Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Dec 2024
Closing Date16 Jan 2025
Tender Amount₹ 43,18,08,848 
Notes
Download

Costs

  • EMD

    ₹ 86,36,177
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 2,500

Summary

(05/2024-25) Water Supply Scheme For Augmentation Of Uwss Barmer, District Barmer Including 05 Years O And M After 01 Year Defect Liability Period Under Amrut 2.0

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
200 mm

5081

2554

12976874

... More
250 mm

8666

3307

28658462

... More
300 mm

1341

4221

5660361

... More
350 mm

416

5140

2138240

... More
400 mm

473

6269

2965237

... More
500 mm

1500

8835

13252500

... More
600 mm ( for old CWR and proposed CWR interconnection at kareli nadi Pumping station)

50

11563

578150

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-100 PN-6

-

-

-

... More
90 mm dia

1946

264

513744

... More
110 mm dia

29177

442

12896234

... More
HDPE PE-100 PN-10

-

-

-

... More
110 mm dia

1321

582

768822

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M.

-

-

-

... More
HDPE PE-100 PN-6

-

-

-

... More
125 mm dia

5187

573

2972151

... More
140 mm dia

3094

713

2206022

... More
160 mm dia

2672

897

2396784

... More
180 mm dia

2466

1125

2774250

... More
200 mm dia

2651

1348

3573548

... More
225 mm dia

233

1697

395401

... More
HDPE PE-100 PN-10

-

-

-

... More
140 mm dia

645

996

642420

... More
160 mm dia

670

1295

867650

... More
180 mm dia

506

1626

822756

... More
200 mm dia

835

1969

1644115

... More
225 mm dia

3005

2466

7410330

... More
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
Outer dia of pipe 219.1 mm and thickness 4.5 mm

162

2789

451818

... More
Outer dia of pipe 273 mm and thickness 5 mm

80

3870

309600

... More
Outer dia of pipe 323.9 mm and thickness 5.6 mm

112

5148

576576

... More
Outer dia of pipe 406.4 mm and thickness 6.3mm

20

7280

145600

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer in-charge.

-

-

-

... More
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)

1200

126

151200

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer in-charge.

-

-

-

... More
MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet)

500

134

67000

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid separately

-

-

-

... More
20 mm Diameter HDPE below the ground & 15 mm GI pipe class B above the ground

3660

1780

6514800

... More
Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..

18300

200

3660000

... More
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr

18300

44

805200

... More
Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.

-

-

-

... More
Nominal bore 250 mm dia.

3000

1782

5346000

... More
Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.

3000

2049

6147900

... More
Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.

300

1456

436800

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)

50

1933

96650

... More
250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m)

150

4473

670950

... More
Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.

90

379

34110

... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
11 KW (15 HP) & head above 120 mtr.

495

6577

3255615

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Above 15 HP and up to 20 HP

30

32117

963510

... More
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.

-

-

-

... More
3 core 6.0 Sq.mm

9900

283

2801700

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
16.0 Sq.mm, 4 core

900

234

210600

... More
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

30

3651

109530

... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set

60

696

41760

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.

-

-

-

... More
250 mm dia

30

1160

34800

... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
Class B 65 mm dia

4500

765

3442500

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

30

2506

75180

... More
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.

30

1243

37290

... More
Providing and Lowering of ISI mark PVC-U casing and screen pipe as per IS : 12818 : 2010 or amended up to date having pipe thickness as per IS code suitable for TW and DCB with threading , winding with superior quality of plastic mesh & rope in three layers with end cap complete as per technical specification and direction of Engineer In charge.

-

-

-

... More
Medium well casing pipe (CM) suitable for depth above 80 mtr and up to 250 mtr.

-

-

-

... More
250 mm nominal dia ( internal dia )

5850

1733

10138050

... More
Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} medium of following sizes at site of work.

-

-

-

... More
100 mm dia NB (Thickness of pipe 4.5 mm & mass of tube 12.50 Kg/m)

25

1286

32150

... More
125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m)

25

1603

40075

... More
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.

