Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,30,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689908_1Tender No
84271/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil complete all as specified and directed by Engineer-in-charge.
781
-
-
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated rock complete all as specified and directed by Engineer-in-charge.
185
-
-
... More
M&L for sand cushioning to underground PVC/XLPE cable and punning to provide required cover complete all as specified and directed by Engineer-in-charge. Note :- For the purpose of payment only punned thickness will be measured.
441
-
-
... More
Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30 cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.exc 10 mm complete all as specified and directed by Engineer-in-charge.
1290
-
-
... More
Re-laying only of existing Jodhpur Stone Patti cable cover in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 9.00 here-in-before) complete all as specified and directed by Engineer-in-charge.
71
-
-
... More
Taking down/out unserviceable LT UG Cable of any descriptions, laid in trenches and/or fixing with Walls/Poles including stone patti complete all as specified and directed by Engineer-in-charge.
6500
-
-
... More
Supply, lay, test and commissioning of LTUG, XLPE insulated, heavy duty, 1100V grade of size 240 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and directed by Engineer-in-charge. Note : Earthwork excavation sand cushioning ,Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
200
-
-
... More
All as per Item No 10.00 here-in-before but size 120 sq mm. 3½ core
500
-
-
... More
All as per Item No 10.00 here-in-before but size 95 sq mm. 3½ core
900
-
-
... More
All as per Item No 10.00 here-in-before but size 70 sq mm. 3½ core
1350
-
-
... More
All as per Item No. 10.00 here-in-before but 50 sq mm. 3½ core
1750
-
-
... More
All as per Item No. 10.00 here-in-before but 35 sq mm. 3½ core
500
-
-
... More
All as per Item No. 10.00 here-in-before but 25 sq mm. 4core
500
-
-
... More
All as per Item No. 10.00 here-in-before but 10 sq mm 2 core
300
-
-
... More
Relaying /Refixing only existing XLPE insulated , Armoured , Electric Power UG Cable (Heavy Duty) , 1100 Volt Grade , any Cross sectional area (Serviceable Materials obtained from Item No. 9.00 here-in-before) complete all as specified and directed by Engineer-in-charge.
500
-
-
... More
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-charge.
96
-
-
... More
S&F in repair GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete all as specified and directed by Engineer-in-charge.
72
-
-
... More
All as per Item No. 20.00 here-in-before but size 80mm dia
36
-
-
... More
All as per Item No. 20.00 here-in-before but size 100mm dia
18
-
-
... More
Supply, installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protction class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down panel existing etc complete all as specified and directed by Engineer-in-charge. Location 26 Amn Coy near OR Line The panel shall consists of following accessories:- Incoming Side
(i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No
(ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T Part No- WL411021OO00
(iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000.
2
-
-
... More
Contd Item No. 23.00 (iv) Bus bar strips made of Aluminium 600 Amps (Make - Hindalco) of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation
(v) CT 400/5A) -03 Nos OUTGOING :- (i) MCCB 4 Pole of capacity 250 Amp , breaking capacity 36KA with thermal release- - 1 Nos
(ii) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 2 Nos
(iii) MCCB 4 Pole of capacity 100 Amp , breaking capacity 25 KA with thermal release - 1 No
(iv) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16 KA with thermal release -03 Nos
(v) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. (iv) Austro Timer switch model AUTOSORASTOO MAKE L&T
NOTE :- All MCCBs to be Ics =100%Icu
-
-
-
... More
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down old unsv panel etc complete all as specified and as directed. Location-26 Amn coy near Lower AC Plant The panel shall consists of following accessories:- Incoming Side :-
(i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No
(ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T Part No- WL411021OO00
(iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000.
1
-
-
... More
Contd Item No. 24.00 (iv) Bus bar strips made of Aluminium 600 Amps (Make - Hindalco) of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation
(v) CT 300/5A) -03 Nos OUTGOING :- (i) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 2 Nos
(ii) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release - 1 No
(iii) MCB TPN of capacity 63 Amp , 415 Volt -01 Nos
(iv) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. NOTE :- All MCCBs to be Ics =100%Icu
-
-
-
... More
Supply, installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protction class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down panel existing etc complete all as specified and directed by Engineer-in-charge. Location 26 Amn Coy near Carpenter shop and Post No.6 The panel shall consists of following accessories:- Incoming Side :- (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No Make L&T Cat Part No. WL411021OO00 (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T Cat Part No. SIL-00000
2
-
-
... More
Contd Item No. 25.00 (iv) Bus bar strips made of Aluminium 400 Amps (Make - Hindalco) of suitable size required length – 04 Nos, aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (i) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25 KA with thermal release- - 2 Nos (ii) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release -1 No (iii) MCB TPN of capacity 63 Amps 415 V - 01 Nos (iv) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. NOTE :- All MCCBs to be Ics =100%Icu
-
-
-
... More
Supply, installing, testing and commissioning outdoor type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protction class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long. duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down panel existing etc. complete all as specified and directed by Engineer-in-charge. Location 26 Amn Coy near ECG Building The panel shall consists of following accessories:- Incoming Side :-
(i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. L&T Part No- WL411021OO00 (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T Cat Part No. SIL-00000
1
-
-
... More
Contd Item No. 26.00 (iv) Bus bar strips made of Aluminium 400 Amps (Make - Hindalco) of size 40 xmm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING :- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release - 1 No (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release- - 3 Nos (c) MCB TPN of capacity 63 Amps 415 V - 01 Nos (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. NOTE :- All MCCBs to be Ics =100%Icu
-
-
-
... More
NOTE FOR ITEM Nos 23.00 TO 26.00 BOQ srl Item No. 23.00, 24.00, 25.00 and 26.00 will be executed only after obtaining necessary recommendation of replacement from EI/AEI as per defined in the guidelines.
-
-
-
... More
Dismantling & taking down ACSR conductor, of any size, after taking necessary shut down, for 11 KV HT/LT OH line, by loosening the binding wires, jumpers etc. for replacement of insulator / cross arms etc. complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Dismantling of 9 mtr long PCC/RCC poles after breaking the foundation concrete including necessary excavation of earth, filling the hole with broken pieces of concrete and making good the disturbed area by filling excavated earth, obtained from the hole for new pole to be erected nearby area, to match with the surroudings complete all as speficied and directed by Engineer-in-Charge.
10
-
-
... More
Supply, Transportation, fixng and errection of prestressed cement concerte pole 9 mtr long, miximum cross section 102mmx172mm at top and 102mm x 279 mm at bottom class-10 conforming to IS 01678 and including making alternate white and black strips 30cm height (total No-05 Nos), primer two cots of synthetic enamle paint oer a coat of primer complete all as speficied and directed by Engineer-in-Charge.
10
-
-
... More
M & L for cross arms bracing support clamps and back plates channel or angle section nuts bolts etc after painting with two coat of aluminium paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Refixing of cross arms/clamps/nuts/bolts/washers etc. (as dismantled under item No. 28 above) on the refixed/new steel poles of any length with one coat of aluminium paint complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Restretching only existing ACSR of any size on HT/ LT pole including binding the ACSR with insulators, aluminium binding wire complete all as speficied and directed by Engineer-in-Charge. Note :- (i) The above work includes cleaning pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of 4/5/6 conductors & GI wire.
27
-
-
... More
Supply and fixing aluminium conductor steel reinforced [ACSR] straining properly on insulators on PCC pole and binding with aluminium tape/binding wire, connectors, jumpers of required size etc complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Supply & Fix Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade Including taking down old unserviceable Pin type Insulator complete all as speficied and directed by Engineer-in-Charge.
40
-
-
... More
S&F new Shackle type, Insulator porcelain, vitreous 75mm high and 90mm dia ball and socket type (white/brown/green) complete single disc assembly for tension with tension clamps syitable for ACSR conductor working pressure 1100 volts grade Including taking down old unserviceable Pin type Insulator complete all as speficied and directed by Engineer-in-Charge.
10
-
-
... More
M & L for cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate for foundation of stay assembly struts or pole or around the pole structure etc complete all as speficied and directed by Engineer-in-Charge.
Note: PCC (1:3:6) work in around the pole structure min 100mm thickness after cleaning the surface area.
39
-
-
... More
M&L for cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for coping around poles including necessary form work finishing even and smoth with out using extra cement complete all as speficied and directed by Engineer-in-Charge.
20
-
-
... More
M&L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as speficied and directed by Engineer-in-Charge.
0.45
-
-
... More
S&F in repairs High density polyethylene pipes (HDPE) of size 50mm dia for cable protection complete all as speficied and directed by Engineer-in-Charge.
500
-
-
... More
M&L for painting the old existing LT panel board /feeder pillars of size 1200x1050x450mm including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint (Gray paint) and without distrubing the existing electric system and removing grass and bushes including its roots growing around the panel complete all as speficied and directed by Engineer-in-Charge.
12
-
-
... More
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication CRCA sheet upto 3.15mm thick in existing, shape and size with and including all jointing material such as hinges, nuts, bolts or washer and welding etc complete all as speficied and directed by Engineer-in-Charge. NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/ Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
200
-
-
... More
S&F in repair of GI wire (guard wire) of dia 4 mm minimum complete fixing below the HT /LT over head line counductor including fixing on height of 6 to 9 mtr above ground level in shape and size complete all as speficied and directed by Engineer-in-Charge.
