Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of Certain E/m Sanctioned Works Under Ge (army) Suratgarh Mil Stn in Sri Ganganagar, Rajasthan, with an estimated contract value of Rs. 29,49,811. The bid opening date for this tender is 10-10-2018 and the last date for bid submission is 09-11-2018. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date10 Oct 2018
Closing Date9 Nov 2018
Tender Amount₹ 29,49,811 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .

13.7

-

-

... More
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.

221

-

-

... More
S&F sheet metal enclosure DB concealed with wall having facility to fix MCCB as incomer and MCBs in outgoing, TP vertical type 04 way of double door, complete fitted with bus bars, neutral links, G frame including 03 pole MCCB 32 Amp capacity 50 Hz, 10 KA breaking capacity GS frame type, blanking plates including making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. Make of DB :- Havells Cat part No DHDLVDRWGOFO04, and MCCB cat part No IHLGST0032 or equivalent in L&T / Schneider / Legrand

2

-

-

... More
S&F three phase automatic street light switch suitable for 5 KW load complete with two numbers Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is 30 Lux and for switching OFF 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a pole / wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge. Make :- Swadeep - 02EC5KW3P

6

-

-

... More
Supply, fixing and testing LED Street / Security light fitting of 60 Watt, 5700K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should  not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Havells Cat part No. ENDURAPEARLPLUSSL60WLED757PASYTOPC or equivalent in Syska / Crompton

80

-

-

... More
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multi stranded copper conductor 4Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.

55

-

-

... More
(B) Alternator :- Synchronous alternator of rating 40 KVA 3 phase 50 cycle 415 volts 4 wire AC supply 0.8 PF at NTP for running at 1500 RPM self excited, self regulated, screen protected, brushless type mounted on common base frame coupled with above Engine. The alternator shall be conforming to IS 60034-1 / BS 2613 suitable for tropical conditions and with class F/H insulation. Make of Alternator :- Kirloskar / Cummins / Alstom / Stamford (C) Contol Panel & AMF Panel :- Control panel and AMF panel 415 Volts 3 phase, 4 wire 50 cycles fabricated out of 2mm thick MS sheet and powder coated painted internally and externally complete with copper bus bars with suitable capacity with incoming / outgoing terminals control wiring with copper cable of suitable size for 40 KVA DG set including all engine and alternator control switches and indicator as per manufacturer design and comprising of the followings :- (a) MCCBs of 63 Amps capacity 415 Volts 4 pole 16 KA for incoming/outgoing with over load and short circuit protections -03 Nos (b) Voltmeter and Ammeter with selector switches and CTs of suitable capacity. (c) Power factor and frequency, RPM, running hours counter, water tempreture, lub oil pressure meters. (d) Indicating lamps (LED type) to indicate RYB and for load on and set running, battery charger ON (e) Failure indication (LED type) over / under speed, fail to start. low oil pressure, battery charger failure. (f) Engine start and stop push buttons. (g) Battery charging indicator lamp – 01 No (h) Instrument fuses and control wiring – 01 set (j) Auto / Manual test switch – 01 No (k) Under Voltage relay – 01 No (l) Digital electronic multification metre (Timer) – 01 No (m) over load relay (n) By pass arrangement with rotary by pass switch AC 4 pole suitable Amp rating to isolate AMF Panel (o) Four pole power contactor of suitable capacity - 3 Nos (p) Automatic Battery Charger - 01 No, SMPS based inbuilt, auto / manual & float / boost facility. (q) Microprocessor based power command control for DG set monitoring metering and control having protection of over current short circuit, high / low voltage, under / over frequency, reverse power, excitation protection, field failure relay, differential relay all as specified.

-

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 25mm x 4mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Note :- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position (iv) Minimum weight of reinforcement for RCC cover shall be 1 KG.