-

-

-

... More
j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 20 M

-

-

-

... More
500KL capacity

500000

16

8315000

... More
600KL capacity

600000

14

8892000

... More
600 KL capacity

600000

14

8892000

... More
800 KL capacity

800000

13

10592000

... More
800 KL capacity

800000

13

10592000

... More
800 KL capacity

800000

13

10592000

... More
800 KL capacity

800000

13

10592000

... More
Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4

-

-

-

... More
100 KL capacity

100000

7

795000

... More
Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.

-

-

-

... More
700 KL capacity

700000

5

3654000

... More
1000 KL capacity

1000000

4

4980000

... More
Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

226

2259

510534

... More
150 mm

88

3249

285912

... More
200 mm

122

4250

518500

... More
250 mm

260

5733

1490580

... More
300 mm

248

7314

1813872

... More
350 mm

157

8826

1385682

... More
Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

60

2146

128760

... More
150 mm

10

3087

30870

... More
200 mm

40

4038

161520

... More
250 mm

20

5446

108920

... More
300 mm

10

6948

69480

... More
400 mm

10

10193

101930

... More
450 mm

20

12052

241040

... More
500 mm

10

14163

141630

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil

24762.96

200

4952592

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:

-

-

-

... More
Ordinary rock

13257.4

365

4838951

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:

-

-

-

... More
Hard rock(blasting prohibited)

390.86

782

305652.52

... More
Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

5991.99

757

4535936.43

... More
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous courses

979.54

416

407488.64

... More
Granular courses

2938.61

296

869828.56

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

2406.79

4678

11258963.62

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
Plain cement concrete pavement of M-30 Grade

3605.19

6497

23422919.43

... More
Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) Note: If existing precast block used more than 70%, than for every 1% use above 70%, deduction of 1% in cost shall be done for every 1% use above 70%.

-

-

-

... More
    80 mm thick.

2732

298

814136

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.

-

-

-

... More
500 mm Dia 8 mm thick casing pipe .

80

23569

1885520

... More
600 mm Dia 10 mm thick casing pipe .

80

30211

2416880

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
Centrifugal Monoblock Pump set (Single Stage)

-

-

-

... More
7.5 KW (10 HP)

2

67514

135028

... More
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
1.5 KW (2.0 HP)

4

46501

186004

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
Discharge 20 to 30 LPS and head 41 to 50 M

2

285634

571268

... More
Discharge 31 t0 40 LPS and head 20 to 30 M (at ESR)

2

242227

484454

... More
Discharge 31 t0 40 LPS and head 31 to 40 M

2

285634

571268

... More
Discharge 51 to 60 LPS and head 31 to 40 M

2

417667

835334

... More
Discharge 71 to 80 LPS and head 61 to 70 M

2

858245

1716490

... More
Discharge 161 to 180 LPS and head 51 to 60 M

2

1338395

2676790

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
100 mm HW

10

8649

86490

... More
150 mm HW

8

13595

108760

... More
200 mm HW

6

22603

135618

... More
250 mm HW

2

35722

71444

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2- 1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-incharge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 Junction Valves

-

-

-

... More
100 mm

15

11554

173310

2

17087

34174

... More
150 mm

20

19109

382180

... More
200 mm

24

29396

705504

... More
250 mm

23

48781

1121963

... More
300 mm

8

62128

497024

... More
350 mm

2

116573

233146

... More
400 mm

2

152675

305350

... More
450 mm

1

203807

203807

... More
500 mm

2

262134

524268

... More
600 mm dia.

