Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 89,960Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maint Of Street Lights Fittings, Pole Box, Lt Poles And Other Connected Items In Residential And Tech Area At Af Stn Nal
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_707997_1Tender No
GE (AF) NAL /T-17/2025-26Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SCHEDULE OF CREDIT, SCHEDULE A NOTES, SPECIAL CONDITIONS, PARTICULAR SPECIFICATIONS AND OTHER CONNECTED DOCUMENTS
BOQ Items
... More
Re-stretching the existing LT overhead line of any size 3 phase 4 wire system (phase, neutral and one GI wire) and and one GI wire including opening and re- connecting of jumpers, binding of conductor over the insulator properly with the help of binding wire and all conductors bracing with separator as required complete all as specified and directed.
Note:- Three phases, neutral & GI wire shall be measured as one unit(5 Runs).
400
100
-
... More
M & L for prepration of old painted steel tubular pole 9 metre height by scraping with steel wire brush and cleaning the rust of pole and cross arm and applying two coats of Aluminium paint over and including a coat of red oxide primer at 1.5 m height above PCC coping and painting red and white strips ( 30 cm width ) with synthetic enemel paint upto 1.5 m height above PCC coping, and writing the exhisting pole number with black paint in yellow circle of dia 150 mm , complete all as specified and as directed .
450
53
-
... More
Material and labour for painting with one coats of synthetic enamel paint on RCC pole from 1.5 mtr above the PCC coping and balance 1.5 m above PCC coping will be painted by synthetic enamel paint in alternatively black and white strips of 30 cm after scraping /removing the existing paint and the preparation of the surface of RCC LT pole. Existing pole Nos will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed..
60
53
-
... More
Trimming of tree branches on both sides of LT/ HT overhead line , using t&p complete all as specified and directed.
NOTE : (i) Length of conductor shaded by tree branches shall be assessed jointly by contractor and JE before cutting of branches.
(ii) Cutted branches shall be dumped inside MOD Land as decided by engg-in-charge .
(ii) Ladder required shall be arranged by contractor.
(iii) Before commencement of trimming work, electric shut down shall be got managed by the contractor and sufficient man power shall be deployed on the particular time so that the task given by the Engineer-in-Charge shall be completed well within the time allowed.
400
100
-
... More
Checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide, T-5, LED Lights, Post top, Trafic light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) other than those mentioned in item No 2 to 5 here-in-after either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete as directed.
1150
1
-
... More
Note for item No. 1.00 :-
(i) New parts shall be measured and paid separately under relevant item of this BOQ as 'Supply only'.
(ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.
(iii) Required screws, insulating tapes, internal wiring wire , gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above item including rectification of cable fault & over head fault by fault finding/identification.
-
-
-
... More
(iv) Contractor shall be paid only one time the labour charges quoted above in BOQ `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor shall attend the said job as and when ordered by Engineer-in-Charge (during working hours ) and replace the spare parts / fittings immediately without any delay.
(vi) Immediately, on acceptance of contract, material shall be brought by the contractor on priority basis after getting approved and attend the complaint on priority basis.
(vii) Site of work is scattered in Domestic and Technical area and the contractor shall consider this aspect while quoting the rates.
(viii) If the complaint is not rectified within 24 Hours than Rs 500/- per day per complaint will be imposed to contractor as a penality.
-
-
-
... More
Supply only 1.5 sqmm twin core PVC insulated and sheathed copper conductor multistrand cable for electric connection from overhead line / junction box to street light complete all as specified and as directed.
350
100
-
... More
Supply only LED constant current driver for 45W light fittings as per existing make complete all as specified and as directed.
120
53
-
... More
Supply only LED constant current driver for 60 W light fittings as per existing make complete all as specified and as directed
70
10
-
... More
Supply only LED constant current driver for 70/72 W light fittings as per existing make complete all as specified and as directed
90
11
-
... More
M&L for repair to street panel board indoor / outdoor type of any capacity having Incomming & out going MCBs, timer switch and power contactor by carrying out the following works:-
(i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by mechanichally. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing.
(iii) Replacement of Incoming / out going switches as per existing make & model.
(iv) Replacement of timer switch and cortractor as per existing make & model.
(v) Replacement of control wiring with suitable size as per existing copper wire
(vi) Making the locking arrangement functional including welding if required
(vii) making proper connections for out going / incoming cable by providing suitable thimble as required.
Note: MCBs, timer switch and contactor shall be measured and paid separatly as 'Supply only' against respective item of this BOQ( Srl item No. 14.01 to 14.07).
13
53
-
... More
Supply only following fixtures / fittings for replacement in LT Panel boards:-
-
-
-
... More
MCB, 10 KA, SP, 32A
15
11
-
... More
MCB, 10 KA, SP, 40A
8
10
-
... More
MCB, 10 KA, TPN 63A
11
22
-
... More
MCB, 10 KA, TPN 32A
6
-
-
... More
Astronomical timer switch 110/240 volts Make : Havells Cat No DHTKW01016 or equivalent in list of makes.