2

-

-

... More
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in L & T / Havells / Schneider

16

-

-

... More
Supplying, jointing and testing heat shrinkable type outdoor, end termination jointing kit, suitable for cable of size 70 to 240 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge

61

-

-

... More
S&F cable junction box of size not less then 225x295x122mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 66 / 67 for outdoor Installation with internallly embedded gasket (PUR) including the box fitted with connector 8 way 40 Amps 01 No incoming / outcoming cable at controlled with MCB SP 6 Amps 01 No & enclosed along pole with MS flat iron clamp of suitable size and including 40mm GI pipe light grade 60cm length for cable protection fixed along pole complete all as specified and directed by Engineer-in-Charge. Make :- Hensel Cat Part No KF 3500 G or equivalent in Legrand / Indokop Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.

53

-

-

... More
All as per item No 28 above but cable of cross sectional area 35 sq mm 3.5 core

750

-

-

... More
All as per item No 28 above but cable of cross sectional area 16 sq mm 4 core

260

-

-

... More
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in L & T / Havells / Schneider Make of MCB :- Legrand Cat Part No 408593 or equivalent in L & T / Havells / Schneider

4

-

-

... More
(D) Fuel Tank :- Fuel tank of suitable capacity as per manufacturer's instructions suitable to store for 12 hours running of DG set mounted inside accoustic enclosure and including all fuel connections lines with heavy duty MS pipe from fuel tank to DG set as per manufacturer designs. (E) Base frame & Installation – Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement, which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendation of manufacturer. (F) Exhaust system – Dry exhaust manifold with hospital exhausts silencer and catalytic converter. (G) Starting System – 12 volt DC starting comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable Nos of batteries (25 Plates, 180 Amp hour capacity lead acid type) as required as per specification. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, discharging hot air in to the atmosphere as per specifications.

-

-

-

... More
S&F 3 Port, RJ 45, CAT 6 Networking sockets with connector plug complete all as specified and directed by Engineer-in-charge.

22

-

-

... More
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.

1200

-

-

... More
M&L for point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated sheathed multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls for conduits and for sunken pressed steel terminal boxes and making good the disturbed surface with all jointing accessories including provision of pressed steel sunken terminal boxes 60mm deep, suitable length and 1.2mm thick painted with red oxide primer and making good disturbed surfaces of wall in CM 1:3 for mounting switches, sockets, covered with including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated sheathed multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one switch socket combination 15 Amp on independent board complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge

0.8999999999999999

-

-

... More
M & L for brick protection with old size sub class 'B' bricks laid flat, abutting each other with gap between adjacent bricks not exc. 10mm, length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.

1745

-

-

... More
All as per Srl item No 36 above but 15 mm dia bore.

326

-

-

... More
S&F category 6, four pair cable high speed, high performance, 100 OHM impedance cable capable of carrying high bit-rate signalling for extended distances in horizontal cabling with 20mm dia PVC Conduit including suitable size clamps, T, bend joints, etc and fixed to wall. Signal cable shall be comply with applications can include voice, ISDN , ATM 155 MBPS, ATM 622 MBPS 100 MBPS TPDDI, fast and Giga Ethenet, and IEEE 802.3/5/12, 100 base VG (100 base NE), 100 Base-T, 100 Mbps TP-PMD, 1000 Base-T, 10 GB complete all as specified and directed by Engineer-in-charge. Make :- Finolex / Havells / Polycab