1

385252

385252

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6, Manually Operated with Gear

-

-

-

... More
250 mm dia

2

66241

132482

... More
300 mm dia

3

74691

224073

... More
350 mm dia

2

93544

187088

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
100 mm dia

2

13362

26724

... More
150 mm dia

4

20940

83760

... More
200 mm dia

4

36510

146040

... More
250 mm dia

4

55072

220288

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
40 mm dia

3

13021

39063

... More
50 mm dia

8

13499

107992

... More
100 mm dia

2

23449

46898

... More
Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure Reducing / Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body & Bonnet - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc - Flexible, non-wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM (FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M / AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316/410, raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316 ,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze ,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI-316 ,Throttling plug - Stainless Steel, AISI-304, Nut- Bolts - SS Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. insertion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Diaphragm Type Flow Control Valve With Electrical Actuator suitable for SCADA (PN 1.6 )

-

-

-

... More
100 mm dia

5

119999

599995

... More
150 mm dia

10

155111

1551110

... More
200 mm dia

4

181481

725924

... More
250 mm dia

5

260901

1304505

... More
300 mm dia

1

362386

362386

... More
400 mm dia

2

879489

1758978

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
100 mm dia.

31

3666

113646

... More
125 mm dia.

2

4792

9584

... More
150 mm dia.

50

5758

287900

... More
200 mm dia.

52

8564

445328

... More
250 mm dia.

49

11729

574721

... More
300 mm dia.

20

14024

280480

... More
350 mm dia.

5

18247

91235

... More
400 mm dia.

6

24715

148290

... More
450 mm dia.

1

28756

28756

... More
500 mm dia.

2

34191

68382

... More
600 mm dia.

1

48304

48304

... More
STAR DELTA STARTER 7.5 KW (10.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)

1

65077

65077

... More
STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2)

2

108534

217068

... More
STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2)

1

122057

122057

... More
Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.

-

-

-

... More
At Veanasar Nadi ESR for boostong pump

33.81

20251

684686.31

... More
At Railway Kua HW for Lal dungari ESR

33.81

20251

684686.31

... More
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done (100m-indira colony esr +200m-soori dungari HW +700m gajroopsagar HW)

840

5820

4888800

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

840

121

101640

... More
Construction of Pump house of RCC framed structure with pump pit in RCC walls as per scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. complete as per direction of Engineer-in-charge. The GA, structure, electrical, sanitary, P&ID, SLD to be prepared by the contractor and submitted to department for approval for earth quake zone II.

-

-

-

... More
Pump House with Monorail arrangement (for Dola Dungari GLSR boosting pump)

75.21

22320

1678687.2

... More
Pump House with Monorail arrangement (At Mahaveer Nagar HW)

75.21

22320

1678687.2

... More
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
For Class-AA loading

-

-

-

... More
Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-up to 100 mm

10

36700

367000

... More
Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm

25

40900

1022500

... More
Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm

56

52300

2928800

... More
Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm

4

65300

261200

... More
Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm

1

89900

89900

... More
For in-campus Valve Chambers

-

-

-

... More
Sluice valve chamber of size1.13m x0.85m x1.225m for pipe size-upto100mm

4

28800

115200

... More
Sluice valve chamber of size1.17m x0.95m x1.37m for pipe size-from 125-to-150mm

12

32300

387600

... More
Sluice valve chamber of size1.26m x1.185m x1.76m for pipe size-from 200-to-300mm

18

41700

750600

... More
Sluice valve chamber of size1.39m x1.43m x2.125m for pipe size-from 350-to-450mm

3

52700

158100

... More
Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
For Class-AA loading

-

-

-

... More
Air valve chamber of size0.9m x1m x1.695m for air valve size-from 50 mm-to-80mm

4

39600

158400

... More
Air valve chamber of size1m x1.1m x1.945m for air valve size of 100mm

2

45800

91600

... More
Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document.

