Public Health Engineering Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 2,40,000Document Cost
₹ 2,000Tender Fee
₹ 2,000
Summary
Construction And Commissioning Of Bore Hole By Dth/rotary/combination Rig Of 200 Mm Dia Supply And Installation Under Sub Div. Makrana With 24 Months Defect Liability, 3 Years Operation And Maintenance After Completion Of Defect Liability Period Arc
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHCJA_429403_1Bid Award Id
ViewTender No
NIT NO 32/2024-25Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phedwater.rajasthan.gov.in/phed
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction and Commissioning of bore hole by DTH/Rotary/ Combination rig of 200 mm dia supply and installation under Sub Div. Makrana with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period (ARC)
BOQ Items
Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
1
1415
1415.7
Construction of Tube Well from ground level and upto 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe.
-
-
-
Nominal bore 200 mm dia
1
1227
1227
Add 15% extra on above item (Item No 2.01) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .
1
1411
1411.05
Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.
-
-
-
Nominal bore 200 mm dia.
1
1263
1263
Add 15% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
1
1452
1452.45
Add 30% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
1
1641
1641.9
Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.
-
-
-
Nominal bore 200 mm dia.
1
1089
1089
Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
1
1252
1252.35
Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
1
1415
1415.7
Development of Tube well as per I.S.11189:1985 and IS-2800 (Part-I):1991 (both amended upto date) using suitable compressor to give sand- free water for required yield of the gravel packed TW
1
1456
1456
Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-2000 or as amended up to date
-
-
-
200 mm dia nominal bore of 5.4 mm thickness
1
317
317
Supply of ERW M.S. black casing pipe ISI marked (IS : 4270/2001) or amended upto date of grade Fe 410 of following sizes
-
-
-
200 mm dia nominal bore of 5.4 mm thickness and mass of tube 28.46 Kg/m)
1
2734
2734
Providing & Lowering in tubewell ISI marked GI Pipe "B" class as per IS : 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
-
-
-
50 mm dia
1
678
678
Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc.
-
-
-
3 core 6.0 mm2
1
283
283
3 core 10.0 mm2
1
484
484
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
16.0 Sq.mm, 4 core
1
234
234
Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS : 8034-2011 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect.
-
-
-
Up to 5.5 KW (7.5 HP) & head above 120 mtr.
1
9628
9628
7.5 KW (10 HP) & head above 120 mtr.
1
8320
8320
9.3 KW (12.5 HP) & head above 120 mtr
1
7552
7552
11 KW (15 HP) & head above 120 mtr.
1
6577
6577
S&F MS clamps set of 50 mm x 6 mm flat form iron with nuts and bolts etc for holding the riser pipe assembly of submersible pumpset
1
696
696
Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relya, ampere n meter with CTs, volt meter, phase preventor, suitable starting copacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out form 18 guage MS sheet with powder coating. panel should be of minimum size 900 X 600 x 450 mm with stand (made of angle iron of size 35x35x5m) duly bolted/ screwed with enclosure box having 4 legs, each leg's length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC plate form should be equal or bigger thatn the base size of panel having height of at least 200 mm from gound level. The panel should have opening of suitable size in fron of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt AC supply
-
-
-
Above 10 HP and up to 15 HP
1
27829
27829
Above 15 HP and up to 20 HP
1
32117
32117
Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 65 mm dia
1
2506
2506
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 MM DIA
1
986
986
Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.
1
1106
1106
Testing verticality of tube well by plumping system and yield test and draw down test by pumping system as per IS : 2800 (Part- II) - 1979 as amended up to date
1
8178
8178
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
-
-
-
80 MM DIA
1
9137
9137
100 MM DIA
1
11554
11554
Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water.
-
-
-
Nominal bore 200 mm dia.
1
1344
1344
Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.
1
4109
4109
Maintiance of TWs which includes round the the clock monitoring of TWs of all sizes, complete including cost of material components required to repair pump sets, staters meters etc. of electrict panel of TWs, lowering and unlowreing of pump sets complete in all respect maintiance of log book and histrory sheets as directed by Engiener - in- charge for TW per month. (excluding repairing of Pump sets)
-
-
-
O&M for Third Year
1
3125
3125
O&M for Fourth Year
1
3125
3125
O&M for Fifth Year
1
3125
3125
Evaluation Notes How It Works ?