Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/maint Of Ht 33/11 Kv Oh Line/ Ug Cable, Ht Vcbs, Rmus And Transformers Installed At Domestic Area And Site 1a And 1b At Afs Jodhpur in Jodhpur, Rajasthan, with an estimated contract value of Rs. 70,00,000. The bid opening date for this tender is 20-05-2025 and the last date for bid submission is 17-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 May 2025
Closing Date17 Jun 2025
Tender Amount₹ 70,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material & labour for Repair and maitainance of 33 KV VCB outdoor type complete including the following (a) 33KV HT VCB of 1250 Amp rating HT Panel after switching off electric supply. Removing all mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, remote operation, indication system of HT VCB ,etc complete.Refixing with faulty part replaced, fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing with AP-3 grease and reassembling the VCB including connection to HT panel & and make the VCB functional to the entire satisfaction of and as directed by the Engineer-in-charge. Notes :- (i) The VCBs are installed at CPH, VCBs are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc.

5

-

-

... More
Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 11KV VCB/RMU panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc. (iv) The VCBs/RMUs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom,Schneider, Ashida, Siemens,L&T, C&S or any other of relays available on the site.

20

-

-

... More
Material & labour for Repair and maintanance of 11 KV HT RMU indoor/outdoor type, EACH WAY of RMU 400/630/800 Amp rating from HT Panel after switching off electric supply. Removal of all the possible mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, indication system, including checking the quality of insulating material, complete & refixing with faulty part replaced blowing out dust and applying the proper lubrication/ greasing and reassembling the including motorised operation and connection to HT panel & filling of gas (if quantity is lesser than required) and make the RMU functional to the entire satisfaction and as directed by the Engineer-in-charge. Notes :- (i) The RMUs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. (ii) Spare parts if replaced & if Gas filled shall be measured and paid separately under supply only items.

25

-

-

... More
Supply only SF6 gas suitable for HT33/11 KV RMU/VCB complete all as directed by Engr-in-charge.

10

-

-

... More
Supply only trip/closing coil suitable for HT, VCB/RMU, operating on 24/110 volt system and testing complete all as directed by Engr-in-charge.

10

-

-

... More
Supply only DC contactor operated on 110 / 24 volt system suitable for working of HT VCB/RMU complete all as directed by Engr-in-charge.

5

-

-

... More
Supply only Motor cut off limit switch sutable for HT 11 KV VCB/RMU complete all as directed by Engr-in-charge.

5

-

-

... More
Supply only Push Button element with one NO / NC complete all as directed by Engr-in-charge.

10

-

-

... More
Supply only Spring charging handle suitable of VCB/RMU charging as per sample all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply only TNC switch with wiring suitable for 11 KV VCB complete all as directed by Engr-in-charge.

2

-

-

... More
Supply & testing of spring charging mechanism with motor for outdoor/indoor type, 11KV, VCB/RMU,operated on 230/110/24 volts DC,with charging time less than 15 sec of approved rating complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fix in repair multifunction meter with LCD display suitabale for measuring 11 KV electrical parameters( Voltage, Amp, power factor, frequcncy. Kwh, harmonics upto 31 level) complete all as specified and directed

4

-

-

... More
Supply only Auxiliary switch 6 NO/6NC complete all as directed by Engr-in-charge.

2

-

-

... More
HT 33KVA OUTDOOR TYPE CT & PT Material & Labour for removal of bushing & terminals and cleaning CT/PT 33 KV by CTC solution on its insulators and teeths and checking the leakage if any from the CT and refixing the same after replacing the defective/faulty parts and checking the oil level and oil dielectric strength (BD test) and proper connection checking/tightening of control wiring and testing with the following :- (i) Meggar testing between phase to phase & phase to earth. (ii) Testing the terminal connection and its working for the calibration and tripping of the relay for the protection of HT 33KV line. Make it functional to the entire satisfaction of and as directed by Enginer-in-charge

2

-

-

... More
Supply & fixing in replacement indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed by Engr-in-charge.