-

-

-

... More
Solar panels more than 10 KW and up to 50 KW at a single location. (at zero point HW)

50000

57

2850000

... More
Solar panels more than 10 KW and up to 50 KW at a single location. (at Laxmi nagar PH)

20000

57

1140000

... More
Solar panels more than 10 KW and up to 50 KW at a single location. (at kareli Nadi PH)

20000

57

1140000

... More
Solar panels more than 10 KW and up to 50 KW at a single location. (at M.Nagar PH)

20000

57

1140000

... More
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
EFM100 mm

1

113454

113454

... More
EFM 150 mm

2

139687

279374

... More
EFM 200 mm

2

141972

283944

... More
EFM 250 mm

2

177439

354878

... More
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
BFM 80 mm

30

12688

380640

... More
BFM 150 mm

6

24022

144132

... More
BFM 200 mm

14

30414

425796

... More
BFM 250 mm

16

64440

1031040

... More
BFM 300 mm

7

86665

606655

... More
Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
65 mm dia

30

3538

106140

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
Short point ( up to 3 mtrr.)

4

368

1472

... More
Medium point ( up to 6 mtrr.)

4

592

2368

... More
Long point ( up to10 mtrr.)

4

791

3164

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
On board

3

366

1098

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
2 x 1.5 sq. mm

50

44

2200

... More
2 x 2.5 sq. mm

120

63

7560

... More
P & F 1.2 mm thick G. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (1.2 mm thick M. S. Sheet boxes )

-

-

-

... More
175mm x 100mm x 60mm

2

85

170

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (Single pole MCB (With B/C curve tripping Characteristics))

-

-

-

... More
6 A to 32 A rating

8

192

1536

... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
4 Way (4+2)

3

1840

5520

... More
Providing & Fixing of ISO certified company made TP&N 415 V AC23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
32 A rating

2

3937

7874

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BS

-

-

-

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

45

125

5625

... More
WBM Grading 1 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete.

-

-

-

... More
Crusher broken - Grade-II (63-45mm)

1469.3

1915

2813709.5

... More
Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.

9795.36

33

330103.63

... More
Extra for additional bitumen emulsion used in above item for every 1 kg per 10 sqm

9795.36

5

52894.94

... More
Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat.

-

-

-

... More
With Bitumen VG-grade 30

7403.58

119

881026.02

... More
SEAL COAT ;-Providing and applying liquid seal coat type "A" comprising of a layer of bituminous binder @ 9.8 kg/ 10 Sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required) followed by a cover of stone chipping @ 0.09 cum/10 sqm of specified grading and rolling with power roller 8-10 tonne complete as per clause 513 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.

-

-

-

... More
With Bitumen VG-grade 30

9795.36

69

675879.84

... More
Providing laying and consolidation Semi Dense Bituminous Concrete, as per Design Mix (approved by Engineer), on prepared surface with specified graded crushed aggregates as per table 500-15 for wearing coarse including loading of material with F.E. loader, hot mixing of stone aggregate, filler and bitumen (including Cost of anti-stripping compound Minimum 1% in Lime/Cement as per design wherever required) heating and mixing in in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa, to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 508 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding primer/tack coat

-

-

-

... More
25-30 mm compacted thickness (Grade-2) using Bitumen VG-grade 30 @ 5% (percent by weight of total mix) for Rising Route on Major Road

71.75

8740

627095

... More
Supply, Installation, testing and commissioning of Battery powered Electromagnetic flow meters with GSM/GPRS based with an accuracy of ± 1% of measured value, ingress protection Electronics IP 66 and flow tube IP 68, MOC: lining Neoprene rubber/Hard rubber/PTFE, Flange - SS316/SS304/MS/CS, Electrode - SS 316/Hastalloy, Coil Housing - SS, battery life of min. 5 years, LCD display 5 digit for instantaneous flow and 9 digit for Totalized flow as per technical specifications of following sizes: (For Existing ESRs, CWR & Proposed ESRs

-

-

-

... More
EFM 100 mm

3

137738

413214

... More
EFM 150 mm

10

161432

1614320

... More
EFM 200 mm

8

188645

1509160

... More
EFM 250 mm

5

277852

1389260

... More
EFM 300 mm

1

320000

320000

... More
EFM 350 mm

1

401137

401137

... More
EFM 400 mm

2

432362

864724

... More
Providing, lowering, laying, aligning, fixing in position CI Foot valves in pipe line as per IS:4038-1986 (amended upto date) suitable for potable water at all level/ depth including all material, labour hydraulic testing and commissioning as per technical specifications and as per direction of Engineer for following sizes:

-

-

-

... More
400 mm dia

2

59400

118800

... More
Supply, installation, testing & Commissioning of Copper wound distribution Transformer of following rating and % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled losses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core design including standard accessories like conservator with prismatic oil level gauge , silica gel breather, Bucholz relay, pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box, LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ), temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device, Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test in OEM's own lab shall be witnessed by Department engineer Physically. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .

-

-

-

... More
630 KVA with % Impedance 4.5

2

1966939

3933878

... More
SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
400 KVA with Off -LTC (+5% to - 10% @ 2.5%)

1

763331

763331

... More
SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
Non Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch

3

449019

1347057

... More
SITC of HT 33KV, 3Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Outdoor Non Extensible Fixed Type (IP54), RMU (Ring main unit) comprising of manually operated Load Break Switch and manual charging fixed-type Vacuum Circuit Breaker as per requirement, inside robotically welded stainless steel grade 304 (Non Ferrite Non Magnetic Grade) tank having of minimum thickness 2 mm with IP67 Degree of Protection and enhanced BIL of 170kVp internally to manage voltage surges. RMU should be provided with internal bus bars, as well as earthing bus bars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFLR 25kA/1 sec for tank and cable chamber as per IEC62271-200. RMU shall have on-site-repair ability features such as site replaceable bushing/ coupling/ mechanism and gas refilling at site. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing better ingress protection. The unit shall include the following with all necessary standard fittings as required at site. Load Break Switch module consisting of following accessories : 33kV, 630 Amp Load Break Switch module and integrated earthing switch, both with full making capacity. Short Circuit withstand capacity - 25kA/3-sec, Making Capacity – 62.5 kAp, Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 Nos, touch-proof screen separable termination kit (push on type) VCB Breaker module consisting of following accessories : 33 kV, 630 Amp fixed-type Vacuum Circuit Breaker module for making and breaking of fault current along with disconnector + Earth Switch of full making capacity. Short time current breaking capacity - 25KA/ 3 sec, Making Capacity – 62.5kAp, Auxiliary contacts - 1NO + 1NC VCB operating sequence must be O-0.3Sec-CO-3Min-CO and mechanical endurance confirms for minimum 10000 operations. touch-proof screen separable termination kit (push on type) Numerical based self-powered OC+EF Protection Relay, providing Over Current (min. setting 20%), Earth-Fault (min. setting : 10%) 03 Nos 50-100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc. CL5P10), installed away from bushings to prevent saturation of core. (CT Ratio my change according to change in Load) All modules should have Suitable site replaceable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/ testing/ replacement purposes. Cable covers with self-Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system (i) Capacitive voltage indication fixed type VPIS 28-45 kV (ii) One No. Operating Handle for Manual Operation and one no. manometer (iii) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturer’s directions (iv) Above switchgear shall confirm to all relevant IEC/IS Standards. (v) Vacuum interrupter should be of same make as RMU (vi) Cable bushing should be replaceable at site. (vii) Minimum 4 module should accommodate in one tank to avoid multiple coupling at site.

-

-

-

... More
Non Extensible 1 way RMU with 1 no. VCB & Direct Cable Entry

1

2854086

2854086

... More
Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections, testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014.

-

-

-

... More
500KVA

1

1771878

1771878

... More
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

4

104718

418872

... More
SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

32852

32852

... More
Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

50

8534

426700

... More
Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia. ‘B’ class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance as required.

42

1961

82362

... More
S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required.

-

-

-

... More
50 mm dia.

