Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of Children Parks And Interlocking Path In The Aor Of Age B/r-i Under Ge (a) Suratgarh At Suratgarh Mil Stn in Sri Ganganagar, Rajasthan, with an estimated contract value of Rs. 47,56,000. The bid opening date for this tender is 30-10-2026 and the last date for bid submission is 20-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender - Rajasthan Tender
Opening Date30 Oct 2026
Closing Soon20 Nov 2026
Tender Amount₹ 47,56,000
Costs
EMD
₹ 95,120Document Cost
₹ 500Tender Fee
Refer Documents
Description
Provn Of Children Parks And Interlocking Path In The Aor Of Age B/r-i Under Ge (a) Suratgarh At Suratgarh Mil Stn
Contact
Tender Id
2026_MES_796032_1Tender No
GE(A)/SOG-TOKEN-63/2026-27Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF CHILDREN PARKS AND INTERLOCKING PATH IN THE AOR OF AGE B/R-I UNDER GE (A) SURATGARH AT SURATGARH MIL STN
BOQ Items
... More
M & L for surface dressing n exc 15 cm deep in soft and loose soil all complete all as specified and as directed by Engineer-in-Charge.
585
-
-
... More
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
600
-
-
... More
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in-Charge.
162
-
-
... More
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 3.00 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
0.54
-
-
... More
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth or brocken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed by Engineer-in-Charge.
99
-
-
... More
M&L PCC 1:3:6 type C1 (using 20mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed
12
-
-
... More
Returning, filling in, including spreading,levelling, watering and well ramming in layer not exe 25 cm complete all as specified and as directed by Engineer-in-Charge.
132.21
-
-
... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
130.92
-
-
... More
M&L for hardcore of broken bricks, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
23
-
-
... More
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, sub base filling and mass concrete complete all as specified and directed by Engineer-in-charge .
114.25
-
-
... More
M & L for PCC 100 mm thick (1:3:6) type C-2 using 40mm graded stone aggregate as in floor finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge
225
-
-
... More
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-charge
9
-
-
... More
M&L for cement concrete (1:3:6),type C-1, using 20mm graded stone aggregate as in coping, kneelers, apex stones, bed plates, kerb etc including necessary formwork or similar work complete all as specified and directed by Engineer-in-Charge.
1.8
-
-
... More
M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed by Engineer-in-Charge.
21.56
-
-
... More
M&L for reinforced cement concrete 1:1 ½:3 type A1 using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engineer-in -charge.
3.4
-
-
... More
M&L for providing reinforced cement concrete 1:1 ½:3 type A1 , using 20mm graded stone aggregate as in column, pillars, piers, posts and sturts complete all as specified and directed by Engineer-in-Charge.
1.7
-
-
... More
M&L for use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete flat complete all as specified and directed.
7
-
-
... More
M&L for Square, rectangular or polygonal use and waste of form work to sides pillars, posts, struts, pier, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed.
10
-
-
... More
M&L for preparation of newly plastered surface of walls & Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint havingV OC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over a coat of acrylic putty and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in-charge.
160
-
-
... More
M&L Brick work with fly ash bricks (old size) straight or curved on plan exc 6m mean radius built in CM 1:6 including demolition of existing brickwork or stone boulder masonary , built in cement mortar or cement lime mortar including all quonins , arches, pillarsetc, but excluding ashlar facing dressed stonework and precast concrete articles complete all as specified
55.72
-
-
... More
S&F Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
1776
-
-
... More
S&F MS TMT Bars of 10 mm dia and over,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer-in-charge..
300
-
-
... More
S&F MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders,cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer-in-charge.
150
-
-
... More
S&F MS screw bolt 11 to 15mm dia, length of bolt not exceeding 50mm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge.
25
-
-
... More
S&F mild steel round bars 10mm dia cut to length, bent to shape as required and fixed in fencing confirming to Fe 410-Wor Fe 290 complete all as specified and directed by Engineer-in-charge.
Note :- Supply only chain link fencing shall be measured and paid for separately under replace items of BOQ.
463
-
-
... More
Supply only mild steel galvanized chain link fencing any mesh and any size complete all as specified and directed by Engineer-in-charge.
Note:- (i) Flat iron, round bars, nut bolts and washer shall be measured and paid for separately. (ii)The payment shall be made to the contractor for actual weight ascertain by the BOO as odered by GE.
