Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Eprocure
Opening Date27 Apr 2021
Closing Date26 May 2021
Tender Amount₹ 13,85,00,000 
Notes
Download

Costs

  • EMD

    ₹ 27,70,000
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 1,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of tube well after completion of drilling by rotary /percussion/odex method & upto 150 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.

-

-

-

... More
Nominal bore 200 mm dia.

2675

-

1025

... More
Development of tube well as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable compressor to give sand free water for required yield of the gravel packed tube well.

170

-

979

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)

835

-

1841

... More
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.

-

-

-

... More
11 KW (15 HP) & head up to 120 mtr.

498

-

4290

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
16.0 Sq.mm, 4 core

540

-

191

... More
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.

-

-

-

... More
Above 15 HP

18

-

24190

... More
STAR DELTA STARTER 25.0 HP - (1W+ 1S): I/C - MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights (Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block (2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2)

-

-

-

... More
25 HP

2

-

85463

... More
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.

-

-

-

... More
3 core 6.0 Sq.mm

6172

-

204

... More
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

18

-

2800

... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.

35

-

450

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.

-

-

-

... More
200 mm dia

21

-

750

... More
Providing & Lowering in tube well ISI marked GI Pipe “B" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50 mm dia

2145

-

489

... More
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.

-

-

-

... More
50 mm dia

20

-

11201

... More
Rising Main

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr.

-

-

-

... More
In all type of soil

-

-

-

... More
For HDPE pipe line dia up to 110 mm

14250

-

82

... More
For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm.

3900

-

128

... More
For dia of pipe above 150 mm and up to 350 mm nominal.

400

-

180

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
100 mm

9550

-

1145

... More
150 mm

3900

-

1644

... More
200 mm

400

-

1984

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

-

-

-

... More
MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet)

2650

-

103

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-80 PN-6

-

-

-

... More
75 mm dia

200

-

162

... More
110 mm dia

4500

-

360

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

343.6

-

802

... More
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.

210

-

3452

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

148

-

5138

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
80 mm HW

14

-

4695

... More
100 mm HW

40

-

6468

... More
150 mm HW

4

-

10205

... More
200 MM HW

2

-

16802

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date), Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside, Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.0

-

-

-

... More
40 mm

19

-

9115

... More
50 mm

2

-

9498

... More
Construction of RCC Valve Chamber(34Nos)

-

-

-

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.

-

-

-

... More
All kind of soil.

117.98

-

203

... More
Providing and laying in position cement concrete including curing compaction etc complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. using crusher broken aggregate.

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

10.88

-

2918

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Walls ( any thickness) including attached pilaster buttresses , plinth and string course

367.2

-

282

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc.

76.5

-

223

... More
RCC work including atteched pilasters ,buttresses, plinth and string coureses, fillets,columns,pillers, abutements, posts etc. upto floor three level including curing,compaction,finishing 1:1.5:3.(M-20).

49.64

-

5021

... More
Providing and fabricatting reinforcement for RCC work including straightening, cutting, bending, and placing in position in binding (including cost of binding wire) All complete up to floor Three level. Thermomechanically Treated bars (Conforming of relevent IS code)

2380

-

73

... More
Supply and fixing R.C.C. Main holes cover with frame of approved make (Light duty).(450 mm Dia)

34

-

937

... More
Storage

-

-

-

... More
Construction of RCC INTZE type Head Service Reservoir of following capacity and staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges including providing and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS screen, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height of ground level to top level, chambers for all valves, providing and applying three coats of cement paint to the external surfaces of container, column, bracing, carbonation paint on external surface of top dome, food grade epoxy paint on internal surface and giving satisfactory hydraulic test and water tightness test as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes conducting SBC test, design and proof check of reservoirs (if required),painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr(start of RCC reservoir) and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work .

-

-

-

... More
The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete.

-

-

-

... More
Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below:

-

-

-

... More
The rates are applicable for staging height of 18 M. These rates shall be increased or decreased for variation in the staging height as below

-

-

-

... More
Rates for RCC OHSR, SBC 10T/sqm, seismic zone II and Staging 18 Meter.

-

-

-

... More
150 KL capacity At Bordamal

150000

-

18.08

... More
200 KL capacity At jhali ji ka barana

200000

-

17.08

... More
200 KL capacity At Ishawarnagar

200000

-

17.08

... More
200 KL capacity At KARWALA

200000

-

17.08

... More
200 KL capacity At RADI CHADI

200000

-

17.08

... More
200 KL capacity At Rangpuriya

200000

-

17.08

... More
300 KL capacity At jaisthal

300000

-

15.19

... More
300 KL capacity At ROTEDA

300000

-

15.19

... More
500 KL capacity At Arnetha shripura

500000

-

13.41

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
100 mm

310

-

1782

... More
150 mm

480

-

2583

... More
200 mm

160

-

3349

... More
300 MM

25

-

5724

... More
Construction of RCC Valve Chamber(21Nos)

-

-

-

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.

