If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 9,08,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_CERJ_94431_6Bid Award Id
ViewTender No
NIT No. 02/PMGSY/2020-21 ACE PWD Zone BharatpurTender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Setting Out
Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108.
6.5
-
50915
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
3
-
10902
Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
8250.5
-
29
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 50 m as per MoRD Specification Clause 301.5
40520.25
-
55
PART - B : WBM/W.M.M. WORK Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401.For Grading III Material
8304.66
-
584
WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per MoRD Specification Clause 405.
Using Crusher Broken Aggregate
By Manual Means
3245.63
-
1133
WBM Grading 3
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. Using Crusher Broken aggregate
By Manual Means
2691.56
-
1188
PART - C : B.T. WORK Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502
28762.5
-
49
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503.
41100
-
11
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 508.
Case - II By Mechanical Means
Bitumen (VG-30)
Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications)
41100
-
104
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 510
By Mechanical Means Case - II : Type B Bitumen (VG-30)
41100
-
36
PART- D : ROAD FURNISHING Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th kilometre stone (precast)
2
-
2485
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer stone (Precast)
12
-
1477
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Hectometer stone (Precast)
51
-
337
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701. upto 0.9 sqm size board
10.8
-
8835
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 900 mm equilateral triangle
30
-
4241
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 800 mm x 600 mm rectangular
18
-
5226
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
6
-
4007
Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
2
-
13916
Providing and Fixing informatory sign board with Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
2
-
12962
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
348
-
551
Boundary Pillar, Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Specification Clause 1704
20
-
383
Supply of Chevron sign of size 75x60 cm made out of aluminum sheet 2 mm thick with fixing provision on M.S. angle iron post 50x50x6 mm 3 M long screwed with stainless steel nut bolts of 8 M dia, plate is covered by high intensity grade yellow retro-reflective sheeting and black screen printed arrow on Retro Reflective Sheet, complete in all respect. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom
72
-
5865
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810
80
-
2289
Supplying of Cat’s Eye made of aluminium alloy size 75x100x22 mm having 21 biconvex lenses embedded in circular disk of ABS plastic on each side.
1000
-
242
Supply of Swiss type of Hazard marker, made out of 2 mm thick M.S. sheet size of box is 15x15 cm with hold fast at bottom, the body is painted in orange stoving enamel paint with white/high intensity grade micro-prismatic type sheeting, on all four side.
24
-
1059
PART- E : C.C. PAVEMENT WBM Grading 3
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Specification Clause 405. Using Crusher Broken aggregate
By Manual Means
281.25
-
1188
Providing, fabricating and lying form work of plastic cells made from reclaimed High Density Polythelene (HDPE) sheets of thickness 0.20mm to about 0.25mm or LDPE sheets of thickness 0.30mm to 0.35mm thickness, 100mm wide heat welded or stitched to form cell at 300mm interval and fixed with iron spikes of about 200mm long to keep the cell walls taut and with nylon threads to prevent collapse of the cell walls during placement of concrete, form work of cells should be so stiched to form a roll of cells of a pavement width 3.75m and has a length of 10m to 20m and successive rolls of cell to be stapled.
2812.5
-
116
Construction of plastic cell filled cement concrete pavement, with M30 grade concrete, thickness as per design, over a prepared sub base, with 53 grade Ordinary Portland Cement (OPC) or any other type as per Clause 1501.2.4 M30 (Grade). Coarse and fine aggregates conforming to IS : 2386, maximum in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design(As per IRC 44-2088, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using screed and plate vibrators and finished in continuous operation, Concrete should have a slump of 30-50MM with use of approved plasticizer if required Formwork of plastic cells should be made of High Density Polyethylene (HDPE), sheets having thickness ranging from 0.19-0.22MM with sides 150MMx150MM and height as fixed by engineer in charge. To be laid in full width of the carriageway. Iron spikes of about 200MM long are to be used to keep the cell walls taut. Nylon thread or rope may be used to prevent collapse of cells during placement of concrete. Iron spikes to be taken out for use in other place as soon as the concrete is in place. The sub base should be provided with concrete/stone block or brick on edge on either side of the carriageway protecting the sub base with full thickness of the concrete pavement for its confinement and protection. curing of concrete slabs for 14 - days, curing compound ( where specified) and water finishing to lines and grade as per drawing and MoRD Specification of cell filled Concrete Pavement.
2812.5
-
592
Construction of un-reinforced, without dowel bar, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound and water finishing to lines and grade as per drawing and MoRD Specification Clause 1501 including vaccum dewatering process with all required equipments
592.5
-
5083
Plain/reinforced cement concrete in substructure complete as per drawings and MoRD specification Clauses 802, 804, 805, 806, 807, 1202 and 120
For height upto 5 m
P.C.C grade M 15
Nominal mix (1:2.5:5)
385
-
3447
Providing and Laying of Interlocking M-30 grade Concrete Block Pavements having thickness 50 mm as per drawings and MoRD Specification Clause 1504with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks.
Category 'A' : Dentated units to key into each other on all four faces Zigzag shape as per IRC:SP:63-2004
3850
-
675
PART- F : SYPHON Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth
243
-
211
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10, Nominal mix 1:3:6
50.12
-
3255
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 300 mm dia
315
-
787
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203.In 1:4 cement mortar
93.74
-
2852
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.1175 mm thick
31.5
-
319
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
105
-
150
PART - G : PROTECTION WALL Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth
434.2
-
211
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10, Nominal mix 1:3:6
65.13
-
3255
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203.In 1:4 cement mortar Random Ruble Masonry
526.05
-
2852
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11.
75 mm thick
150.3
-
319
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Raised and Cut Type
334
-
75
PART - H : HUME PIPE CULVERT 1000MM DIA DOUBLE ROW Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth
278.16
-
211
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10, Nominal mix 1:3:6
14.5
-
3255
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203. Random Ruble. In 1:4 cement mortar
155.6
-
2852
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix (1:2:4)
29.08
-
3610
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per Design in Double Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106.1000 mm dia
15
-
7932
Pointing with cement mortar (1:3) on Stone work as per drawing and MoRD specification Clauses 613.3 and 1204 Raised and Cut Type
60.42
-
75
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11.
75 mm thick
79.43
-
319
PART - I : Drain Work Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth
2790
-
211
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10, Nominal mix 1:3:6
558
-
3255
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203.In 1:4 cement mortar Random Ruble masonry
868
-
2852
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11.
75 mm thick
3100
-
319
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
1860
-
150
Routine Maintenance after Completion of Construction Work
-
-
-
1st year -
12.65
-
23132.36
2nd year -
12.65
-
29595.82
3rd year -
12.65
-
38100.36
4th year -
12.65
-
44563.82
5th year -
12.65
-
51707.64
Evaluation Notes How It Works ?