Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of Railway Underpass At Afs Uttarlai in Barmer, Rajasthan, with an estimated contract value of Rs. 3,37,34,000. The bid opening date for this tender is 30-09-2026 and the last date for bid submission is 01-12-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender - Rajasthan Tender
Opening Date30 Sep 2026
Closing Date1 Dec 2026
Tender Amount₹ 3,37,34,000
Costs
EMD
₹ 4,12,340Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Provn Of Railway Underpass At Afs Uttarlai
Description
provn of railway underpass at afs uttarlai (file no. 82370/e8)
Contact
Tender Id
2026_MES_791886_1Tender No
82370/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out for Demolition/Dismantling as listed in Sch 'A' Part III
1
49258
-
... More
Lump sum price worked out for Internal Electrification as listed in Sch 'A' Part IV
1
67562
-
... More
Lump sum price worked out for Internal Water Supply as listed in Sch 'A' Part V
1
11578
-
... More
Lump sum price worked out for Roads/Path/Hard Standing Paved Area/Culvert as listed in Sch 'A' Part VI
1
9790541
-
... More
Lump sum price worked out for Sewage Disposal as listed in Sch 'A' Part VII
1
473150
-
... More
Lump sum price worked out for Area Drainage as listed in Sch 'A' Part VIII
1
496178
-
... More
Lump sum price worked out for External Electric Supply as listed in Sch 'A' Part IX
1
3063346
-
... More
Lump sum price worked out for External Water Supply as listed in Sch 'A' Part X
1
266754
-
... More
Lump sum price worked out for Fencing, Gate & Boundary Wall as listed in Sch 'A' Part XI
1
994641
-
... More
Lump sum price worked out for Standby Power Supply as listed in Sch 'A' Part XII
1
13152
-
... More
Lump sum price worked out for Cooling Appliances as listed in Sch 'A' Part XIII
1
92331
-
... More
Lump sum price worked out for Automation of Gate as listed in Sch 'A' Part XIV
1
27524
-
... More
SCHEDULE 'A' PART - XV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
-
-
-
... More
Roads/Path/Hard Standing Paved Area/Culvert
-
-
-
... More
M&L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n.exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed.
362.5
-
-
... More
Sewage Disposal
-
-
-
... More
M&L for three layer LLDPE septic tank of 10 users designed to carry sewage and sullage water, excavation in any type of soil PCC 1:4:8 below foundation vent shaft etc complete with up flow filter including media complete all as specified & as directed.
1
-
-
... More
M&L Soakage well including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including interrupting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 mtr dia and 3.0 mtr effective depth complete all as specified & as directed.
1
-
-
... More
External Electric Supply
-
-
-
... More
Supply and lay for DWCPE (Double wall corrugated polyethylene) (SN8) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall bearing ISI marked with IS 14930 (Par-I &II) for protection of underground cables of followings size nominal outer dia & normal inner dia with all fittings laid in trenches/road/nallah or fixed along wall for cable protection complete all as specified and as directed.
-
-
-
... More
(a) Nominal outer dia 63 mm & nominal inner dia 50 mm dia
1170
-
-
... More
(b) Nominal outer dia 120 mm & nominal inner dia 103.50 mm dia
640
-
-
... More
(c) Nominal outer dia 160 mm & nominal inner dia 136 mm dia
1310
-
-
... More
Labour only for taking out serviceable HT UG cables of size 3 core 95 Sq mm from existing trench by excavation and earth work in any type of soil including and keeping aside for segregation of serviceable cable, PCC cover safe custody for reuse complete all as specified and directed.
50
-
-
... More
Labour only for relaying serviceable underground HT UG cable of size 3 core 95 Sq mm obtained from BOQ item No 19.00 here-in-before complete all as specified and as directed.
50
-
-
... More
S&F for Cable route indicator/marker made up of PCC block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900x300x100mm thick with DANGER/11KV CABLE/MES embossing on cable route indicator/marker including painting as per approved colour and buries in ground 45 Cm including necessary earth work (as required /order at site) complete all as specified and as directed.
36
-
-
... More
S&F for cable route indicator/marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900x300x100mm thick with DANGER/LT 433 VOLTS CABLE/MES or DANGER/MES” embossing on cable route indicator/marker including painting a per approved colour and buried in ground 45cm indicating necessary earth work (as required/ordered at site) complete all as specified and as directed.
54
-
-
... More
Supply, installation, Testing and commission of Outdoor type (IP54), Vacuum Circuit Breaker (VCB) 11KV, 630 Amps, 25KA-3 sec, IP-54 SF6 insulated, one side extensible, motorised vacuum circuit breaker & metering Panel Bus PT with Top LV, Battery & battery charger, Earth net switch & LIU (Configuration V+M), inside robotically welded stainless steel 304 (Non Ferrite one magnetic Grade) tank having min thickness 2.5 +/- 0.5 mm with IP67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of class 0.5 VCB should be provided with internal bus bar as well as earthing bus bars of electrolytic grade copper padlock provisions & complete with all accessories. The complete VCB must be type tested for internal arc 21KA for 1 sec with AFLR classification from Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site reparability features such as site replaceable bushing/coupling/mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediate VCB manufacture’s own make. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection complete all as specified and as directed. The unit shall include the following with all necessary standard fittings as required at site:-
Note : Make of VCB are given in Appendix ‘B’. Channel partner/System Integrator/Authourized Partner/Licence partner of make of VCB should not be accepted.
2
-
-
... More
(a) Vacuum Circuit breaker consists of following accessories:-
(i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Draw out Type with CT Shorting feature, Graphical LCD Display (ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. (iii) SF6 Gas pressure indicator on the gas tank. (iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operations. (v) CT shall be minimum 50-100/1A, 2.5VA, 5P10 - 3 Nos. for protection (vi) CT shall be minimum 50-100/1A, 2.5VA, Class 0.5 - 3 Nos. for metering (vii) Right angle boot to be provided in each module (viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set (ix) Bus VT shall be 11KV/V3/110V/V3, 20VA, Class 0.5 - 3 Nos. for metering (x) Auxiliary VT shall be 11KV/230, 500VA for AC supply input to Battery Charger.
-
-
-
... More
(xi) Capacitive voltage indication fixed type system as per IE. (xii) Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm, 11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. (xiii) Right angle boots (push on type) (xiv) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB. (xv) Necessary interlocking arrangement for safety and operations (xvi) One No. Operating Handle for Manual Operation and one no. manometer (xvii) Safety Interlocks shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (xviii) Above switchgear shall confirm to all relevant IEC/IS Standards.
-
-
-
... More
S&F for LED Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP65 protection security light fittings luminaries of capacity 70 watts with high power LEDs as light source and electric driver, 4kV in built and 10kV external surge protection with Top opening driver cover for easy maintenance with warranty option of 5year from date of installation with pre wired and necessary mounting arrangement and provision of 4Sqmm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all as specified and as directed.
41
-
-
... More
S&F for Security light junction box of size 205x255x112 mm for luminaries, weather proof made out of polycarbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole/wall mounting type comprising of MCB SP 10 Amps, fixed on pole with brackets and screws complete all as specified and as directed.
41
-
-
... More
Supply, install, testing and commissioning of 16 Mtr high mast shaft in two section suitable for 50 Mtr/Sec wind speed with head frame wind mounting arm/bracket, luminaries carriage suitable to install 08 Nos luminaries in symmetrical arrangement, supply of raising lowering system comprising double drum wind/pully assembly, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial, 3mm section thickness, top dia 150mm, bottom dia 360mm including single dome aviation obstruction LED light with electrical connections, 32 Amps standard feeder pillar panel & necessary fittings and RCC foundation work as specified/ as per height by OEM complete all as specified and as directed. Note : (i) Quoted rate are deemed to be inclusive of all material which are incorporating in RCC foundation, bolts, nuts, washers etc as per drawing designed by manufacture or mounting the High Mast & light fittings.
(ii) LED flood light luminaries shall be paid and measured separately.
