Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date28 Oct 2024
Closing Date11 Nov 2024
Tender Amount₹ 1,20,00,000 
Notes
Download

Costs

  • EMD

    ₹ 2,40,000
  • Document Cost

    ₹ 2,000
  • Tender Fee

    ₹ 2,000

Summary

Construction And Commissioning Of Bore Hole By Dth/rotary/combination Rig Of 200 Mm Dia Supply And Installation Under Sub Div. Makrana With 24 Months Defect Liability, 3 Years Operation And Maintenance After Completion Of Defect Liability Period Arc

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction and Commissioning of bore hole by DTH/Rotary/ Combination rig of 200 mm dia supply and installation under Sub Div. Makrana with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period (ARC)
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .

1

1415

1415.7

... More
Construction of Tube Well from ground level and upto 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe.

-

-

-

... More
Nominal bore 200 mm dia

1

1227

1227

... More
Add 15% extra on above item (Item No 2.01) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .

1

1411

1411.05

... More
Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.

-

-

-

... More
Nominal bore 200 mm dia.

1

1263

1263

... More
Add 15% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.

1

1452

1452.45

... More
Add 30% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .

1

1641

1641.9

... More
Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.

-

-

-

... More
Nominal bore 200 mm dia.

1

1089

1089

... More
Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.

1

1252

1252.35

... More
Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .

1

1415

1415.7

... More
Development of Tube well as per I.S.11189:1985 and IS-2800 (Part-I):1991 (both amended upto date) using suitable compressor to give sand- free water for required yield of the gravel packed TW

1

1456

1456

... More
Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-2000 or as amended up to date

-

-

-

... More
200 mm dia nominal bore of 5.4 mm thickness

1

317

317

... More
Supply of ERW M.S. black casing pipe ISI marked (IS : 4270/2001) or amended upto date of grade Fe 410 of following sizes

-

-

-

... More
200 mm dia nominal bore of 5.4 mm thickness and mass of tube 28.46 Kg/m)

1

2734

2734

... More
Providing & Lowering in tubewell ISI marked GI Pipe "B" class as per IS : 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
50 mm dia

1

678

678

... More
Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc.

-

-

-

... More
3 core 6.0 mm2

1

283

283

... More
3 core 10.0 mm2

1

484

484

... More
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.

-

-

-

... More
16.0 Sq.mm, 4 core

1

234

234

... More
Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS : 8034-2011 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect.

-

-

-

... More
Up to 5.5 KW (7.5 HP) & head above 120 mtr.

1

9628

9628

... More
7.5 KW (10 HP) & head above 120 mtr.

1

8320

8320

... More
9.3 KW (12.5 HP) & head above 120 mtr

1

7552

7552

... More
11 KW (15 HP) & head above 120 mtr.

1

6577

6577

... More
S&F MS clamps set of 50 mm x 6 mm flat form iron with nuts and bolts etc for holding the riser pipe assembly of submersible pumpset

1

696

696

... More
Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relya, ampere n meter with CTs, volt meter, phase preventor, suitable starting copacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out form 18 guage MS sheet with powder coating. panel should be of minimum size 900 X 600 x 450 mm with stand (made of angle iron of size 35x35x5m) duly bolted/ screwed with enclosure box having 4 legs, each leg's length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC plate form should be equal or bigger thatn the base size of panel having height of at least 200 mm from gound level. The panel should have opening of suitable size in fron of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt AC supply

-

-

-

... More
Above 10 HP and up to 15 HP

1

27829

27829

... More
Above 15 HP and up to 20 HP

1

32117

32117

... More
Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 65 mm dia

1

2506

2506

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 MM DIA

1

986

986

... More
Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.

1

1106

1106

... More
Testing verticality of tube well by plumping system and yield test and draw down test by pumping system as per IS : 2800 (Part- II) - 1979 as amended up to date

1

8178

8178

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
80 MM DIA

1

9137

9137

... More
100 MM DIA

1

11554

11554

... More
Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water.

-

-

-

... More
Nominal bore 200 mm dia.

1

1344

1344

... More
Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.

1

4109

4109

... More
Maintiance of TWs which includes round the the clock monitoring of TWs of all sizes, complete including cost of material components required to repair pump sets, staters meters etc. of electrict panel of TWs, lowering and unlowreing of pump sets complete in all respect maintiance of log book and histrory sheets as directed by Engiener - in- charge for TW per month. (excluding repairing of Pump sets)

-

-

-

... More
O&M for Third Year

1

3125

3125

... More
O&M for Fourth Year

1

3125

3125

... More
O&M for Fifth Year

1

3125

3125



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.