Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Eprocure
Opening Date26 Sep 2022
Closing Date13 Oct 2022
Tender Amount₹ 6,74,29,000 
Notes
Download

Costs

  • EMD

    ₹ 13,48,580
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 1,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation over area (exceeding 30 cm in depth 1.5 m in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50 m and lift upto 1.5 m. Disposed earth to be leveled and neatly dressed including stacking of useful material if available.

-

-

-

... More
Ordinary rock

-

-

-

... More
From 3m to6m BGL

488.79

-

611

... More
Hard rock (requiring blasting) useful material 30 %

-

-

-

... More
From 6m to7m BGL

162.9

-

883

... More
From 7m to20m BGL

1470.87

-

883

... More
Add extra over item No 2.1 and 2.2 for every additional; lift of 1.5 m or part thereof.

-

-

-

... More
In All Kind of soil

-

-

-

... More
From 0m to1.5m BGL

-

-

-

... More
From 1.5m to3m BGL

244.35

-

43

... More
In ordinary rock and hard rock

-

-

-

... More
From 3m to4.5m BGL

244.35

-

122

... More
From 4.5m to6m BGL

244.35

-

183

... More
From 6m to7.5m BGL

244.35

-

244

... More
From 7.5m to9m BGL

244.35

-

305

... More
From 9m to10.5m BGL

169.74

-

366

... More
From 10.5m to12m BGL

169.74

-

427

... More
From 12m to13.5m BGL

169.74

-

488

... More
From 13.5m to15m BGL

169.74

-

549

... More
From 15m to16.5m BGL

169.74

-

610

... More
From 16.5m to18m BGL

169.74

-

671

... More
From 18m to19.5m BGL

169.74

-

732

... More
From 19.5m to20m BGL

56.61

-

793

... More
Add extra over item no 2.1 and 2.2 for excavation in saturated soil where pumping or bailing out of water is required including shorting strutting where required and dewatering.(20% of Respective applicable rates)

-

-

-

... More
From 9m to10.5m BWL

169.74

-

249.8

... More
From 10.5m to12m BWL

169.74

-

262

... More
From 12m to13.5m BWL

169.74

-

274.2

... More
From 13.5m to15m BWL

169.74

-

286.4

... More
From 15m to16.5m BWL

169.74

-

298.6

... More
From 16.5m to18m BWL

169.74

-

310.8

... More
From 18m to19.5m BWL

169.74

-

323

... More
From 19.5m to20m BWL

56.61

-

335.2

... More
Centering & shuttering with ply wood or steel sheets including strutting , propping, barcing both ways with wooden members and removal of form work up to floor three level for:Walls (any thickness) including attached pilasters, buttresses, plinth and string course.Add extra for shuttering in circular work in plan up to dia 10 m over item no 2.6.1

1751.49

-

258.5

... More
Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three level

-

-

-

... More
Thermo mechanically treated bars (conforming to relevant IS:1786.)

8049.49

-

85

... More
Providing and layiny in position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement for :

-

-

-

... More
Walls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc.

-

-

-

... More
M20 grade nominal mix (with graded stone aggregate 20mm nominal size)

136.8

-

7764

... More
Structural steel work in single section fixed with connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height

-

-

-

... More
In flates, tees, angles & Channals

3600

-

86

... More
In R.S. Joists

1800

-

86

... More
P&F welded mesh / expended metal mesh in frame work flat iron weeding 20x3 mm incl top cross laps inside & out sode welding etc weded mesh 25*25*16 guage

90

-

794

... More
Random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in:

-

-

-

... More
Cement Mortar 1:4 ( 1 cement : 4 Sand )

45

-

2740

... More
Random Rubble stone masonary for superstructure above plinth level one storey height above 30 cm. thick walls in :

-

-

-

... More
Cement mortar 1:4 ( 1 Cement : 4 Sand )

135

-

3060

... More
Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish:

-

-

-

... More
20 mm thick

90

-

210

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding

-

-

-

... More
New Work ( Three or more coats)

135

-

70

... More
Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade :

-

-

-

... More
New steel work ( two or more coats)

72

-

50

... More
Contruction of tubewell 200mm dia 150 mtr deep

-

-

-

... More
Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.