2
-
-
... More
S&F for LED flood light luminaries suitable for high mast of capacity 200 watts, 230 Volts, AC outdoor type energy saving new generation environmental friendly long life versatile high performance with pressure die-cast housing, toughened glass, IP-66 protection and individual LEDs with secondary lens optics with IP66 ingress protection, 4KV in-built and 10 kv external surge protection device, efficacy 120lm/W with pre wired, warranty option of 5 year from date of installation and necessary provision of fixing arrangement with MS clamp, bolts and buts and electrical connection upto fittings terminal complete all as directed.
16
-
-
... More
M&L for LED Sign board of approx size 2.5 feet x 30 feet duly lettered "AIR FORCE STATION UTTARLAI" complete all as specified and as directed.
2
-
-
... More
M&L for traffic signal light including pole, lights, control box with suitable size of PVC insulated electrical copper cable and connected items duly operated from Guard Room complete all as specified and as directed.
2
-
-
... More
Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof, IP 65 protection made out CRCA sheet 3.15 mm thickness of suitable size accommodate accessories with front and back double door opening/ lockable by the key from both side and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC /Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate). All extension link/ inter connection shall be insulated with heat shrinkable colour coded sleeves to accommodate and including the following accessories:-.
Note : Rate of earthwork and PCC work etc are deemed to be inclusive in this items.
1
-
-
... More
IN COMMING:-
(a) Copper strip bus bar of 200 amps rated capacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydro graphic insulators with nuts & bolts at both ends = 04 Nos
(b) 4 pole MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.
(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three).
(d) Digital Multifunctional meter, flush mounting type with CT’s of ratio 630/5 and selector switch – 01 set.
-
-
-
... More
OUT GOING:-
(a) 4 pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 18 KA including all fixing accessories with both ends spreader links - 02 Nos.
(b) 4 pole MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 18 KA including all fixing accessories with both ends spreader links - 04 Nos.
(c) Multifunctional Digital type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No
(d) Power contractor 4 Pole, 63 Amps, 415 Volts, 50 Hz - 01 No
(e) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150 mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT panel -01 No.
-
-
-
... More
M&L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.
Note:- (i) Earthing is to be done in front of the Engr-in-Charge.
(ii) Test Results of earthing to be submitted by the contractor for all earthings.
(iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall be deposited 2000/- per earthing as security deposit for a period of Ten (10) Years.
(iv) Failing to maintain resistance of earthing less than 01.0 ohm, new earthing to be provided by the contractor without any extra cost.
(v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surrounding area complete.
18
-
-
... More
External Water Supply
-
-
-
... More
Supply, laying, jointing & testing of Ductile iron (DI) pipe, with spigot and socket ends, centrifugally cast class K-9, with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenched/over masonry pillar complete of size 100mm (4”) dia all as specified and as directed.
720
-
-
... More
M&L for ductile iron fittings for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc.) Tee pieces single branch. “Y” junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new position complete all as specified ad as directed.
300
-
-
... More
M&L for construction of Brick masonry Valve pit of following size, One brick thick wall in cment mortar 1:4 on 100mm thick PCC 1:4:8 (40 mm graded aggregate ) in foundation, rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0 mm thick MS sheet, Valve pit Cover, welded with 40x5mm Flat Iron Frame around including provision of Hinges, Handles and Locking Arrangement and 40x40x6mm Angle iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20 m graded aggregate) Block of size 230x200x100mm, applying two coats of Anti-corrosive Paint over a coat of red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary earth work in any type of Soil.
-
-
-
... More
(a) 750mmx750mmx900mm (internal size)
2
-
-
... More
(b) 450mm x 450mmx 700mm (internal size)
2
-
-
... More
Fencing, Gate & Boundary Wall
-
-
-
... More
Supply & fixing for MS pulley size more than 20cm dia with bearing shaft, nuts including making necessary arrangement for bottom of sliding door shutter complete all as specified & directed.
8
-
-
... More
Supply & fixing for MS pulley size less than 20cm dia with bearing shaft, nuts including making necessary arrangement for bottom of sliding door shutter complete all as specified & directed.