15

-

-

... More
Supply and fix in replacement of Power Pack for 11 KV VCB/RMU suitable for incoming supply 220/110 volts and output 110/24 volts DC supply all as per existing with wiring complete all as directed by Engr-in-Charge. Note : - The contractor has to visit the site to check the existing system of 11 KV VCB/RMU for installation of power pack unit.

2

-

-

... More
Testing/Servicing of Transfromer 33/11 KV, up to 5 MVA Cleaing of power transformer 33/11 KV, outdoor type externally included all accessories (such as conservator tank, marshaling box, bushings, bucholz relay radiator, bushing,oil level indicator ) complete and checking the incoming and outgoing termianl connection complete with the following testing. (i) Transformer oil dielectric strength (BD voltage) test (ii) Buccholz realy alarm and trip testing (iii) Oil temperator alarm & trip testing (iv) winding tempreture alarm & trip testing (v) Meggar testing between HV to earth (vi) Meggar testing betweeen LV to earth) (vii) meggar testing between HV to LV (viii) earth resistenace test of transformer neutral. (ix) earth resistence test for body earthing

5

-

-

... More
Dismantaling top cover of transformer of capacity upto 630 KVA , any make for repair / replacement of HT / LT bushing of transformer , or for replacement of top cover gasket or for inspection of transformer or for internal repairs of transformer all including draining transformer oil as required / upto the required level, re fitting the top cover of transformer after completion of the work including testing complete etc all as specified and directed.Note - spare parts will be measured and paid seperatelly

4

-

-

... More
Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.

4

-

-

... More
M & L for replacement of defective silica gel breather with silica gel complete set upto 630KVA

20

-

-

... More
M & L for replacement of LT bushing of brass with neoprene rubber bush for Transformer upto 630KVA capacities.all as directed by EIC

20

-

-

... More
M & L for replacement of HT bushing of brass of transformer of any capacity upto 630 KVA.all as directed by EIC

15

-

-

... More
Suply only Silica gel complete all as specified and directed by engineer -in- charge

5

-

-

... More
Material, labour & T&P for Preparation of old painted iron surfaces of the transformer upto capacity 630 KVA, by cleaning / scrapping completely after that applying two coats of synthetic enamelled paint over a coat of primer on the transformer as per MES colour complete all as directed by Engr - In - Charge. Note : Painting shall be carried out with Spray Gun using compressor.

16

-

-

... More
Supply & filling of transformer oil in site for toping up the level of oil having dielectric strength between 55-65 KV during filling after initial filtration of any capacity complete all as specified and directed by engineer -in- charge.

1600

-

-

... More
M & L for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer/Voltage stabilizer with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV all as directed by EIC Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive of all above.

20000

-

-

... More
Dismantling of cross arms / bracing supports / clamps / back plates or any other structural steel sections including removing nuts bolts washers etc

3

-

-

... More
M & L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one rimer coat and two coats of aluminium paint after preparation of surfaces.

3

-

-

... More
Dismantling & taking down, old, defective, weak insulator, any type, any size any shape (pin / shackle / loop ).

84

-

-

... More
(a) S & F pin type insulator porcelain vitreous white / brown / green including one galvanised mild steel spindle, two galvanised iron washers, one galvanised iron nut, suitable for 11000 volts grade & of size 150 mm dia and 150mm height.

40

-

-

... More
(b) S & F pin type insulator porcelain vitreous white / brown / green including one galvanised mild steel spindle, two galvanised iron washers, one galvanised iron nut, suitable for 33000 volts grade.

20

-

-

... More
(a) S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.

12

-

-

... More
(b) S&F Disc type insulator, porcelain, vitreous, ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 33000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.

12

-

-

... More
Dismantling & taking down old, deteriorated, switch air break and supply and fixing switch air break gang operated triple pole mechanically operated horizontal/vertical type mounted on insulator & steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps horizontal type suitable for 11000 V. grade all as specufied and directed.

