Nathdwara Temple Board Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Nathdwara Temple Board Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 27,39,000 
Notes
Download

Costs

  • EMD

    ₹ 54,800
  • Document Cost

    ₹ 590
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)

300

235

70500

... More
Replacement of stone Chajja with sriwan in damaged portion as per existing thickness and width in CM 1 : 3 with removal of old damaged pieces of chajja including top plaster of chajja and bottom pointing in CM 1 : 3 with scoffolding upto Ground floor level as per direction of Engineer in charge

3.16

2820

8911.2

... More
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.

24.76

617

15276.92

... More
Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc.

53.2

220

11704

... More
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 4 (1 cement : 4 coarse sand)

8.68

5196

45106.48

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 25 mm thick.

491.53

227

111576.18

... More
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats)

791.53

84

66488.1

... More
White washing with lime to give an even shade including all scaffolding:New work (three or more coats).

2192.89

11

24121.83

... More
Painting with enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

607.02

69

41884.66

... More
Providing and fixing steel gate grating and grills made of angles, tees, square bars or flats black pipe with holdfast and fittings complete as per deign and drawing including cutting welding and fabrication with priming coat of red oxide.

129.2

96

12403.2

... More
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)

98.13

364

35717.5

... More
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)

30

394

11820

... More
Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge Prelaminated particle board with decorative lamination on both sides.

9.49

1092

10360.9

... More
Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)

7.18

1977

14184.98

... More
S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding.

10.18

925

9411.88

... More
Providing and fixing M.S. sheet single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally bracked with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engineer-in-charge but excluding cost of chowkhats: including two coats of anti-corrosive red oxide primer paint.M.S. Sheet 18 S.W.G.

25.16

2869

72184.04

... More
Add extra for double leaf shutters

25.16

573

14436.81

... More
Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick.

28.79

609

17531.89

... More
Providing and fixing fully panelled /partly panelled double leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure „A‟ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces :35 mm thick Ivory coast wood grade I

2.62

2976

7797.12

... More
Providing and fixing fully panelled/partly panelled/ double leaf shutter frames for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :35 mm thick Ivory coast wood grade I

12.08

3345

40407.6

... More
Supplying & fixing door, window, chowkhats and frames, including antitermite treatment M.S.flat , hold fasts of size 250x40x3 mm fixed with M.S. bolt 5 mm dia 50 mm long duly embedded in cement concrete M-15 grade. Ivory coast wood Grade I

0.14

135533

18568.02

... More
Providing and fixing T-iron frames for doors windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs, 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

293

83

24319

... More
Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge

27.16

3895

105788.2

... More
Refebrication work with existing steel work including cutting, welding & refebrication as per requirement with fixing at site complete as per direction of Engineer In charge

100

34

3400

... More
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes.

300

100

30000

... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.0.63 mm thick with zinc coating not less than 275 gm/m2

15.35

645

9900.75

... More
Providing and installation of Poly Carbonate Sheet roofing over existing steel framing as per drawing and design including fixing with non-corrodible nuts and water proof washers as per instruction of Engineer-in-charge.10 mm thick

20.87

1914

39945.18

... More
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).

87.17

674

58749.21

... More
Extra for using size above 200x300mm in glazed tiles

87.17

67

5874.92

... More
P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mm

39.45

1183

46666.98

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:

3392.47

81

274790.07

... More
Anti termite treatment of floor using Imidacloprid 30.5% EC non repellent, odorless, low dose, environmentally safe terniticide with rapid action non corrosive stain free, by drilling 12mm diameter holes 300mm apart injecting the emulsion as per specification and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area DPE 12mm dia termitube system with required number of junction boxes are to be installed. The termitube will run all along the perimeter wall both inside and outside. In the middle area the termitube to be installed at an interval of 1.00 Mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. After successful testing of termitube,pesticide emulsion of imidacloprid 30.5% EC mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. The plinth area of the area treated will be measured for payment.

425.15

216

91832.4

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ).

2192.89

4

8771.58

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).

10

4624

46240

... More
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.110 mm dia

46.6

282

13141.2

... More
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Coupler (socket)110 mm dia

10

108

1080

... More
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87 .5 110mm dia

10

161

1610

... More
Providing and Fixing Cushion Vinyl/Fully flexible Vinyl Flooring confirming to I.S.-3462 Flooring of approved make with fibre base using rubber base adhesives including rolling with light wooden roller complete : 2.0 mm thick.

594.75

990

588803.49

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required. Short point (up to 3 mtr.)

10

359

3590

... More
Medium point (up to 6 mtr.)

5

578

2890

... More
Long point (up to 10 mtr..)

5

772

3860

... More
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. On board

5

357

1785

... More
Short point (up to 3 mtr.)

5

507

2535

... More
Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost of modular 16 amp. Switch and socket outlet , making connection , testing , etc. as required.

5

580

2900

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.Gr.-1 1 x 1.5 sq.mm

20

22

440

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

180

124

22320

... More
P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required.GROUP 1 Single pole MCB 6 A to 32 A rating

8

187

1496

... More
Four pole MCB 40 A 63 A rating

2

1745

3490

... More
Double pole MCB 6 A to 32 A rating

4

566

2264

... More
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 20 mm

40

40

1600

240

56

13440

... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp.  insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar,masking sheet,  making internal DB  terminations with copper lugs, Ferrules,  detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR4 Way (4+2)

1

1795

1795

... More
Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2.0 TR ISEER not less then 3.8

4

63731

254924

... More
Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)

160

1066

170560

... More
6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)

380

383

145540

... More
Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 20mm

450

189

85050



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.