Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Special Repair To Lt Oh To Ug Cable And Its Connected Accessories At Various Location At Sri Ganganagar Mil Stn in Sri Ganganagar, Rajasthan, with an estimated contract value of Rs. 1,06,72,000. The bid opening date for this tender is 26-05-2025 and the last date for bid submission is 14-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date26 May 2025
Closing Date14 Jun 2025
Tender Amount₹ 1,06,72,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 25 sq mm 4 core complete all as specified.

2400

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 16 sq mm. 4 core complete all as specified.

2200

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 10 sq mm 4 core complete all as specified.

4000

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 10 sq mm. 2 core complete all as specified.

600

-

-

... More
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and not exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, complete all as specified.

2873

-

-

... More
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified.

2672

-

-

... More
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified.

201

-

-

... More
M & L for laying of DWC pipe of outer dia 110 mm complete all as specified.

3690

-

-

... More
M & L for laying of DWC pipe of outer dia 63 mm complete all as specified.

8280

-

-

... More
Supply and erecting factory made 7 m long hot dip galvanised octagonal pole with 130 mm dia including 1.5 Mtr single Arm HDG OD-48.3 at bottom and 70 mm dia at top A/F made up of 3mm thick HT sheet along with foundation type base plate of size 220X220X12 mm foundation bolt 4 nos of M20X750 high J type EN8 Grade with inbuilt junction box suitable for incoming 3 phase LT cable 16sqmm 4 core having 6A SP B class MCB fixed on bakelite sheet and stud type connector inside the pole, the pole shall be adequetly strengthened at the location of the door to compensate for the loss in section including excavation and RCC/PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufactures instructions including marking pole numbers in letters and figures of size radium tape not less than 10cm height with red colour enamel paint complete all as specified and as directed.

100

-

-

... More
Supply and errecting factory made 7 m long hot dip galvanised octagonal pole with 130 mm dia including 1.5 Mtr Double Arm HDG OD-48.3 at bottom and 70 mm dia at top A/F made up of 3mm thick HT sheet along with foundation type base plate of size 220X220X12 mm foundation bolt 4 nos of M20X750 high J type EN8 Grade with inbuilt junction box suitable for incoming 3 phase LT cable 16sqmm 4 core having 6A SP B class MCB fixed on bakelite sheet and stud type connector inside the pole, the pole shall be adequetly strengthened at the location of the door to compensate for the loss in section including excavation and RCC/PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufactures instructions including marking pole numbers in letters and figures of size with radium tape not less than 10cm height with red colour enamel paint complete all as specified and as directed.

40

-

-

... More
S & F in replacement, new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP67 roadway luminaire 60 watt with heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 50°C. (d) Power factor : Minimum 0.95. (e) THD : Max10%. (f) IP rating : Minimum IP 67 (g) IK rating : Minimum IK07. (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended). (l) CCT : 5700 K. (m) CRI : Morethan 70. (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver. (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) Note : Bracket for fixing and cable for connection shall be measured and paid separately

180

-

-

... More
Supply, install, testing and commisioning of Stainless Steel LT panel of suitable size outdoor cubical type factory made, weather & vermin proof made out of Stainless Steel sheet 3.15mm (outdoor type) thick through chemical treatment with 9 tank pre treatment process method for degreasing , derusting and phosphating powder coating with bottom frame made out of angle SS 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 250 Amps 6 way from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incoming proper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected iems complete. FP No 1 Incoming (i) Microprocessor MCCB 160 Amps, four pole with Adjustable overload short circuit ground fault, 415 V AC supply, having rupturing capacity 25 KA - 01 No Outgoing (ii) MCCB 63 Amps, Four pole with Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 16 KA - 3 Nos (iii) MCCB 40 Amps, Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 16 KA - 1 No. (iv) MCB TPN 25 Amp 10 KA -02 Nos (v) Indicating lamps set RYB - 01 Set (vI) Digital Amp Meter 0- 160 A with CT , Digital Voltmeter 0- 500 V

2

-

-

... More
Supply, install, testing and commisioning of Sainless Steel LT panel of suitable size outdoor cubical type factory made, weather & vermin proof made out of Stainless Steel sheet 3.15mm (outdoor type) thick through chemical treatment with 9 tank pre treatment process method for degreasing , derusting and phosphating powder coating with bottom frame made out of angle SS 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30 cm x 30 cm x 60 cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 160 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories& all connected items complete . Incomming (i) Mircroprocessor MCCB 100 Amps, four pole with Adjustable overload short circuit ground fault, 415 V AC supply, having rupturing capacity 25 KA -01 No Outgoing (ii) MCCB 40 Amps, Adjustable thermal and fixed magnetic release, 415 volts having rupturing capacity 16 KA - 03 No (ii) MCCB 4 pole 25 Amp 16 KA -02 No (iii) MCB SPN 25 Amp -01 Nos (iv) Indicating lamps set RYB - 01 Set (v) Digital Amp Meter 0- 100 A with CT , Digital Voltmeter 0- 500 V

4

-

-

... More
S&F on pole/wal/in panel, Stainless Steel Sheet enclosure Bus bar chamber consisting 04 pole 100 Amp 415 volts copper bus bar 4 way control with MCCB 100 Amp , Adjustable thermal and fixed magnetic release, 415 volts having rupturing capacity 25 KA -4 Pole -01 No as out going and incoming connecting cables of new/existing cables with suitable sizes aluminum thimbles.as per directed by Engr-in-Charge.

6

-

-

... More
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm dearth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm flat iron with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of Part I and connecting to earth test point all as specified or indicated including testing on completion.

6

-

-

... More
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4.0 mm size by means of bolts, nuts check nuts and washers earth lead protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) , GI light grade 20mm bore pipe for watering perforated at the bottom 7.5 meter long placed on top edge of earth plate common salt and charcoal filling test point , funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion.

30

-

-

... More
M & L for Boring of holes under road/pavement/hard standing or any other situation by manual mean and including passing GI pipe 80 mm bore and making good both the ends complete . Note : Pipe and cable will be measured and paid separately.

68

-

-

... More
Supply and fix GI pipe 80 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete.

28

-

-

... More
Supply and fix GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complte.

40

-

-

... More
S & F PVC insulated, PVC sheathed Copper conductor electric cable 1.5 Sq mm 3 Core 1100 volts grade for pole box to street light fitting.

1440

-

-

... More
S & F of Automatic Street Light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural Lux Level. Required Illuminance level for switching On is <= 30 Lux and for switching OFF >=10 Lux. The Circuit should be suitable enough to take Thre phase load of 12 KW with 3 nos Contactors, 3 nos incoming MCBs& 3 nos Outgoing MCBs of 32-40 Amps each & circuit wiring (Copper) of min 10 sqmm. complete all as specified and directed by Engineer-in-Charge. Make : Swadeep -66- 12 KW3P/ or equivalent in / Indo Asain/ Bajaj/L&T/C&S.

3

-

-

... More
M & L for repair of damange portions during laying of LT cable, including replant of existing arboriculture which disturbed during laying and repairs the same and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour, complete all as specified and direced by the Engineer-in-Charge.

900

-

-

... More
Dismanting of unserviceable ACSR conductor/AAC conductor of any size and any type complete all as specified.

27

-

-

... More
Dismanting of cross arm, clamps, bracing etc of MS section complete all as specified.

9

-

-

... More
Dismanting of insulator any type and size complete all as specified.

470

-

-

... More
Dismanting of old PCC Pole any type and size complete all as specified.

118

-

-

... More
Dismanting of GI bracket 1.2 Mtr long 40 mm dia complete all as specified and as directed.

158

-

-

... More
Taking out old street light fitting any wattage from existing pole and deposite to MES Store yard complete all as specified and as directed.

158

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.