900
-
-
... More
Fixing only mild steel galvanized chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge.
Note :- Supply only chain link fencing shall be measured and paid for separately under replace items of BOQ.
525
-
-
... More
Supply, fabrication, and fixing in position Mild Steel (MS) Tree Guards of overall height 2.50 metres and 0.60 metre diameter, fabricated using 3 Nos. MS Angle legs of size 25 x 25 x 3 mm (length 2.50 m) and 3 Nos. circular hoops/rings of MS Flat of size 25 x 3 mm (0.60 m dia) , guarded with Galvanised Iron (GI) wire netting of mesh size 25 x 25 mm (height 1.80 m wrapped around the 0.60 m dia frame) made from 3 mm to 4 mm dia GI wire, electric arc welded securely at all intersections and joints including digging post holes in any type of soil, embedding the 3 angle legs properly in ground to required depth in Plain Cement Concrete (PCC 1:2:4 / M15 grade) bed blocks of appropriate size, refilling, surface preparation, applying one priming coat of red oxide zinc chrome primer, and two coats of synthetic enamel paint of approved color shade and pattern, complete all as specified and as directed by the Engineer-in-Charge.
65
-
-
... More
Preparation of new concrete surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint including priming paints complete all as specified and directed by Engineer-in-charge.
100
-
-
... More
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
106
-
-
... More
S&F mild steel framed work as in doors / gates / steel frames etc. of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering including necessary welding etc and fixing in position of quality Fe 290 (Gde E-165) complete including applying two coats of synthetic enamel paints over a coat of red oxide primer including dismantling of mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
Note : Cost of welding of butt hinges to the door frame deemed to included in quoted rate and butt hinges shall be measured & paid for “Supply only” separately under relevant item of this BOQ
480
-
-
... More
M&L mild steel framed work of Fe-290 (Gde E-165) as in grills/guard bars shouldered with steel windows/ventilators frames. Cooler stand, ladder, barred iron doors; ladders; framed balusters; walkways; railings; etc complete all as specified and directed by Engineer - in - Charge.
380
-
-
... More
M&L for providing and fixing stainless steel (Grade-304) railing made of hollow tubes, channels,plates etc including welding,grinding,buffing, polishing & making curvature (wherever required), fitting the same with necessary stainless steel nuts & bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts, decorative elements etc, of required size including making groove/drill with suitable fixing arrangement in RCC floor/staircase/brick wall complete all as specified and directed
300
-
-
... More
M&L for 18-20mm thick Granite slab of approved shade and colour as in cooking platforms, steps, jambs, pillars, window cills and the like etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) over & including 15mm thick screed bed (bedding layer) in CM (1:6) complete all as specified and directed by Engineer-in-charge.
Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
30
-
-
... More
S&F factory casted 60mm thick machine pressed precast concrete coloured designer polished (rubber moulded coloured interlocking tiles with glossy finish) interlocking paver blocks of grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and pigment with coloured top casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified and directed by Engineer-in-Charge.
Note :- Shape & Colour of pver blocks shall be as approved by GE.
960
-
-
... More
M&L for 15mm thick rendering in cement mortar (1:4) on brick walls/concrete surfaces mixed with water proofing compound 3% by weight of cement finished as per manufacturer’s instructions including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Note : - Water proofing compound shall be included in this items. Nothing extra shall be paid on this account.
161
-
-
... More
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.Make of Pipe: Dr Fixit/Fosroc/BASF .
29.82
-
-
... More
S&F Plastic dividing strips,1.5mm thick 38 mm width and inserted in position, conform to design for flooring complete all as specified and directed by Engineer-in-charge
90
-
-
... More
Supply and fixing in position Precast Reinforced Cement Concrete (RCC) Benches of length 1500 mm, seat width 0.30 m to 0.40 m, with ergonomically designed integrated backrest, fabricated using M20/M25 grade concrete and TMT reinforcement/wire fabric including fixing and embedding the bench legs rigidly in position over Plain Cement Concrete (PCC M15) bed blocks of appropriate size embedded below ground/pavement level , jointed in cement mortar 1:3 , surface preparation, applying one coat of approved exterior primer and two or more coats of premium synthetic enamel / 100% acrylic glossy finish paint of approved color shade, complete all as specified and as directed by the Engineer-in-Charge
10
-
-
... More
M&L for laying lawn selection No 1 Grass in matt finish in rows 5cm apart either direction including digging of lawn/ preperation of lawn area as required depth breaking of clods etc, mixing of vermi compost @ 3kg/Sqm and insecticides, mixing in all , levelling, watering and cutting and dressing till the grass form a thick lawn free from weeeds and fit for mowing complete all as specified and directed.
