Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/maint Of Atc Power House, Relocation Of Ht Breakers And Ht Cables Including Making Duct, Repair To Floors Etc At Afs Jodhpur in Jodhpur, Rajasthan, with an estimated contract value of Rs. 40,00,000. The bid opening date for this tender is 06-06-2025 and the last date for bid submission is 10-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jun 2025
Closing Soon10 Jun 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L rendering 10 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finished fair and even complete all as specified & directed by Engineer-in-charge.

50

-

-

... More
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth (without using extra lime or cement) complete all as specified and directed.

100

-

-

... More
M&L Rendering 15mm thick in CM(1:4) on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engineer-in-Charge.

63

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of wall and applying two coat of white wash complete all as specified and as directed by Engineer-in-Charge.

100

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying two coat of white wash complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats exterior weather proof water base emulsion paint , over a coat of chalk whiting all as directed.

63

-

-

... More
M&L preparation of old decorated plastered or unplastered surfaces of walls and applying two coat of white wash complete all as specified & directed by Engineer -in-charge.

300

-

-

... More
M&L for preparation of old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper.

150

-

-

... More
M&L preparation of old decorated plastered or unplastered surfaces of ceiling and applying two coat of white wash complete all as specified & directed by Engineer -in-charge.

150

-

-

... More
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coat exterior weather proof water base emulsion paint all as specified and directed by Engineer-in-Charge.

1150

-

-

... More
M&L for preparation of old plastered or unplastered surfaces of walls and applying two coats exterior weather proof water base emulsion paint , over a coat of primer all as specified and directed.

620

-

-

... More
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.

100

-

-

... More
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.

20

-

-

... More
Demolition of reinforced cement concrete in ground floor and paving n.exc 15cm in thickness (below or above ground level) all as specified (reinforcement cut as required to facilitate demolition) .

1.37

-

-

... More
S&F mild steel chequered plates (Fe-290,Gde E-165), square cut or notched (ordinary and counter sunk) forming holes, without any attachment, fixing over cable trench in requisite dimension all as specified and directed by Engineer-in-Charge.

1695.6

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing the demolished material to a distance exc 250 m but not exceeding 500m and depositing where directed, complete all as directed by Engr-in-Charge.

66.88

-

-

... More
M&L for 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm stone aggregate as in sub base floor/floors and paving etc.

180

-

-

... More
S&F rubber moulded Machine pressed PCC interlocking paver block confirming to IS 15658-2006 of size 80 mm thickness M-40 Grade with grey cement and pigment laid dry over 25mm thick screed river washed sand cushion as in floor, shape and colour as directed by Engr in charge.

180

-

-

... More
M&L for Pre-cast cement concrete Type B1 1:2:4 (20 mm graded aggregate) kerb solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified

5

-

-

... More
M&L for preparation of new concrete surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of primer all as specified and as directed by Engineer-in-Charge.

18

-

-

... More
M&L 25mm thick PCC 1:2:4 type B-1 ( 20 mm graded stone aggre) as in sub base for tiles in floors .

214.99

-

-

... More
M&L, Hardcore of broken stone of gauge n exc 63mm deposited, spreaded & levelled in layers n exc 15cm thick watered and rammed to a true surface.

7.75

-

-

... More
M&L for PCC 1:4:8 type D-2(40mm graded aggregate) in foundation , sub base, filling and mass concrete complete all as specified.

17.3

-

-

... More
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over & including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.

150.01

-

-

... More
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 10 mm thick screed bed in cement mortor 1:4.

15

-

-

... More
Dismatling floor hearth or wall tiling including cement mortor bedding but not backing removing serviceable tiles to store and rubbish off the premise

400.52

-

-

... More
S&F coloured Glazed ceramic tiles in vertical surface 350x250mmx7mm 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortor 1:6.

333.54

-

-

... More
S&F, Non skid ceramic tiles coloured 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floor, set & jointed in neat cement slurry & pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6.

15

-

-

... More
S&F vitrified tiles 10mm thick (Square/rectangular) polishedin light shade, area n exc 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in cement mortor 1:6.

49.98

-

-

... More
S&F vitrified tiles 10mm thick (Square/rectangular) polished in light shade, area n exc 0.36 Sqm in skirting, dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick back coat of CM 1:4.

