Local Self Government Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Local Self Government Department - LSGD Tender
Electrical and Electronics
Eprocure
Opening Date5 Oct 2024
Closing Date14 Oct 2024
Tender Amount₹ 10,00,000
Costs
EMD
₹ 5,000Document Cost
₹ 1,000Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DLB_425949_1Tender No
Vidyut-06/2024-25Tender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://https://lsg.urban.rajasthan.gov.in/content/raj/udh/lsg-jaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
53.6 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
53.6.1 4.0 sq.mm
1
-
62
53.6 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
53.6.2 6.0 sq.mm
1
-
75
53.6 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
53.6.3 10.0 sq.mm
1
-
100
53.1 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130: 2013 of 1.1 kV grade Wire should be made from 99.90% purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
53.1.2 2X1.5 sq.mm
1
-
44
58.3 SITC of 3/4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P-2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR, shunt trip, earth fault trip, door interlock, pad lock & rotary handle, including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product/work refer Annexure 'A' attached with this BSR
58.3.1 3 pole MCCB With Thermal Magnetic release
58.3.1.2 up to 100 Amp, 25 kA,adjustable O/L & adjustable S/C setting.
1
-
5299
55.2 Providing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation, two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL/CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
55.2.2 Triple pole Isolator
55.2.2.3 80 A/100 A rating
1
-
822
57.20 Providing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
57.20.2 One day & week reserve (Analog type)
1
-
4807
57.14 Providing of AC operated heavy duty 230/440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1: 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR.
57.14.2 4 pole Power contactors with following AC 1 Rating
57.14.2.6 100 Amp
1
-
8045
एल.ई.ड़ी लैम्प ई-27 = 12W प्रतिनग (सूर्या / बजाज / कोम्टन)
1
-
105
60.1 Providing P.V.C. / XLPE insulated & P.V.C. sheathed UnArrmoured Aluminium cable confirming to IS:1554 P-1/IS:7098 P-I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6%, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
60.1.3 10.0 Sq. mm
60.1.3. 1 2 core
1
-
114
Supply 5.5 Mtr aluminium ladder
1
-
9515
एल.ई.ड़ी लैम्प पिन 12W प्रतिनग (सूर्या / बजाज / कोम्टन)
1
-
98
होल्डर ई. एस-27 चुडीदार प्रतिनग
1
-
110
प्लास तापडिया प्रतिनग
1
-
100
Extention Board 8 mtr प्रतिनग
1
-
500
पैचकस 12 ईच (ISI Marked) प्रतिनग
1
-
80
दस्ताने प्रति जोड़ी
1
-
600
55.1 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV Impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
55.1.1 Single pole MCB (With B/C curve tripping Characteristics)
55.1.1.4 50/63 A rating
1
-
425
66.1 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver, System lumen efficacy ≥ 110 Im/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10% , P. F.≥0.95, CRI 80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
66.1.1 1170mm(+/-10%) LED batten with min. lumen output 2200 lm
1
-
504
Evaluation Notes How It Works ?