Jodhpur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jodhpur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 7,72,758 
Notes
Download

Costs

  • EMD

    ₹ 15,455
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Summary

Erection Of 33 Kv Line 1 Km And Construction Of 33 Kv Sub Station At Kanasariya And Erection Of 11 Kv Line 6.5 Km For Interconnection At Kanasariya Under Bap Sub Division Under Phalodi Circle

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(2.3)Excavation of pit in Hard Soil ( Where blasting is not required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit

-

-

-

... More
9 Mtr/ 1.2mx0.6mx1.50 m deep

44

-

13807.64

... More
(2.5)Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms .Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.

-

-

-

... More
Hard /dense soil

24

-

2268.72

... More
2.6 Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement:5 sand:10 aggregate mix.

8.66

-

25199.21

... More
2.7 Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.

60.84

-

9580.47

... More
2.8 Cement concrete flooring grade 1:2:4 (1-cement :2- coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc. complete

-

-

-

... More
75 mm thick with 20 mm thick nominal size aggregate.

31.68

-

15508.31

... More
2.11.1 Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.

22.5

-

53147.25

... More
3.1 Safe carriage of PCC poles including loading / un-loading

-

-

-

... More
a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole

-

-

-

... More
Within 10 Kms.

8

-

2275.04

... More
Within 10 Kms.

8

-

932.64

... More
a) 9 Mtr. Long-200 Kg PCC pole

-

-

-

... More
Within 10 Kms.

36

-

8591.04

... More
Within 10 Kms.

36

-

4196.88

... More
3.2 Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
Within 10 Kms.

1.65

-

659.75

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

1.65

-

186.52

... More
3.3 Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
Within 10 Kms.

2.59

-

1240.48

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

2.59

-

353.3

... More
3.5Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site (These charges will be 1.5 times for both sides )

-

-

-

... More
Within 10 Kms.

1

-

328.69

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

1

-

166.62

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.

22

-

76238.58

... More
Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.

4.5

-

17450.51

... More
Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.

21

-

1210.23

... More
Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 2 nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.

45

-

1857.6

... More
Fixing of 33kv pin insulator with pins.

12

-

218.88

... More
6.16 Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(B)G.O. switch . without earthing blade.

-

-

-

... More
33kv G.O.switch

2

-

2729.94

... More
11kv G.O.switch

7

-

7431.34

... More
6.17 Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33kv Horn Gap fuse set.

2

-

1258.68

... More
11kv Horn Gap fuse set.

6

-

3276.18

... More
6.19 Installation of lightening arrestors on erected structure /support (1 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(A)sub-station type

-

-

-

... More
33 KV L.A.(each)

9

-

1888.02

... More
11 KV L.A. .(each)

15

-

2730

... More
6.20Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of steel structure set for sub-station as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
25 and 40 KVA

1

-

762.08

... More
Installation of LT MCB (Distribution Box) on sub -station structure .The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,including connection on both ends with suitable lugs duly crimped (lugs & cable will be supplied by Nigam)

1

-

145.68

... More
Fixing of PG clamp of Weasel /Rabbit Conductor

138

-

840.42

... More
8.3Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:

-

-

-

... More
8.3.1 Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width

-

-

-

... More
Ordinary rock ( where blasting is not required.)

98

-

35969.92

... More
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

200

-

6314

... More
Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

100

-

4754

... More
8.3.4 Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:

-

-

-

... More
Where drilling is not required

30

-

7006.5

... More
Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.

150

-

943.5

... More
Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

100

-

876

... More
Earthing of new 33/11 KV S/S with bentonite compound (including material ) involving following activities.

1

-

6941.8

... More
10.2Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station.The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6.The charges for muffing will be paid extra as per chapter no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long 400 KG

44

-

22083.6

... More
10.3Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
ACSR DOG/RABBIT

800

-

23040

... More
11.1 Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
33 KV VCB

2

-

12305.96

... More
11 KV VCB

6

-

36917.88

... More
14.2Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing.

-

-

-

... More
Other steel items

2

-

10867.78

... More
Supply of M.S. Nut & Bolts

200

-

18308

... More
Part (B) Labour Charges for 33 KV Line 1 Km

-

-

-

... More
Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.

1

-

245.17

... More
Trimming of tree branches/plants manually/ by machine and preparing route approchases for proposed line/line maintenance work of existing HT/LT lines.

60

-

2207.4

... More
(2.3)Excavation of pit in Hard Soil ( Where blasting is not required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit

-

-

-

... More
9 Mtr/ 1.2mx0.6mx1.50 m deep

16

-

5020.96

... More
(C)Stay set/Depth of pit

-

-

-

... More
8'x 3/4" -0.75x0.5x1.6 m

24

-

6846.72

... More
3.1 Safe carriage of PCC poles including loading / un-loading

-

-

-

... More
a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole

-

-

-

... More
Within 10 Kms.

