Pradhan Mantri Gram Sadak Yojana Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Eprocure
Opening Date2 Jul 2020
Closing Date24 Jul 2020
Tender Amount₹ 6,10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with all lead and lift., trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per MoRD Specification Clause 302.3.5 Mechanical Means

1068.49

-

269

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with all lead and lift., trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per MoRD Specification Clause 302.3.5

7479.46

-

51

... More
Construction of embankment with approved material obtained from borrow pits with all lift , transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with all lead and lift as per Technical Specification Clause 301.5 (A) Material obtained from Private land

14494.08

-

132

... More
Construction of embankment with approved materials deposited at site obtained from roadway cutting and excavation from drain and foundation or other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per MoRD Specification Clause 301.5 Used for filling from cutting qty. as per Item No.(i),(ii) & (iii)

21369.88

-

37

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with all lead and lift as per MoRD Specification Clause 303.1.

5775

-

55

... More
Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108.

11

-

50915

... More
PART -" B" - WBM & Hard Shoulder Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading II Material

4194.34

-

588

... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and MoRD Specification Clause 406. By Mechanical Means with all lead and lift.

7329.42

-

1179

... More
PART -" C" - B.T. Work Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502

52565.7

-

49

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per MoRD Specification Clause 503.

52565.7

-

9

... More
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site with all leads laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per MoRD Specification Clause 504. with 3.3% to 3.5% Bitumen (VG-30)

2628.29

-

5020

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing of aggregate and plastic waste cutting in a hotmix plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 508. Waste Plastic @ 8% of bitumen. Case -II By mechnical means Bitumen VG-30

52565.7

-

104

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 By Mechanical Means-Case-II : Type B Bitumen (VG-30)

52565.7

-

36

... More
Part- D :- Road Furnishing Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703. 5th Kilometre Stone (precast)

2

-

2485

... More
Ordinary Kilometer Stone (Precast)

12

-

1477

... More
200 m stone (precast)

44

-

337

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Specification Clause 1704

132

-

383

... More
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 2mm thick MS plate framed to angle Iron 40x40x6mm including orange luminous colour paint on logo, size of diamand plate 600x600mm definition plate 900x250mm supported on MS post of angle Iron of size 65x65x6mm, 3m long stove enameled paint with hold fastfirmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700

7

-

4007

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

4

-

12962

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on RCC Post 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing Clause 1701 900 mm equilateral triangle

66

-

3819

... More
800 mm x 600 mm rectangular

6

-

4804

... More
Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of two MS sheet of 1.6 mm thick each of size 900mm x 750mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of 75mm dia pipe of 12 SWG sheet (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M-15 grade of block of 600mmx 600mm x 750 mm size below ground level as per enclosed drawings & as directed by Engineering incharge. All MS will be stove anmeled on both side lettering. Figuring and border will be with ready mixed synthethic enamel paint of superior quality in required shade and colour etc complete in all respect. All sections of framed post and steel tube will be painted with primer and two coat of epoxy paint as per drawing and as per MoRD Specification.

7

-

12904

... More
Supply of Chevron sign of size 75x60 cm made out of aluminum sheet 2 mm thick with fixing provision on M.S. angle iron post 50x50x6 mm 3 M long screwed with stainless steel nut bolts of 8 M dia, plate is covered by high intensity grade yellow retro-reflective sheeting and black screen printed arrow on Retro Reflective Sheet, complete in all respect. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom

11

-

5865

... More
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810

25

-

2289

... More
Supplying of Cat’s Eye made of aluminium alloy size 75x100x22 mm having 21 biconvex lenses embedded in circular disk of ABS plastic on each side.

110

-

242

... More
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.

50

-

769

... More
Supplying & Fixing Direction and place identification sign board made out of 2 mm thick M.S. sheet framed to angle iron 40x40x5 mm and two vertical posts of angle iron of size 65x65x6 mm 3 meter long with hold fasts, stove enameled paint reflective letter symbol complete of size. :

-

-

-

... More
150 x 120 cm.

11

-

5077

... More
90 x 60 cm.

33

-

3025

... More
60 x 45 cm.

44

-

2257

... More
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.

