More
Inlet Channel

135.36

367

49677.12

... More
Filter Inlet Channel

42

367

15414

... More
Channel

9

367

3303

... More
Channel

84

367

30828

... More
Reinforcement of R.C.C work at all levels including straightening, cutting, bending, placing in position and binding all complete.

-

-

-

... More
Thermo-Mechanically Treated bars. 100 Kg per cum of Item No. 2=10.15 Cum

1715.04

83

142862.83

... More
Sealing of cracks/ porous concrete with following by injection process through nipples including cost of material and labour complete as per drawing and technical specification complete.

-

-

-

... More
Cement grout as per clause 2800 & 2806 of MoRT&H specification.

286.3

256

73435.95

... More
Epoxy grout as per clause 2800 & 2803 of MoRT&H specification cwr hlfp

1719

1295

2226105

... More
Cement mortar (1:1) grout as per clause 2800 & 2806 of MoRT&H specification.

281.7

253

71270.1

... More
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. 3 MT Capacity Span 7 M and Lift 6 M

2

591400

1182800

... More
2 MT Capacity Span 7 M and Lift 6 M

2

482700

965400

... More
Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.

-

-

-

... More
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)

4500

153

688500

... More
2200 cum per hour Air Blowers coupled with suitable capacity 415V 3 phase 50Hz AC induction motor complete with base frame, suction air filter, silencer, pressure relief valve, delivery non return valve and with all required accessories

2

428040

856080

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

2

157854

315708

... More
pH Analyser: Transmitter : Range: 0-14 pH, Power Supply 230 VAC, Input: One Digital Sensor, Output: 4-20mA HART, IP66 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ flow through tee MOC SS.

2

108441

216882

... More
Water level indicator with 5 level indications, prons and cabling upto length of 5 metre

4

7662

30648

... More
Providing and fixing glazing in aluminium door, window, vintilator shutters and partitions etc. with PVS/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost. of aluminium snap beading shall be paid in basic item.) with glass panes of 4.0mm thickness (weight not less than 10.0 Kg/Sqm) as per IS : 2835

36

1041

37476

... More
Distempering with dry distemper of approved brand and manufacture shade on old work to give an even shade including all scaffolding and scrapping and necessary repairs complete.Colour change.

500

104

52250

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (One or more coats).

708

124

87792

... More
Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification.One or more coats on old work.

40

40

1632

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) PVC casing capping & it's accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.

-

-

-

... More
Short point (up to 3 mtr.)

20

368

7360

... More
Medium point (up to 6 mtr.)

24

592

14208

... More
Long point (up to 10 mtr..)

16

791

12656

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
On board

10

366

3660

... More
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits.

40

916

36640

... More
Supply of Chlorine Safety Equipment set comprising of the items Chlorine leak detector with two sensors, self contained compressed air breathing apparatus, safety shower with eye wash, emergency tonner repair kit, protective clothing such as PVC overall, gloves and rubber boots; complete as per detailed specifications & the directed of the Engineer.

2

283300

566600

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.

500

174

87000

... More
Removal of existing cement concrete wearing coat manually or with the help of jack hammers including its disposal within a lead of 1000 metres, complete as per technical specification without causing any detrimental effect to any part of the bridge structure as per clause 2809, 100 of MoRT&H Specification.

500

112

56250

... More
Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :

-

-

-

... More
25 mm thick

600

242

145200

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge.

250

930

232500

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.

-

-

-

... More
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

500

3731

1865500

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

1000

42

42000

... More
Guniting (Minimum density 2T/Cum.) on concrete/masonry surface with wire mesh size 50x50mm of wire thickness 3mm and cement mortar 1:3, applied with compressor after cleaning surface and applying with epoxy complete as per technical specification as per clause 2807 of MoRT&H Specification.

750

1218

913500

... More
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per technical specification including subsequent cutting/ removal and sealing of the holes as necessary of nipples after completion of grouting with cement/ Epoxy as per clause 2807 of MoRT&H Specification.

