Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Construction Material
Machinery and Tools
Pipe Line Project
Eprocure
Opening Date7 Mar 2024
Closing Date13 Mar 2024
Tender Amount₹ 1,00,00,000 
Notes
Download

Costs

  • EMD

    ₹ 2,00,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
150 mm

-

2082

2082

... More
200 mm

-

2554

2554

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
100 mm

-

1670

1670

... More
150 mm

-

2384

2384

... More
200 mm

-

3037

3037

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-80 PN-6

-

-

-

... More
63 mm dia

-

171

171

... More
75 mm dia

-

217

217

... More
90 mm dia

-

306

306

... More
110 mm dia

-

463

463

... More
HDPE PE-100 PN-6

-

-

-

... More
63 mm dia

-

145

145

... More
75 mm dia

-

186

186

... More
90 mm dia

-

264

264

... More
110 mm dia

-

442

442

... More
HDPE PE-80 PN-10

-

-

-

... More
90 mm dia

-

449

449

... More
110 mm dia

-

675

675

... More
HDPE PE-100 PN-10

-

-

-

... More
90 mm dia

-

391

391

... More
110 mm dia

-

582

582

... More
De-jointing and removing of already laid CI/DI pipes of following diameters in excavated trenches with care, without damaging pipes, CID joints, valves, specials etc. and other materials and then refilling of soil after de-laying and de-jointing of pipelines with proper compaction and disposing of all surplus soil as directed with in a lead of 30 mtr. This also include stacking the pipes with care and transporting the same to div./sub div. store or as directed by EIC with in the division. (Rates are Exclusive of Earth Work)

-

-

-

... More
80 mm

-

45

45

... More
100 mm

-

50

50

... More
125 mm

-

50

50

... More
150 mm

-

59

59

... More
200 mm

-

79

79

... More
Laying, Jointing, Testing and Commissioning of Ductile Iron (DI) Pipes of any class in assorted length with specials, valves etc. including local handling and transportation from PHED store and then refilling of soil with proper compaction and disposing of all surplus soil as directed with in a lead of 30 mtr as per satisfaction of EIC. (Rates are Exclusive of Earth Work and jointing materials)

-

-

-

... More
80 mm

-

48

48

... More
100 mm

-

50

50

... More
125 mm

-

52

52

... More
150 mm

-

64

64

... More
200 mm

-

80

80

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid separately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

-

1658

1658

... More
Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid separately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

-

1986

1986

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.

-

-

-

... More
Note: Road cut and restoration is not part of this item and paid separately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

-

1780

1780

... More
P & F Bib cock (IS : 781 mark), superior quality of approved make , brass 400 gm, 15 mm nominal bore.

-

311

311

... More
P & F Bib cock (IS : 8931 mark), superior quality of approved make, chrome plated with complete brass body including brass handle with wt. 300 to 325 gm.15 mm nominal bore.

-

311

311

... More
Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..

-

200

200

... More
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

-

44

44

... More
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm ISI marked PN16 SDR 7.4 (IS:15801:2008) PPR-C (Three layered) pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

-

57

57

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil

-

200

200

... More
Add extra for trenches for every additional lift over item no 4.1

-

-

-

... More
Above 1.5 mtr and up to 3.0 mtr.

-

20

20

... More
Above 3.0 mtr and up to 4.5 mtr.

-

39

39

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:

-

-

-

... More
Ordinary rock

-

365

365

... More
Hard rock (requiring blasting)

-

546

546

... More
Hard rock(blasting prohibited)

-

782

782

... More
Add extra for trenches for every additional lift over item no 4.3

-

-

-

... More
Above 1.5 mtr and up to 3.0 mtr.

-

37

37

... More
Above 3.0 mtr and up to 4.5 mtr.

-

73

73

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

-

757

757

... More
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous courses

-

416

416

... More
Granular courses

-

296

296

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

4678

4678

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

-

6162

6162

... More
Plain cement concrete pavement of M-30 Grade

-

6497

6497

... More
Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) Note: If existing precast block used more than 70%, than for every 1% use above 70%, deduction of 1% in cost shall be done for every 1% use above 70%.

-

-

-

... More
    60 mm thick.

-

275

275

... More
    80 mm thick.