250

-

-

... More
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, SSK

30

-

-

... More
Supply, installation, testing and commissioning of" Silent type" (accoustic enclosure type) Diesel Engine driven Generating set of capacity 40 KVA, 415 Volts 3 phase 4 wire 0.8 power factor and 1500 RPM at NTP electrical start, directly coupled and mounted on common base frame with coupling of suitable size to water cooled turbo charged diesel engine of suitable BHP as per IS: 10001/10002 and alternator as per IS-13364 complete with foundation, AVM pads, control panel fuel tank of suitable capacity with fuel lines of heavy duty MS pipe duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and suitable batteries of capacity of 12 volts 180 AH-01 No fixed on angle iron frame with necessary meters and sound proof canopy and separate battery charging system of suitable capacity with all standard accessories, tool box and tools as provided by the manufacturer including of the following : - Make of Gen Set :- Kirloskar / Cummins / Greaves Cotton (A) Prime Mover : Vertical diesel engine of suitable capacity water cooled (Radiator mounted close circuit as per BS 649 or IS 1002 direct injection type turbo charged. The DG set shall be capable of running 24 hours on full load. Engine shall be equipped with all standard fittings as per manufacturer's recommendation and mounted on common base frame with following :- (a) RPM cum Hour meter (b) Battery charging alternator with inbuilt regulator. (c) Ignition and starting keys with push button switch. (d) Lubricating oil pressure gauge, oil and water temperature gauges. (e) Batteries 12 volts 180 AH-01 No with battery leads of suitable size of copper cable. (f) Self starter motor of suitable capacity. (g) PCC Foundation for Generating set as per recommendation of Manufacturer. (h) Exhaust pipe duly insulated with asbestos rope for thermal insulation. (j) Exhaust silencer industrial type to maintain noise level. (k) Over speed indication (l) Low lubrication, oil trip indication (m) Engine Hours indication (n) Digital Amp meter & Voltmeter

1

-

-

... More
S&F Single phase automatic automatic street light switch suitable for 3 KW load complete with two numbers Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with one number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 01 No, outgoing MCBs single pole - 01 No of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is 30 Lux and for switching OFF 10 Lux. The sensor (one service & one stand by) should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a pole / wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge. Make :- Swadeep 02EC3KW1P

12

-

-

... More
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.

91

-

-

... More
All as per item No 28 above but cable of cross sectional area 50 sq mm 3.5 core

48

-

-

... More
M&L for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3.50m length buried directly and preferably vertically in ground with top edge not less than 0.25m below ground level, pipe surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by electric welding and connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 2 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engr-in-charge. Note:- (i) GI strip upto earth test point/equipment is included in this item. (ii) Minimum weight of reinforcement for RCC cover shall be 1 KG. (iii) Pipe electrode shall be tapered at the bottom and provide with 12mm holes (staggered) at 75mm centre to centre up to 2 meter height.

6

-

-

... More
S&F street light bracket made out of 40mm dia GI pipe light grade 1.50m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint complete all as specified and as directed by Engineer-in-charge.

58

-

-

... More
Supplying, jointing and testing heat shrinkable type outdoor, end termination jointing kit, suitable for cable of size 50 to 95 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
All as per serial item No. 9 here-in-above but depth exc 1.5 mtr & not exc 3mtr

1.3

-

-

... More
S & F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black colour in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.

29

-

-

... More
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..

141

-

-

... More
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.

277

-

-

... More
M&L for chemical earthing with one No of copper earth plate of size 900 x 600 x 5mm & copper earth strip 32x6mm buried in ground vertically to a depth not less than 3.60meter below ground level with top edge earth electrode at a depth not less than 2.50 meter deep below gorund level mixture should be filled 15 cm above top edge to earth plate including suitable quantity to backfill chemical compound for filling in each pit to cover earth electrode minimum 100 mm all around and electrode shall be jointed with copper strip of size 32 x 6mm by exhothermic weld complete with earth pit chamber of size 300 x 300mm and RCC cover for demarking the location of earth electrode complete all as specified and directed by Engr-in-charge. Make of back fill compound:- Tercel (Isogel) (Australia) / Indelec (Xgel) (France) / ERICO (GEM) (USA) / LPF (Reslo) (Australia) Note:- (i) The quuanitity of back fill compound and depth of earth pit can be increased by the contractor without any extra cost to Govt. The complete earth system shall be guaranteed to give result less than 1 OHM resistance. The testing of each earthing shall be carried out in presence of Engineer-in-Charge and test results shall be submitted duly signed by all concerned while claiming payments. (ii) Earth strip with protection pipe 50mm GI light grade upto 7.5 meter is deemed to be included in the rates quoted (iii) Earth pit shall be Constructed minimum 1.0 metre away from earth. (iv) Complete earthing will be redone at no extra cost of department , if result in not found below 1 OHM.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.