15
100
-
... More
Power contactor 60 Amp 4 pole 415 V 50 Hz with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no SS90910 or equivalent in list of makes.
8
53
-
... More
Power contactor 40 Amp 4 pole 415 V 50 Hz with front mounting auxiliary contacts 2 No+ 2 NC rating .
Make : L&T Cat no SS90721 or equivalent in list of makes.
8
-
-
... More
S & F as in repairs LED street light 90 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP-66 batter optics for uniform distribution having surge protection 10 KV, sealed driver , complete as directed by engineer-in-chareg.
Make : Crompton Cat Part No. TRP-411-90-57-SL-GL-NSG or equivalent in list of makes.
40
100
-
... More
S&F as in repairs LED street light 60 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP-66 batter optics for uniform distribution having surge protection 10 KV, sealed driver taking out existing unsv light with complete all as specified and directed.
Make : Crompton Cat Part No. TRP-409-60-57-SL-GL-NSG or equivalent in list of makes.
120
53
-
... More
S&F as in repairs LED street light 45 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP-66 batter optics for uniform distribution having surge protection 10 KV, sealed driver taking out existing unsv light with complete all as specified and directed.
Make : Crompton Cat Part No. TRP-409-45-57-SL-GL-NSG or equivalent in list of makes.
100
10
-
... More
S&F LED 150 W flood light fitting with lense, high luminous efficacy,protected to IP 66, toughened glass efficient high out put emitter LED for better distribution having surge protection 10 KV, sealed driver applicable for area lighting including electrical connection including taking out existing unsv light, complete as directed by engg-in-charge.
Make : Crompton Cat Part No. LFLN-150-CDL/60-M or equivalent make in list of makes.
20
11
-
... More
S&F Aviation light 2 x 10 watt fitting complete LED type doble with alternate flashing and dusk automatic control housing cast aluminium base with red diffuse lens , including taking out existing unsv light at roof of overhead water tanks etc complete all as specified and as directed .
2
10
-
... More
Dismantling, taking out existing old serviceable LT steel Poles 9 metre with street light complete with street light fittings, brackets carefully for use from its original position and shifting to new location with complete all as specified and directed.
15
22
-
... More
Erection only of old serviceable LT steel Poles 9 m long complete with streetlight of any type in truly vertical position with new MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, including 1:2:4 PCC for foundation and coping complete all as specified and as directed.
Note : Excavation incl 1:2:4 PCC for foundation etc in post hole in any type of strata and coping shall be included in the unit qouted rate and nothing extra shall be admissible on this account .
15
-
-
... More
S & F LED path way light fitting of 60 watt capacity . IP65 die cast Aluminium Post top lantern designed with long life LED engine & Electronic Driver, designed for glare free symmetrical light distribution. incluiding 4 KV SPD WITH IP-65 protection with potted driver suitable for fixing in steel pole including taking out existing light complete all as speciifed and directed.
10
100
-
... More
S & F aesthetically designed hot dipped galvanised mild steel step pole 3.5 mtr height with grey powder finish. Compatible for post top lantern with Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories, window cover is fitted with allen screws to the pole along with service cutout suitable for fixing of connectors,cutouts and MCBs including taking out existing unsv RCC Pole complete all as specified and directed.
Note : Excavation incl 1:2:4 PCC for foundation etc in post hole in any type of strata and coping shall be included in the unit qouted rate and nothing extra shall be admissible on this account ..
10
53
-
... More
Supply, install and errect in Swan Neck type steel tubular swaged welded poles single 9.0 mtr long complete with CI base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, Single swan neck, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-31, L. T. pole including fixing arrangement of street light with swan neck type pole painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, including taking out existing unsv RCC pole complete all as specified and directed.
Note : Excavation incl 1:2:4 PCC for foundation etc in post hole in any type of strata and coping shall be included in the unit qouted rate and nothing extra shall be admissible on this account .
20
-
-
... More
Supply, install and errect in true vertical position steel tubular swaged welded poles single 9.0 mtr long complete with MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-31, L.T pole including pole mounted bracket for fixing of street light 1.2 m long ,drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete including taking out existing unsv RCC pole complete all as specified and directed.
Note : Excavation incl 1:2:4 PCC for foundation etc in post hole in any type of strata and coping shall be included in the unit qouted rate and nothing extra shall be admissible on this account .
40
100
-
... More
Supply and fix LED bollard light 10W pressure die cast powder coated housing with PC diffuser efficient high output LED with IP 65 protection including necessary fixing arrangement with 1:2:4 PCC for foundation at site including taking out existing unsv light complete all as specified and as directed by Engineer-in-charge .
15
53
-
... More
Supply and fix LED post top lamp spherical/Oval shape with polycarbonate diffuser and IP 65 protection 40 W, LED warm including taking out existing unsv light with complete all as specified and as directed.
