Nuclear Fuel Complex Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Nuclear Fuel Complex - NFC Tender
Civil And Construction
Eprocure
Opening Date2 Nov 2021
Closing Date13 Dec 2021
Tender Amount₹ 7,86,00,000
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_NFC_655721_1Bid Award Id
ViewTender No
E/629/2021Tender Authority
Nuclear Fuel Complex ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
ERECTION
2
-
-
Centrifugal pumps: Water recirculation centrifugal pumps suitable to handle water for above mentioned air flow rate.
Accessories: Flexible coupling, mounting frame, etc., MOC: Cast Iron casing with SS impeller
Drive Arrangement Suitable with VFD
(Note: VFD is covered in electrical schedule)
-
-
-
SUPPLY
2
-
-
ERECTION
2
-
-
Plumbing between Spray chamber and Pumps
Piping from spray chamber to/from the pumps. Associated pump accessories : Isolation valves at inlet & outlet, flow regulation valves, NRV/check valve, strainer, etc. Piping from battery limit is also covered in this scope . Necessary fittings : Elbows, tees, couplings, reducers fasteners, clamps.etc, MOC : GI Class B
Dwg: "C-CED/EP(AC&V)NFC(K)-147" for reference.
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
Spray Chamber internals: Supply Installation Testing & Commissioning of three bank water spraying system with header, distributers, HDPV nozzles, marine light, pipe fittings, quick fill make up water line along with float and valve, drain pipe with gate valve, etc.
MOC : GI Class-B
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
Fresh Air Filter Capacity : 2000 CFM Grade : G4 Efficiency : 90% down to 10 micron Filter Media : HDPE Size : 610x610 mm Casing : Aluminium Face guard : Wire mesh type
(Note: Necessary support structure is covered in another item)
-
-
-
SUPPLY
250
-
-
ERECTION
250
-
-
PVC Air distributer (Note: Necessary MS support structure is covered in another item).
-
-
-
SUPPLY
90
-
-
ERECTION
90
-
-
Chevron type PVC Mist eliminator
(Note: Necessary MS support structure is covered in another item).
-
-
-
SUPPLY
90
-
-
ERECTION
90
-
-
Exhaust air Fans : SISW type, backward curved, belt driven. Temperature to be considered is 50deg C. The scope also includes accessories like flexible connections at fan outlet,common base frame, vibration isolators, V-belt, guard, electrical actuator controlled volume control damper at the outlet. MS construction shall be epoxy painted. Static Pressure: 350 mm WC
Drive Arrangement Suitable with VFD
(Note: VFD is covered in electrical schedule )
-
-
-
69100 CFM MOC:Mild Steel
-
-
-
SUPPLY
2
-
-
ERECTION
2
-
-
66700 CFM MOC:Mild Steel
-
-
-
SUPPLY
2
-
-
ERECTION
2
-
-
GI DUCTING: Duct shall be complying to IS: 277, Class IV, Grade 275 GSM.
Accessories included: Supply/Exhaust air collars, vanes, splitters, necessary MS structural members (viz. angle flanges for duct joining, lateral& longitudinal reinforcement, internal tie rods, fasteners), gaskets, sealent, etc. Duct construction shall be as per IS-655/SMACNA standrad. (Note: Necessary duct supporting/hanging structural material (MS) is covered under item)
-
-
-
22 Gauge, Rectangular
-
-
-
SUPPLY
2200
-
-
ERECTION
2200
-
-
18 Gauge, Circular
-
-
-
SUPPLY
1500
-
-
ERECTION
1500
-
-
22 Gauge, Circular
-
-
-
SUPPLY
1300
-
-
ERECTION
1300
-
-
16 Gauge for plenum
-
-
-
SUPPLY
150
-
-
ERECTION
150
-
-
Manually operated Volume Control Dampers Thickness: 16 G Thick
Dimensions: As per Requirement
Measurement: Cross Sectional Flow Area including flanges
-
-
-
Rectangular, MOC: GI
-
-
-
SUPPLY
5
-
-
ERECTION
5
-
-
Circular, MOC: GI
-
-
-
SUPPLY
10
-
-
ERECTION
10
-
-
Electrically operated Volume Control Dampers for ducting with one of the dimensions 1.0 mtr and above Thickness: 16 G Thick
Dimensions: As per Requirement
Measurement: Cross Sectional Flow Area including flanges
-
-
-
Rectangular, MOC: GI
-
-
-
SUPPLY
5
-
-
ERECTION
5
-
-
Circular, MOC: GI
-
-
-
SUPPLY
8
-
-
ERECTION
8
-
-
Actuators for electrically operated Volume Control Dampers
-
-
-
SUPPLY
12
-
-
ERECTION
12
-
-
Non Return damper MOC: SS 304
Thickness: 16 G Thick
Dimensions: As per Requirement
Measurement: Cross Sectional Flow Area including flanges
-
-
-
SUPPLY
5
-
-
ERECTION
5
-
-
Fusible link type Fire dampers
MOC: GI
Thickness: 16 G Thick
Dimensions: As per Requirement
Note: Dampers shall be CBRI tested & certified for minimum 90 minutes rating as per UL 555 Measurement: Cross Sectional Flow Area including flanges
-
-
-
SUPPLY
25
-
-
ERECTION
25
-
-
Supply Air Grills: Type : Double deflection grills/Four Way Diffusers as per layout
MOC: Extruded Aluminium Powder Coated Frame Thickness : 16 G
Accessories : Volume control Dampers
-
-
-
SUPPLY
20
-
-
ERECTION
20
-
-
Return Air diffusers
MOC: Extruded Aluminium Powder Coated Frame Thickness : 16 G
-
-
-
SUPPLY
20
-
-
ERECTION
20
-
-
MS. Structure (For General purpose): Painting : Epoxy painting with primer Scope: Duct supports, Yard Trustels for carrying ducts, supporting stand.
