If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 2,25,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Signalling Work In Connection With Ttr(cs + Tws + Cmsc- 150 Set) Over Jaipur Division.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
SNT-JP-19-2024-25-JAIPUR DIVISION-S AND T/NORTH WESTERN RLYTender No
SNT-JP-19-2024-25Tender Authority
North Western Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf 04 mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. 2V, 500AH
120
11251
1350204
... More
Refixing of electrical point machine, ground connection during phase working (Non interlocked working) after removing the existing fitting if any, adjustment if necessary, cable 05 termination, wiring , testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on NWR & the instruction of Railway Engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution.(the unit is Per turn-out)
30
2567
77026.5
... More
Supply of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome 06 plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the agles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
200
1778
355680
... More
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP 07 stumps ) with contractor's fixing material .This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution.
200
1315
263128
... More
Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply.
2000
5
11380
... More
Supply of GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply.
500
66
33005
... More
Supply of Panel cum Block Instrument table complete as per approved drawing . It includes any modification to it if required by Engineer-in-charge at site. Inspection: Consignee Inspection Charges:None Payment Terms: 100% after Supply.
10
34560
345606.8
... More
Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 11 operating temperature (-30) ° to (50) ° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply.
200
5301
1060340
... More
Horizontal Drilling by using manual pushing method at minimum depth of 1.5 meter 12 below the formation level of earth as per decision of Engineer in charge .Pipe Supply is not covered under this item Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution
1000
122
122740
... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 13 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter)
500
274
137140
... More
Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground can not be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small.In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter)
500
503
251520
... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on 15 each cable to give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution(unit is RM running meter)
2000
9
18200
... More
Supply of Earth Leakage Detector (ELD) 12 Channels as per RDSO Specn.RDSO/SPN/256/2002 or latest. Inspection: RDSO Inspection Charges:Borne by Railways Payment Terms: 100% after Supply.
8
158443
1267545.76
... More
Wiring, installation, testing and commissioning of Earth Leakage Detector (ELD) 12 17 Channels as per RDSO Specn.RDSO/SPN/256/2002 or latest. This includes supply of fuse terminal strip for incoming power supply wires. On job training at site will be given by OEM engineer for installation and maintenance of ELD. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning.
8
39610
316886.48
... More
Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance 18 measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 - 49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement Model - DECT-2 or equivalent / higher version make Motwane/Stanlay/Fluke/Megger. Inspection: Consignee Inspection Charges:None Payment Terms: 100% after Supply.
2
84854
169708.92
... More
Supplying and placing of one layer of standard size of B grade quality bricks of the 19 local make spreading on cables laid.(minimum size of brick 200mm X 100mm X 70mm) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Installation. Lengthwise (up to 2 cables).(Unit is per RM Running Meter)
200
14
2960
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%