15

-

-

... More
Dismantling & taking down old, deteriorated, expulsion fuse assy and supply and fixing expulsion fuse single pole (drop out fuse) mounted on insulator & steel frame 100 Amps for 11000 V grade.

20

-

-

... More
M&L for servicing and greasing of mechanical parts of existing 33/11KV horizontal/vertical type GOD including replacement of parts i.e Male/female contact, jumper ,operating mechanism, GOD rod etc specified and directed by Engr-in charge

20

-

-

... More
Trimming/cutting the tree branches/ bushes around theHT over head line and making safe clearance up to 4.00 metre distance from line wire/panel all as directed by Engineer-in-Charge.

4000

-

-

... More
M&L of checking of HT 11/33KV cable of any size by means of HT Cable Fault Locator Machine by requisition for removal of HT cable faults complete all as specified and directed

26

-

-

... More
Supply and fix in repair cable joint kit for 11 KV grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 to 120 sqmm complete all as specified and directed by the Engineer - in - Charge.

10

-

-

... More
Supply and fix in repair cable joint kit for 33 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 300 sqmm complete all as specified and directed by the Engineer - in - Charge. Make : M-Seal/CCI/Siemens/Denson/Birla-3M/Raychems/Y-Denson/ RPG/ Yamuna Gases & Chemicals/Mohindera & Mohindera.

6

-

-

... More
Supply and fix in repair cable joint kit for 11 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 to 120 sqmm complete all as specified and directed by the Engineer - in - Charge.

10

-

-

... More
Supply and fix in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 sqmm complete including digging if required all as specified and directed by the Engineer - in - Charge.

12

-

-

... More
Supply and fix in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm complete including digging if required all as specified and directed by the Engineer - in - Charge.

8

-

-

... More
Supply and fix in repair Cable joining kit for 33 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete including digging if required all as specified and directed by the Engineer - in - Charge.

6

-

-

... More
Taking out old HT U/S cable of any size and any type as directed by Engr-in-charge.

260

-

-

... More
Supply and fix in trench/wall / pole XLPE insulated PVC sheated armoured heavy duty HT electric cable with aluminium stranded conductor 11000 volt grade of sizes 95 Sqmm 3 Core complete all as specified and directed.

200

-

-

... More
Supply and fix in trench/wall / pole XLPE insulated PVC sheathed armoured heavy duty HT electric cable with aluminium stranded conductor 33000 volt grade of sizes 300 Sqmm 3 Core complete all as specified and directed.

60

-

-

... More
S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on HT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/capacity, complete all as specified and as directed. Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.

4

-

-

... More
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Eng In charge.

5500

-

-

... More
.Supply and lay stone aggregate of size 40mm to 63mm graded layed on ground of yard/ two/four pole structure complete all as specified and directed.

90

-

-

... More
M&L in repair of Earthing complete with copper earth plate electrode, 60x60cmx 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip of 20x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion as per direction of Engr-in charge.

10

-

-

... More
Material and labour copper strip as earth continuity conductor or main earthing lead of size 20 x 3 mm

20

-

-

... More
M&L in repair for earthing complete with GI earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including GI earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m as directed.

10

-

-

... More
Material and labour galvanised iron strip as earth continuity conductor or main earthing lead of size 32 x 6 mm

20

-

-

... More
Material & labour for Painting of all 2 pole/ 4 pole structure according to MES colour coding such as pole, structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge

10

-

-

... More
Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 33KV VCB panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc. (iv) The VCBs/RMUs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom,Schneider, Ashida, Siemens,L&T, C&S or any other of relays available on the site.

3

-

-

... More
Material & labour for Repair,Manitenance of 11KV HT Capacitor bank outdoor/Indoor type complete including the following (a) Checking the serviceability by Meggaring of each capacitor unit of any capacity.(b) Replace defective minor parts ( thimble, wire connections, ..etc) and blowing out dust and including connection to HT panel and make the capacitor bank functional to the entire satisfaction of Engineer-in-charge. .