16

-

4550.08

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

16

-

1865.28

... More
3.2 Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
Within 10 Kms.

2.5

-

999.05

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

2.5

-

282.6

... More
3.3 Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
Within 10 Kms.

1.5

-

718.43

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

1.5

-

204.62

... More
5.2Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (400 Kg)

14

-

7729.54

... More
5.3Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of complete steel structure for line D.P.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long (400 Kg)

1

-

1592.62

... More
5.4 Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire

-

-

-

... More
8"x3/4" with 7/8 SWG stay wire

24

-

8211.6

... More
Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.

24

-

1383.12

... More
Fixing of 33kv pin insulator with pins.

48

-

875.52

... More
6.16 Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
Fixing of Danger Plate on supports/Structure

18

-

109.62

... More
7.3Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
G.I.Earth wire 6 SWG

1

-

1097.36

... More
7.1 Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
ACSR DOG

3

-

9514.11

... More
Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod 20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discom store issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

18

-

7404.84

... More
15.23 Fixing of extension pieces/ brackets for raising of pole height including fixing of pin insulators with pins & rebinding etc.

-

-

-

... More
33 KV line

2

-

744.08

... More
Supply of M.S. Nut & Bolts

25

-

2288.5

... More
Part (C) Labour Charges for 11 KV Line 6.5 Km

-

-

-

... More
Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.

6.5

-

1593.61

... More
Trimming of tree branches/plants manually/ by machine and preparing route approchases for proposed line/line maintenance work of existing HT/LT lines.

210

-

7725.9

... More
(2.3)Excavation of pit in Hard Soil ( Where blasting is not required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit

-

-

-

... More
9 Mtr/ 1.2mx0.6mx1.50 m deep

110

-

34519.1

... More
(C)Stay set/Depth of pit

-

-

-

... More
6'x 5/8" -0.75x0.5x1.35 m

80

-

20539.2

... More
3.1 Safe carriage of PCC poles including loading / un-loading

-

-

-

... More
a) 9 Mtr. Long-200 Kg PCC pole

-

-

-

... More
Within 10 Kms.

110

-

26250.4

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

110

-

12823.8

... More
3.2 Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
Within 10 Kms.

4.5

-

1798.29

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

4.5

-

508.7

... More
3.3 Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
Within 10 Kms.

1.87

-

895.64

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.

1.87

-

255.09

... More
5.2Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (200 Kg)

96

-

44640.96

... More
5.3Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long (200 Kg)

14

-

18984.28

... More
5.4 Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire

-

-

-

... More
6'x 5/8" -0.75x0.5x1.35 m

80

-

23690.4

... More
Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.

96

-

2629.44

... More
Fixing of 11kv pin insulator with pins.

288

-

3507.84

... More
7.1 Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
ACSR Weasel

19.63

-

31625.3

... More
15.23 Fixing of extension pieces/ brackets for raising of pole height including fixing of pin insulators with pins & rebinding etc.

-

-

-

... More
11 KV line

10

-

2923.5

... More
Other steel items

2

-

10867.78

... More
Supply of M.S. Nut & Bolts

200

-

18308

... More
Note-1.Dismentaling, if any: Dismentaling charges for all the items will be 60% of item rates of erection charges. However, charges for transportation of the material from works site in the Nigam/sub division store shall be paid as item rate of that material(Chapter-III, Transportation of material). The payment will be made after issuance of certificate by Engineer In Charge that all the dismentaled material has been safely received in the Nigam/sub division store Note-2. The nut & bolts will be provided/supplied by the contractor which will confirm to relevant ISS & payment will be made as per prevailing Discom store issue rate. Note-3. The quality of material supplied by the contractor be got checked & approved by the circle SE. Note-4. In case of pole upper end of the GI wire provided for earthing shall be bolted with cross arm. Note-5. The qty mentioned for normal soil/ordinary rock. Hard soil which does not required drilling and Hard Rock/ CC road which required drilling are tentative & shall be payble as per actual site condition and due verification by Engineer In Charge. Note-6. Safe Carriage of PCC poles/other material including Loading/un-loading as per actual distance of work-site from place of lifting & shall be payble as per actual distance and due verification by Engineer In Charge. Note-7. Unit rates are exclusive of GST and shall be paid extra if applicable. Note-8. The work should be carried out as per specification and standard measurement of Jodhpur Discom.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.