-

298

298

... More
    100 mm thick

-

332

332

... More
Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work, but excluding the cost of pipe line.

-

289

289

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.

-

-

-

... More
300 mm Dia 8 mm thick casing pipe.

-

18353

18353

... More
400 mm Dia 8 mm thick casing pipe .

-

20972

20972

... More
500 mm Dia 8 mm thick casing pipe .

-

23569

23569

... More
600 mm Dia 10 mm thick casing pipe .

-

30211

30211

... More
700 mm Dia 10 mm thick casing pipe .

-

33457

33457

... More
Removing & Re-fixing of Bricks Kharanja road by manual means for laying of pipe line, stacking of serviceable & unserviceable material separately, disposal of dismantled material lead up to 50 mtr. The Bricks interlocking be laid on average 12 mm thick bed of mud mortar and the joints to be filled with pointing in cement mortar 1:3. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the direction of Engineer in charge. The rates are inclusive of fixing of 80 percent reusable Bricks and cost of required new First class FPS bricks (min. 10.5 Mpa) in place of damaged bricks, all lead and lift as per Technical Specifications and direction of Engineer in Charge. Note: If existing bricks used more than 80%, than for every 1% above 80% use, deduction of 1% in cost shall be done for every 1% use above 80%.

-

-

-

... More
Horizontal aligned Bricks

-

212

212

... More
Vertical aligned Bricks

-

230

230

... More
Pump sets

-

-

-

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
Centrifugal Monoblock Pump set (Single Stage)

-

-

-

... More
2.2 KW (3.0 HP)

-

34070

34070

... More
3.7 KW (5.0 HP)

-

43760

43760

... More
5.5 KW (7.5 HP)

-

55225

55225

... More
7.5 KW (10 HP)

-

67514

67514

... More
9.3 KW (12.5 HP)

-

78860

78860

... More
11.0 KW (15 HP)

-

83148

83148

... More
15.0 KW (20.0 HP)

-

108825

108825

... More
18.5 KW (25.0 HP)

-

143629

143629

... More
Centrifugal Monoblock Pump set (Double Stage)

-

-

-

... More
3.7 KW (5.0 HP)

-

50344

50344

... More
5.5 KW (7.5 HP)

-

61220

61220

... More
7.5 KW (10.0 HP)

-

73509

73509

... More
9.3 KW (12.5 HP)

-

81408

81408

... More
11.0 KW (15.0 HP)

-

89948

89948

... More
15.0 KW (20.0 HP)

-

117644

117644

... More
Vacuum Pump set (Monoblock)

-

-

-

... More
Providing, installation, testing and commissioning of Mono block Vacuum pump set with base plate including C.C. foundation / cross channels / RSJ frame and foundation bolts etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge.

-

-

-

... More
0.75 KW (1 HP), single Ph

-

31145

31145

... More
2.2 KW (3 HP), three Ph

-

56725

56725

... More
Vacuum Pump set (Coupled)

-

-

-

... More
Providing, installation, testing and commissioning of Vacuum pump set with horizontal foot mounted TEFC squirrel cage motor working on three phase 50 Hz, 415 Volts +/- 10% with base plate including cost of flexible couplings, coupling guard etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge.

-

-

-

... More
3.7 KW (5.0 HP)

-

120824

120824

... More
7.5 KW (10.0 HP)

-

148983

148983

... More
Providing, installation, testing and commissioning of Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class "F" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
15 KW

-

243761

243761

... More
18.5 KW

-

300640

300640

... More
22 KW

-

357517

357517

... More
30 KW

-

487522

487522

... More
37 KW

-

598068

598068

... More
45 KW

-

633155

633155

... More
55 KW

-

813097

813097

... More
75 KW

-

902677

902677

... More
90 KW

-

1221495

1221495

... More
110 KW

-

1503260

1503260

... More
125 KW

-

1648764

1648764

... More
132 KW

-

1738837

1738837

... More
160 KW

-

2002177

2002177

... More
180 KW

-

2127112

2127112

... More
200 KW

-

2552534

2552534

... More
Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following posion : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)

-

-

-

... More
2.2 KW (3.0 HP)

-

35932

35932

... More
3.7 KW (5.0 HP)