2

-

-

... More
Material & labour for Repair,Maintenance of 11KV HT Potential Transformer complete including the following (a) Checking the serviceability by Meggaring of each PT unit of any capacity.(b) Replacement of defective parts i.e fuse of any capacity,connection wire etc and blowing out dust and including connection to HT panel and make the PT functional to the entire satisfaction of Engineer-in-charge. .

2

-

-

... More
Supply, installation, testing and calibration of relay 110/24V of Microprocessor based three phase relay system to overcurrent, one earth fault protection type for 11 KV breaker, setting range suitable for over current and earth fault with necessary wiring/fitting including dismantling of old IDMT or unserviceable relays.The setting of the relay should be in accordance with the incomer and setting should be maintained such that fault does not carry beyond the affected feeder in case of Overload,3 phase fault, earth fault etc complete all as specified and directed by the Engineer-in-Charge. Note :- The calibration of relay of Microprocessor based three phase relay system required to carried out at CPH. Make C&S model no. CSENex-I 150 in equivalent Schenider, Siemens. (ii) The calibration of relay of Microprocessor based three phase relay system to be carried out by OEM representative.

3

-

-

... More
Supply and fix in replacement of power factor improvement capacitor oil immersed three phase static 12 KV capacitor with manual control 50 KVAR complete will all insulation for terminals as directed by EIC.

4

-

-

... More
Material & labour for two coat of Aluminium Painting MS angle of 5MVA Yard at CPH such as structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge

1

-

-

... More
Material & labour for two coat of Aluminium Painting MS angle of 1MVA Yard at CPH such as structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge

1

-

-

... More
Boring of holes under road, pavement, hard standing by manual method including 100mm of HDPE pipe complete all as specified and directed.

60

-

-

... More
Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia

0.5

-

-

... More
Dismantling old pcc poles/struts, any size.

10

-

-

... More
Supply and fix (in replacement of PCC pole) steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long)

6

-

-

... More
Supply and Fix in replacement Prestressed concrete pole 9.0 metres long, 102x172mm at top and 102x279mm at bottom, class 10 complete all as specified and directed.

4

-

-

... More
Supply and fix in repairs for stay assembly as shown in electrical plate No 1 of SSR part I comprising of 7/3.15 mm galvanised mild steel stranded stay wire of required length fixed to pole with and including FI clamps of size 50x6 mm, bolts, nuts, washers, stay rod of 20 mm dia 2.15 mtrs long, stay bow with nuts bolts washers, galvanised steel plate 230x230x6 mm including loop insulators over all dimensions 90mmx140 mm cleearance of hole 25.5 mm complete including taking down old unserviceable stay assembly all as specified and directed.

3

-

-

... More
M & L in repairs lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts.

6

-

-

... More
Supply and fix in repairs HT cable mild steel route marker with angle of size 35mmx35mmx5mm and 600 mm long all as specified and as directed. Note :- Earth work and PCC work shall be measured and paid separately.

40

-

-

... More
Re-stringing and stretching of OH line of ACSR 33/11 KV rating conductor on 11m height steel tubular pole including pruning of tree branches and cleaning of insulators and aluminium wire within the span of 60m for binding all as directed. Note : One RM s\span is measured for one RM span of 3 Nos conductors.

600

-

-

... More
S&F PVC sleeves (Red/Yellow/Blue) for jumper connections and connector on poles at sub stations complete all as specified and directed.

450

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.

400

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil speciallu for LT pole stay assembly complete all as specified and directed.

1

-

-

... More
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / hard dense soil complete all as specified and directed.

340

-

-

... More
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.

60

-

-

... More
M&L Sand cusioning of tibba sand for XLPE cable with screened & washed sand & punning to provide a required cover complete all as specified and directed.

160

-

-

... More
Supplying and laying reinforced precast concrete cable cover, Class HVP, Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed.

1000

-

-

... More
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.

4000

-

-

... More
Labour only for retrived stone patty from excavation complete all as specified and directed.