-

-

-

... More
Nominal bore 200 mm dia.

800

-

961

... More
Add 15% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.

-

-

-

... More
Nominal bore 200 mm dia.

400

-

1105.15

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)

132

-

2630

... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.

8

-

600

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.

-

-

-

... More
200 mm dia

8

-

850

... More
Providing & Installation pumpsets for pumping water for RVS DHORAN-MORCHA

-

-

-

... More
Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and 2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
2.2 KW (3.0 HP)

3

-

30976

... More
3.7 KW (5.0 HP)

6

-

34432

... More
Supplying & installation 100 diameter sealed diaphragm bourden type pressure gauge of range 0 to 10 kg including all jointing material as per specification of safety cover.

5

-

1100

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

5

-

11201

... More
Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50mm dia

115

-

597

... More
Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8 130: 1980 includ ing making connection etc.

-

-

-

... More
3 core 4.0 mm2

330

-

163

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

80

-

169

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

5

-

11343.5

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

5

-

2160

... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
Up to 5.5 KW (3.73KW/5.00 HP) & head up to 120 mtr.

11.19

-

7830

... More
Supplying & installation 100 diameter sealed diaphragm bourden type pressure gauge of range 0 to 10 kg including all jointing material as per specification of safety cover.

3

-

1100

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

3

-

11201

... More
Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50mm dia

300

-

597

... More
Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8 130: 1980 includ ing making connection etc.

-

-

-

... More
3 core 4.0 mm2

374

-

163

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

60

-

169

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

3

-

11343.5

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Above 15 HP kelwara

1

-

27687.2

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

3

-

2160

... More
Providing & Installation pumpsets for pumping water from openwell

-

-

-

... More
Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and 2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
3.7 KW (5.0 HP) prop OW1&2 JOJ

2

-

34432

... More
5.5 KW (7.5 HP) prop OW 1&2 Kharnota

2

-

46370

... More
Supplying & installation 100 diameter sealed diaphragm bourden type pressure gauge of range 0 to 10 kg including all jointing material as per specification of safety cover.

4

-

1100

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

4

-

11201

... More
Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50mm dia

100

-

597

... More
Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8 130: 1980 includ ing making connection etc.

-

-

-

... More
3 core 4.0 mm2

240

-

163

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

105

-

169

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

2

-

11344

... More
Above 5 HP and up to 10 HP

2

-

20924.9

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

4

-

2160

... More
Providing & Installation pumpsets for pumping water from Openwell for RVS thoriya-bardaya-chatraji ka guda

-

-

-

... More
Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and 2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
3.7 KW (5.0 HP)

1

-

34432

... More
5.5 KW (7.5 HP)

1

-

46370

... More
Supplying & installation 100 diameter sealed diaphragm bourden type pressure gauge of range 0 to 10 kg including all jointing material as per specification of safety cover.

2

-

1100

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

2

-

11201

... More
Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50mm dia

50

-

597

... More
Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8 130: 1980 includ ing making connection etc.

-

-

-

... More
3 core 4.0 mm2

60

-

163

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

60

-

169

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

1

-

11343.5

... More
Above 5 HP and up to 10 HP

1

-

20924.9

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

2

-

2160

... More
Providing & Installation pumpsets for pumping water from tubewell

-

-

-

... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
Up to 5.5 KW (7.5 HP) & head up to 120 mtr prop TW Amdai

3.7

-

7830

... More
Up to 5.5 KW (7.5 HP) & head above 120 mtr( Ext TW Kharnota)

5.5

-

8300

... More
Supplying & installation 100 diameter sealed diaphragm bourden type pressure gauge of range 0 to 10 kg including all jointing material as per specification of safety cover.

2

-

1100

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

2

-

11201

... More
Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50mm dia

190

-

597

... More
Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8 130: 1980 includ ing making connection etc.