276

426

117576

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

550

201

110550

... More
32mm x6mm G.I. ( Hot Dipped ) Strip

550

251

138050

... More
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity 99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 core 95.0 Sq.mm

500

1319

659500

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . (11 kv End Termination Kit )

-

-

-

... More
3 core 50/70/95 Sq.mm (Indoor Type)

30

4932

147960

... More
3 core 50/70/95 Sq.mm (Outdoor Type)

30

7217

216510

... More
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity 99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . (33 KV End Termination Kit )

-

-

-

... More
3 core 185.0 Sq.mm

500

3145

1572500

... More
3 core 120/150/185 Sq.mm (Indoor Type)

6

8396

50376

... More
3 core 120/150/185 Sq.mm (Outdoor Type)

6

9172

55032

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
300 SQMM, 3.5 CORE

2000

2165

4330000

... More
35 SQMM, 3.5 CORE

300

356

106800

... More
25 SQMM, 3 CORE

150

250

37500

... More
35 SQMM, 3 CORE

500

326

163000

... More
95 SQMM, 3 CORE

150

784

117600

... More
120 SQMM, 3 CORE

150

969

145350

... More
240 SQMM, 3 CORE

400

1776

710400

... More
10 SQMM, 3 CORE

200

183

36600

... More
4.0 SQMM, 3 CORE

3500

126

441000

... More
Supplying and drawing PVC insulated & sheathed solid/ stranded copper conductor multi core control cable ISI marked (IS:1554) of 1.1 kV grade of approved make as per chapter E11,in existing surface or recessed conduit/ casing capping including making connections etc. as required.

-

-

-

... More
4 core, 1.5 sq. mm. armoured

1500

87

130500

... More
8 core, 1.5 sq. mm. armoured

1200

136

163200

... More
8 core, 2.5 sq. mm. armoured

1300

193

250900

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100mm x 50mm x 1.6mm

350

567

198450

... More
150mm x 50mm x 1.6mm

550

692

380600

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) nterconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee

140

6124

857360

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

160

556

88960

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Three phase Ammeter with Inbuilt Selector Switch

16

1731

27696

... More
Three phase Voltmeter with Inbuilt Selector Switch

13

1731

22503

... More
Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485

25

6429

160725

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in-charge.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Resin cast wound type CT

-

-

-

... More
C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA

24

1613

38712

... More
C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA

87

2651

230637

... More
Providing & Fixing of Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
10 AMP

54

372

20088

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

42

174

7308

... More
Blue / white Colour

66

267

17622

... More
Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
Non luminous type

20

168

3360

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)

60

2094

125640

... More
33 KV, class C 3 mm thick with proof voltage 36 KV AC (rms) for 3 min. and Break Down Voltage 65 KV AC (rms)

10

2374

23740

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
400Amp , 35 kA, adjustable O/L & adjustable S/C setting,

4

24442

97768

... More
630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,

3

35376

106128

... More
800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,

2

40152

80304

... More
Extended Rotary Handle

9

2781

25029

... More
Mechanical Interlocking kit

4

7117

28468

... More
Auxiliary + Trip alarm contact

9

1675

15075

... More
Spreaders for 400A, 4Pole MCCB

8

3179

25432

... More
Spreaders for 630A, 4Pole MCCB

6

3513

21078

... More
Spreaders for 800A, 4Pole MCCB

4

6936

27744

... More
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)

285

383

109155

... More
Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 to 8 stage

5

15370

76850

... More
Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
up to 6 KVAR

28

1858

52024

... More
10 KVAR

8

2334

18672

... More
20 KVAR

7

3606

25242

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating

46

933

42918

... More
Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating

24

1254

30096

... More
Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating

24

580

13920

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

2

109242

218484

2

183890

367780

2

251292

502584

... More
SITC of Variable Frequency Drives with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

1

629854

629854

... More
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
7 Mtr., Poles with Octagonal Cross Section

40

13481

539240

... More
Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single arm overhang

40

1936

77440

... More
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.

-

-

-

... More
Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.