-

-

-

... More
All kind of soil.

72.87

-

203

... More
Providing and laying in position cement concrete including curing compaction etc complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. using crusher broken aggregate.

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

6.72

-

2918

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Walls ( any thickness) including attached pilaster buttresses , plinth and string course

226.8

-

282

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc.

47.25

-

223

... More
RCC work including atteched pilasters ,buttresses, plinth and string coureses, fillets,columns,pillers, abutements, posts etc. upto floor three level including curing,compaction,finishing 1:1.5:3.(M-20).

30.66

-

5021

... More
Providing and fabricatting reinforcement for RCC work including straightening, cutting, bending, and placing in position in binding (including cost of binding wire) All complete up to floor Three level. Thermomechanically Treated bars (Conforming of relevent IS code)

1470

-

73

... More
Supply and fixing R.C.C. Main holes cover with frame of approved make (Light duty).(450 mm Dia)

21

-

937

... More
Construction of RCC Clear Water Reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.

-

-

-

... More
The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete.

-

-

-

... More
Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below:

-

-

-

... More
For foundation on SBC 7 MT/sqm applicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%

-

-

-

... More
For foundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%.

-

-

-

... More
For foundation on SBC more than 18MT/sqm rates decreased by 5 %

-

-

-

... More
Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones.

-

-

-

... More
Rates for RCC Rectangular Flat Slab CWR, SBC 10T/sqm, seismic zone II .

-

-

-

... More
up to100 KL capacity (50KL)At RADI CHADI

50000

-

7.12

... More
up to100 KL capacity (100KL)At ROTEDA

100000

-

7.12

... More
Distribution System

-

-

-

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
100 mm

8250

-

1145

... More
150 mm

4550

-

1644

... More
300 MM

20

-

3271

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
HDPE PE-80 PN-6

-

-

-

... More
75 mm dia

8588

-

162

... More
90 mm dia

11415

-

236

... More
110 mm dia

8650

-

360

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.

-

-

-

... More
HDPE PE-80 PN-6

-

-

-

... More
125 mm dia

306

-

493

... More
140 mm dia

261

-

615

... More
160 mm dia

39

-

772

... More
180 mm dia

46

-

968

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

-

-

-

... More
MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet)

4800

-

103

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
80 mm HW

86

-

4695

... More
100 mm HW

61

-

6468

... More
125 mm HW

2

-

8357

... More
150 mm HW

32

-

10205

... More
200 mm HW

1

-

16802

... More
300 mm HW

1

-

34105

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr.

-

-

-

... More
In all type of soil

-

-

-

... More
For HDPE pipe line dia up to 110 mm

45304

-

82

... More
For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm.

6017

-

128

... More
For dia of pipe above 150 mm and up to 350 mm nominal.

105

-

180

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

3757

-

802

... More
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous courses

120

-

356

... More
Granular courses

25

-

247

... More
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.

1000

-

3452

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

2080.36

-

5138

... More
Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)

-

-

-

... More
a)    60 mm thick.

200

-

237

... More
b)    80 mm thick.

350

-

268

... More
Construction of RCC Valve Chamber(24Nos)

-

-

-

... More
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m.

-

-

-

... More
All kind of soil.

83.28

-

203

... More
Providing and laying in position cement concrete including curing compaction etc complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. using crusher broken aggregate.

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

7.68

-

2918

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Walls ( any thickness) including attached pilaster buttresses , plinth and string course

259.2

-

282

... More
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc.

54

-

223

... More
RCC work including atteched pilasters ,buttresses, plinth and string coureses, fillets,columns,pillers, abutements, posts etc. upto floor three level including curing,compaction,finishing 1:1.5:3.(M-20).

35.04

-

5021

... More
Providing and fabricatting reinforcement for RCC work including straightening, cutting, bending, and placing in position in binding (including cost of binding wire) All complete up to floor Three level. Thermomechanically Treated bars (Conforming of relevent IS code)

1680

-

73

... More
Supply and fixing R.C.C. Main holes cover with frame of approved make (Light duty).(450 mm Dia)

24

-

937

... More
Civil Works

-

-

-

... More
Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect.