-
-
-
SUPPLY
10000
-
-
ERECTION
10000
-
-
MS. Structure(For retainer frames):
Painting : Epoxy painting with primer Scope: HEPA filter/ Pre Filter/ Fresh Air filter/Air Distributer/ Mist Eliminator etc
-
-
-
SUPPLY
12000
-
-
ERECTION
12000
-
-
Pre-Filters
Grade : G4
Size: 610x 610 mm
Flow Rate: 2000 CFM
Efficiency : 95% down to 10 micron Initial Pressure Drop: 12 mmWC maximum in clean condition
Casing : 1.2 mm thick Aluminium
Media : Non woven Synthetic media sandwiched between 2 layers of HDPE Mesh
-
-
-
SUPPLY
80
-
-
ERECTION
80
-
-
MS Leak tight doors Size : 2.215 x1.115 m Note: For masonary type HEPA/Pre-filter chambers Refer : Drawing no C-CED/EP(AC&V)-142
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
1)Developing CAD drgs pertaining to GA, duct layout drawings as per specifications. 2)Simulation of Air flow pattern by CFD analysis using ANSYS or equivalent software. 3) Developing P&ID drgs of all ventilation systems as per schemes given 4) Assessing TAG numbers to all ventilation equipment 5)Validating of total sytem by smoke test.
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
Design, Engineering, fabrication, transportation, Safe handling, site storage, Installation, Testing & Commissioning of Fully Draw-out type Motor Control Centre for air blowers and pumps as per tender specifications
-
-
-
Damper Control Panel
4P, 63 A MCCB I/C-1Nos.
1 KW DOL starter(3Phase) - 8 Nos
1 KW DOL starter(1 Phase) - 9 Nos
3P+NL, 32A MCCB --- 1 Nos.
-
-
-
SUPPLY
4
-
-
ERECTION
4
-
-
Design, Engineering, fabrication, transportation, Safe handling, site storage, Installation, Testing & Commissioning of Fully Draw-out type VFD Motor Control Centre for air blowers and pumps as per tender specifications
-
-
-
Assembly section Exhaust MCC
4P, 800A EDO type ACB I/C-2Nos.
4P, 800A EDO type ACB B/C-1No.
200kW VFDs --- 2 No.
3P+NL, 400A MCCBs --- 1 Nos.
11kW DOL Starter --2Nos.
3P+NL, 63A MCCBs --- 2 Nos.
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
Assembly Area Supply Air MCC panel (Non-drawout type)
4P, 800A EDO type ACB I/C-2Nos.
4P, 800A EDO type ACB B/C-1No.
3P+NL, 400A MCCBs --- 3 Nos.
110kW VFDs --- 2 Nos.
45kW VFDs --- 2 Nos.
3P+NL, 63A MCCBs --- 2 Nos.
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
Active Waste Storage MCC
4P, 800A EDO type ACB I/C-2Nos.
4P, 800A EDO type ACB B/C-1No.
200kW VFDs --- 2 No.
3P+NL, 400A MCCBs --- 3 Nos.
3P+NL, 63A MCCBs --- 2 Nos.
-
-
-
SUPPLY
1
-
-
ERECTION
1
-
-
Supply, installation, testing and commissioning of 1100 V grade, XLPE insulated and armoured FRLS cables of following sizes as per data sheet, specifications of this tender and directions of Engineer-in-Charge. including transport, all labour and materials, complete in all respects.
-
-
-
3Cx185sqmm copper conductor
-
-
-
SUPPLY
720
-
-
ERECTION
720
-
-
3Cx120sqmm copper conductor
-
-
-
SUPPLY
360
-
-
ERECTION
360
-
-
3Cx 70 sqmm copper conductor
-
-
-
SUPPLY
180
-
-
ERECTION
180
-
-
4Cx 16 sqmm Al conductor
-
-
-
SUPPLY
180
-
-
ERECTION
180
-
-
3Cx 16 sqmm copper conductor
-
-
-
SUPPLY
180
-
-
ERECTION
180
-
-
4Cx2.5sqmm copper conductor
-
-
-
SUPPLY
600
-
-
ERECTION
600
-
-
Termination of XLPE insulated armoured Aluminium/Copper power cables (up to 1100 V grade) and connection of leads including the supply of single compression cable glands and heavy duty copper lugs, drilling of suitable holes in equipments for fixing purposes, including fixing of cable glands, supply and fixing of PVC shrouds, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
-
-
-
3Cx185sqmm copper conductor
-
-
-
SUPPLY
16
-
-
ERECTION
16
-
-
3Cx120sqmm copper conductor
-
-
-
SUPPLY
8
-
-
ERECTION
8
-
-
3Cx 70 sqmm copper conductor
-
-
-
SUPPLY
4
-
-
ERECTION
4
-
-
4Cx 16 sqmm Al conductor
-
-
-
SUPPLY
8
-
-
ERECTION
8
-
-
3Cx 16 sqmm copper conductor
-
-
-
SUPPLY
4
-
-
ERECTION
4
-
-
4Cx2.5sqmm copper conductor
-
-
-
SUPPLY
44
-
-
ERECTION
44
-
-
CABLE – TRAYS : Supply and installation of prefabricated hot dip galvanised steel cable trays,
fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. tender drawing of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
-
-
-
300 mm wide Straight run cable tray.
-
-
-
SUPPLY
300
-
-
ERECTION
300
-
-
Supply, fabrication and installation of 0.91 mm (20 gauge) GI sheet covers for all
sizes cable trays, including necessary hardware, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer- in-Charge.
-
-
-
SUPPLY
90
-
-
ERECTION
90
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements