The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/ Replacement Of Mcb, Dbs, Internal Wiring, Loose Electrical Wiring And Fittigs And Associated Electrical Infrastructure Alongwith Connected Items At Af Stn Suratgarh in Sri Ganganagar, Rajasthan, with an estimated contract value of Rs. 1,45,63,000. The bid opening date for this tender is 29-05-2025 and the last date for bid submission is 25-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 May 2025
Closing Date25 Jun 2025
Tender Amount₹ 1,45,63,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Srl item No 3.00 above but for one 5 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size, complete all as specified and directed.

61

-

-

... More
All as per Srl item No 3.00 above but for one 5 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size, complete all as specified and directed.

131

-

-

... More
All as per Srl item No 3.00 above but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor FRLS cable PVC insulated including earth wire 2.5 Sq mm copper conductor FRLS cable connected to earth dolly complete, all as specified and directed.

197

-

-

... More
Supply and fixing switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.

666

-

-

... More
Supply and fixing Socket outlet, flush type 2 in 1, 3 pin, 5 amps, 240 volts all as specified and as directed .

192

-

-

... More
Supply and fixing switch piano flush button single pole one way 15 amp 240 volts, all as specified and as directed.

601

-

-

... More
Supply and fixing Socket outlet 2 in 1, 3 pin, 5 and 15 amps, flush type, 240 volts all as specified and as directed.

197

-

-

... More
Supply and fixing of ceiling rose, surface type, 65mm x 50mm, 3 terminal complete all as specified and as directed by Engr-in-Charge.

737

-

-

... More
Supply and fixing of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed by Engr-in-Charge.

12

-

-

... More
Supply and fixing Fan step regulator, 120W 230 volts, 50 HZ, AC. Supply complete all as specified and as directed .

84

-

-

... More
Supply and fixing of LED bulb 10 watt, complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and directed by Engr-in-Charge.

174

-

-

... More
Supply and fixing in replacement of LED sleek mirror light fitting 10 watt provided with high output diffuser 2 feet, 230 Volts complete LED tube rod 10 watt with all accessories, pre wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge.

22

-

-

... More
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source 28 Watt with nominal system lumen output of 2800 lumens and a minimum system efficiancy of 100 lm/W. The luminarie shall have a rated system lifetime of 50,000 burning hours at L70. The luminarie should have a color temperature of 6500K and CRI > 70. The luminarie shall meet IP 66 rating and IK 09 rating with THD < 20% and PF >0.9 complete with all accessories as specefied and directed.

76

-

-

... More
Supply and fixing in replacement of LED Highbay 120 Watt suitable for Hangers / industrial application heat sink made of copper & equipped with fluid dynamic pressure technology ,lumen efficacy > 150 lm/w , CRI > 85% ,THD < 15% UL certified , driver equipped with double power embedded system, & automatic Power Shutdown and returning circuit embedded with Power supply, which turns off power against Fire, High Temperature, Over-voltage and Over-current. The luminarie should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, including taking down old unserviceable light fitting , complete all as specified and directed by Engineer-in-Charge. Note:- provision of necessery T & P like ladder/Boom Vehicle, tools etc as required for taking down and refixing of hanger light are deemed to be including in the quoted rate by the contractor.

159

-

-

... More
Taking down carefully high bay light any watt from Structure and carbon cleaning of fittings,cover,copper wire/aluminium wire,clamps ,nuts and bolts, mounting bracket and re assembling the same after testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of hanger light complete all as specefied.

43

-

-

... More
Supply and fixing in replacement of LED Flood light 120 Watt with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.

15

-

-

... More
Supply and fixing in replacement of LED Flood light 100 Watt with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.

108

-

-

... More
Taking down carefully flood light any watt from Structure and carbon cleaning of fittings,cover,copper wire/aluminium wire,clamps ,nuts and bolts, mounting bracket and re assembling the same after testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of hanger light complete all as specefied.

41

-

-

... More
Supply and fixing in replacement of LED building security light 30 watt, 230V with lens and toughen glass top.The luminarie should have a color temperature of 6500K, IP 66 complete PF > 0.95 with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and directed.

70

-

-

... More
Taking down carefully building security light any watt from Structure and carbon cleaning of fittings,cover,copper wire/aluminium wire,clamps ,nuts and bolts, mounting bracket and re assembling the same after testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of building light complete all as specefied.