15
10
-
... More
Supply and fix decorative LED Wall light 10W pressure die cast powder coated housing with PC diffuser efficient high output LED with IP 65 protection including necessary fixing arrangement at wall including taking out existing unsv light with complete all as specified and as directed by Engineer-in-charge.
25
11
-
... More
Supply and fix in repair LED warm white light( temp 3000k) with extruded aluminium body and PC diffuser complete with inbuilt driver 1x20 watt including electrical connection, as directed by engg-in-charge.
50
10
-
... More
S & F as in repairs LED street light 120 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP-66 batter optics for uniform distribution having surge protection 10 KV, sealed driver, completion as directed by engg-in-charge.
Make : Crompton Cat Part No. TRP-411-120-HL2-GL-NSG or equivalent in list of makes.
20
22
-
... More
Dismantling and taking down by removing LT connection of unserviceable overhead line( ACSR Conductor, 05 Runs) complete all as specified and directed.
800
-
-
... More
Taking down the unsv XLPE Cable of size 25/16/10 Sq mm including disconnecting from the existing location with complete all as specified and directed. Note: Cost of labour for excavation for taking out unsv cable will be paid separetely in respective cable laying items.
300
100
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core.
400
100
-
... More
All as per srl item No 33 here in before size of XLPE cable 16 Sqmm, 4 Core
800
100
-
... More
All as per srl item No 33 here in before size of XLPE cable 10 Sqmm, 4 Core
400
53
-
... More
All as per srl item No 33 here in before size of XLPE cable 10 Sqmm, 2 Core
300
53
-
... More
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
346
100
-
... More
Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
190
100
-
... More
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
156
10
-
... More
Material and labour for tibba sand for filling in trenches 8 cm below the UG Cable and 15 cm above the underground cables and punning down for cushioning of cables etc, complete all as specified.
Note :- Punned thickness shall be measured for payment.
138
11
-
... More
S&F sub class B bricks old size having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
11.97
11
-
... More
Demolition of brick or stone masonary built in cement mortar incl all quoins, arches, pillar etc. complete all as specified & directed.
15
22
-
... More
M&L for cement concrete (1:2:4) type B1 with 20 mm graded stone aggregate for pole coping above PCC foundation ground level including form work and finishing to all exposed surfaces without using extra cement all as directed.
15
-
-
... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 40 mm dia suitable for 0.4 mpa working pressure and sealing the end of pipe complete all as specified and directed.
45
100
-
... More
M& L for GI pipe light grade 40 mm dia for cable protection on wall/under road etc including fittings including taking out existing unsv GI pipe with complete all as specified and directed
24
53
-
... More
S & F in repair Street light timer panel suitable for 40 KW load 3 ph with timer switch and contactor of suitable capacity enclosed in CRCA sheet enclosure. Suitable for outdoor installation with complete all as specified and directed.
2
-
-
... More
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with galvanised earth lead wire 4.0mm
dia as earthing lead connected by means of bolts, nuts, check nuts and washers etc all as shown in para no 4 the earthing test point all as specified and directd.The GI earthing wire to be protected by galvanised iron pipe 20 mm bore (medium grade) up to ground level and Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including taking out exhisting earthing materails, complete and necessary earth work all as specified and directed.
5
100
-
... More
M&L for bus bar chamber cubical inclined top out door type made out of 3 mm thick MS sheet of size minimum size 600 x 450 x 450 mm, MS angle section 35 x 35mm x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of bus bar chamber with one coat of red oxide primer and two coat of synthetic enamel grey paint including aluminum busbar fixed horizontally in chamber of capacity 400 Amps for phases and 400 amps neutral for incoming and out going.(The gap between each bus bar should be minimum 100mm ) The panel shall be suitable for 415 volts, 50 Hz, 3 phase 4 wire system (suitable for 01 incomer and 06 outgoing ) and shall have MCCB 250 Amp 4 pole 36 KA as incommer, including taking out existing unsv bus bar chamber of any size with complete all as specified and directed by Engineer-in-charge Note :- (i) Earth work,1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable
8
53
-
... More
Supply and installation, testing, commissioning Outdoor type feeder piller Box factory made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made CPRI Approved & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel grey paint including taking out existing panel complete all as specifed and directed and consisting of the following equipments:-
(i) MCCB, 4 pole , 35/36 KA , 250 Amps -01 Nos ( Incomming)
(ii) MCCB , 4 pole , 16 KA, 63 Amps -03 Nos (Out going)
(iii) MCCB , 4 pole , 36 KA, 160 Amps -03 Nos (Out going)
2
10
-
... More
(iv STREET light timer panel suitable for 10 KW load 3 phase with timer switch and contactor of suitable capacity-01Nos (Outgoing) (v) Digital voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (vi) Digital Ameter of size 96 x96 mm ( 0-150A) with built in selector switch
(vii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv)
(viii) Solid aluminium bus bar 400 Amp for 3 phase and neutral
(ix) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge Note :- (i) Earth work, 1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable (iii) The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
M & L for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 32X6 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning including taking out existing complete all as directed.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
4
11
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%