40

8142

325680

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
LED Street Light fixture with Minimum lumen output 8700 lm

40

5993

239720

... More
Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
180 x 180 x 91 mm

30

1535

46050

... More
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
32 mm Dia.

40

761

30440

... More
Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metr depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of OH tank and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.

12

16800

201600

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 30 No. DO 26 No. AI 6 No. AO 2 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot

4

647272

2589088

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 86 No. DO 82 No. AI 18 No. AO 10 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 12 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot

3

1279834

3839502

... More
Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification

-

-

-

... More
1 KVA

7

52592

368144

... More
Supplying and drawing PVC insulated & sheathed solid/ stranded copper conductor multi core control cable ISI marked (IS:1554) of 1.1 kV grade of approved make as per chapter E11,in existing surface or recessed conduit/ casing capping including making connections etc. as required.

-

-

-

... More
12 CORE, 1.5 sq. mm. armoured

1800

167

300600

... More
Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1%

-

-

-

... More
0 - 5 Mtr.

4

74741

298964

... More
Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67

8

23238

185904

... More
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum

4

3098

12392

... More
GSB Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion.

-

-

-

... More
For Grading I Material

1469.3

1376

2021756.8

... More
Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminum, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC

4

7848

31392

... More
Providing, installation, testing and commissioning of Level Switch ( Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum

-

-

-

... More
Rigid for lengths of up to 3 Mtr.

4

37370

149480

... More
SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %, as per detailed Technical specification, scope of work and direction of Engineer in charge.

-

-

-

... More
Measuring range 0.0 to 6.0 mtr

27

119106

3215862

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

123.72

930

115059.6

... More
CARRIAGE OF MATERIALS-Building Rubbish Stone metal (Grit and ballast etc.) (up to 5 Km)

123.72

125

15465

... More
Dismantling CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into block, including stacking of pipes lead at site within 50 meter, of dia:

-

-

-

... More
Above 150mm dia. up to 300mm dia.

30

147

4410

... More
Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:

7.31

700

5117

... More
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:

-

-

-

... More
In cement mortar.

47.77

641

30620.57

... More
Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:

-

-

-

... More
Of area 3 square meter and below.

7.76

105

814.8

... More
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.

1048.98

15

15734.7

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
1: 3: 6 or richer mix.

54.65

637

34812.05

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils

23.12

178

4115.36

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.

-

-

-

... More
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

3.27

3847

12579.69

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix

4.23

5609

23726.07

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix

2.73

5185

14155.05

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :

-

-

-

... More
Walls (any thickness) including attached pilasters, buttresses plinth and string course.

33.56

289

9698.84

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)

-

-

-

... More
Thermo-mechanically Treated bars (Conforming of relevent IS code)

517

77

39809

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :: 12 mm thick.

569.68

163

92857.84

... More
Distempering with dry distemper of approved brand and shade (two or more coats) and of required shade on new work, over and including, priming coat of whiting to give an even shade including all scaffolding.

279

53

14787

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:

-

-

-

... More
New work (Two or more coats applied @ 3.84 kg/10 sqm).

201.88

53

10699.64

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Two or more coats on new work

55

69

3795

... More
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :

-

-

-

... More
Partly fixed and partly openable [ fixed area not to exceed 33%]

3.6

3090

11124

... More
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.

3.6

617

2221.2

... More
Providing and fixing Square bars or other flat welded to window, ventilatiors etc.

33.6

65

2184

... More
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint

4

2869

11476

... More
Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames)

-

-

-

... More
Using M.S. angles 40 x 40 x 6mm for diagonal braces.

6.25

3141

19631.25

... More
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)

-

-

-

... More
For area of each slab from 901 to 2000 Sq.Cm :

22.75

950

21612.5

... More
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).

-

-

-

... More
For fixed portion

-

-

-

... More
Powder coating aluminum ( minimum thickness of powder coating 50 micron)

75

351

26325

... More
For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).

-

-

-

... More
Powder coating aluminum ( minimum thickness of powder coating 50 micron)

75

381

28575

... More
Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.