22

-

-

... More
Taking down ceiling fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades deposit to store yard as it is in working condition for further hanging in its original position or any other position including as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service includes cleaning, greasing and oiling, painting of fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and as directed by Engr- in-charge. Note :- Any damage has to be made good by the contractor to make the item functional after testing.

84

-

-

... More
Taking down exhaust fans of any sweep and any size including cable connections and removing the exhaust fan with blades deposit to store yard as it is in working condition for further fixing in its original position or any other position as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service i.e. cleaning, greasing and oiling, painting of exhaust fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and as directed . Note :- Any damage has to be made good by the contractor to make the item functional after testing.

14

-

-

... More
Taking down Air circulation Fan of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades deposit to store yard as it is in working condition for further hanging in its original position or any other position including as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service includes cleaning, greasing and oiling, painting of fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and as directed by Engr- in-charge. Note :- Any damage has to be made good by the contractor to make the item functional after testing.

38

-

-

... More
Material and labour for in replacement of submain wiring with two single core 6.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6.0 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor.

9965

-

-

... More
Material and labour for in replacement of submain wiring with two single core 4.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 4.0 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor.

1292

-

-

... More
Material and labour for in replacement of submain wiring with two single core 4.0 sq mm PVC insulated FRLSH multistranded copper conductor cable drawing into and including stove enameled steel conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 4.0 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and steel conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick ,make good to existing surfaces are deemed to be including in the quoted rate by the contractor. (c) Necessery T & P like ladder/Boom Vehicle, tools ets as required for wiring of hanger light complete all as specefied.

4150

-

-

... More
Material and labour for in replacement of submain wiring with two single core 2.5 sq mm PVC insulated FRLSH multistranded copper conductor cable drawing into and including stove enameled steel conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 2.5 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and steel conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick ,make good to existing surfaces are deemed to be including in the quoted rate by the contractor. (c) Necessery T & P like ladder/Boom Vehicle, tools ets as required for wiring of hanger light complete all as specefied.

1620

-

-

... More
Supply and fixing in replacement of 4 core 4 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade laid in trenches/wall drawn through in PVC Conduit all as specified and directed.

415

-

-

... More
Supply and fixing in replacement of Steel conduit (25mmdia) inclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc.

415

-

-

... More
Supply and fixing in replacement of sheet metal enclosures single pole and neutral earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volts, complete all as specified and directed.

42

-

-

... More
Supply and fixing in replacement of sheet metal enclosures Triple pole and neutral earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 32 amps, 415 volts, complete all as specified and directed.

26

-

-

... More
Supply and fixing Sheet metal Vertical TPN double door DB 4 Way, 415 Volt, TPN with 200 Amps rated bus bar and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charg

214

-

-

... More
Supply and fixing Sheet metal TPN double door DB 4 Way, 415 Volt, TPN with 200 Amps rated bus bar and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charg

61

-

-

... More
Supply and fixing sheet metal enclosure for distribution board SPN (when MCBs to be used) 12 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge. .

266

-

-

... More
Supply and fixing sheet metal enclosure for distribution board SPN (when MCBs to be used) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge.

404

-

-

... More
Supply and fixing sheet metal enclosure for distribution board SPN (when MCBs to be used) 4 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge. Note (Ser No. 34 to 40) :- Cost for chieseling and cutting the wall for DB/sheet metal enclosure fixing, The disturbed surfaces of wall for DB shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for DB/sheet metal enclosure fixing shall be deemed to include the cost of making good.

74

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP, 6-32 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed .

6509

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN, 40-63 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed .

744

-

-

... More
Supply and fixing in replacement of MCB TPN four poles,40 to 100 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and as directed .

110

-

-

... More
Supply and fixing in replacement of MCCB four poles,100 Amps, breaking capacity 16 KA, confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc complete all as specified and as directed .

70

-

-

... More
Supply and fixing in replacement of MCCB four poles,125 Amps, breaking capacity 16 KA, confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc complete all as specified and as directed .

68

-

-

... More
Supply and repair in replacement of MCCB four poles,160 Amps, breaking capacity 16 KA, confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc complete all as specified and as directed .

27

-

-

... More
Material and labour for in replacement of earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.

275

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.