24
-
-
... More
Standby Power Supply
-
-
-
... More
Supply, install, testing and commissioning of Diesel Engine driven generating set of capacity 40 KVA, 3 Phase, 4 wire, 415 Volts, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for outdoor application/installation, integrated design thereby facilitating / easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board for latest norms/regulation and lowest exhaust emissions meets with new generation with CRDI STD of CPCB-IV+, ISO 8728/Noise pollution norms of MoEF & certified by ARAI, Pune with fuel tank, battery and standard accessories, acoustic enclosure, vibration pad, tools and spare, as provided by manufacturer, PCC foundation as per OEM all as specified and as directed with the following specifications:-
1
-
-
... More
(A) ENGINE :-
(a) Engine shall be Water cooled diesel engine of suitable capacity to match the 40 KVA, alternator under NTP conditions with prime rating as per ISO 8728, provision of 10% over load provision shall be available for intermittent periods bearing BIS marked with BS-5514/ISO 3046. The Engine shall consist of following
(i) Fly wheel
(ii) Close coupling
(iii) Cooling fan
(iv) Radiator with guard and water pump engine mounted
(v) Battery charging alternator
(vi) Air cleaner heavy duty dry type
(vii) Fuel injection pump (FIP)
(viii) Radiator fan (blower type) with guard
(ix) Precision governor
(x) Fuel filter
(xi) Lubricating oil filters (mounted)
(xii) 12 Volts self regulating alternator belt driven by engine
(xiii) Exhaust silencer heavy duty residential type
(xiv) Corrosion resister / scale inhibitor
(xv) Starter 12 Volts DC
(xvi) Lubricating oil cooler
(xvii) Lubricating oil pump (gear type)
(xviii) Exhaust piping as per manufacturer design.
-
-
-
... More
(B) BRUSHLESS ALTERNATOR :-
(i) Alternator coupled to engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation. Brush less alternator shall be bearing BIS marked with BS 5000 or bearing ISI marked with IS-4722.
(ii) Type :- Self excited self regulated with automatic voltage regulator
(iii) Rating:- 40 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition
(iv) Speed - 1500 RPM
(v) System - 415 Volts - 2.5% AC 3 phase 4 wire 50 Hz
(vi) Connection - 4 wire star connection
(vii) Enclosure - Screen projected drip proof
(viii) Ventilation - Self ventilated
(ix) Insulation - Insulation, Class H, IP-23
-
-
-
... More
(C) CONTROL PANEL :-
The Control Panel shall be manufactured with 14/16 guage CRCA sheet duly powder coated for a weather proof and long lasting finish. The Control Panel shall consist the following parts:-
(i) PSO 500 Controller:- Aluminium Bas Bars with suitable capacity with incoming/outgoing terminals - Indicating Lamps for "Load On" and "Set Running" - MCCB of suitable rating with overload and short circuit protections.
(ii) PS 0500: Genset Controller :- Control microprocessor based Generator set monitoring and control system. The control shall provide a simple operator interface to the Generator set, manual and remote start / stop control, shutdown fault indication and an LCD hour counter. The integration of all function into a single control system provides enhanced reliability performance compared to conventional generator set control system. The control shall be designed and tested to meet harsh environment in which gensets are typically applied.
Features, Functions, Protections:-
(i) 16 character x 2 line alphanumeric LCD display with LED backlight.
(ii) Operator interface
(iii) Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory.
(iv) Provide alternator data - Voltage (line to line and line to neutral voltage) - current (1 ph. or 3 ph.) - KVA (3ph and total)
(v) Provide Engine data - Starting battery voltage - Engine running hours - Engine Temp - Engine oil pressure.
(vi) Control includes provision for service adjustment and calibration of DG control functions - voltage, frequency selection configurable input and output set up - Meter calibration
-
-
-
... More
(vii) Engine Control :-
(a) Power start operates on 12 Volts DC Batteries
(b) Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also make up the control system from sleep mode.
(c) Engine Starting :- The control system supports automatic engine starting, primary and backup start disconnects are achieved by battery charging alternator feedback or main alternator output frequency.
(d) Controller provide configurable time delay of 0-30 sec to start after remote start signal and time delay of 0-60 secs prior to shutdown after stop signal.
(e) Sleep mode increase battery life. Configurable current setting from low to minimize current draw when genset is not working.
