Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 79,920Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690581_1Tender No
CWE/HSR/ALW/57 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit
3.16
-
-
... More
Dismantling stay assembly complete all as specified and as directed. (Note: Demolition of concrete, etc. and excavation measured shall be measured and paid separately separately.)
5
-
-
... More
Dismantling concrete poles/ struts, any size, transporting to store and stacking or for schedule of credit
12
-
-
... More
Demolition of cement concrete (unreinforced) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed.
2
-
-
... More
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
3
-
-
... More
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
1
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 185 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
225
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 150 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
230
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
250
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
360
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
200
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
950
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
1150
-
-
... More
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
694
-
-
... More
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
208
-
-
... More
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
20500
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
401
-
-
... More
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
293
-
-
... More
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed.
150
-
-
... More
Supplying & laying in trenches, in road cutting and along pole 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
80
-
-
... More
M & L for cable route indicator made out of CI plate 100 dia, 8 mm thick, embossed with lettering "MES LT Cable", welded or bolted onto 35 mm X 35 mm X 6 mm angle iron, 500 mm long duly painted with anti-corrosive paint in brown colour & including necessary earthwork and excavation, embedded in PCC M15(Nominal Mix) using 20 nominal size graded crushed stone aggregate of size 400 mm X 400 mm X 300 mm complete all as specified and as directed.
45
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Accessories: (a) MCCB rated current(In): 250A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply - 1 No (b) MCB, four pole with three protected pole (TPN), C-type instantaneous tripping, Rated current 63 A-4 Nos (c) Digital voltmeter 0-500 V withs selector switch – 1 No (d) Digital ammeter 0-50 Amps with selector switch – 1 No (e) LED indicating lamps – 3 Nos (D) PCC platform of height 750 mm (450 mm above and 300 mm below ground level) constructed with M10 (Nominal Mix) concrete using 20 mm nominal size crushed stone aggregate shall be provided for placing LT Panel Board. The length and breadth of foundation shall be 300 mm more on all sides than the size of the panel. The panel shall be fixed with platform using adequate size and numbers of anchor bolts grouted PCC platform.
3
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Accessories: (a) MCCB rated current(In): 160A, ultimate short circuit breaking capacity (Icu):25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply - 1 No (b) MCB, four pole with three protected pole (TPN), C-type instantaneous tripping, Rated current 63 A-4 Nos (c) Digital voltmeter 0-500 V withs selector switch – 1 No (d) Digital ammeter 0-50 Amps with selector switch – 1 No (e) LED indicating lamps – 3 Nos (D) PCC platform of height 750 mm (450 mm above and 300 mm below ground level) constructed with M10 (Nominal Mix) concrete using 20 mm nominal size crushed stone aggregate shall be provided for placing LT Panel Board. The length and breadth of foundation shall be 300 mm more on all sides than the size of the panel. The panel shall be fixed with platform using adequate size and numbers of anchor bolts grouted PCC platform.
5
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Accessories: (a) MCCB rated current(In): 160A, ultimate short circuit breaking capacity (Icu):25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply - 1 No (b) MCB, four pole with three protected pole (TPN), C-type instantaneous tripping, Rated current 63 A-5 Nos (c) Digital voltmeter 0-500 V withs selector switch – 1 No (d) Digital ammeter 0-50 Amps with selector switch – 1 No (e) LED indicating lamps – 3 Nos (D) PCC platform of height 750 mm (450 mm above and 300 mm below ground level) constructed with M10 (Nominal Mix) concrete using 20 mm nominal size crushed stone aggregate shall be provided for placing LT Panel Board. The length and breadth of foundation shall be 300 mm more on all sides than the size of the panel. The panel shall be fixed with platform using adequate size and numbers of anchor bolts grouted PCC platform.
5
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Accessories: (a) MCCB rated current(In): 100A, ultimate short circuit breaking capacity (Icu):25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply - 1 No (b) MCB, four pole with three protected pole (TPN), C-type instantaneous tripping, Rated current 63 A-5 Nos (c) Digital voltmeter 0-500 V withs selector switch – 1 No (d) Digital ammeter 0-50 Amps with selector switch – 1 No (e) LED indicating lamps – 3 Nos (D) PCC platform of height 750 mm (450 mm above and 300 mm below ground level) constructed with M10 (Nominal Mix) concrete using 20 mm nominal size crushed stone aggregate shall be provided for placing LT Panel Board. The length and breadth of foundation shall be 300 mm more on all sides than the size of the panel. The panel shall be fixed with platform using adequate size and numbers of anchor bolts grouted PCC platform.
7
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 200 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Accessories: (a) MCCB rated current(In): 100A, ultimate short circuit breaking capacity (Icu):25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply - 1 No (b) MCB, four pole with three protected pole (TPN), C-type instantaneous tripping, Rated current 63 A-4 Nos (c) Digital voltmeter 0-500 V withs selector switch – 1 No (d) Digital ammeter 0-50 Amps with selector switch – 1 No (e) LED indicating lamps – 3 Nos (f) Space and MCB channel for 20 Nos MCB SPN (D) PCC platform of height 750 mm (450 mm above and 300 mm below ground level) constructed with M10 (Nominal Mix) concrete using 20 mm nominal size crushed stone aggregate shall be provided for placing LT Panel Board. The length and breadth of foundation shall be 300 mm more on all sides than the size of the panel. The panel shall be fixed with platform using adequate size and numbers of anchor bolts grouted PCC platform.
6
-
-
... More
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
11
-
-
... More
S & F MCCB rated current(In): 63A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply complete all as specified and as directed.
11
-
-
... More
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
44
-
-
... More
S & F streetlight control box, SMC (Sheet moulding compound) body, moulded one piece, locking arrangement, of suitable size, IP65 protection including 1 No MCB SPN 6 Amps, 10 kA, 240 Volts, 4 Nos aluminium busbar of rating 100 Amps for triple phase and neutral connection, requisite porcelain insulators, fixing clamps etc. and fixing to poles including necessary wiring complete all as specified and as directed.
15
-
-
... More
S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for street light fittings (from feeder pillar/ junction box to street light fittings) complete all as specified and as directed.
90
-
-
... More
Supplying & fixing 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 fixed to electric pole with 20 mm X 3 mm galvanised iron clamps at 1 metre spacing complete all as specified and as directed.
105
-
-
... More
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts complete all as specified and as directed.
15
-
-
... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
20
-
-
... More
Dismantling of interlocking paver block and keep aside paver block for reuse complete all as specified and as directed.
225
-
-
... More
Providing and laying cement concrete paver block using paver block obtained in dismantling, laid in and including 30 mm thick compacted bed of coarse sand having gradation as per IRC SP 63: 2018 and 2 to 4 mm wide joints filled with fine sand having gradation as per IRC SP 63: 2018, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
225
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%