-

-

-

... More
3 core 4.0 mm2

440

-

163

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

40

-

169

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

1

-

11343.5

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Above 5 HP and up to 10 HP

1

-

20924.9

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

2

-

2160

... More
Providing & Installation pumpsets for pumping water from Tubewell for RVS Thoriya-bardaya-chatraji ka guda

-

-

-

... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.( 3Nos)

13.43

-

7830

... More
Up to 5.5 KW (7.5 HP) & head above 120 mtr(2 Nos)

9.38

-

8300

... More
Supplying & installation 100 diameter sealed diaphragm bourden type pressure gauge of range 0 to 10 kg including all jointing material as per specification of safety cover.

5

-

1100

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

5

-

11201

... More
Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50mm dia

600

-

597

... More
Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8 130: 1980 includ ing making connection etc.

-

-

-

... More
3 core 4.0 mm2

750

-

163

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

100

-

169

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Up to 5.00 HP

2

-

11343.5

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Above 5 HP and up to 10 HP

3

-

20924.9

... More
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes

-

-

-

... More
65 mm dia

5

-

2160

... More
Providing, laying and jointing rising mains.

-

-

-

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing in trenches Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS: 8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 incl. all taxes (Central and Local) transportation and frieght charges, inspection charges, loading/unloadingcharges, stacking of pipes including cost of labour and material, specials(Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer in Charge.( excluding earth work) with excise Duty Exemption. Note:- Providing and fixing of all requisite specials as per drawing, design and layout areinclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
Dia (mm) Type Class

-

-

-

... More
100 DI K-7

9490

-

1262

... More
Providing,supplying,lowering & Laying in trenches,standerd lengths HDPE,PE-80 ISI Marked pipes of following grade and nominal diameter as per conferming IS-4984:1995 With necessory jointing material like mechanical connectors,i.e. thead/insert joint/quick release coupler joint/compression fitting joint or flanged joint and specials jointing pipe by butt fusion welding method,including all taxes (Central and local), transpotation and freight charges,inspection charges,loading /unloading charges ,stacking the same in closed shade duly protectingfrom sunrays and rains ,including cost of labour and material ,specials (Tee band etc) satisfactory hydraulic testing etc.Complete as per technical specifications and direction of engineer-in charge,(excluding earth work) . Note-Providing and fixing of all requsite specials as per drawing ,design and layout are inclusive in RM measurement of the item and shall not be paid seperately. supply upto 110mm dia coil & above 110mm dia straight length in 6M.

-

-

-

... More
90 mm dia PE-80 PN-10

500

-

387

... More
110 mm dia PE-80 PN-10

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths Dl standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 5382 1985 such as tees, bends, tapers, caps etc. within trenches in DI pipe line complere including all marerial, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work)

-

-

-

... More
AJS Tee , Bend, Reducer (All End Socketed)

-

-

-

... More
Upto 300 mm Diameter

450

-

139

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated DI D/F Resilient (Soft) seated Gate Valve EPDM Coated DI wedge 100% vaccum light, flange Dimention IS: 14846, of approved make PN 1.6 class and CI Tail Piece- 2 Nos. (IS: 5531- 1988- amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (Nominal Dia. in mm)

-

-

-

... More
Soft seated sluice valves

-

-

-

... More
Dia (mm) PN rating

-

-

-

... More
100 1.6

24

-

9960

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
100 mm dia.

24

-

3160

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS:6418 or screwed type shall have external pipe threads conforming to IS:554, Fasteners - CS. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
25 mm S-1 Type

19

-

2711

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, DI resilient seated Non Return valves (NRV) of approved make PN 1.6 class and CI Tail Piece- 2 Nos. (IS: 5531 amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (Nominal Dia. in mm)

-

-

-

... More
Dia (mm) PN rating

-

-

-

... More
100 1.6

20

-

10860

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.including all saftey measures.

-

-

-

... More
All kind of soil

1366.2

-

172

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.including all saftey measures.

-

-

-

... More
ordinary rock

3119.4

-

322

... More
hard rock required blasting

485.7

-

475

... More
hard rock blasting prohibited

872.7

-

674

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

20

-

653

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

20

-

4033

... More
Cement concrete Saddle block. 25 nos

-

-

-

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.

-

-

-

... More
All kind of soil.

7.59

-

172

... More
Ordinary rock

5.06

-

322

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc.