-

39941

39941

... More
5.5 KW (7.5 HP)

-

53789

53789

... More
7.5 KW (10 HP)

-

60640

60640

... More
9.3 KW (12.5 HP)

-

76487

76487

... More
11.0 KW (15 HP)

-

85567

85567

... More
15.0 KW (20.0 HP)

-

101747

101747

... More
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
0.75 KW (1.0 HP)

-

40555

40555

... More
1.5 KW (2.0 HP)

-

46501

46501

... More
2.2 KW (3.0 HP)

-

80307

80307

... More
3.7 KW (5.0 HP )

-

107500

107500

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
Discharge 20 to 30 LPS and head 20 to 30 M

-

166357

166357

... More
Discharge 20 to 30 LPS and head 31 to 40 M

-

242227

242227

... More
Discharge 20 to 30 LPS and head 41 to 50 M

-

285634

285634

... More
Discharge 20 to 30 LPS and head 51 to 60 M

-

327309

327309

... More
Discharge 20 to 30 LPS and head 61 to 70 M

-

417667

417667

... More
Discharge 20 to 30 LPS and head 71 to 80 M

-

417667

417667

... More
Discharge 20 to 30 LPS and head 81 to 90 M

-

417667

417667

... More
Discharge 31 t0 40 LPS and head 20 to 30 M

-

242227

242227

... More
Discharge 31 t0 40 LPS and head 31 to 40 M

-

285634

285634

... More
Discharge 31 t0 40 LPS and head 41 to 50 M

-

327309

327309

... More
Discharge 31 t0 40 LPS and head 51 to 60 M

-

417667

417667

... More
Discharge 31 t0 40 LPS and head 61 to 70 M

-

492515

492515

... More
Discharge 31 to 40 LPS and head 71 to 80 M

-

492515

492515

... More
Discharge 31 to 40 LPS and head 81 to 90 M

-

574432

574432

... More
Discharge 41 t0 50 LPS and head 20 to 30 M

-

285634

285634

... More
Discharge 41 t0 50 LPS and head 31 to 40 M

-

417667

417667

... More
Discharge 41 t0 50 LPS and head 41 to 50 M

-

417667

417667

... More
Discharge 41 t0 50 LPS and head 51 to 60 M

-

492515

492515

... More
Discharge 41 t0 50 LPS and head 61 to 70 M

-

574432

574432

... More
Discharge 41 to 50 LPS and head 71 to 80 M

-

672571

672571

... More
Discharge 41 to 50 LPS and head 81 to 90 M

-

672571

672571

... More
Discharge 51 to 60 LPS and head 20 to 30 M

-

327309

327309

... More
Discharge 51 to 60 LPS and head 31 to 40 M

-

417667

417667

... More
Discharge 51 to 60 LPS and head 41 to 50 M

-

492515

492515

... More
Discharge 51 to 60 LPS and head 51 to 60 M

-

574432

574432

... More
Discharge 51 to 60 LPS and head 61 to 70 M

-

672571

672571

... More
Discharge 51 to 60 LPS and head 71 to 80 M

-

858245

858245

... More
Discharge 51 to 60 LPS and head 81 to 90 M

-

858245

858245

... More
Discharge 61 to 70 LPS and head 20 to 30 M

-

327309

327309

... More
Discharge 61 to 70 LPS and head 31 to 40 M

-

417667

417667

... More
Discharge 61 to 70 LPS and head 41 to 50 M

-

574432

574432

... More
Discharge 61 to 70 LPS and head 51 to 60 M

-

672571

672571

... More
Discharge 61 to 70 LPS and head 61 to 70 M

-

858245

858245

... More
Discharge 61 to 70 LPS and head 71 to 80 M

-

858245

858245

... More
Discharge 61 to 70 LPS and head 81 to 90 M

-

990485

990485

... More
Discharge 71 to 80 LPS and head 20 to 30 M

-

417667

417667

... More
Discharge 71 to 80 LPS and head 31 to 40 M

-

492515

492515

... More
Discharge 71 to 80 LPS and head 41 to 50 M

-

672571

672571

... More
Discharge 71 to 80 LPS and head 51 to 60 M

-

858245

858245

... More
Discharge 71 to 80 LPS and head 61 to 70 M

-

858245

858245

... More
Discharge 71 to 80 LPS and head 71 to 80 M

-

990485

990485

... More
Discharge 71 to 80 LPS and head 81 to 90 M

-

1159705

1159705

... More
Discharge 81 to 90 LPS and head 20 to 30 M

-

417667

417667

... More
Discharge 81 to 90 LPS and head 31 to 40 M