(vii) Engine Protective Functions includes :-
(a) High engine water temperature warning/ shutdown
(b) Low coolant temp warning
(c) Sensor failure indication
(d) Low and high battery voltage warning
(e) Weak battery warning
(f) Fail to start shut down
(g) Cranking lockout : Control will not allow the starter to engage or to crank the running engine
(h) Cyclic cranking: Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods.
-
-
-
... More
(D) Sub Base Fuel tank:-
14 SWG MS Sheet and capacity to hold diesel sufficient for running 08 hours at full load including following:-
(i) Level indicator on fuel tank
(ii) Drain Plug
(iii) Piping for fuel tank as per manufacturer design.
(iv) Fuel strainer
(v) Air vent. Fuel tank shall be mounted as per manufacturers instruction
(b) Battery : As provide by OEM
(E) Base Plate :-
Fabricated out of MS Channels ISMC of suitable size for fixing DG Set all as specified by the manufacturers (Necessary permission / certificate from Central State Pollution Control Board shall be accomplished with DG Set) CPCB-IV.
(F) Foundation:-
PCC Foundation not less than 2.45 mtr (L) x 1.10 mtr (B) and 0.3 mtr (H) above ground) to be provided or as per OEM recommendations complete all as specified and as directed.
-
-
-
... More
(G) AMF Panel :-
Indoor type AMF Panel made upto 2.0 mm thick CRCA sheet power coated complete including following:-
(i) Main switch gear 63 Amps 4 Pole 36 KA, 415Volts AC MCCB with rotary handle and suitable spreader links -01 Nos
(ii) Mains control gear 63 Amps 4 Pole, AC1 240 VAC contactor - 01 No
(iii) Mains metering with RYB indication LED with necessary internal wiring of suitable size and din type connector and terminal connectors
(iv) DG Switch gear 63 Amps 4 Pole, 36 KA, 415VAC MCCB with rotary handle and suitable spreader links - 01 Nos
(v) DG control gear- 63 Amps 4 Pole, AC 240VAC contactor - 01 Nos
(vi) DG metering with RYB indication LED with necessary internal wiring of suitable size and din type connector and terminal connectors
(vii) Common metering with RYB LED indication LED with necessary internal wiring of suitable size and din type connector and terminal connectors
(viii) Common controlling all as per OEM recommendations
(ix) AMF Controller to monitor and display the temperature of engine, water, level of coolant, diesel, power consumption on main power consumption on DG, RPM, Hz, mains ON, DG ON, etc
(x) Single phase preventer
(xi)Overload protection relays
(xii) Under volt, relay
(xiii) Suitable cabling from DG set to AMF
(xiv) Door opening on front and rear side complete.
Note:- The cost of above provisions shall deemed to be included in quoted rate.
-
-
-
... More
Cooling Appliances
-
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and as directed.
2
-
-
... More
Supply, installation and testing og heavy duty desert cooler of cooling capacity 5000 Cum per hour with heavy duty electric motor of 150 watt copper wound, 500 mm sweep metallic blade duly painted synthetic enamel paint fitted to body, 1400 RPM, three speed, 240 Volts, 50 Hz, made of PVC reinforced body construction with three side and top panel cabinet body of suitable size with front grill and directional grills of suitable size and bottom water tank of capacity minimum 60 Ltrs with submersible pump motor 40 watt single phase and suitable size PVC connection pipe, wood wool pad of proper thickness will be provided in each panel including ON/OFF switch, fan speed selector switch and 1.5 Sqmm 3 core copper flexible cable and plug top complete all as specified and as directed.
2
-
-
... More
Automation of Gate
-
-
-
... More
Supply, installation commissioning and testing of Automation operation system for Metal sliding gate door to cover opening 8 mtr x 3 mtr made of SHA with 02 Nos electric automated operation by using the drive system, remote control, warning lamp etc, bottom rail, column etc as required to be designed for electrical as well as manual operation, Width & hight as per drawing, In case of power failure, change over from electrical to manual operation, width & height as per drawings. In case of power failure, change over from electrical to manual operation is to be achived by shifting the idler gear into manual position and using the handle provided complete all as specified and shown in drawings and including the followings:- (a) Squirrel cage copper wound with highest energy efficient electric motor of capacity 0.25 HP suitable for door movement with manual clutch release mechanism, positive drive with inbuilt MS casted drive wheels fitted with sealed bearing - 01 nos per each door consisting of leaves (b) MS casted Non drive wheels in special MS housing fitted sealed bearing.