50

-

-

... More
M&L for cement concrete 1:3:6 type C2 using 40 mm graded as in foundation filling and mass concrete complete all as specified.

6.48

-

-

... More
M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) for coping including form work etc complete all as specified and directed.

0.65

-

-

... More
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.

0.75

-

-

... More
Disconnect of Electric supply , GI / Copper strip and taking down distribution transformer carefully lifting by crane . Transporting the transformer safely to the workshop and back for repair . Re- install , re - connect of electric supply , GI / Copper strip and testing on load all as specified and as directed for the following capacity of transformers . (a) Capacity 200 KVA to 400 KVA

4

-

-

... More
(b) Capacity 50 KVA to 150 KVA

4

-

-

... More
(C) Capacity 500 KVA to 1000 KVA

2

-

-

... More
Opening the top of the Distribution transformer 11KV/430 Volts, draining out transformer oil, cleaning the internal portion of tank, core and connections by mechanical means and force feeding of transformer oil and flushing out deposits, sludge etc, and closing the top complete all as specified and directed for the following capacity of transformers:- (a) Capacity 200 KVA to 400 KVA

2

-

-

... More
(a) Capacity 200 KVA to 400 KVA

2

-

-

... More
(b) Capacity 500 KVA to 1000 KVA

2

-

-

... More
Material and labour for Rewinding of transformer Step up / down , HV Coils complete with existing size/ electrolytic copper conductor design with TPL covering, re-assembling of newly wounded coils on core in position including re- insulation oven baking and testing complete all as specified & directed for the 50-1000KVA transformers

300

-

-

... More
Material and labour for Rewinding of transformer Step up / down , LV Coils complete with existing size/ electrolytic copper conductor design with TPL covering, re-assembling of newly wounded coils on core in position including re- insulation and testing complete all as specified & directed for the 50-1000KVA transformers .

280

-

-

... More
Material and labour for replacement of unserviceable gaskets with Neoprene sheet 6 mm thick, nut bolts washers complete all as specified and directed.

10

-

-

... More
Material and Labour for replacement of HT bushings with brass rod of size suitable for following capacity Transformer, including cork sheet gaskets, complete all as specified and directed for the following capacity of transformer :- (a) Capacity 200 KVA to 400 KVA

6

-

-

... More
(b) Capacity 50 KVA to 150 KVA

6

-

-

... More
(c) Capacity 500 KVA to 1000 KVA

3

-

-

... More
Material and Labour for replacement of LT bushings with brass rod of size suitable for following capacity Transformer, including cork sheet gaskets, complete all as specified and directed for the following capacity of transformer :- (a) Capacity 200 KVA to 400 KVA

8

-

-

... More
(b) Capacity 50 KVA to 150 KVA

8

-

-

... More
(c) Capacity 500 KVA to 1000 KVA

4

-

-

... More
Taking out carefully PVC insulated sheathed armoured stranded aluminium conductor LT underground cable from trenches/ ducts/ walls etc., including necessary dismantling, demolition and disconnecting cables from existing power line complete all as specified and as directed for the following sizes of cable:- Note :- (i) Earth work excavation, returning filling and disposal shall be measured & paid separately under respective items. (ii) The surface disturbed during dismantling/demolition shall be made good by contractor at his own cost by using 1:2:4 type B1 concrete (or) in CM 1:4 which deemed to be included in the contractor quoted rate. (a) 10 Sqmm 2 Core

100

-

-

... More
(b) 16 to 25 Sqmm 3.5 Core

450

-

-

... More
(c) 50 to 95 Sqmm 3.5 Core

650

-

-

... More
(d) 150 to 185 Sqmm 3.5 Core

330

-

-

... More
Supply lay & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the following size of cable:- (a) 10 Sqmm 2 Core

100

-

-

... More
(b) 16 Sqmm 4 Core

200

-

-

... More
(c) 25 Sqmm 4 Core

250

-

-

... More
(d) 50 Sqmm 3.5 Core

350

-

-

... More
(e) 95 Sqmm 3.5 Core

300

-

-

... More
(f) 150 Sqmm 3.5 Core

230

-

-

... More
(g) 185 Sqmm 3.5 Core Notes for item No 106 to 112 (i) The minor parts such as clamps, screw etc.,, required for fixing cables on wall, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate. (ii) Earth work excavation, returning filling and disposal, protection pipe & joint kit shall be measured & paid separately under respective items.