-

-

-

... More
Prelaminated particle board with decorative lamination on both sides.

18

1092

19656

... More
Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.)

-

-

-

... More
With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm)

9

902

8118

... More
With float glass panes of 8 mm thickness

6.25

1235

7718.75

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.

-

-

-

... More
With stainless steel cover plate

2

1426

2852

... More
Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.

-

-

-

... More
Powder coating aluminum ( minimum thickness of powder coating 50 micron)

27

1843

49761

... More
S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding.

27

925

24975

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). (without vibrator)

2

4624

9248

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:

180

81

14580

... More
Providing and fixing 50mm thick cement concrete flooring with Metallic concrete hardener topping, under layer of 38mm thick cement concrete 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm thick nominal size) and top layer of 12mm thick metallic concrete hardener consisting of mix 1:2 (1 cement : 2 stone aggregate, 6mm nominal size) by volume & mixed with metallic hardening compound of approved quality @ 2Kg./Sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete.

52.25

453

23669.25

... More
Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required.

-

-

-

... More
Diameter 900 mm

50

266

13300

... More
Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with 40 mm thickness

-

-

-

... More
Diameter 900 mm

25

766

19150

... More
Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-

-

-

-

... More
Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect.

5

27322

136610

... More
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand)

10.21

4263

43525.23

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :

-

-

-

... More
Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.

11.25

340

3825

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)

-

-

-

... More
Hot rolled deformed bars (IS : 1139).

140.4

77

10810.8

... More
Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids

-

-

-

... More
Size 9 to 12 mm

2.25

1997

4493.25

... More
Size 3 to 5 mm

2.25

2928

6588

... More
Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.

2.25

3727

8385.75

... More
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make

-

-

-

... More
75 mm dia

300

167

50100

... More
110 mm dia

200

336

67200

... More
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make

-

-

-

... More
Coupler

-

-

-

... More
75mm dia

30

72

2160

... More
110mm dia

20

108

2160

... More
Door Bend 87.5 Dg.

-

-

-

... More
75mm dia

30

124

3720

... More
110mm dia

10

193

1930

... More
Single Tee

-

-

-

... More
75mm dia

20

120

2400

... More
110mm dia

10

210

2100

... More
Pipe Clip

-

-

-

... More
75mm dia

100

18

1800

... More
110mm dia

20

31

620

... More
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.

-

-

-

... More
160 mm dia

120

463

55560

... More
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:

-

-

-

... More
Bend 87 .5

-

-

-

... More
160 mm dia

20

177

3540

... More
Supply & lowering air line of 25mm dia, G.I. pipe 'B' class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc.

10

300

3000

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).

-

-

-

... More
50mm dia nominal bore (dewatering)

60

757

45420

... More
Supply, installation, testing and commissioning of GSM /GPRS/ Cloud based data transmitter for Bulk Flowmeter (woltman Magnetic Pulse Output only ), Battery Powered -3VDC to12VDC , battery life 3-5 Years, Inbuild Memory fuction upto 2gb micro SD card supported to stroe the data in the absense of availabe mobile network, (1 no Data transmit in a day on cloud system), Encloser- ABS Protection-IP67/68, Operating tempreature -50-55 Deg. C. The DMA Inlet Flow Data shall be transmitt to the Respective MCC ROOM.

43

32500

1397500

... More
Cost for Basic Service Charges, Administration and Management, Running of Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 5 year after defect laibility period of one year DLP (except power feeder, IEC & miscllenous provision) for Water Supply Project

-

-

-

... More
For the 1st Year of O&M after DLP

1

3721263

3721263.39

... More
For the 2nd Year of O&M after DLP

1

3907326

3907326.56

... More
For the 3rd Year of O&M after DLP

1

4102692

4102692.89

... More
For the 4th Year of O&M after DLP

1

4307827

4307827.53

... More
For the 5th Year of O&M after DLP

1

4523218

4523218.91



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.