36

-

258.5

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

5.4

-

4033

... More
Construction of saddle block size 0.60*0.60*0.60

45

-

1370

... More
Provision for construction of RCC Ground level service reservior.

-

-

-

... More
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).

-

-

-

... More
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm

-

-

-

... More
For capacity 50 KL.

-

-

-

... More
1. Boliyo ka guda (30KL )

30000

-

9.78

... More
2. Dhoran (50KL)

50000

-

9.78

... More
3. Menadar (20KL)

20000

-

9.78

... More
4. Rawli ki bhagal (15KL)

15000

-

9.78

... More
5. Tankdi (30KL)

30000

-

9.78

... More
6. Morcha (50KL)

50000

-

9.78

... More
7. Upla bhilwada (15KL)

15000

-

9.78

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

35

-

1016

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6

-

-

-

... More
100 mm

7

-

9960

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.

50

-

87

... More
Provision for construction of RCC GLSR 50KL ( 3 Nos)

-

-

-

... More
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).

-

-

-

... More
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm

-

-

-

... More
For capacity 50 KL.

150000

-

9.78

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

36

-

1016

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6

-

-

-

... More
100 mm

6

-

9960

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.

150

-

87

... More
Provision for construction of RCC GLSR 30KL

-

-

-

... More
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).

-

-

-

... More
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm

-

-

-

... More
For capacity 50 KL.

30000

-

9.78

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

12

-

1016

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6

-

-

-

... More
100 mm

2

-

9960

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.

50

-

87

... More
Provision for construction of RCC GLSR .15KL

-

-

-

... More
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).

-

-

-

... More
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm

-

-

-

... More
For capacity 50 KL.

15000

-

9.78

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

12

-

1016

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6

-

-

-

... More
100 mm

2

-

9960

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.

50

-

87

... More
Provision for construction of RCC Over Head Service Resrvoir .

-

-

-

... More
Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.

-

-

-

... More
j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M

-

-

-

... More
75 KL capacity at JOJ

75000

-

27.43

... More
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).

-

-

-

... More
k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M

-

-

-

... More
150KL capacity at Kharnota

150000

-

19.16

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
100 mm HW

5

-

7456

... More
200 mm HW

1

-

19485

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

126

-

1947

... More
200 mm

18

-

3664

... More
Construction of OHSR having capacity 100 KL.

-

-

-

... More
Construction of RCC flat slab Over Head Service Reservoir of following capacity and staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges including providing and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS screen, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height of ground level to top level, chambers for all valves, providing and applying three coats of cement paint to the external surfaces of container, column, bracing, carbonation paint on external surface of top dome, food grade epoxy paint on internal surface and giving satisfactory hydraulic test and water tightness test as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes conducting SBC test, design and proof check of reservoirs (if required), painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr(start of RCC reservoir) and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work .

-

-

-

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M

-

-

-

... More
100 KL capacity

100000

-

25.18

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

80

-

1947

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
100 mm

5

-

9960

... More
Providing, laying and jointing Distribution Pipe Line.

-

-

-

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing in trenches Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS: 8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 incl. all taxes (Central and Local) transportation and frieght charges, inspection charges, loading/unloadingcharges, stacking of pipes including cost of labour and material, specials(Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer in Charge.( excluding earth work) with excise Duty Exemption. Note:- Providing and fixing of all requisite specials as per drawing, design and layout areinclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
Dia (mm) Type Class

-

-

-

... More
80 DI K-7

-

-

-

... More
100 DI K-7

6537

-

1262

... More
Providing,supplying,lowering & Laying in trenches,standerd lengths HDPE,PE-80 ISI Marked pipes of following grade and nominal diameter as per conferming IS-4984:1995 With necessory jointing material like mechanical connectors,i.e. thead/insert joint/quick release coupler joint/compression fitting joint or flanged joint and specials jointing pipe by butt fusion welding method,including all taxes (Central and local), transpotation and freight charges,inspection charges,loading /unloading charges ,stacking the same in closed shade duly protectingfrom sunrays and rains ,including cost of labour and material ,specials (Tee band etc) satisfactory hydraulic testing etc.Complete as per technical specifications and direction of engineer-in charge,(excluding earth work) . Note-Providing and fixing of all requsite specials as per drawing ,design and layout are inclusive in RM measurement of the item and shall not be paid seperately. supply upto 110mm dia coil & above 110mm dia straight length in 6M.

