If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 39,800Document Cost
₹ 1,000Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_DLB_304647_1Bid Award Id
ViewTender No
58/2022-23Tender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://http://lsg.urban.rajasthan.gov.in/content/raj/udh/lsg-jaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of
bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per
drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawingsIn all kind of soilUpto 3.0 m depth
90.24
-
175.5
... More
Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
5
-
221.5
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :1:3:6 (1 Cement : 3 fine/ coarse sand : 6 graded stone aggregate 40 mm nominal size
11.59
-
4675
... More
Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:6 (1 cement : 6 coarse sand)
49.75
-
4245
... More
Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50m and lift upto 1.5m
90
-
144
... More
Random rubble dry stone Kharanja (soling) under floor.
91
-
1838
... More
Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.(FOOTING)
228.2
-
220
... More
Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Cold twisted bars
4000
-
64.2
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20
mm nominal size) coloumn
3.31
-
6780
... More
construction of samudaik bhawan ward no 24 Neemkathajna
-
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) footin
13.79
-
6270
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas,
lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement:M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix)
26.93
-
7030
... More
Brick work with bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
54.39
-
5750
... More
Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)Area of each slab 900 to 2000 sqcm
139.88
-
1299
... More
P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc completeSize 450 mm X 450 mm
20
-
1435
... More
construction of samudaik bhawan ward no 24 Neemkathajna
-
-
-
... More
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure30 mm thickDecorative teak veneer both side
6.3
-
2815
... More
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275gm/m
-
-
843
... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
300
-
117.5
... More
Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix:1:4 (1 cement : 4 fine/ coarse sand)
479.2
-
204.5
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer.
479.2
-
125
... More
Providing and fixing GI wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary M.S. strip beading 20x3mm with suitable screw at not exceeding 150mm distance etc. complete.
10
-
595
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10
-
161.5
... More
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter
10
-
303
... More
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single push fit Coupler : 110 mm
1
-
175
... More
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete
3
-
145
... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primerUsing M.S. angels 40x40x6 mm for diagonal braces.
1.8
-
3695
... More
construction of samudaik bhawan ward no 24 Neemkathajna
-
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge15 mm nominal outer dia .Pipes
10
-
224
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge25 mm nominal outer dia .Pipes
10
-
347
... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall25 mm dia. nominal bore
2
-
354.5
... More
Providing and fixing brass stop cock of approved quality15 mm nominal bore
2
-
333
... More
Providing and fixing uplasticised PVC connection pipe with brass unions 30 cm length 15 mm nominal bore
2
-
50.3
... More
construction of samudaik bhawan ward no 24 Neemkathajna
-
-
-
... More
Providing and fixing uplasticised PVC onnection pipe with brass unions 30 cm length 20 mm nominal bore
2
-
60.3
... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
2
-
666
... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
2
-
509
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level1:2:4 (1 Cement : 2 fine/ coarse sand : 4 graded stone aggregate 20 mm nominal size).
1
-
5360
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1
-
2620
... More
Providing and fixing white vitreous china quatting plate urinal with integral rim longitudinal flush pipe
1
-
2635
... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings completeSemi rigid pipe32 mm dia
1
-
64.6
... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
1000
-
8.8
... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of
standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading
and other fittings exceptnecessary hinges or pivots complete as per approved design.
7.5
-
3560
... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
479.2
-
184.5
... More
Short point (up to 3 mtr.)
5
-
331
... More
construction of samudaik bhawan ward no 24 Neemkathajna
-
-
-
... More
Medium point (up to 6 mtr.)
5
-
577
... More
Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade(IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in
recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036
- 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring
accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
5
-
89
... More
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess