The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/ Replacement Of Security Light/ Street Light, High Mast, Flood Light And Search Light In Domestic Area And Kaylana At Af Station Jodhpur in Jodhpur, Rajasthan, with an estimated contract value of Rs. 40,00,000. The bid opening date for this tender is 03-05-2025 and the last date for bid submission is 29-05-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 May 2025
Closing Date29 May 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down/out from trenches/wall/pole old unserviceable LT cable of size 2 Core x 10 Sqmm complete all as specified and directed.

350

-

-

... More
Taking down/out from trenches/wall/pole old unserviceable LT cable of size 3.5/4 Core x 16 to 35 Sqmm complete all as specified and directed.

450

-

-

... More
Supply, laying, connecting and testing of XLPE armoured LT UG cable 1100 volts grade of size 2 core x 10 Sqmm heavy duty aluminium stranded conductor with PVC insulated, including suitable sizes of aluminium lugs and gland packing complete all as directed and specified. Note:- Earth work, DWC pipe, GI pipe will be measured and paid separately.

350

-

-

... More
Supply, laying, connecting and testing of XLPE armoured LT UG cable 1100 volts grade of size 4 core x 16 Sqmm heavy duty aluminium stranded conductor with PVC insulated, including suitable sizes of aluminium lugs and gland packing complete all as directed and specified. Note:- Earth work, DWC pipe, GI pipe will be measured and paid separately.

450

-

-

... More
Taking down/ out LT UG cable of size 2 x 10 Sqmm to 3.5 x 25 Sqmm from trenches/ ducts/ wall for repair of cables and re-laying/ re-fixing in the same location including re-connecting and testing on load complete all as specified and directed. Note : Earth work, DWC pipe, protection pipe, joint kit, cable cover shall be measured and paid separately under respective items.

100

-

-

... More
Taking down/ out LT UG cable of size 3.5 x 35 to 95 Sqmm from trenches/ ducts/ wall for repair of cables and re-laying/ re-fixing in the same location including re-connecting and testing on load complete all as specified and directed. Note:- Earth work, DWC pipe, protection pipe, joint kit, cable cover shall be measured and paid separately under respective items.

100

-

-

... More
Supply and laying in repairs (HDPE) DWC pipe size 50 mm dia for LT cable protection including sockets, bends etc complete all as specified and directed by Engr-in-Charge.

350

-

-

... More
Supply and laying in repairs (HDPE) DWC pipe size 90 mm dia for LT cable protection including sockets, bends etc complete all as specified and directed by Engr-in-Charge.

105

-

-

... More
M&L in repairs for earthing complete with GI earth plate electrode 60 cm x 60cm x 6.0 mm thick and buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI earth plate with GI wire of size 04 mm dia by means of bolts, nuts and washers of steel all as shown in electrical plate No.3 including PCC pit (1:3:6) type C-1 in cement concrete, 40 mm thick precast RCC cover in (1:2:4) type B-1 reinforced with 8 mm dia MS round bar @ 75 c/c both ways with 01 No lifting handle of 12 mm dia MS plain bar, GI pipe 15 mm dia light grade for GI wire protection and GI tubing 20 mm, medium grade for watering including GI funnel with wire mesh etc complete all as specified and directed by Engineer-in-Charge. Note:- GI earth wire and earth protection pipe upto 7.5m lenth shall be included in the quoted rate.

10

-

-

... More
Supply, fixing & connecting in repair of FRLS PVC insulated twin core 2.5 Sqmm unsheathed multistranded copper conductor complete all as specified.

700

-

-

... More
Supply and fix in repairs on pole/wall PVC conduit super quality size 20 mm dia complete all as specified & directed by Engineer-in-Charge.

450

-

-

... More
Supply and fix in repairs of 6 sqmm 2 core, LT 1100 volts grade, PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc complete all as specified & directed.

600

-

-

... More
Material and labour in repairs for 40mm bore GI tubing light grade laid in trenches/fixed to poles, walls etc as protection of service cable all as specified of the following sizes.

50

-

-

... More
Material and labour in repairs for 50mm bore GI tubing light grade laid in trenches/fixed to poles, walls etc as protection of service cable all as specified of the following sizes.

60

-

-

... More
Supply & fixing in replacement of LED street light 70W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.

132

-

-

... More
Supply and fixing in replacement of LED street light 90W made up of pressure die-cast housing with epoxy powder coated dark graphite grey colour finish with IP 66 protection 230 Volt with all connected acessories all as specified and directed.

110

-

-

... More
Supply and fixing in replacement of LED street light 120W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.

75

-

-

... More
Supply & fixing in replacement of LED flood light 150W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.

48

-

-

... More
Supply & fixing in replacement of LED flood light 200W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.

40

-

-

... More
Supply and fixing in replacement of energy efficient integrated LED Solar street light fittings 40 Watts with inbuilt lithium battery of capacity 36 AH toughned glass having IP 66 protection, 230 volts lighting source with all connected accessories all as specified and directed.

50

-

-

... More
Supply and fix in repair GI pipe bracket bent to shape drilled welded made out of light grade 40 mm dia bore GI pipe 0.9 mtr long for fixing of street light fitting of any type and description including suitable size of MS clamps, nuts, bolts and washers including two coat of aluminium paint over one coat of primer complete all as specified and directed.

50

-

-

... More
Supply and fix in repair GI pipe bracket bent to shape drilled welded made out of light grade 32 mm dia bore GI pipe 0.9 mtr long for fixing of street light fitting of any type and description including suitable size of MS clamps, nuts, bolts and washers including two coat of aluminium paint over one coat of primer complete all as specified and directed.

50

-

-

... More
S&F in repair PVC cable Junction box for street light including 6 Amp MCB SP 'C' series with aluminium bus bar TPN for controlling the street lights complete with pole mounting type size 300 x 200 x 105mm with 02 Nos. MS clamp of MS flat iron with bolts, nuts and washer complete all fixed on poles/walls as directed by Engineer-in-Charge.

30

-

-

... More
Supply and fixing in repairs MCB DP 06 to 32 Amp, 'C' series complete all as specified and directed.

40

-

-

... More
Supply and fix in repairs MCB 04 pole 40 Amp, 'C' series complete all as specified and directed.

25

-

-

... More
M&L for painting of steel tubular LT poles of 9.0/11 mtrs with two coats of aluminium paint including painting to cross arms and clamps etc including preparation of surfaces by scrubing and cleaning with wire brush complete all as specified and directed.

250

-

-

... More
M&L for marking of pole serial number with black luminous words on luminous yellow round sticker as per sample complete as per directed & specified.

250

-

-

... More
Supply, fixing and testing in repairs of decorative LED post top lantern 40 watt with IP 65 protection complete all as specified and directed.

25

-

-

... More
Attending and fault detection of day to day street / security light (LED, MH/ SODIAM Flood light fittings etc. of any make) complaints received through telephone or in person and rectification of defects installed on Dispersal & High Mast light poles,Sun Shelter lights, Hanger light, perimeter light, watch tower light bringing down the fittings on ground or in position including cleaning of glass/ acrylic cover for clear reflection of light, jumper fixing, loose connection, GI bracket tightening, checking the connection of street light FRP junction box, light allignment, replacement of flexible wire, tightening of flood light safety chain in Hangers, Proper insulation of cannection (VMTL Vehicle, ladder, tools, LT tape and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. Note : (i)Light fitting,MH CHOKE,MH bulb, ignitor,driver,SPD if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply only. (ii) Contractor shall provide / deputed sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and reactified the same within 24 hours of receipt of complaints. (iii) Contractor manpower should attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Contractor will depposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M on daily basis on assesment of complaints. (v) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract.as directed by EIC.

1850

-

-

... More
Material & labour for attending of complaint of existing 12mtr long high mast light of any type, any wattage & any make, complaints received through telephone or in person and identification of defects, bringing down the system upto a normal heigt by manual/motorized mechanism & fixing at the same position after rectify the defect including flexible wire of required size, cleaning of light fittings for clear reflection of light, as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement). Note : - (i) Contractor shall be provide / depute sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and rectified/replacement of parts shall be measured and paid separately under supply only items. (ii) Contractor manpower shall attend daily to receive complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes.

6

-

-

... More
M&L for repair of mechanism of high mast and rewinding of three phase tower motor 440 Volt AC and including dismantling from high mast transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.

6

-

-

... More
Supply only electric driver 75 watt complete all as specified and directed.

100

-

-

... More
Supply only electric driver 90 watt complete all as specified and directed.

100

-

-

... More
Supply only electric driver 100 watt complete all as specified and directed.

70

-

-

... More
Supply only electric driver 150 watt complete all as specified and directed.

48

-

-

... More
Supply only surge protection device rated 5kv for LED type fitting complete all as specified and directed.

218

-

-

... More
Supply & fixing in repair of automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FF grade SMC junction box (sintex make) confirming to IP 54 suitable for three phase of 12KW model -Swadeep -02EC12kW3P of make -Nature switch or equivalent in legrand/siemens as approved by GE.

4

-

-

... More
Supply and fixing in repair modular power contactor type MNX 9 of rating 9 Amp complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply and fixing in repair modular power contactor type MNX 12 of rating 12 Amp complete all as specified and directed by Engineer-in-Charge.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.