3067
-
-
... More
S& F Inermi hedge boundary plantation trees, 1 to 3 feet size of 1 year old, Digging pit of required size, filling with manure pesticides including removal of surplus soil yo a distance n exc 250 m complete all as specified and directed.
400
-
-
... More
Supply and Planting of following plants in poly bags of 0.25m to 0.30m height including digging holes 1.20m dia x 1.20m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in the ratio 3:1 (3 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge or manure of approved quality after reduction by 8%) manure 200 gm per plant, flooding with water and removal of surplus soil, with & including using suitable chemicals or pesticides of approved quality, as required and making ‘Thaola’ complete all as specified and as directed :-
Notes :-
(i) The contractor’s quoted rates shall be deemed to include for necessary excavation and earth work, necessary manure or sludge and antitermite treatment of soil including necessary chemicals etc.
(ii) The excavated earth if found suitable and approved by Engineer-in-charge shall be used for filling in the holes after planting of trees/plants. However, in case the excavated earth is not found suitable for refilling and not approved by Engineer-in-charge, contractor shall arrange suitable good earth from his own sources as approved by Engineer-in-charge and contractor's quoted rates shall be deemed to include for arranging and transporting of good earth including filling in the holes and nothing extra shall be admissible on this account.
-
-
-
... More
Bougainvilla (Plant height 2 to 3 ft)
40
-
-
... More
Techoma (Plant height 2 to 3 ft)
40
-
-
... More
Callindara (Plant height 2 to 3 ft)
10
-
-
... More
Cassia biflora (Plant height 2 to 3 ft)
20
-
-
... More
Bottle brush (Plant height 2 to 3 ft)
10
-
-
... More
Neem (Plant height 2 to 3 ft)
15
-
-
... More
Seesahm (Plant height 2 to 3 ft)
10
-
-
... More
Gulmohar (Plant height 2 to 3 ft)
10
-
-
... More
Amla (Plant height 2 to 3 ft)
10
-
-
... More
Neembu desi (Plant height 2 to 3 ft)
10
-
-
... More
Supply and fixing post top lantern LED type 20 watt 230 Volts AC outdoor type with decorative post top for 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by the Engineer-in-Charge Note:(i) Excavation, earth work shall be measured including this item. (ii) RCC M20 and steel for foundation shall be as per OEM recommendation and drawings which shall deemed to be included in quoted rates.
10
-
-
... More
Supply fixing and testing in replacement LED Street light fitting of 60 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 60 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including provision of connection for street light from pole box with 2.5 Sqmm PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked complete all as specified and directed by Engineer-in- charge.
12
-
-
... More
Supply and erecting factory made Octagonal Hot Rolled steel pole conform to IS-2062/ BSEN10025 with hot dipped galvanised finishing of 7mtr long including suitable size of bus bar and MCB SP 06Amp, 230 volts with mild steel base plate of 6mm thick grouted alongwith foundation by mean of 4 Nos M20 x 600 LG foundation bolts including single swan neck bracket complete all as specified and as directed.
Octagonal pole includes the following :-
(i) Supply, and fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates etc as required as manufacturers recommendations suitable for design life not less than 25 years.
(ii) Erection and commissioning of pole with the help of suitable equipments and wiring of luminaries with all all copper conductor, cable of suitable size & providing flexible steel conduit pipe of ¾"mm dia for protection of cable
(iii) Drawing, design and casting of suitable shallow foundation with RCC M-20 mix concrete for octagonal pole considering the safe bearing capacity of soil as 10 tonne/ Sqm at 2.00 metre depth duly approved by GE
(iv) Casting of suitable foundation with RCC M-20 mix concrete for pole as per manufacturers recommendations.
(v) Excavation , earth work shall be measured and paid seperately in respective item.