100

-

-

... More
Material and labour for Galvanised steel tubing, light grade laid in trenches/ fixed to poles, walls etc as a protection for service cable including removing existing old unserviceable rusted pipe complete all as specified and directed for the following size of pipe:- (a) 50mm dia bore

30

-

-

... More
(b) 80mm dia bore

30

-

-

... More
(C) 100 mm dia Notes for item No 113 to 115 :- (i) The minor parts such as clamps, screw etc.,, required for fixing pipe on wall, pole, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate.

40

-

-

... More
M&L for providing horizontal bore hole of dia upto 120mm below road/hard standing surface for the length upto 10 Metre and inserting GI/PVC pipe into the bore hole as cable protection complete all as specified and as directed. Note:- Cable protection pipe shall be measured and paid separately under relevant item.

60

-

-

... More
S&F in repair of air circuit breaker of 630A 4 pole manual drawout thermal megnetic release type as directed of following charactorstics :- Ratings : 630 A Breaking Capacities : 50kA 4 Pole Versions with Draw-out configurations High Short time withstand capacity, Icu=Ics=Icw for 1 sec for total selectivity Different terminal orientations: Flat,/Horizontal/ and Vertical

1

-

-

... More
S&F in replacement of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 70 to 120 sqmm complete all as specified and directed.

8

-

-

... More
S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 150 to 185 sqmm complete all as specified and directed.

6

-

-

... More
S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 25 to 50 sqmm complete all as specified and directed.

9

-

-

... More
S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 240 to 300 sqmm complete all as specified and directed.

8

-

-

... More
M&L complete removal of existing treatment and applying two coats of synthetic enamel paint on steel poles (single pole) upto 2.4m height as existing on site in strip of 0.6m height in blue and white colour alternatively as per existing pattern including GI brackets and clamps and balance height to be paited with two coat of aluminium paint including mentioning pole Nos reflector type on each pole complete all as specified and directed.

20

-

-

... More
M & L for repairing of broken/damage pin/disc insulator, ACSR conductor..etc , trimming of line as required of 33KV line( from CPH/ MRS to Civil area take of point GSS ) after proper shutdown of electric supply and jumpring / cut points changing the damaged/burned conductor, cable endes,condutor broken due to wind/storm and binding with the aluminium wire etc and changing the damaged pin/disc insulators and replace the broken conductor, repairing the faults in the 33/11 KV outdoor/ indoor electric panels at sub stations complete all as specified and directed by engineer-in-charge.( Note :- cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted item.,(ii) cost of trimming tree and Cost of items that is pin insulator,disc insulator etc. shall be measured and paid seprately under respective items.(iii)contrator take complaints from complaints cell(JE E/M)and rectify the same day deposited the same as all directed by engr-in-charge.

2

-

-

... More
Supply and fix in repair touch proof termination joint kit, Fully watertight cable terminations -IP 67 ingrss protection, connectors suitable for outdoor cable termination without cable box,tee connectors should be piggy-backed to allow multiple cable onto bushings , maximum volatge 11KV-24KV with current rating 250-400 Amps for 11 KV grade cable/RMU for outdoor termination type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.

2

-

-

... More
Supply and fix in repair touch proof termination joint kit, Fully watertight cable terminations -IP 67 ingrss protection, connectors suitable for outdoor cable termination without cable box,tee connectors should be piggy-backed to allow multiple cable onto bushings , maximum volatge 33KV with current rating 630 Amps for 33 KV grade cable/RMU for outdoor termination type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120-300 sqmm complete all as specified and directed by the Engineer - in - Charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.