-

-

-

... More
Cement grout as per clause 2800 & 2806 of MoRT&H specification

1000

204

204500

... More
Patching of damaged concrete surface with polymer concrete and curing compounds, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer complete as per clause 2800 of MoRT&H specification.

750

756

567000

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :

-

-

-

... More
Arches, domes, vaults etc exceeding 6 Mtr span

764

329

251356

... More
Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof .

764

170

129880

... More
Providing and fixing of reinforced Ferro-Cement drain covers designed for 'A' class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc.

-

-

-

... More
Standard Size 600x800mm (75mm thick) for span 300 to 450mm

250

1583

395750

... More
Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1%

-

-

-

... More
0 - 8 Mtr

8

108441

867528

... More
GSB Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion.

-

-

-

... More
For Grading I Material

19360.88

1376

26640570.88

... More
WBM Grading 1 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete.

-

-

-

... More
Crusher broken - Grade-II (63-45mm)

19360.88

1915

37076085.2

... More
Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.

129072.53

33

4349744.26

... More
Extra for additional bitumen emulsion used in above item for every 1 kg per 10 sqm

129072.53

5

696991.66

... More
Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat.

-

-

-

... More
With Bitumen VG-grade 30

77443.52

119

9215778.88

... More
SEAL COAT ;-Providing and applying liquid seal coat type "A" comprising of a layer of bituminous binder @ 9.8 kg/ 10 Sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required) followed by a cover of stone chipping @ 0.09 cum/10 sqm of specified grading and rolling with power roller 8-10 tonne complete as per clause 513 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.

-

-

-

... More
With Bitumen VG-grade 30

77443.52

69

5343602.88

... More
Providing laying and consolidation Semi Dense Bituminous Concrete, as per Design Mix (approved by Engineer), on prepared surface with specified graded crushed aggregates as per table 500-15 for wearing coarse including loading of material with F.E. loader, hot mixing of stone aggregate, filler and bitumen (including Cost of anti-stripping compound Minimum 1% in Lime/Cement as per design wherever required) heating and mixing in in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa, to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 508 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding primer/tack coat.

-

-

-

... More
25-30 mm compacted thickness (Grade-2) using Bitumen VG-grade 30 @ 5% (percent by weight of total mix)

800.05

8740

6992437

... More
Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB's. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.

-

-

-

... More
800 mm dia 12 mm thick casing pipe

50

100200

5010000

... More
Providing and laying 50-75 mm compacted thick design mix (approved by Engineer) Dense Bituminous Macadam on prepared surface with specified graded crushed aggregates as per Table 500-9, 500-10 with bitumen binder set (including Cost of anti-stripping compound Minimum 1% in Lime/Cement as per design wherever required) for base/ binder course including loading of material with F.E. loader, heating and mixing of stone aggregate, filler and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control as per clause 504.3.5 to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 507 of MoRT&H specification but excluding primer/tack coat, including all material, labour, machinery, lighting, guarding and maintenance of diversion.

-

-

-

... More
Grade-II with Bitumen VG-grade 30 @ 4.25 %, lime filler @ 2% (percent by weight of total mix)

748.82

7530

5638614.6

... More
Campus Road

-

-

-

... More
Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301.

-

-

-

... More
In all type of soil

750

235

176625

... More
Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.

193.5

3070

594045

... More
PCC M-25

180

6120

1101600

... More
Horticulture Work

-

-

-

... More
Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking.

7.5

698

5235

... More
Edging with 2nd class bricks, laid dry lengthwise, including excavation, refilling, consolidation, with a hand packing and spreading nearly surplus earth within a lead of 50 metres.

100

40

4070

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

100

4

450

... More
Fine dressing the ground.

100

3

345

... More
Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately).

7.5

47

358.5

... More
Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.

-

-

-

... More
In rows 15 cm apart in either direction

100

37

3730

... More
Supply and planting following species best quality container grown healthy trees of 3 mt. min. height, well established & free from disease at site in 1.20 m dia holes, 1.20 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.

-

-

-

... More
Gulmhar, Neem, Neelli Gulmohar, Bottle Brush, Mango etc

40

1522

60880

... More
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerine filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminium

11

2941

32351

... More
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.