-

574432

574432

... More
Discharge 81 to 90 LPS and head 41 to 50 M

-

672571

672571

... More
Discharge 81 to 90 LPS and head 51 to 60 M

-

858245

858245

... More
Discharge 81 to 90 LPS and head 61 to 70 M

-

858245

858245

... More
Discharge 81 to 90 LPS and head 71 to 80 M

-

1159705

1159705

... More
Discharge 81 to 90 LPS and head 81 to 90 M

-

1159705

1159705

... More
Discharge 91 to 100 LPS and head 20 to 30 M

-

492515

492515

... More
Discharge 91 to 100 LPS and head 31 to 40 M

-

672571

672571

... More
Discharge 91 to 100 LPS and head 41 to 50 M

-

858245

858245

... More
Discharge 91 to 100 LPS and head 51 to 60 M

-

858245

858245

... More
Discharge 91 to 100 LPS and head 61 to 70 M

-

990485

990485

... More
Discharge 91 to 100 LPS and head 71 to 80 M

-

1159705

1159705

... More
Discharge 91 to 100 LPS and head 81 to 90 M

-

1282285

1282285

... More
Discharge 101 to 120 LPS and head 20 to 30 M

-

492515

492515

... More
Discharge 101 to 120 LPS and head 31 to 40 M

-

672571

672571

... More
Discharge 101 to 120 LPS and head 41 to 50 M

-

858245

858245

... More
Discharge 101 to 120 LPS and head 51 to 60 M

-

990485

990485

... More
Discharge 101 to 120 LPS and head 61 to 70 M

-

1159705

1159705

... More
Discharge 101to 120 LPS and head 71 to 80 M

-

1159705

1159705

... More
Discharge 101to 120 LPS and head 81 to 90 M

-

1556866

1556866

... More
Discharge 121 to 140 LPS and head 20 to 30 M

-

574432

574432

... More
Discharge 121 to 140 LPS and head 31 to 40 M

-

858245

858245

... More
Discharge 121 to 140 LPS and head 41 to 50 M

-

990485

990485

... More
Discharge 121 to 140 LPS and head 51 to 60 M

-

1159705

1159705

... More
Discharge 121 to 140 LPS and head 61 to 70 M

-

1159705

1159705

... More
Discharge 121 to 140 LPS and head 71 to 80 M

-

1338395

1338395

... More
Discharge 121 to 140 LPS and head 81 to 90 M

-

1556866

1556866

... More
Discharge 141 to 160 LPS and head 20 to 30 M

-

672571

672571

... More
Discharge 141 to 160 LPS and head 31 to 40 M

-

858245

858245

... More
Discharge 141 to 160 LPS and head 41 to 50 M

-

1159705

1159705

... More
Discharge 141 to 160 LPS and head 51 to 60 M

-

1282285

1282285

... More
Discharge 141 to 160 LPS and head 61 to 70 M

-

1556866

1556866

... More
Discharge 141 to 160 LPS and head 71 to 80 M

-

1556866

1556866

... More
Discharge 141 to 160 LPS and head 81 to 90 M

-

1855336

1855336

... More
Discharge 161 to 180 LPS and head 20 to 30 M

-

858245

858245

... More
Discharge 161 to 180 LPS and head 31 to 40 M

-

990485

990485

... More
Discharge 161 to 180 LPS and head 41 to 50 M

-

1159705

1159705

... More
Discharge 161 to 180 LPS and head 51 to 60 M

-

1338395

1338395

... More
Discharge 161 to 180 LPS and head 61 to 70 M

-

1556866

1556866

... More
Discharge 161 to 180 LPS and head 71 to 80 M

-

1707880

1707880

... More
Discharge 161 to 180 LPS and head 81 to 90 M

-

1855336

1855336

... More
Discharge 181 to 200 LPS and head 20 to 30 M

-

858245

858245

... More
Discharge 181 to 200 LPS and head 31 to 40 M

-

1159705

1159705

... More
Discharge 181 to 200 LPS and head 41 to 50 M

-

1282285

1282285

... More
Discharge 181 to 200 LPS and head 51 to 60 M

-

1556866

1556866

... More
Discharge 181 to 200 LPS and head 61 to 70 M

-

1707880

1707880

... More
Discharge 181 to 200 LPS and head 71 to 80 M

-

1999666

1999666

... More
Discharge 181 to 200 LPS and head 81 to 90 M

-

2211026

2211026

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
Discharge 201 to 220 LPS and head 20 to 30 M