4
-
-
... More
Supply and erecting factory made Octagonal Hot Rolled steel pole conform to IS-2062/ BSEN10025 with hot dipped galvanised finishing of 7mtr long including suitable size of bus bar and MCB SP 06Amp, 230 volts with mild steel base plate of 6mm thick grouted alongwith foundation by mean of 4 Nos M20 x 600 LG foundation bolts including double swan neck bracket complete all as specified and as directed.
Octagonal pole includes the following :-
(i) Supply, and fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates etc as required as manufacturers recommendations suitable for design life not less than 25 years.
(ii) Erection and commissioning of pole with the help of suitable equipments and wiring of luminaries with all all copper conductor, cable of suitable size & providing flexible steel conduit pipe of ¾"mm dia for protection of cable
(iii) Drawing, design and casting of suitable shallow foundation with RCC M-20 mix concrete for octagonal pole considering the safe bearing capacity of soil as 10 tonne/ Sqm at 2.00 metre depth duly approved by GE
(iv) Casting of suitable foundation with RCC M-20 mix concrete for pole as per manufacturers recommendations.
(v) Excavation , earth work shall be measured and paid seperately in respective item.
4
-
-
... More
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 35 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge.
100
-
-
... More
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge.
300
-
-
... More
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge.
100
-
-
... More
Supply and fixing HDPE DWC Pipe inner dia 50mm and outer dia 63mm for laying of cable laid trenches complete all as specified and as directed by the Engineer-in-charge.
Make of DWC Pipe shall be approved by GE
450
-
-
... More
S&F in galvanized iron tubing,40 mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge.
Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ
50
-
-
... More
M&L as in replacement for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge.
Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber.
(iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
2
-
-
... More
Suppyling, installing, testing and commissioning factory made outdoor type bus bar chamber having MCCB 4 Pole, 415 Volts, 125 Amps of suitable size for operation on 415 volts, 3 phase, 4 wire, 50 Hz, outer shell made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 450 Amps aluminium bus bar fixed Horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 250Amps, 36KA MCCB including provision for taking out incoming and outgoing cables detachable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and as directed by Engineer-in-charge.
1
-
-
... More
Supply & fixing of DUAL Nature Switch Smart Timer based automatic Street Light Control Panel. The panel shall be suitable enough to take 3-phase load of 08 KW. The 02 Nos. Smart Timers should be maintenance-free in design and settings accessible via a Mobile Application (With Bluetooth Connectivity). The Mobile App should allow users to customize the ON & OFF timings based on Natural Light Lux level (Sensor) or Local Sunset / Sunrise (Astro) or Time or Combination of above options. The Mobile App should also have facility to set Input Voltage range. The 02 Smart Timers along with 16–20 Amps per phase 3-Pole Power Contactors and 03 Nos. Incoming–Outgoing MCBs SP 20 Amps with 6 Sqmm copper cable circuit wiring complete should be enclosed in Pole/Wall mountable Rust Proof, electric shock proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure (with HINGED LID) confirming to IP66 Class-2. The circuit should also have provision for Manual Operation (i.e. Sensor By-pass option & Controlling current phase section option at least from 2 phases) complete all as specified and directed by Engineer-in-Charge Make:Navdeep-66-8kW3P-DUAL or approved equivalent
1
-
-
... More
SCHEDULE ‘A’ SECTION-II
-
-
-
... More
M&L for maintenance of all Plants, Hedge, Grass, etc provided under Sch 'A Sec-I by weeding, hosing, saucer making once in every month (minimum) for plants /hedge, insect and pest management (as and when required), pruning dried branches once in every week (minimum), depositing the material at place as directed by Engineer-in-Charge and planting the new plants in place of dead plants of same species and height turning without any extra cost to the department including watering of Plants, Hedge grass using own arrangements, complete all as specified and as directed.
Note : Contractor shall be responsible for all necessary arrangements for collection and conveyance of water from MES water supply points/source located upto 10 KM from the site for watering of Plants, Hedge, Shrubbery and Grass. Necessary water tanker with tractor, water browser, PVC pipes, etc required for watering purpose shall be contractor’s responsibility and quoted rates of this item shall deemed to include this provision. Manure & pesticide required for maintenance of plant under this item shall be arranged by the contractor at his own cost and cost of the same shall be deemed to included in the rate quoted against this item
12
-
-