Power Grid Corporation Of India Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Power Grid Corporation Of India Limited - PGCIL Tender

Goods
Electrical Goods and Equipments
Electrical and Electronics
GEM
Opening Date7 Jan 2025
Closing Date7 Feb 2025
Tender AmountRefer Documents 
Auction Start Date4 Mar 2025
Auction End Date5 Mar 2025
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
624 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 624 kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

5

-

-

... More
624 kV Surge Arrester for WR-I at various locations as mentioned in scope of work in Annex-01 , 1-Phse, 624 kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

20

-

-

... More
624 kV Surge Arrester for NR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phse, 624 kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

3

-

-

... More
390 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 390 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

11

-

-

... More
336 kV Surge Arrester for NR-I Gr-1 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

31

-

-

... More
336 kV Surge Arrester for NR-I Gr-2 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

7

-

-

... More
336 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

5

-

-

... More
336 kV Surge Arrester for WR-I at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

27

-

-

... More
336 kV Surge Arrester for NER at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

20

-

-

... More
336 kV Surge Arrester for WR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

6

-

-

... More
336 kV Surge Arrester for NR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

90

-

-

... More
336 kV Surge Arrester for SR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV, 20KA, 12kJ/kV Surge Arrestor of nominal creepage with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

75

-

-

... More
336 kV Surge Arrester for SR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 336 kV 20KA, 12kJ/kV surge arrestors of creepage 31 mm/kV with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

5

-

-

... More
216 kV Surge Arrester for NR-I Gr-1 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

6

-

-

... More
216 kV Surge Arrester for NR-I Gr-2 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

15

-

-

... More
216 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

5

-

-

... More
216 kV Surge Arrester for NER at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

6

-

-

... More
216 kV Surge Arrester for WR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

6

-

-

... More
216 kV Surge Arrester for WR-I at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

21

-

-

... More
216 kV Surge Arrester for NR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

90

-

-

... More
216 kV Surge Arrester for SR-II at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 216 kV, 10kA, 7kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

69

-

-

... More
132 kV Surge Arrester for NR-I Gr-1 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 132 kV, 20 kA, 12kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 765kV Reactors

4

-

-

... More
132 kV Surge Arrester for NR-I Gr-2 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 132 kV, 20 kA, 12kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 765kV Reactors

5

-

-

... More
132 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 132 kV, 20 kA, 12kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 765kV Reactors

7

-

-

... More
132 kV Surge Arrester for WR-I at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 132 kV, 20 kA, 12kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 765kV Reactors

16

-

-

... More
132 kV Surge Arrester for Kotra PS as mentioned in scope of work in Annex-01 , 1-Phase, 132 kV, 20 kA, 12kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 765kV Reactors

2

-

-

... More
120 kV Surge Arrester for WR-I at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 120 kV, 10KA, 3.5kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 400kV Reactors

9

-

-

... More
120 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 120 kV, 10KA, 3.5kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 400kV Reactors

10

-

-

... More
120 kV Surge Arrester for NR-I Gr-1 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 120 kV, 10KA, 3.5kJ/kV Surge Arrestor of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS for application with NGR of 400kV Reactors

4

-

-

... More
120 kV Surge Arrester for NR-III at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 120 kV, 10KA, 7kJ/kV, Surge Arrester(1-phase) of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables as per POWERGRID TS

1

-

-

... More
60 kV Surge Arrester for NR-I Gr-2 at various locations as mentioned in scope of work in Annex-01 , 1-Phase, 60 kV, 10KA, 7kJ/kV, Surge Arrester(1-phase) of nominal creepage along with insulating Base, Corona Ring and Surge Monitor with necessary leads/cables for application with ICT Tertiary as per POWERGRID TS

2

-

-

... More
624 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Quad Bersimis Conductor (Sub-conductor spacing 450mm) suitable for 624 kV Surge Arrester as per POWERGRID TS

3

-

-

... More
624 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Quad AAC Bull suitable for 624 kV Surge Arrester for connection with Reactor

1

-

-

... More
624 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin Bersimis suitable for 624 kV Surge Arrester for connection with Line

1

-

-

... More
624 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Quad AAC Bull (Horizontal take-off) suitable for 624 kV Surge Arrester for connection with Reactor

1

-

-

... More
624 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal connector 41/2 Inch AL IPS tube sliding type suitable for 624 kV Surge Arrester as per POWERGRID TS

1

-

-

... More
390 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin Moose suitable for 390 kV Surge Arrester as per POWERGRID TS

11

-

-

... More
336 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin Moose suitable for 336 kV Surge Arrester as per POWERGRID TS

5

-

-

... More
336 kV Terminal connector for NER at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin Moose suitable for 336 kV Surge Arrester as per POWERGRID TS

20

-

-

... More
336 kV Terminal connector for SR-II at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin Moose suitable for 336 kV Surge Arrester as per POWERGRID TS

80

-

-

... More
336 kV Terminal connector for WR-II at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin moose suitable for 336 kV Surge Arrester as per POWERGRID TS

6

-

-

... More
216 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Single moose suitable for 216kV Surge Arrester as per POWERGRID TS

5

-

-

... More
216 kV Terminal connector for NER at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Sigle Zebra suitable for 216 kV Surge Arrestor as per POWERGRID TS

6

-

-

... More
216 kV Terminal connector for SR-II at various locations as mentioned in scope of work in Annex-01 , Terminal connector for Twin Moose suitable for 216 kV surge arrestors as per the as per POWERGRID TS

60

-

-

... More
216 kV Terminal connector for SR-II at various locations as mentioned in scope of work in Annex-01 , Terminal connector for Single Zebra suitable for 216 kV surge arrestors as per the as per POWERGRID TS

9

-

-

... More
216 kV Terminal connector for WR-II at various locations as mentioned in scope of work in Annex-01 , Terminal connector for Twin Moose suitable for 216 kV surge arrestors as per the as per POWERGRID TS

6

-

-

... More
132 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Twin Moose type (HORIZANTAL APPROACH) suitable for 132 kV Surge Arrester

7

-

-

... More
120 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Single Moose HORIZANTAL APPROACH) suitable for 120 kV Surge Arrester

10

-

-

... More
120 kV Terminal connector for NR-III at various locations as mentioned in scope of work in Annex-01 , Terminal Connector for Single Moose Through type Vertical type suitable for 120 kV Surge Arrester

1

-

-

... More
Surge Monitor for SR-II at various locations as mentioned in scope of work in Annex-01 , Surge Monitor suitable for 336 kV Surge arrestors as per the as per POWERGRID TS

90

-

-

... More
Surge Monitor for SR-II at various locations as mentioned in scope of work in Annex-01 , Surge Monitor suitable for 216 kV Surge arrestors as per the as per POWERGRID TS

65

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.