2

-

-

... More
Demolition of stone/ boulder masonry, built in cement/ lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed by the Engineer-in-Charge.

20.68

-

-

... More
M&L for Walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in in cement mortar 1:6, complete al as specified.

7.78

-

-

... More
M&L, Precast cement concrete solid bldg blocks exc 10 cm thick in PCC 1:3:6 type C-1 using 20mm graded stone aggr & set in CM 1:6 in walling.

12.9

-

-

... More
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor all as directed.

1

-

-

... More
M&L for 5cm thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete complete all as spd & directed.

10

-

-

... More
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified.

109.47

-

-

... More
S&F Anodised aluminium snap grid frame work (600mm X 600 mm) for false ceiling all as specified

109.47

-

-

... More
S&F 8 mm thick calcium silicate board if siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid for Exposed metal frame ceiling (Frame work for ceiling shall be measured and paid separately)

109.47

-

-

... More
M&L for preparation of new decorated plastered or unplastered surfaces of ceilling and applying two coat of oil bound distemper white or tinted over a coat of white putty in patches as required all as specified and as directed by Engineer-in-Charge.

109.47

-

-

... More
Dismantling chain link fencing of any description fixed to any type of fencing posts complete all as specified.

90

-

-

... More
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion Concrete, brick work, masonry, etc. and making good disturbed ground

40

-

-

... More
Excavation in post holes ( or similar holes) each n exc 0.5 cum each getting out, returning, filling in and ramming earth or broken rubble mixed with earh around , in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil.

20

-

-

... More
M&L PCC 1:4:8 type D-2(40mm graded aggregate) in foundation , sub base, filling and mass concrete.

3

-

-

... More
S&F angles in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0

243.6

-

-

... More
S&F, MS flat iron for securing the chain link fencing including necessary drilling for holes, cutting, punching, bending etc.

150

-

-

... More
S&F 5 to 10 mm dia Mild steel bolts (machine made) with hexagonal or square head at one end and screwed the other with washers and one hexagonal or square nut exc 10 cm long.

6

-

-

... More
Supply only 10 mm dia round bars in available lengths

74.04

-

-

... More
Supply only mild steel galavanized chain link fenciing of 3.15 mm dia of wire and 100mm x100mm mesh size including line wire straing bending binding etcall as directed

180

-

-

... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire

90

-

-

... More
M&L for broken stone boulders for loose filling with aggregates around transformer of gauge 20 to 63 mm all as specified and directed by Engineer-in-Charge.

16.2

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site.

2

-

-

... More
Supply & fixing factory made Solid PVC Door Frame of size 50mm x 90mm inculding polishing to door shutter matching complete all as specified & directed by the Engineer-in-Charge.

9

-

-

... More
Supply & fixing factory made solid prelaminted PVC moulded flush Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design wood grain on both sides complete all as specified & directed by the Engineer-in-Charge.

2.54

-

-

... More
S&F 150 mm extruded aluminium alloy handles ,fabricated type.

4

-

-

... More
S & F Aluminium anodised barrel tower bolt of extruded section 200mm long all as specified and directed by Engineer - in - Charge .

4

-

-

... More
S&F Butt hinges 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21

6

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site.

13

-

-

... More
S&F for Framed work 410-W (Gde E-250 )as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including hinges welding complete all as specified

155.91

-

-

... More
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified and directed.

25

-

-

... More
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed size of frame 125 x 60 mm

9

-

-

... More
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed size of frame 105 x 60 mm

9

-

-

... More
S&F 35mm thick glazed and skelton shutters open rebated and prepared to receive gauze etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred breds for securing glass etc sizes of members of shutters as specified in SSR Pt-I Sec 8 Clause 8.20(a) in 2nd class hard wood.

4

-

-

... More
S&F Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples.

3.2

-

-

... More
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specifed and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing Flush shutters,30mm thick solid core construction, with block board core and plywood face panels, both faces are covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.

6

-

-

... More
S&F 200mm mild steel barrel tower bolts, stove enamelled black with bright bolt & fixed.

10

-

-

... More
S & F 300mm mild steel sliding door bolts, clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.

5

-

-

... More
S & F mild steel butt hinges medium weight cold rolled ISI marked of size 100 mm complete all as specified and directed.

15

-

-

... More
S&F 150mm mild steel pressed handles oval type stove enamelled black.