-

858245

858245

... More
Discharge 201 to 220 LPS and head 31 to 40 M

-

1159705

1159705

... More
Discharge 201 to 220 LPS and head 41 to 50 M

-

1556866

1556866

... More
Discharge 201 to 220 LPS and head 51 to 60 M

-

1707880

1707880

... More
Discharge 201 to 220 LPS and head 61 to 70 M

-

1855336

1855336

... More
Discharge 221 to 240 LPS and head 20 to 30 M

-

990485

990485

... More
Discharge 221 to 240 LPS and head 31 to 40 M

-

1282285

1282285

... More
Discharge 221 to 240 LPS and head 41 to 50 M

-

1556866

1556866

... More
Discharge 221 to 240 LPS and head 51 to 60 M

-

1855336

1855336

... More
Discharge 221 to 240 LPS and head 61 to 70 M

-

1999666

1999666

... More
Discharge 241 to 260 LPS and head 20 to 30 M

-

990485

990485

... More
Discharge 241 to 260 LPS and head 31 to 40 M

-

1338395

1338395

... More
Discharge 241 to 260 LPS and head 41 to 50 M

-

1556866

1556866

... More
Discharge 241 to 260 LPS and head 51 to 60 M

-

1855336

1855336

... More
Discharge 241 to 260 LPS and head 61 to 70 M

-

2211026

2211026

... More
Discharge 261 to 280 LPS and head 20 to 30 M

-

1159705

1159705

... More
Discharge 261 to 280 LPS and head 31 to 40 M

-

1556866

1556866

... More
Discharge 261 to 280 LPS and head 41 to 50 M

-

1707880

1707880

... More
Discharge 261 to 280 LPS and head 51 to 60 M

-

1999666

1999666

... More
Discharge 261 to 280 LPS and head 61 to 70 M

-

2383025

2383025

... More
Discharge 281 to 300 LPS and head 20 to 30 M

-

1159705

1159705

... More
Discharge 281 to 300 LPS and head 31 to 40 M

-

1556866

1556866

... More
Discharge 281 to 300 LPS and head 41 to 50 M

-

1855336

1855336

... More
Discharge 281 to 300 LPS and head 51 to 60 M

-

1999666

1999666

... More
Discharge 281 to 300 LPS and head 61 to 70 M

-

2383025

2383025

... More
Discharge 301 to 325 LPS and head 20 to 30 M

-

1282285

1282285

... More
Discharge 301 to 325 LPS and head 31 to 40 M

-

1556866

1556866

... More
Discharge 301 to 325 LPS and head 41 to 50 M

-

1999666

1999666

... More
Discharge 301 to 325 LPS and head 51 to 60 M

-

2211026

2211026

... More
Discharge 301 to 325 LPS and head 61 to 70 M

-

2651461

2651461

... More
Discharge 326 to 350 LPS and head 20 to 30 M

-

1282285

1282285

... More
Discharge 326 to 350 LPS and head 31 to 40 M

-

1707880

1707880

... More
Discharge 326 to 350 LPS and head 41 to 50 M

-

1999666

1999666

... More
Discharge 326 to 350 LPS and head 51 to 60 M

-

2383025

2383025

... More
Discharge 326 to 350 LPS and head 61 to 70 M

-

2651461

2651461

... More
Discharge 351 to 400 LPS and head 20 to 30 M

-

1556866

1556866

... More
Discharge 351 to 400 LPS and head 31 to 40 M

-

1855336

1855336

... More
Discharge 351 to 400 LPS and head 41 to 50 M

-

2211026

2211026

... More
Discharge 351 to 400 LPS and head 51 to 60 M

-

2651461

2651461

... More
Discharge 351 to 400 LPS and head 61 to 70 M

-

2912679

2912679

... More
Valves and Appurtenances

-

-

-

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
80 mm HW

-

6301

6301

... More
100 mm HW

-

8649

8649

... More
125 mm HW

-

11173

11173

... More
150 mm HW

-

13595

13595

... More
200 mm HW

-

22603

22603

... More
250 mm HW

-

35722

35722

... More
300 mm HW

-

45382

45382

... More
Motorized Sluice Valves with Electric Actuator with integral starter of Class PN 1.0

-

-

-

... More
80 mm dia

-

118496

118496

