Local Self Government Department Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 19,880Document Cost
₹ 500Tender Fee
₹ 500
Summary
Supply And Fixing Silent Dg Set In Nagar Palika Niwai Office , Niwai.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_DLB_451097_1Tender No
20/2024-25NewaiTender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://https://lsg.urban.rajasthan.gov.in/content/raj/udh/lsg-jaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length) including cutting, welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect. (Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 80 mm dia
3
2514
7542
... More
Supply, installation and testing of metal flexible coupling (below) of following dia required for horizontal length more than 3 mtr.as per standard of guide line of D.G. set company complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 80 mm dia
1
14405
14405
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of
load and site requirement) 4 KV impulse withstand voltage, ISI
marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC
60947-2, low watt losses, trip free mechanisum , energy limiting of
class 3 as per IEC, minimum phase termination capacity of
35sq.mm. , conductor line load reversibility , IP 20 contact protection
and fitted in existing distribution board/sheets, minimum electrical
operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80
A & above rating including making connections, testing etc. as
required. OEM shall have submit NABL / CPRI / ERDA accrediated
lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer
Annexure 'A' attached with this BSR Single pole MCB 6 A to 32 A rating
10
192
1920
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed UnArrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -
I of 1.1 KV with H4- Grade electrolytic aluminium conductor
confirming to IS 8130 of purity 99.6 %, Inner / outer sheath
confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC
pipe/ open duct/cable trench / Cable tray (with cable tie) including
testing etc. as required of following size. OEM must have it's own in
house NABL accrediated Laboratory for testing procedure as per
IS:10810. For additional technical parameters of product / work refer
Annexure 'A' attached with this BSR 25.0 Sq. mm 3.5 core
90
262
23580
... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993,
wall/ free standing floor mounted dust and vermin proof
compartmentalised cubical panel as specifications and Other
parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as
below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley
compartments having concealed hinged type doors with key type
lock with / without detachable extension type structure. Removable
3 mm. thick sheet steel gland plates with appropriate size of
knockouts for cables shall be provided
(b)complete panel shall undergo a process of degreasing, Water
rinsing, Activation, derusting, pickling in acid bath, phosphatising &
shall be subjected to nine tank process and then Powder coated with
approved shade of minimum 70 microns on both side of panel. The
panel having PE foam/ Neoprene rubber gasket of not less than
3mm thickness ,required hardware , concealed hinged door with key
type locking arrangement for equipment/switchgear earthed with 2.5
sq.mm braided copper wire.
[c) Interconnection between bus bar and switchgears /cable shall
be rigidly supported and made out by flexible copper wires (up to 63
amp ) and by solid bus bar (63 amp ) . control wiring will be carried
out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5
sq.mm flexible copper wire only. All joints / interconnections of
copper bus bar shall be dully tinned . Clearance between main bus
bar and risers / metal parts shall be at least 10 mm additional to
width of bus bar Bus bar is insulated by Heat Shrinkable sleeves .
Earth and Neutral bus bar shall be half of the size of phase bus bar.
( Cost of Bus bar / Flexible wire for Interconnection between Main
busbar and Switchgear is to be Paid Extra )
(d)Wiring between components within switchgear and Incoming /
outgoing cable shall be done through the terminal block only. Direct
connection shall not be permitted. Each terminal block shall be one
piece moulded, barrier type, 650 volt grade, complete with washers,
heads, studs with two nuts and identification strips and shall have
adequate continuous current rating. For tap-offs, adjacent terminals
with shorting strips shall be used. 10% Spare terminal blocks shall
be provided. Wire identification on marking strip shall correspond to
the designation of the wiring diagrams. All wire terminals on the
equipment shall also be marked with designation corresponding to
those of the wiring diagram.
(e)All wiring shall be enclosed in plastic channels and neatly
bunched and closed in metering chamber, Wiring between terminals
of various devices shall be ‘point to point’ (no wire splitting or teeconnections) with wires neatly trucked along the back of the panels,
adequately supported to prevent sagging.
(f)Floor mounted panel shall be mounted on Base frame of ISMC
channel size 100 x 50 x 5 mm ( to be paid Extra )
(g) Tests: The insulation resistance (with 1000 V Megger) and High
voltage Power frequency test (by applying a voltage of 2.5KV for one
minute) shall be measured between phases, between phase and
neutral and between phase and earth. both before and after high
voltage power frequency test. The insulation resistance shall not be
less than three megaohm. CT Secondary current injection test shall
also be carried out.
(h) only outer surface area on all sides shall be measured & panel to
be fabricated only from CPRI approved fabricator only (CPRI Test
certificates to be submitted)All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer
Annexure "A" attached with this BSR .
3
6124
18372
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of
load and site requirement) 4 KV impulse withstand voltage, ISI
marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC
60947-2, low watt losses, trip free mechanisum , energy limiting of
class 3 as per IEC, minimum phase termination capacity of
35sq.mm. , conductor line load reversibility , IP 20 contact protection
and fitted in existing distribution board/sheets, minimum electrical
operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80
A & above rating including making connections, testing etc. as
required. OEM shall have submit NABL / CPRI / ERDA accrediated
lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer
Annexure 'A' attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 40 A rating
6
1782
10692
... More
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of
size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the
ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including
all accessories like nut, bolts, reducer, nipple, wire meshed funnel,
and Heavy duty weather proof poly-propylene earth pit chamber with
lockable Jam free lid suitable for safe working load 5000 Kg or more
of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and
Height 250 to 300 mm. and embodying the pipe complete with
alternate layers salt and coke/ charcoal, testing of earth resistance
for value of 5 ohms or less as required & must record by engineer
in-charge during site visit and ensure to enter in measurment
book.All as per pre approved by Engineer in-charge. For additional
technical parameters of products/ work , refer Annexure "A"
attached with this BSR .
2
5876
11752
... More
Supply and Fixing GI flat (25x6mm) Strip. Having width- 25mm,
Thickness- 6mm, Material- Hot dipped Galvanized Iron, Coating
thickness- Avg. 70 microns. & Complied as per IEC 62561-2 GI strip
holder of material- Dow moulded compound, at spacing of 0.5 Mtr.
having height- 19mm, Slot Size- 25x6 mm Etc. as required.All as per
pre approved by Engineer in-charge. For additional technical
parameters of products/ work , refer Annex ure "A" attached with
this BSR .
6
373
2238
... More
Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.Depth upto 1.5 m
15
229
3442.5
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size).
7
4575
32025
... More
Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand)
15
4860
72900
... More
Brick work with bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6
3
6300
18900
... More
Providing and laying damp-proof course with cement concrete grade M-15 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by
weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar. 50mm thick.
9.45
445
4205.25
... More
Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar 1:4 (1 cement : 4 fine/ coarse sand)
52.5
227
11917.5
... More
Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km)
50
178
8925
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%