10

-

-

... More
M&L two coats of synthetic enamel on wood (ordinary tint) over one coat of pink primer over 10cm width or girth incl preparation of new surface.

6.4

-

-

... More
S & F powder coated Aluminium anodised doors shutters of aluminium section weighing 0.55 Kg/m including necessary joining cleats glazing clip, ruber neoprane packing, aluminiun handle 02 Nos in shutter, suitable hinge 100 mm long, anodised aluminium snap beading, screw complete all as spd. & dierected

10.08

-

-

... More
Taking down steel window/ ventilator of any description and of any type with or without guard bars.

18.48

-

-

... More
S & F powder coated Aluminium anodised window and ventilators shutters side hung type without sash bars of aluminium section weighing 0.55 Kg/m including necessary joining cleats glazing clip, ruber neoprane packing, anodised aluminiun snap beading, screw anodised aluminium fitting such as peg stays 150mm long (01 Nos), hinge type B-21, 100 mm long (02Nos), suitable hadle and 100 mm long tower bolt, complete all as spd. & directed.

18.48

-

-

... More
S & F powder coated Aluminium anodised doors frame for doors, window/ventilators with one or more rebates including joining cleats for fixing complete complete all as spd. & dierected Engg. In. Charge.

79.2

-

-

... More
S & F 5.5mm thick sheet glass ordinary quality and glazing with oil putty in square exc. 0.5 sqm in each pane all as spd.

15.32

-

-

... More
M&L for aluminum grill mesh made out of 8x6mm girth n exc 75 mm both ways fixed with aluminum cleats to window frame

18.48

-

-

... More
S&F in repair door closer hydraulically regulated designation No-2 universal type of aluminium body fixed to door frames with screws or by welding complete all as specified and directed by Engr-in-charge.

4

-

-

... More
S&F in repairs brass mortice lock vertical type of size 100 mm

4

-

-

... More
S&F in repairs Vitreous China urinals, Half stall type, white), complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing with automatic sensor based urinal spreader for flushing with brackets, flush pipe, grating and Union for discharge pipe including PVC waste pipe, CP waste coupling, Sensor based urinal spreader complete all as specified and directed.

2

-

-

... More
Taking up or down steel tubing of 15 mm bore pipe and connection including cleaning for re-fixing or removal to store complete all as specified & directed by the Engineer-in-Charge.

25

-

-

... More
Taking up or down steel tubing of 20 mm bore pipe and connection including cleaning for re-fixing or removal to store complete all as specified & directed by the Engineer-in-Charge.

20

-

-

... More
Supply & fixing 15 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge.

25

-

-

... More
Supply & fixing 20 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge.

20

-

-

... More
Supply & fixing in repairs brass CP Bib taps, fancy type, 15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repairs EWC seat cover PVC colour as approved by GE including all fitting arrangements complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs of fancy type pillar taps brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe of 15mm bore complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs of brass Chromium plates angle Stop valves of 15mm bore screwed for 15mm bore iron pipe or union complete all as specified and directed.

5

-

-

... More
Supply and fixing in repairs brass chromium plated handspray (Health faucet) with flexible pipe length not less than 1.00 m (minimum) fixed for EWC/IWC suitable for 15mm bore pipe complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs of brass Chromium plates fancy type soap dish complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs chromium plated grating of size 100 mm dia complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs for 20 mm bore of Ball valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe (wt not less then for 210 gms) complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs of PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.

5

-

-

... More
Supply and fixing in repairs of vitreous china water closet (squatt pattern) complete including provision of lime concrete bedding fixed in repair of orissa pattern size 580x440mm, white, with and including foot rest (excluding flooring cistern & flush pipe) complete all as specified and directed.

2

-

-

... More
Supply and fixing in repair of vitreous china wash down water closet pan (pedestal pattern) white and trap including connection to drain flush pipe and anti syphonage pipe.

2

-

-

... More
Supply and fixing in repairs PVC valveless syphonic action type flushing cistern low level 10ltrs capicty white, fixed with new brackets complete all as specifed and directed Make.

5

-

-

... More
Supply and fixing in repairs of flush pipe of polythene of low or high density or PVC 32mm for low level cistern complete all as specified and directed.

5

-

-

... More
Supply and fixing in repairs of vitreous china WHB white flat back size 550mmx400mm on new brackets excluding taps waste china & plug including bracket etc complete all as specified and directed.