... More
100 mm dia

-

122294

122294

... More
125 mm dia

-

126666

126666

... More
150 mm dia

-

133417

133417

... More
200 mm dia

-

151343

151343

... More
250 mm dia

-

171551

171551

... More
300 mm dia

-

182779

182779

... More
Providing, lowering, laying, aligning, fixing in position CI D/F short body pattern type butterfly valves having body, disc and end cover in graded cast iron generally conforming to (IS13095/1991amended up to date), synthetic rubber faced ring secured on disc by retaining ring with SS steel screw stub shaft of SS riding in Teflon bearing including C.C. foundation/ structural steel support, material, labour, testing along with pipe line and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work

-

-

-

... More
Manually Operated Butterfly Valve PN-1.0

-

-

-

... More
100 mm dia ( With lever operated)

-

12762

12762

... More
125 mm dia ( With lever operated)

-

17582

17582

... More
150 mm dia ( With lever operated)

-

21877

21877

... More
200 mm dia (With Gear Operated)

-

32923

32923

... More
250 mm dia (With Gear Operated)

-

41797

41797

... More
300 mm dia (With Gear Operated)

-

52123

52123

... More
350 mm dia (With Gear Operated)

-

65006

65006

... More
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in- charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

... More
80 mm dia

-

6219

6219

... More
100 mm dia

-

7973

7973

... More
125 mm dia

-

10452

10452

... More
150 mm dia

-

13107

13107

... More
200 mm dia

-

22519

22519

... More
250 mm dia

-

36559

36559

... More
300 mm dia

-

50411

50411

... More
350 mm dia

-

88822

88822

... More
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

... More
80 mm dia

-

6055

6055

... More
100 mm dia

-

7694

7694

... More
125 mm dia

-

9640

9640

... More
150 mm dia

-

12719

12719

... More
200 mm dia

-

21892

21892

... More
250 mm dia

-

34618

34618

... More
300 mm dia

-

46370

46370

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or Screwed type shall have external pipe threads conforming to IS 554 Fasteners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

... More
15 mm S-1 Type

-

2423

2423

... More
25 mm S-1 Type

-

3145

3145

... More
40 mm S-1 Type

-

3912

3912

... More
50 mm S-2 Type

-

4590

4590

... More
Class PN 1.6

-

-

-

... More
15 mm S-1 Type

-

2587

2587

... More
25 mm S-1 Type

-

3296

3296

... More
40 mm S-1 Type

-

4046

4046

... More
50 mm S-2 Type

-

4811

4811

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

... More
40 mm

-

11616

11616

... More
50 mm

-

13234

13234

... More
80 mm

-

17112

17112

... More
100 mm

-

23250

23250

... More
150 mm

-

48594

48594

... More
200 mm

-

74101

74101

... More
Class PN 1.6

-

-

-

... More
40 mm

-

12431

12431

... More
50 mm

-

14126

14126

... More
80 mm

-

17858

17858

... More
100 mm

-

24184

24184

... More
150 mm

-

51118

51118

... More
200 mm

-

77713

77713

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. Epoxy paint (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

... More
40 mm

-

12811

12811

... More
50 mm

-

14038

14038

... More
80 mm

-

17304

17304

... More
100 mm

-

23227

23227

... More
150 mm

-

39551

39551

... More
200 mm

-

57592

57592

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in- charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
80 mm dia