Note :- Complete in all respect including the arrangement of tools requested to be carry for job.
6
-
-
... More
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete all as speficied and directed by Engineer-in-Charge.
Note :- Only effected area of over head conductor shall be measured as per running meter.
500
-
-
... More
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete and including dismantling/taking down Old unserviceable Earthing complete all as speficied and directed by Engineer-in-Charge.
20
-
-
... More
S&F feeder pillar made out of 3.15mm CRCA sheet, power coated minimum 80 Micron, weather proof, size not lett than 800 (w)x600(H)x500(D) mm out door single dooor, with FRP inculstor 1100V, Aluminium Busbar 200 Amps current density not less than 2.0 shall be mounted on MS angle stand 40x40x5mm height 400mm above ground level and 200mm under PCC structure, earthing bolt to be provided M10 complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete and including taking down old unserviceable feeder pillar complete all as specified and directed by Engr-in- Charge.
5
-
-
... More
S&F feeder pillar made out of 3.15mm CRCA sheet, power coated minimum 80 Micron, weather proof, size not lett than 800 (w)x600(H)x500(D) mm out door single dooor, with FRP inculstor 1100V, Aluminium Busbar 100 Amps current density not less than 2.0 shall be mounted on MS angle stand 40x40x5mm height 400mm above ground level and 200mm under PCC structure, earthing bolt to be provided M10 complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete and including taking down old unserviceable feeder pillarcomplete all as specified and directed by Engr-in- Charge.
5
-
-
... More
M&L straight through joints (epoxy) for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size16mm to 25mm 4 core including taking down Old unserviceable Joints complete all as speficied and directed by Engineer-in-Charge.
4
-
-
... More
M&L straight through joints (epoxy) for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 35mm to 50mm 3½ core including taking down Old unserviceable Joints complete all as speficied and directed by Engineer-in-Charge.
4
-
-
... More
M&L straight through joints (epoxy) for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 70mm to 95mm 3½ core including taking down Old unserviceable Joints complete all as speficied and directed by Engineer-in-Charge.
5
-
-
... More
M&L straight through joints (epoxy) for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 120mm to 150mm 3½ core including taking down Old unserviceable Joints complete all as speficied and directed by Engineer-in-Charge.
2
-
-
... More
Supply and fixing MCCB 4 Pole 400 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing Panel at site (ICS=ICU 100%)
4
-
-
... More
Supply and fixing MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing Panel at site (ICS=ICU 100%)
4
-
-
... More
Supply and fixing MCCB 4 Pole 200 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing Panel at site (ICS=ICU 100%)
5
-
-
... More
Supply and fixing MCCB 4 Pole 160 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing Panel at site (ICS=ICU 100%)
6
-
-
... More
Supply and fixing MCCB 4 Pole 100 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing Panel at site (ICS=ICU 100%)
8
-
-
... More
Supply and fixing MCCB 4 Pole 63 Amps, rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing Panel at site (ICS=ICU 100%)
12
-
-
... More
Taking out existing broken/unserviceable stay assembly and S&F new stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm X 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm and shown in electrical plate No. 1 of SSR part-I complete all as specified and directed by Engineer-in-charge. Note : Excavation and concrete shall be measured separately under respective items.
3
-
-
... More
S&F in repair electronic spices assorted Polyolefin heat shrink tube of size 25mm for LT UG Cable insulation of size 16 sqmm to 35 Sqmm with colour code (R,Y & B) complete all as specified and directed by Engineer-in-charge.
150
-
-
... More
S&F in repair electronic spices assorted Polyolefin heat shrink tube of size 50mm for LT UG Cable insulation of size 50 sqmm to 120 Sqmm with colour code (R,Y & B) complete all as specified and directed by Engineer-in-charge.
150
-
-
... More
Supply, Laying, jointing and testing in repair of XLPE insulated unscreened PVC bedded, galvanized steel strip armoured electric power cable heavy duty with aluminium conductor 1100 volt grade,ISI Marked, laid in trenches/pipes/ducts/under road of size 300 sqmm 3.5 core including necessary cable glands, lugs etc complete, including taking out old unsv existing cable complete all as speficied and directed by Engineer-in-Charge.
100
-
-
... More
M&L for finding cable fault with electronic fault detector in HT/LT UG cable of size 25 to 300Sqmm complete including earthwork and jointing cable complete all as speficied and directed by Engineer-in-Charge.
Note :- LT UG & Joint Kit shall be measured paid separately under relevant items.
5
-
-
... More
S&F LT cable route indicator made out of cast iron plate of 150 mm dia 4mm thick having embosed wiriting LT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts,bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm) complete and including taking down existing unserviceable cable route complete all as speficied and directed by Engineer-in-Charge.
210
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%