-

-

-

... More
At Roteda (10X4 sqm)

40

-

16225

... More
At Radi-Chadi(6X4 sqm)

24

-

16225

... More
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect.

805.59

-

4719

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.

4100

-

87

... More
Recharge Structure

-

-

-

... More
E/W in excavation over areas (exceeding 30 cm in depth,1.5 mtr. In width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50m and lift up to 1.5 mtr. Disposed earth to be leveled and neatly dressed.

-

-

-

... More
(A) All kind of soil.

360

-

203

... More
(B) Ordinary Rock.

232

-

444

... More
Providing and laying in position cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering -All work up to plinth level.

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ).

1.28

-

2918

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ).

3.04

-

3861

... More
Structural steel work in single section fixed without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height. In Flates, Tees, Angles, & Channel etc.

80

-

66

... More
Supply of Coarse Sand .

21.6

-

700

... More
Providing and fixing Grevels

-

-

-

... More
(A) 6 mm nominal size Crusher broken.

10.8

-

800

... More
(B) 20 mm nominal size Crusher broken.

10.8

-

800

... More
(C) 100 mm hand broken.

14.4

-

700

... More
(D) 300 mm hand broken.

108

-

550

... More
Plaster on New surface on wall in cement sand mortar 1:3 including raking of Joints etc. complete fine finish. 20 mm thick.

132

-

282

... More
Providing & Fixing Wire Mesh: 14 Mesh x 24.0 gauze

216

-

500

... More
Random rubble dry stone kharanja under floor

40

-

979

... More
Providing & Lowering of ISI mark Unplastisized ployvinyl chloride (PVC-U) casing pipe as per IS; 12818 : 2010 or amended upto date and technical specification for tube well or DCB with threading, winding with superior quality of plastic mesh & rope in three layers with end cap complete.

-

-

-

... More
150 mm nominal bore

32

-

594

... More
STONE MASONARY FOR FOUNDATION Random Rubble Stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in cement sand mortar 1:6 (1 cement : 6 sand)

28

-

2111

... More
Pumping Machinery

-

-

-

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee.

-

-

-

... More
Centrifugal Monoblock Pump set (Single Stage)

-

-

-

... More
20.0 HP

4

-

80090

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6

-

-

-

... More
100 mm dia

9

-

9011

... More
Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6

-

-

-

... More
80 mm dia

18

-

2393

... More
100 mm dia.

14

-

2688

... More
STAR DELTA STARTER 20.0 HP (1W+ 1S): I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)

3

-

80503

... More
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
BFM100 mm

3

-

16372

... More
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.

4

-

800

... More
FHTC

-

-

-

... More
Providing service connection as per technical specification and standard drawing as per relevant IS code (amended upto date) from all kind of water mains up to consumer Meter/ premises (completed job) this job includes digging out suitable size of pets and trench for laying service line in all kind of soil including demolition of cement concrete wbm, black top etc. of all thickness; cutting of CC road / Jhiri by using a concrete cutter machine; depositing and refilling of pit and Jhiri with watering and ramming/ compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 metre; providing and fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS clamp with saddle piece gunmetal ferrule 4.0 mm (ISI) make gun metal NRV (isi Make), valve( IS 778) and specials with mdpe pipe pe-80 pn-12.5 as per ISO 4427 below ground level and P&F GI pipe 15mm dia class B (ISI Mark) above ground level in the premises for fixing tap ( maximum lenth with flashing, cleaning, disinfecting and testing of pipe line complete required fo mtr.)P &f service connection complete in all respect including mm bib cock with foam flow chrome plated with complete brass body including brass handle having good quality with wt 300 to 325 gm including accessories with flushing ,cleaning, disinfection and testing of pipe line complete requried for making of service connection complete in all respect including labour charges. in addition to the ferrule and orifice of 4 mm dia should also be provided in the service line at the entry point of the consumer's property in such a way that it should be accessible for inspection of VWSE,PHED and any other authorty which would be like to be inspect as and when required the service line should be laid at least 45 CM below ground level, except in case of concrete bituminous roads where minimum depth Shal be 20 cm. For detailed specification of MDPE pipeS please refer section technical specifications of bid document. general specification of mdpe pipe shall be under: The raw material Shal be virgin PE-80 blue compound any comply with the requirement of ISO/directive of testing material; 9080 with minimum required of strength of 8 kg/ per cm. The raw material shall be Food grade quality pressure rating Shall be 12.5 bar. The Pipe Shal bear iso marking

-

-

-

... More
Average length up to 05 mtr 20mm dia MDPE pipe.and 02 mtr 15mm GI Pipe Class B

4014

-

2249



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.