-

-

-

... More
75 mm dia PE-80 PN-6

8045

-

187

... More
90 mm dia PE-80 PN-6

5734

-

264

... More
110 mm dia PE-80 PN-6

4248

-

399

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

-

-

-

... More
MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet)

750

-

122

... More
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths Dl standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 5382 1985 such as tees, bends, tapers, caps etc. within trenches in DI pipe line complere including all marerial, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work)

-

-

-

... More
AJS Tee , Bend, Reducer (All End Socketed)

-

-

-

... More
Upto 300 mm Diameter

400

-

139

... More
Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenence as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.

-

-

-

... More
Plain ended CI specials including tail piece, spigot end and socket end.

-

-

-

... More
Up to 300 mm dia

555

-

100

... More
Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)

-

-

-

... More
    60 mm thick.

420

-

237

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated DI D/F Resilient (Soft) seated Gate Valve EPDM Coated DI wedge 100% vaccum light, flange Dimention IS: 14846, of approved make PN 1.6 class and CI Tail Piece- 2 Nos. (IS: 5531- 1988- amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (Nominal Dia. in mm)

-

-

-

... More
Soft seated sluice valves

-

-

-

... More
Dia (mm) PN rating

-

-

-

... More
100 1.6

24

-

9960

... More
80 1.6

28

-

7877

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0

-

-

-

... More
80 mm dia

24

-

2715

... More
100 mm dia.

24

-

3160

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.including all saftey measures.

-

-

-

... More
All kind of soil

3223.8

-

172

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.including all saftey measures.

-

-

-

... More
ordinary rock

6534.5

-

322

... More
hard rock required blasting

1228.2

-

475

... More
hard rock blasting prohibited

2072.7

-

674

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

200

-

653

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

200

-

4033

... More
Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer.

-

-

-

... More
60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve

9

-

7660

... More
Construction of saddle block size 0.60*0.60*0.60

50

-

1370

... More
Deepning of open well 4.0 m dia upla bhilwara and menadar

-

-

-

... More
Earth work in excavation over area (exceeding 30 cm in depth 1.5 m in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50 m and lift upto 1.5 m. Disposed earth to be leveled and neatly dressed. All kinds of soil.

-

-

-

... More
Hard rock (requiring blasting) useful material 30 %

-

-

-

... More
From 7.5m to14m BGL

111.24

-

883

... More
Add extra over item No 2.1 and 2.2 for every additional; lift of 1.5 m or part thereof.

-

-

-

... More
In ordinary rock and hard rock

-

-

-

... More
From 7.5m to9m BGL

25.66

-

61

... More
From 9m to10.5m BGL

25.66

-

122

... More
From 10.5m to12m BGL

25.66

-

183

... More
From 12m to13.5m BGL

25.66

-

244

... More
From 13.5m to14m BGL

8.56

-

305

... More
From 14.0m to15.0m BWL

17.12

-

366

... More
Add extra over item no 2.1 and 2.2 for excavation in saturated soil where pumping or bailing out of water is required including shorting strutting where required and dewatering.(20% of Respective applicable rates)

-

-

-

... More
From 7.5m to9.0m BWL

25.66

-

176.6

... More
From 6m to7.5m BWL

25.66

-

176.6

... More
From 7.5m to9.0m BWL

25.66

-

188.8

... More
From 9m to10.5m BWL

25.66

-

201

... More
From 10.5m to12m BWL

25.66

-

213.2

... More
From 12m to13.5m BWL

25.66

-

225.4

... More
From 13.5m to15m BWL

25.66

-

245.73

... More
Centering & shuttering with ply wood or steel sheets including strutting , propping, barcing both ways with wooden members and removal of form work up to floor three level for:Walls (any thickness) including attached pilasters, buttresses, plinth and string course.Add extra for shuttering in circular work in plan up to dia 10 m over item no 2.6.1

60.34

-

258.5

... More
Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three level

-

-

-

... More
Thermo mechanically treated bars (conforming to relevant IS:1786.)