-

9137

9137

... More
100 mm dia

-

11554

11554

... More
125 mm dia

-

17087

17087

... More
150 mm dia

-

19109

19109

... More
200 mm dia

-

29396

29396

... More
250 mm dia

-

48781

48781

... More
300 mm dia

-

62128

62128

... More
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.0

-

-

-

... More
80 mm dia

-

120451

120451

... More
100 mm dia

-

123908

123908

... More
125 mm dia

-

131735

131735

... More
150 mm dia

-

136800

136800

... More
200 mm dia

-

155060

155060

... More
250 mm dia

-

177836

177836

... More
300 mm dia

-

194973

194973

... More
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
80 mm dia

-

121297

121297

... More
100 mm dia

-

124743

124743

... More
125 mm dia

-

132962

132962

... More
150 mm dia

-

139701

139701

... More
200 mm dia

-

155351

155351

... More
250 mm dia

-

177684

177684

... More
300 mm dia

-

193924

193924

... More
350 mm dia

-

256125

256125

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in- charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6, Manually Operated with Gear

-

-

-

... More
100 mm dia

-

50005

50005

... More
150 mm dia

-

57538

57538

... More
200 mm dia

-

59837

59837

... More
250 mm dia

-

66241

66241

... More
300 mm dia

-

74691

74691

... More
350 mm dia

-

93544

93544

... More
Providing, lowering, aligning, fixing in position in pipe line, DI resilient seated (soft seated) Concentric Wafer type, Butterfly valves of approved make of following Pressure rating & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc - DI (same as body material) / CS, Face to face dimensions as per DIN 3202 F4/ IS 13095 , Flanges Drilled as per IS:1538 ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside . Liner & Disc seal - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410/420 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal , Nut-Bolt confirming to IS:1363 and IS: 1367/ Galvanised steel, Insertion rubber of black EPDM 6mm thick ,Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6, Wafer Type

-

-

-

... More
80 mm (Lever Operated)

-

10585

10585

... More
100 mm (Lever Operated)

-

12783

12783

... More
125 mm (Lever Operated

-

21548

21548

... More
150 mm (Lever Operated)

-

23397

23397

... More
200 mm (with Gear)

-

35284

35284

... More
250 mm (with Gear)

-

45556

45556

... More
300 mm (with Gear)

-

50571

50571

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal Nut- Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
80 mm dia

-

9458

9458

... More
100 mm dia

-

12598

12598

... More
125 mm dia

-

17774

17774

... More
150 mm dia

-

21821

21821

... More
200 mm dia

-

37011

37011

... More
250 mm dia

-

55783

55783

... More
300 mm dia

-

76588

76588

... More
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
80 mm dia

-

11584

11584

... More
100 mm dia

-

13362

13362

... More
125 mm dia

-

14224

14224

... More
150 mm dia

-

20940

20940

... More
200 mm dia

-

36510

36510

... More
250 mm dia

-

55072

55072

... More
300 mm dia

-

77472

77472

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
40 mm dia

-

13021

13021

... More
50 mm dia

-

13499

13499

... More
80 mm dia

-

17236

17236

... More
100 mm dia

-

23449

23449

... More
150 mm dia

-

40162

40162

... More
200 mm dia

-

55019

55019

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR Drilled as per IS:1538. Electrostatic Epoxy Powder(EP- P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512. ), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
50 mm dia

-

18064

18064

... More
80 mm dia

-

23209

23209

... More
100 mm dia

-

31051

31051

... More
150 mm dia

-

49563

49563

... More
200 mm dia

-

62215

62215

... More
Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Plunger Type Flow Control Valve

-

-

-

... More
80 mm dia

-

338036

338036

... More
100mm dia

-

368438

368438

... More
125 mm dia

-

410651

410651

... More
150mm dia

-

450548

450548

... More
200mm dia

-

552018

552018

... More
250mm dia

-

645671

645671

... More
300mm dia

-

788276

788276

... More
350mm dia

-

829368

829368

... More
Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure Reducing / Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body & Bonnet - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc - Flexible, non-wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM (FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M / AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316/410, raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316 ,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze ,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI-316 ,Throttling plug - Stainless Steel, AISI-304, Nut- Bolts - SS Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. insertion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Pilot operated SCADA Compatible Diaphragm Type Pressure Reducing Valves (Class PN 1.6)