2

-

-

... More
S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers.

2

-

-

... More
S&F in repair 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as directed.

5

-

-

... More
Supply & fixing in repairs PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed by the Engineer-in-Charge.

25

-

-

... More
Supply & fixing PVC (SWR) pipe bends 110 mm dia provided with access door complete all as specified and directed by the Engineer-in-Charge.

8

-

-

... More
S&F 110 mm dia PVC (SWR) junction single,(Single T) equal or unequal all as directed.

1

-

-

... More
S&F 110 mm dia PVC (SWR) vent cowl all as directed.

1

-

-

... More
S&F in repair 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as directed.

15

-

-

... More
S&F 75 mm dia PVC (SWR) bend any radius with access door all as directed by Engr-in-Charge.

2

-

-

... More
S&F 75 mm dia PVC (SWR) junction single,(Single T) equal or unequal all as directed by Engr-in-Charge.

2

-

-

... More
Supply & fixing PVC (SWR), 75mm dia of floor trap, with grating including jointing with solvent cement inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.

4

-

-

... More
S&F in repairs 1000 ltr capacity rotational moulded polyethylere water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and with polythyne float and flynut complete.

2

-

-

... More
Demolition and breaking up 150 mm bore drain pipes, soil, waste and rain water pipes etc (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, in trenches or floors, including connections and fittings complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
Supply & fixing Reinforced Cement Concrete pipes 150mm dia, class NP2, laid & jointed complete with collars complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
Material & labour for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
Material & labour for construction in repair of new stone masonry soakage well 3.0 metres dia and 3.0 metres effective depth including soil work, in any type of soil,foundation in PCC 1:3:6 , wall of honey combed masonry with top ring M25 concrete including intercepting chamber and scdreen chamber made of brick masonry in CM 1:6 , RCC cover slab in M25 /SFRC cover, interconnecting pipes of RCC/DWC complete all as shown on drg No CEAA/TD/80 SHEET 1/2 & 2/2 and as specified & directed by the Engineer in Charge.

1

-

-

... More
Taking down/Shifting carefully VCB/RMU any capacity, any make, any type by dismantaling, dis-connecting HT sides, earthings of VCB/RMU , Shifting / transporting VCB/RMU carefully from the site to the other location within the Air Force Station, Jodhpur premises location and refixing at site with all electrical connection and testing and commissioning of the same to the entire satisfaction of Engineer -in- Charge.Note:testing /caliberation charges shall be paid in appropriated items here-in-after.

8

-

-

... More
Material & labour for shifting of existing DG Set 100 to 160 KVA from existing location to new location (within Air Force Station Jodhpur) including making of PCC platform as per OEM specification, disconnecting of all connection, re connection the cables, earthing, control wiring complete at new location, testing after connection etc inclding arrangement of all type of T&P, Vehicles etc complete all as specified & directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in repair cable joint kit for 11 KV grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.

12

-

-

... More
S&F in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.

11

-

-

... More
S&F in trench/wall / pole XLPE insulated PVC sheated armoured heavy duty HT electric cable with aluminium stranded conductor 11000 volt grade of sizes 95 Sqmm 3 Core complete all as specified and directed.

280

-

-

... More
S&F in repairs heat shrink right angled boots for XLPE 11 KV 95 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers.

11

-

-

... More
Material & labour for earthing complete with copper earthing electrode 60cmx60cmx 3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of 20x3mm, by means of nuts, bolts, check nuts and washer etc, made of copper and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore light grade GI protection pipe, test point etc. Complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately

8

-

-

... More
Material & labour in repairs bore earthing 150 mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia ,15cm C/C on both side of the pipe including lowering in bore well upto the depth of 49mtr and one metre above the ground level . The pipe electrode should be filled around commercial salt, charcoal dust , copper sulphate and magnisium phosphate of 30 cm layer each upto the full length of pipe. The bore well should have 12 metre of length 150mm dia MS pipe 4.8mm wall thickness for protection of bore well. Welding of GI strip 50x6 mm on earth electrode GI pipe 50mm dia upto the 10 metre below ground level and 15 metre from the bore well to test point gun metal and PCC foundation sorrounding the bore well 60x60x30 cm,complete all as specified and directed. Note :- If GI strip required more than 35 metres , than length exceeds 35metres shall be measured and paid separately.