624.76

-

85

... More
Providing and layiny in position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement for :

-

-

-

... More
Walls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc.

-

-

-

... More
M20 grade nominal mix (with graded stone aggregate 20mm nominal size)

4.52

-

7764

... More
Structural steel work in single section fixed with connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height

-

-

-

... More
In flates, tees, angles & Channals

400

-

86

... More
In R.S. Joists

300

-

86

... More
P&F welded mesh / expended metal mesh in frame work flat iron weeding 20x3 mm incl top cross laps inside & out sode welding etc weded mesh 25*25*16 guage

20

-

794

... More
Random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in:

-

-

-

... More
Cement Mortar 1:4 ( 1 cement : 4 Sand )

10

-

2740

... More
Random Rubble stone masonary for superstructure above plinth level one storey height above 30 cm. thick walls in :

-

-

-

... More
Cement mortar 1:4 ( 1 Cement : 4 Sand )

10

-

3060

... More
Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish:

-

-

-

... More
20 mm thick

20

-

210

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding

-

-

-

... More
New Work ( Three or more coats)

30

-

70

... More
Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade :

-

-

-

... More
New steel work ( two or more coats)

16

-

50

... More
Construction of recharge structure

-

-

-

... More
E/W in excavation over areas (exceeding 30 cm in depth,1.5 mtr. In width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50m and lift up to 1.5 mtr. Disposed earth to be leveled and neatly dressed.

-

-

-

... More
(A) All kind of soil.

270

-

203

... More
(B) Ordinary Rock.

174

-

444

... More
Providing and laying in position cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering -All work up to plinth level.

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ).

0.96

-

2918

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ).

2.28

-

3861

... More
Structural steel work in single section fixed without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height. In Flates, Tees, Angles, & Channel etc.

60

-

66

... More
Supply of Coarse Sand .

16.2

-

700

... More
Providing and fixing Grevels

-

-

-

... More
(A) 6 mm nominal size Crusher broken.

8.1

-

800

... More
(B) 20 mm nominal size Crusher broken.

8.1

-

800

... More
(C) 100 mm hand broken.

10.8

-

700

... More
(D) 300 mm hand broken.

81

-

550

... More
Plaster on New surface on wall in cement sand mortar 1:3 including raking of Joints etc. complete fine finish. 20 mm thick.

99

-

282

... More
Providing & Fixing Wire Mesh: 14 Mesh x 24.0 gauze

162

-

500

... More
Random rubble dry stone kharanja under floor

30

-

979

... More
Providing & Lowering of ISI mark Unplastisized ployvinyl chloride (PVC-U) casing pipe as per IS; 12818 : 2010 or amended upto date and technical specification for tube well or DCB with threading, winding with superior quality of plastic mesh & rope in three layers with end cap complete.

-

-

-

... More
150 mm nominal bore

24

-

594

... More
STONE MASONARY FOR FOUNDATION Random Rubble Stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in cement sand mortar 1:6 (1 cement : 6 sand)

21

-

2111

... More
Making Functional House Tap Connections ( FHTCs ).

-

-

-

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PVC/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PVC saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipe in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

350

-

1429

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.

-

-

-

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

994

-

1786

... More
P& F Bib cock (IS : 8931 mark), superior quality of approved make , brass 400 gm, 15 mm nominal bore.

1344

-

271

... More
Add extra over item no 1.21 & 1.22 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

250

-

40

... More
OPERATION AND MAINTENANCE OF Rising Part of SCHEME for 5 Years.

