Local Self Government Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 52,460Document Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DLB_419311_1Bid Award Id
ViewTender No
NIT-04/2024-25-MCB LIGHTTender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://https://lsg.urban.rajasthan.gov.in/content/raj/udh/lsg-jaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA.driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min=4KV internal and 10KV external but inside driver compartment, ystem life of 50000 Burning hourswith 70% of Initial Lumens aintained, CRI70 and CCT 5700K ±355K. Manufactures Word rk/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbe IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LEDfixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shallbe submitted. All as per pre approved by gineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
High Power LED Flood Light Minimum lumen output 3700 lm
130
354250
2725
High Power LED Flood Light Minimum lumen output 6200 lm
10
32930
3293
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed
Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -
I of 1.1 KV with H4- Grade electrolytic aluminium conductor
confirming to IS 8130 of purity 99.6 %, round / flat strip armouring
of cables, Inner / outer sheath confirming to IS:5831 in existing RCC
/ Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable
tray(with cable tie) including testing etc. as required of following
size. OEM must have it's own in house NABL accrediated
Laboratory for testing procedure as per IS:10810.For additional
technical parameters of product / work refer Annexure 'A' attached
with this BSR
-
-
-
4.0 Sq. mm
-
-
-
4.0 Sq.mm 4 core
1000
142000
142
Providing & Fixing of IK10 IP65 protected 600 mm height LED
Bollard Luminarie with base plate made of powder coated die cast
alluminium housing with UV stabalized PC diffuser. The System
level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used,
System CRI70, CCT: 3000/4000/6500 K. The integral electronic
driver must be potted & has a unique BIS R number must be potted
& has a unique BIS R number constant current and Internal/external
surge protection device of min. 4KV(L-N) and efficiency 85%,
PF0.9, THD20% and input Voltage range of 90-270V AC at 50Hz.
System life of 30000 Burning hours with 70% of Initial Lumens
maintained Light output in Cool white or Warm White Colour as per
engineers choice. driver current 750mA. Fixture must be in
compliance with BIS Standards and Trade mark Certificate complete
in all respect.OEM Must have its own in house NABL lab setup for
all testing facilities for LED fixtures. (LM79/LM80) Certificate/
report with liable warranty of product/accessories from OEM shall be
submitted. All as per pre approved by Engineer in-charge. For
additional technical parameters of products/ work , refer Annexure
"A" attached with this BSR .
-
-
-
Minimum lumen output 800 lm Bollard
120
1174200
9785
Providing & Fixing of IK10 IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder
coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥90 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronicdriver must be potted & has a unique BIS R number constant current and Internal/external surge
protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . drivercurrent 750mA . Fixture must be in compliance with BIS Standards and Trade mak Certificate completein all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of
products/ work , refer Annexure "A" attached with this BSR .
-
-
-
Minimum lumen output 450 lm Step light
27
102330
3790
Providing & Fixing of IK10 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. COB LEDs is to be used,
System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant currentand Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current 750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with
-
-
-
Minimum lumen output 800 lm Up-Down Luminary
50
329350
6587
Supplying and drawing FR PVC insulated & unsheathed flexible
copper conductor as per PWD specification for electrical Works with
ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire
should be made from 99.90 % purity copper, class 5 stranding in
acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less
chances of oxidization, insulation PVC type A/C/D , flame retardant
as per IS 10810-53, better amperage rating as per IS:3961 part 5, in
existing surface or recessed PVC/ MS conduit/casing capping
making connections with Copper Lugs of suitable size,
Ferrules,testing etc. as required. OEM Must have its own in house
NABL lab setup for all testing facilities for wires. For additional
technical parameters of product / work refer Annexure 'A' attached
with this BSR
-
-
-
2 x 2.5 sq.mm
400
25200
63
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. '
B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387
with perforated holes of 12 mm dia ,including all accessories like nut,
bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather
proof poly-propylene earth pit chamber with lockable Jam free lid
suitable for safe working load 5000 Kg or more of size Top Dia. 225
to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.
and embodying the pipe complete with alternate layers salt and
coke/ charcoal, testing of earth resistance for value of 5 ohms or
less as required & must record by engineer in-charge during site
visit and ensure to enter in measurment book.All as per pre
approved by Engineer in-charge. For additional technical
parameters of products/ work , refer Annexure "A" attached with
this BSR .
32
119488
3734
Supply & Laying following size earth wire in horizontal or vertical run
in ground/surface/recess including riveting, soldering, saddles,
making connection with GI/Cu purity purity 95% thimble etc. as
required. All as per pre approved by Engineer in-charge. For
additional technical parameters of products/ work , refer Annexure
"A" attached with this BSR .
-
-
-
10 SWG G.I. ( Hot Dipped ) Wire
500
7000
14
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured
Copper cable confirming to IS:1554 P-I / IS :7098 P - I of
1.1 KV with electrolytic grade Copper made of copper rods
confirming to IS 613-1964, of purity 99.7 %, Inner / outer sheath
confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC
pipe/ open duct/cable trench / Cable tray (with cable tie) including
testing etc. as required of following size. OEM must have it's own in
house NABL accrediated Laboratory for testing procedure as per
IS:10810 For additional technical parameters of product / work refer
Annexure 'A' attached with this BSR
-
-
-
1.5 Sq. mm
-
-
-
2 Core
200
18000
90
Providing & Fixing of IP - 65 protected impact resistant
polycarbonate / Polysterene enclosures with knock out for cable
entry/out including fixing with nut, bolt, fatner etc as required
complete in all respect of following sizes.All as per pre approved by
Engineer in-charge. For additional technical parameters of products/
work , refer Annexure "A" attached with this BSR .
-
-
-
250 x 200 x 115 mm
32
71296
2228
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205
P-24, Stiffness Class 750 N, Externally corrugated and having
smooth surface inside with HDPE Coupler, Elbow, Tee at required
Depth below the ground for laying cable of following Nominal Outer
dia. MFR Test report from NABL accrediated is to be
submitted.(Excavation of Earth & Back filling with compaction is to
be Paid Extra)All as per pre approved by Engineer in-charge. For
additional technical parameters of products/ work , refer Annexure
"A" attached with this BSR .
-
-
-
75 mm
150
19950
133
Add Extra for Laying of one number PVC insulated and PVC
sheathed / XLPE power cable of 1.1 KV grade direct in ground
including excavation of trench of size 75 cm (Depth) x 35 cm(Width)
, with procedure as per following points:- (a) Make a river
sand bed of height 125 mm along the trench, (b) Lay the cable in
the middle of the trench, (c) Provide river sand bed of height 125
mm on top of the cable, (d) Lay the protective Common burnt clay
F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm
thickness and 225 mm wide just above the sand bed vertically
across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the
excavated soil leaving 300 mm from the Ground level, (f)Lay the
Cable warning tape and again back-fill the remaining portion of the
trench upto the ground level and compacting the earth
1000
190000
190
Add Extra in Item no.60.5 if Excavation done in Hard Rock / CC road
/ TAR Road and making Good the same
300
7500
25
S&F following sizes (dia.) of ISI marked virgin material MMS (
IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988)
accessories as required in recess including cutting the wall,
covering conduit and making good the same as required. For
additional technical parameters of product / work refer Annexure 'A'
attached with this BSR
-
-
-
25 mm
200
11400
57