-

-

-

... More
80 mm dia

-

114654

114654

... More
100 mm dia

-

124190

124190

... More
125 mm dia

-

143136

143136

... More
150 mm dia

-

169176

169176

... More
200 mm dia

-

209789

209789

... More
250 mm dia

-

285584

285584

... More
300 mm dia

-

376769

376769

... More
Diaphragm Type Flow Control Valve With Electrical Actuator suitable for SCADA (PN 1.6 )

-

-

-

... More
80 mm dia

-

108336

108336

... More
100 mm dia

-

119999

119999

... More
125 mm dia

-

140144

140144

... More
150 mm dia

-

155111

155111

... More
200 mm dia

-

181481

181481

... More
250 mm dia

-

260901

260901

... More
300 mm dia

-

362386

362386

... More
DOL / Star delta starter type LT panels

-

-

-

... More
SITC DOL Starter type LT Panel of following rating, all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. complete as per Technical Specifications and as per direction of Engineer-In-Charge.

-

-

-

... More
DOL STARTER 2.2 KW (3 HP)- : For 2 motors (1 W+ 1S) I/C - MCB 25A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 16A ,TP, 10 KA, C Curve (2), Power Cont 9A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (4-6A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2)

-

49356

49356

... More
DOL STARTER 3.7KW (5 HP ) - : For 2 motors (1 W+ 1S) I/C - MCB 32A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 25A ,TP, 10 KA, C Curve (2), Power Cont 12A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2)

-

50413

50413

... More
DOL STARTER 5.5 KW (7.5HP) - : For 2 motors (1 W+ 1S) I/C - MCB 40A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 25A ,TP, 10 KA, C Curve (2), Power Cont 12A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2)

-

51448

51448

... More
SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge.

-

-

-

... More
STAR DELTA STARTER 7.5 KW (10.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)

-

65077

65077

... More
STAR DELTA STARTER 9.3 KW (12.5 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)

-

66938

66938

... More
STAR DELTA STARTER 11.0 KW (15.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

-

70561

70561

... More
STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

-

99226

99226

... More
STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2)

-

108534

108534

... More
STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2)

-

122057

122057

... More
submersible motor pump set

-

-

-

... More
Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
Up to 2.0 KW

-

16762

16762

... More
Above 2.0 KW

-

13050

13050

... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.

-

9083

9083

... More
Up to 5.5 KW (7.5 HP) & head above 120 mtr.

-

9628

9628

... More
7.5 KW (10 HP) & head up to 120 mtr.

-

6844

6844

... More
7.5 KW (10 HP) & head above 120 mtr.

-

8320

8320

... More
9.3 KW (12.5 HP) & head up to 120 mtr.

-

5800

5800

... More
9.3 KW (12.5 HP) & head above 120 mtr.

-

7552

7552

... More
11 KW (15 HP) & head up to 120 mtr.

-

5614

5614

... More
11 KW (15 HP) & head above 120 mtr.

-

6577

6577

... More
13 KW (17.5 HP) & head up to 120 mtr.

-

5603

5603

... More
13 KW (17.5 HP) & head above 120 mtr.

-

6400

6400

... More
15 KW (20 HP) and above, head up to 120 mtr.

-

5580

5580

... More
15 KW (20 HP) and above, head above 120 mtr.

-

6320

6320

... More
Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.

-

10009

10009

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

-

13081

13081

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Above 5 HP and up to 10 HP

-

24273

24273

... More
Above 10 HP and up to 15 HP

-

27829

27829

... More
Above 15 HP and up to 20 HP

-

32117

32117

... More
Above 20 HP and up to 30 HP

-

39375

39375

... More
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.

-

-

-

... More
3 core 4.0 Sq.mm

-

189

189

... More
3 core 6.0 Sq.mm

-

283

283

... More
3 core 10.0 Sq.mm

-

484

484

... More
3 core 16.0 Sq.mm

-

722

722

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

-

196

196

... More
16.0 Sq.mm, 4 core

-

234

234

... More
25.0 Sq.mm, 3.5 core

-

324

324

... More
35.0 Sq.mm, 3.5 core

-

379

379



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.