-

-

-

... More
Maintenance of pipelines irrespective of size & material which includes Repairing of Bursts & leakages pollution control, survey & removal of choking, disconnection of illegal connections, Collection & recording minimum 10 nos. residual chlorine samples during daily supply timings, interconnections and all works related to pipeline network in existing distribution /rising main pipe lines of all sizes by digging out suitable size of pit in soft and loose soil/ hard soil including cutting of Black top, WBM & CC top of road of any size at work site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. For entire job contractor will use their own T & P. Contractor with his own resources shall arrange de-watering,JCB & Tractor compressor if any and restore any amenity at his own cost damaged while performing the work in this item. The work includes daily patrolling and repair the leakages within stipulated time and complete maintenance of pipe line network of rising and distribution pipeline network within the scope of work for per km pipe line per month. Jointing material shall be provided by the department.

-

-

-

... More
Minimum labour for a following kms pipelines to be deployed.

-

-

-

... More
1 km to 50 km - one fitter-II & one beldar

-

-

-

... More
1 km to 50 km - one fitter-II & one beldar

597

-

787

... More
Daily/ periodical operation of valves at supply times for specified by department per sluice valve per month. (Valve rod and cap to be arranged by contractor)

-

-

-

... More
80-300mm

1080

-

1200

... More
Maintenance of tubewells which includes complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of Histroy sheet as directed by Engineer-in-charge for tubewell per month.

-

-

-

... More
0.5 HP to 5.0 HP

480

-

1736

... More
Maintenance of centrifugal pump sets and motor/ Monoblock including cost of rewinding of motor, material components & accessories required to repair pumpsets, starters etc. of electric panels, deinstallation and re installation of pumpsets complete in all respect for per Centrifugal pump set with pannel per month. maintenance of histroy sheet as directed by Engineer-in-charge for centrifugal pump set per month. Operated load of Centrifugal Pump sets (HP)

-

-

-

... More
6.0 HP to 7.5 HP

420

-

2003

... More
0.5 HP to 2.5 HP

360

-

1396

... More
Providing and fixing of power factor control capacitor panel with Mtc. on monthly rental basis. The responsibility of contractor is to maintain minimum power factor as 0.96 If the contractor is failed to maintain minimum PF, and any surcharge on this account is levied by JVVNL the same shall be deducted from payment of contractor

6930

-

24

... More
Supply, installation, testing and commissioning of Solar Panghat with TW at habitation (Pata farat)

-

-

-

... More
Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including cable from controller to motor pumps.. Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope . Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switch be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge.

-

-

-

... More
3.7 KW (5.0 HP)

1

-

127082

... More
Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.

3730

-

37

... More
Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On the Polyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item . The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701, ISI marked, indicating the BIS license No.) of approved make with cover. Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled .

-

-

-

... More
Note: There shall be 5 year service warranty for structure, tank, fittings etc. and suitable provision shall be included in tender document.

-

-

-

... More
7500 Liter X 2 Nos. PE water tank, staging 10 meter.

1

-

639105

... More
Supply, installation, testing and commissioning of Remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete. Web charges and data charges for 5 year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer.

1

-

43500

... More
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.

1

-

1100

... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50 mm dia

120

-

597

... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.

2

-

600

... More
Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.

-

-

-

... More
Nominal bore 150 mm dia.

100

-

769

... More
Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of Tube well is more than 100 mtr.

50

-

884.35

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)

15

-

1860

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.

-

-

-

... More
150 mm dia

1

-

700

... More
Supply, installation, testing and commissioning of Solar Panghat with TW at habitation (nichali bhagal )

-

-

-

... More
Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including cable from controller to motor pumps.. Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope . Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switch be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge.

-

-

-

... More
3.7 KW (5.0 HP)

1

-

127082

... More
Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.

3730

-

37

... More
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -

-

-

-

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).

-

-

-

... More
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm

-

-

-

... More
For capacity 50 KL.

-

-

-

... More
25KL GLSR nichali bhagal

25000

-

9.78

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

6

-

1016

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

300

-

586

... More
Supply, installation, testing and commissioning of Remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete. Web charges and data charges for 5 year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer.

1

-

43500

... More
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.

1

-

1100

... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50 mm dia

120

-

597

... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.

2

-

600

... More
Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.

-

-

-

... More
Nominal bore 150 mm dia.

100

-

769

... More
Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of Tube well is more than 100 mtr.

50

-

884.35

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)

15

-

1860

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.

-

-

-

... More
150 mm dia

1

-

700



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.