773.75

-

551

... More
Construction of speed breaker of IRC standard having width of 3.70 M including cost of stone aggregate (50-25mm) size hire charges for roller for consolidation and compaction and other machines required for the work (excluding cost of bitumen)

81.4

-

164

... More
PART 'E' : C.C. ROAD Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound and water finishing to lines and grade as per drawing and MoRD Specification Clause 1501 including vaccum dewatering process with all required equipments

948.3

-

5083

... More
Part ''F'' CD Work Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth Ordinary soil Upto 3 m depth

-

-

-

... More
1000mm dia HP 1 Row

915.6

-

211

... More
1000mm dia HP 2 Row

947.32

-

211

... More
Syphon

160.6

-

211

... More
RCC-Box Culvert-1 Cell- 2.0M x 2.0M

668

-

211

... More
Retaining wall

220.86

-

211

108

-

211

135.98

-

211

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and MoRD specifications Clause 1302

-

-

-

... More
RCC-Box Culvert-1 Cell- 2.0M x 2.0M

384

-

706

94.65

-

706

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and MoRD specifications Clause 1302 Stone/Boulder

-

-

-

29.31

-

836

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 - Nominal mix 1:3:6

-

-

-

... More
1000mm dia HP 1 Row

59.2

-

3255

... More
1000mm dia HP 2 Row

48.84

-

3255

... More
RCC-Box Culvert-1 Cell- 2.0M x 2.0M

63.76

-

3255

... More
Retaining wall

27.61

-

3255

24

-

3255

... More
Syphon

31.5

-

3255

44.34

-

3255

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)

-

-

-

... More
1000mm dia HP 1 Row

368.8

-

3259

... More
1000mm dia HP 2 Row

293.7

-

3259

... More
Syphon

76.29

-

3259

... More
Retaining wall

253.07

-

3259

36

-

3259

103.46

-

3259

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000 mm dia

-

-

-

... More
1000mm dia HP 1 Row

250

-

3966

... More
1000mm dia HP 2 Row

275

-

3966

62.5

-

3966

... More
Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets 500 mm dia

-

-

-

... More
Syphon

125

-

1469

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)

-

-

-

... More
1000mm dia HP 1 Row

3.8

-

3259

... More
1000mm dia HP 2 Row

2.09

-

3259

... More
Plain/reinforced cement concrete in substructure complete as per drawings and MoRD specification Clauses 802, 804, 805, 806, 807, 1202 and 1204. For height upto 5 m R.C.C grade M 20

-

-

-

... More
RCC-Box Culvert-1 Cell- 2.0M x 2.0M

296.8

-

3989

18.75

-

3989

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and MoRD specification Clauses 1002, 1005, 1010 & 1202 Qty as per IRC SP-20

-

-

-

... More
RCC-Box Culvert-1 Cell- 2.0M x 2.0M

29.68

-

46789

... More
Retaining wall

5.05

-

46789

3.06

-

46789

... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 75 mm thick

-

-

-

... More
1000mm dia HP 1 Row

64

-

319

... More
1000mm dia HP 2 Row

52.8

-

319

... More
Retaining wall

49.08

-

319

... More
Syphon

27

-

319

... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per MoRD specification Clauses 613.4 & 1204

-

-

-

... More
1000mm dia HP 1 Row

43.2

-

123

... More
1000mm dia HP 2 Row

21.12

-

123

... More
Syphon

36

-

123

... More
Retaining wall

184.05

-

123

... More
Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i) P.C.C grade M 15 Nominal mix (1:2.5:5)

-

-

-

... More
1000mm dia HP 1 Row

47.2

-

3259

... More
1000mm dia HP 2 Row

58.08

-

3259

11.56

-

3259

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

-

-

-

... More
Retaining wall

62

-

65

22

-

65

... More
Providing and fixing stone slab covering over drains (Kota/Bijoliya Quarry) having thickness 75 mm to 150 mm including filling of joints in cement mortar 1:3 with 50 mm thick cement concrete flooring in 1:2:4 mix complete with good finish as per approved drawings and specifications.for drain Opeining Size 300 to 450 mm Stone Patty drain cover size 800mm x 600mm x 75mm

-

-

-

120

-

745

... More
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301

-

-

-

122.4

-

836

... More
Routine Maintenance after complition construction work

-

-

-

... More
1st Year : 0.68%

11

-

35702.91

... More
2nd Year : 0.87%

11

-

45678.73

... More
3rd Year : 1.12%

11

-

58804.82

... More
4th Year : 1.31%

11

-

68780.64

... More
5th Year : 1.52%

11

-

79806.55

... More
Total Maintenance cost for 5 Years

11

-

288773.64



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.