2

-

-

... More
Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore light grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.

8

-

-

... More
M&L for Repair and maintanance of 11 KV HT RMU indoor/outdoor type, EACH WAY of RMU 400/630/800 Amp rating from HT Panel after switching off electric supply. Removal of all the possible mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, indication system, including checking the quality of insulating material, complete & refixing with faulty part replaced blowing out dust and applying the proper lubrication/ greasing and reassembling the including motorised operation and connection to HT panel & before filling of gas leakage testing carried out (if quantity is lesser than required) and make the RMU functional to the entire satisfaction and as directed by the Engineer-in-charge. Notes :- (i) The RMUs are installed at Tech area and salawas, RMU are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. (ii) CTC Solution,Spare parts if replaced & Gas if filled shall be measured and paid separately under respective items supply only .

4

-

-

... More
Material & labour for Repair,Maitainance & Servicing of 11KV HT VCB indoor/outdoor type complete including the following (a) Taking out 11KV HT VCB of 400/630/800 Amp rating trolley from HT Panel after switching off electric supply. Removing all mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, remote operation, indication system, upward-downward/in-out movement of HT VCB trolley,etc including opening the VCB trolly & checking the quality of insulating material,vaccum system complete. Replace defective parts, fixed/ moving contacts and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease and reassembling the VCB including connection to HT panel and make the VCB functional to the entire satisfaction of and as directed by the Engineer-in-charge. Notes :- (i) The VCBs are installed at Tech area and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc.

7

-

-

... More
Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 11KV VCB/RMU panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc. (iv) The VCBs/RMUs are installed at Tech area,salawas and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom,Schneider, Ashida, Siemens,L&T, C&S or any other of relays available on the site.

11

-

-

... More
Supply only indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed by Engr-in-charge.

24

-

-

... More
Supply only CTC solution bottle

6

-

-

... More
Supplying and laying Synthetic Rubber insulated mats 2.5mm thick for voltage Upto 11KV for electrical purpose as per IS15652-2006 (Superseding IS 5424) suitable for electric shock safety of sizes 2M X 1M.

8

-

-

... More
Supply only HT multimeter (Voltage, Amp, power factor, frequcncy.)

7

-

-

... More
M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and directed.

6

-

-

... More
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.

85

-

-

... More
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No drawn through and including PVC concealed conduit 20mm with accessories in wall floor etc ISI mark including sunken type metal boxes covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly , including making good of disturbed surface of cement plaster, whitewash/ distempered match with original colour complete all as specified and directed by Engineer-in-charge for Othe followings:- (a) one light/ fan/Exhaust fan point controlled by one switch regulator.

68

-

-

... More
(b) One 3 pin 5 amps socket outlet on indipendent board with other switchs.

8

-

-

... More
(c) All as per item No 135 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.

5

-

-

... More
(d) All as per item No 135 above but with 2.5 Sq mm copper conductor multistraned pvcinsulated and unshethed cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire. Make -Polycab/Havells/Filonex

4

-

-

... More
S&F in repairs switch piano 5 amps flush type single pole one way

81

-

-

... More
S&F in repairs switch piano 16 amps flush type single pole one way

4

-

-

... More
S&F in repairs socket outlet flush type 3 pin 5 amps

13

-

-

... More
S&F in repairs socket outlet 2 in 1, 3 pin 5 and 15 amps flush type

4

-

-

... More
S&F and testing in replacement including taking down existing DBs of factory made MCB DB SPN 8 way 240 volt with double door, IP - 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.

4

-

-

... More
S&F with replacement including unservicable MCB 6 to 32 Amps SP 10 KA 'C' Series

24

-

-

... More
S&F with replacement including unservicable MCB 40 to 63 Amps SPN 10 KA 'B' Series

4

-

-

... More
Supply and fixing in replacement ceiling rose polycarbonate ,isolated body 65 X 50 mm 2 to 3 terminal

55

-

-

... More
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.

35

-

-

... More
Supply & Fixing in replacement LED street light 100W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge

5

-

-

... More
Supply & fix in repairs Building Security light luminaire LED 22 W 600K,IP-65 with asthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI pipe light grade 1.5 m length fixed with MS clamp of suitable size grouted on wall with suitable nos of screws/bolts/nuts etc complete all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.