(c) Suitable electrical control Panel outdoor type (double door both side openable) made out of 3.15 mm thick CRCA sheet fitted with MCB TPN of 32 Amps Switch Relay with emergency stop function, Emergency stop switch one set for each driving leaf consisting of suitable relays, power & auxiliary contactors, over load and under voltage protections and single phase preventer phase sequence corrector including other necessary components reqd for both side opreation of door with limit switch to avoid over run etc.
(d) Each motor door to be provided with operator pendant for door open, close and emergency stop operator push button with 2.5 sqmm 4 core copper cable of suitable length for door operator electrical connections, 0.5 sqmm 8 core cable of suitable length for ON/ OFF pendant, 0.5 sqmm 4 core cable of suitable length for proximity sensors - 02 Nos per door.
2
-
-
... More
Note :- (i) Specially designed Gear Drive along with Integral Drive Wheels/ Clutch for Emergency Manual Operation in case of POWER FAILURE to be Incorporated with Conts, heavy duty Electric Motor IP-65 Protection to suit electric supply of 415 Volts, 3 phase, AC, 50 Hz with energy efficient rating having PF more than 0.95, robust construction. Master Door Panel & Slave Door Panel will be a set of 2 Master & 4 Slave
(ii) The electrical operation of each master panel shall be carried out from a control panel mounted at the extreme end of the door openings inside the hangar building.
(iii) Master panel shall be fitted with a pendant push button station. The pendant shall be mounted to the leading edge of the leaf on a cord about 2 meters long that allows the operator to move from side to side to see where the door is being driven. The pendent is hung up on a hood when not in use.
(iv) The buttons shall include engraved marking like “Move”, “Open Mode” (as required) and “Emergency STOP” buttons. The “Open”, “Close” and “Move” push buttons are the dead man’s type; the Emergency “STOP” button is a red mushroom-headed, “twist – to reset” type. In addition a “Power ON” indicator lamp shall be fitted.
(v) CONTROL PANEL SYSTEM:- Each Door Control Panel shall consist of DOL starters, drive contactors, motor protection, control fuse holder, fused and indication lamps interlock contactors, limit/proximity switches, warning lights/hooters, trailing/bunching cable/wiring on the door after the main incoming power junction box. The incoming and of each control panel will be of MCCB 415 Volts, 63 Amps, 10KA and Outgoing will be of MCCB 415 Volts, 32 Amps, 10KA.
vi) DOOR OPERATION SAFETY:- The following features shall be incorporated in the control system of the door:
-
-
-
... More
(a) The Control Panel shall be located as directed for easy operation and enable the operator to have a full view of the area during operation of the door.
(b) The OPEN & CLOSE Push Buttons are constant pressure (HOLD to RUN) and the EMERGENCY STOP Push Buttons is STAY PUT type and have to be twisted to release.
(c) Emergency limit switch shall be provided at the extreme limits of travel just before the mechanical buffers. These emergency limit switches shall totally cut-off the control/power supply to the system in case the doors over shoot their normal limits.
(d) Audio/ Visual Alarm:- Master door panel shall be provided with a Flash Light cum Hooter that shall start & continue to operate during the time door is in operation.
(e) Key operation:- An operation key switch shall be provided on each control panel to prevent unauthorized operation of the doors.
Note:- All wiring and panels (Pendants master panels and slave panels) should be , weather proof. All cables should run in suitable size MS conduit with all accessories and junction boxes and cost deemed included in the said items. All operating switches should be self illuminating/ back light for the working in night.
-
-
-
... More
Supply and laying for double wall corrugated (DWC) (SN-8) high density polythene pipes having corrugated on the outer wall and plain surface on the inner wall bearing ISI marked with IS14930 (Part-I &II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches/road/nallah or fixed along wall for cable protection complete all as specified & as directed.
110
-
-
... More
NOTE : Amount of credit of Rs. 9000.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 56 of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-