2

1100

2200

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

2

207482

414964

... More
Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.

36

20251

729036

... More
Supply, installation, testing & Commissioning of Copper wound distribution Transformer of following rating and % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled losses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core design including standard accessories like conservator with prismatic oil level gauge , silica gel breather, Bucholz relay, pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box, LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ), temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device, Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test in OEM's own lab shall be witnessed by Department engineer Physically. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .

-

-

-

... More
1000 KVA with % Impedance 5.0

2

2647833

5295666

... More
630 KVA with % Impedance 4.5

4

1966939

7867756

... More
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

6

104718

628308

... More
SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

3

32852

98556

... More
SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch

6

392000

2352000

... More
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity 99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 core 95.0 Sq.mm

300

1319

395700

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 core 50/70/95 Sq.mm

12

4932

59184

... More
3 core 50/70/95 Sq.mm

12

7217

86604

... More
SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries, FCBC ( Float cum boost charger)suitable for 415V +/-10%, 50 Hz , 1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled, free standing in Sheet Steel enclosure,SCR controlled , regulation +/-1% , Efficiency 75% on FLAC/ DC Instruments, Selector Switch ,Built in DC Distribution Board (6 No MCB), indication , control as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

3

138022

414066

... More
Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

40

8534

341360

... More
Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia. ‘B’ class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance as required.

18

1961

35298

... More
S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required.

-

-

-

... More
50 mm dia.

174

426

74124

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

300

201

60300

... More
32mm x6mm G.I. ( Hot Dipped ) Strip

300

251

75300

... More
50mm x 6mm G.I. ( Hot Dipped ) Strip

300

416

124800

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100mm x 50mm x 1.6mm

300

567

170100

... More
150mm x 50mm x 1.6mm

300

692

207600

... More
300mm x 50mm x 1.6mm

300

1079

323700

... More
Supplying and drawing PVC insulated & sheathed solid/ stranded copper conductor multi core control cable ISI marked (IS:1554) of 1.1 kV grade of approved make as per chapter E11,in existing surface or recessed conduit/ casing capping including making connections etc. as required.

-

-

-

... More
4 core, 1.5 sq. mm. armoured

4000

87

348000

... More
8 core, 1.5 sq. mm. armoured

600

136

81600

... More
8 core, 2.5 sq. mm. armoured

700

193

135100

... More
12 CORE, 1.5 sq. mm. armoured

1200

167

200400

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
400 SQMM, 3.5 CORE

2200

2774

6102800

... More
300 SQMM, 3.5 CORE

600

2165

1299000

... More
240 SQMM, 3 CORE

500

1776

888000

... More
185 SQMM, 3 CORE

250

1450

362500

... More
120 SQMM, 3 CORE

450

969

436050

... More
95 SQMM, 3 CORE

1050

748

785400

... More
70 SQMM, 3 CORE

250

558

139500

... More
35 SQMM, 3 CORE

400

326

130400

... More
25 SQMM, 3 CORE

200

250

50000

... More
4.0 SQMM, 3 CORE

2400

126

302400

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) nterconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee

120

6124

734880

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

260

556

144560

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485

6

6429

38574

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in-charge.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA

12

1613

19356

... More
C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA

6

2651

15906

... More
Providing & Fixing of Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
10 AMP

42

372

15624

24

439

10536

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Blue

18

174

3132

... More
Red/Gree/ white Colour

72

267

19224

... More
Red/Green

84

267

22428

... More
Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
Non luminous type

48

168

8064

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)

30

2094

62820

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,

6

40152

240912

... More
Extended Rotary Handle

6

2781

16686

... More
Mechanical Interlocking kit

4

7117

28468

... More
Auxiliary + Trip alarm contact

6

1675

10050

... More
Spreaders for 800A, 4 Pole MCCB

12

6936

83232

... More
SITC of Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, Instantaneous , earth fault (LSIG) with separate LED indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, provision of ZSI, Communication, Power metering module, Thermal memory , trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10000 upto 2000 A rating and 5,000 for 2500 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
1600 A Rating ,50 kA

3

261910

785730

... More
Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Shunt Trip Release

2

2853

5706

... More
Under voltage Release

2

4545

9090

... More
Auxiliary Contact 4 NO + 4 NC

2

5642

11284

... More
Breaker Control Switch (TNC)

2

1322

2644

... More
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)

800

383

306400

... More
Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
12 to 14 stage

42

20115

844830

... More
Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
up to 6 KVAR

4

1858

7432

... More
10 KVAR

23

2334

53682

... More
25 KVAR

8

3858

30864

... More
50 KVAR

7

11057

77399

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating

15

933

13995

... More
50/63 A rating

12

1419

17028

... More
125 A rating

15

6476

97140

... More
Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating

12

1254

15048

... More
Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating

12

580

6960

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

4

361240

1444960

5

329747

1648735

3

207482

622446

4

183890

735560

2

157854

315708

2

119619

239238

2

109242

218484

2

98135

196270

... More
S & F of Star delta Starter with MCB,Main and Aux Contactor,O/L Relay, L/R Selector Switch,3 Indicating lamps,Start-Stop Push Button ,ontrol MCB with panel with all accessories with following rating : 7.5 KW to 9.3KW

-

-

-

... More
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
7 Mtr., Poles with Octagonal Cross Section

24

13481

323544

... More
Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single arm overhang

24

1936

46464

... More
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.

-

-

-

... More
Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.

24

8142

195408

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
LED Street Light fixture with Minimum lumen output 8700 lm

24

5993

143832

... More
Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
180 x 180 x 91 mm

24

1535

36840

... More
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
32 mm Dia.

24

761

18264

... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
High Power LED Flood Light Minimum lumen output 10000 lm

12

4941

59292

... More
Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metr depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of OH tank and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.

6

16800

100800

... More
From 3.3 KW to 7.5 KW DOL Starter Feeder with MCB,Main and Aux Contactor,O/L Relay,L/R Selector Switch,3 Indicating lamps,Start-Stop Push Button ,Control MCB (Size : 600 (W) x 400 (H) x 600 (D)

3

24083

72249

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 102 No. DO 98 No. AI 22 No. AO 16 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (uto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 12 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot

3

1456362

4369086

... More
SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications

3

24776

74328

... More
Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification

-

-

-

3

83353

250059

... More
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum

11

3098

34078

... More
Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminum, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC

11

7848

86328

... More
Providing, installation, testing and commissioning of Level Switch ( Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum

-

-

-

... More
Rigid for lengths of up to 3 Mtr.

3

37370

112110

... More
SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %, as per detailed Technical specification, scope of work and direction of Engineer in charge.

-

-

-

... More
Measuring range 0.0 to 6.0 mtr

79

119106

9409374

... More
Welding Charges on New M.S Bar to Ex M.S. bar

1.15

35000

40250

... More
Add extra for MS box welding charges

1

87449

87449.98

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. (Replacement/New pump)

-

-

-

... More
Discharge 20 to 30 LPS and head 128 M

2

285640

571280

... More
Construction of RCC GSR of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) It shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing RCC stair from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are included in this work, provision for the same shall be taken separately.

-

-

-

... More
GSR 2000 KL Capacity at Chandna Bhakhar

2000000

4

9100000

... More
Construction of RCC (Flat slab type) Rectangular Clear Water Reservoir of following capacity as per the Scope of work and Technical specification,

-

-

-

... More
consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 at Chopasani LLFP of following capacity :-

-

-

-

... More
2250 KL

2250000

4

10935000

... More
SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:- i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.

24

2000

48000

... More
Heavy Duty AL & CU Lugs, Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements.

3

50000

150000

... More
11 KV & 33KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,covers ect.

3

200000

600000

... More
Opearation and Maintenance of Rising Main, Distribution network, OHSR, Pumping Machinary etc. created under AMRUT 2.0 of UWSS for a Period of Five Years

-

-

-

... More
1st Year

1

17112068

17112068.54

... More
2nd Year

1

17864247

17864247.38

... More
3rd Year

1

18616426

18616426.22

... More
4th Year

1

19725890

19725890

... More
5th Year

1

20703722

20703722.49



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.