Jodhpur Vidyut Vitran Nigam Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jodhpur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Jan 2025
Closing Date5 Mar 2025
Tender Amount₹ 15,00,000 
Notes
Download

Costs

  • EMD

    ₹ 30,000
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 590

Summary

Construction Of Cattle Catcher,raising Of Boundary Wall Of Acos And Other Development At Circle Office Premises Jalore

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Randam Rubble stone masonary with hard stone in super structure above plinth level & upto five level for walls upto 30cm or less in thickness in cement sand mortar 1:6 (B-69/6.2.6+6.3.4)

60

3665

219900

... More
Randam Rubble stone masonary with hard stone in super structure above plinth level & upto five level for above 30 Cm thick walls in CM 1:6. (B-69/6.2.6)

4

3479

13916

... More
Add exra for facing as per design & detailled specification including additional cost of stone for Course Rubble Facing Second Sort.(B-70/6.4.2)

80

491

39280

... More
Add extra for Randam Rubble stone masonary with hard stone in Square or Rectangular Pillars. (B-69/6.3.1)

4

173

692

... More
Providing & laying in position specified grade of cement concrete for all RCC structural elements up to plinth level including curing, compaction, finishing with rendering in CM 1:3 & making good the joints & cost of plastizers (if required) excluding the cost of centering, shuttering & reinforcement. M-20 Grade. Nominal/Design Mix. (B-59/4.1)

20

4934

98680

... More
Providing & laying in position specified grade of cement concrete for RCC structural elements up to five level including curing, compaction, finishing with rendering in CM 1:3 & making good the joints & cost of plastizers (if required) excluding the cost of centering, shuttering & reinforcement for Beams, suspended floors,roofs, landings, balconies, shelves, chhajjas, lintels, staircases etc. M-20 Grade. Nominal/Design Mix. (B-59/4.3)

17

5185

88145

... More
Centering & Shuttering with plywood or steel sheets including strutting, propping, bracing bothways & removal of formwork for Foundation, footings, srap beams, rafts, bases of columns etc. (B-61/4.9)

15

157

2355

... More
Centering & Shuttering with plywood or steel sheets including strutting, propping, bracing bothways with steel props & removal of formwork up to floor five level for suspeded floors, roofs, landings, balconis, girders, cantilevers, sills, chhajjas, lintels, beams, plinth beams etc.(B-61/4.10.2)

111

340

37740

... More
Providing & Fabricating steel reinforcement for RCC work including straightening, cutting, bending, placing in position & binding (incl. cost of binding wire).All complete upto floor five level. Cold twisted deformed bars. (IS:1786). (B-62/4.13.1)

3000

77

231000

... More
P & L in cement concrete including curing,compaction etc. complete in retaining walls, return walls, walls including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, fillets, levelling course etc upto floor five level excluding the cost of C& S. M-15 Grade Nominal Mix 1:2:4.(B-55/3.2.2)

1

5112

5112

... More
Plaster on new surface on walls in CM 1:6 including racking of joints etc. complete fine finished. 25 mm thick. (B-139/12.3.1)

100

211

21100

... More
Plaster on new surface on walls in CM 1:4 including racking of joints etc. complete fine finished. 25 mm thick.(B-139/12.2.1)

14

227

3178

... More
Pointing on stone masonary in CM 1:3.Flush/ Ruled/ Struck or Weathered Pointing.(B-143/12.31.1)

370

124

45880

... More
P & F precast CC coping 1:2:4 mix 50mm thick complete as per specification.(B-56/3.8)

150

367

55050

... More
Cement Concrete flooring 1:2:4 finished with a floating coat of neat cement including cement slurry, making of lines or grooves etc. complete but excluding the cost of nosing of steps etc. complete. 75 mm thick with 20 mm thick nominal size aggregate. (B-128/11.3.2)

17

458

7786

... More
Structural steel work riveted, bolted or welded in built up sections, trusses & framed work including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer all complete. (B-98/9.2)

320

81

25920

... More
P & F G.I. Barbed wire of size 2.5x2.0 mm fixed with G.I. staples etc. (B-103/9.33+9.35)

1000

12

12600

... More
Providing & Laying of Paver blocks as per IS:15658:2006 (Indian standard for precast concrete block for paving specifications) & IRC: SP63-2004 (Guidelines for the use of interlocking concrete block pavements). M-40, 80 mm thick to be used in medium traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight or an equivalent of 0.50 to 2.0 MSA for a design life of 20 years) like City streets, small & medium market roads, low volume roads, utility cuts on arterial roads etc. Category-C not denated on any of it's faces like Hexagonal, rectangular, square shape as per IRC: SP63-2004. (B-135,136/11.38.2(C))

215

1003

215645

... More
P & L cement concrete Kerb Stones of different sizes in M-30 Grade (Manufactured with fully mechanised dry cast process with firced action mixer whose arms revolve along the main axis & rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concrete mix. Manufactured with steel moulds (Milled & manufactued in CSI diamond or CSI Nitro process for accuracy) on steel base of min 16 mm thick, having vibration & pressing action both together with the help of multiple synchronised vibrators. Power of hydraulic station should be min 50 KW for compaction & curved in controlled chambers having humidity control & automated air circulation system in position to the required line, level & curvature jointed with CM 1:3 including making of joints, drainage opening wherever required. (B-208/17.21)

5

9429

47145

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding. New work (two or more coats) over and including scrapping and priming coat with cement primer. (B-144/12.37.1)

1000

75

75000

... More
Finishing wall with water proofing cement paint of approved brand & manufacture & or required shade to give an even shade including all scaffolding. New work (Two or more coats applied @ 3.84 Kg/10 Sqm). (B-145/12.41.1)

1000

53

53000

... More
Painting with synthetic enamel paint of approved brand & manufacture to give an even shade.Two or more coats on New work.(B-146/12.46.1)

400

69

27600

... More
P & F WVC Wash Basin (1st quality, IS:2556 Mark) of approved make with C.I. brackets duly painted, 1No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall of size 510x440 mm.(BS-221/1.36.2)

1

2408

2408

... More
P & F Chlorinated Poly Vinyl Chloride (CPVC) pipes (IS:15778:2007 code) having thermal stability for hot & cold water supply including all CPVC plain & Brass threaded fittings including fixing the pipe with clamps at 1 meter spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete as per directions of Engineer In Charge. (Concealed work including cutting chases & making good the walls etc.). 15 mm Nominal size. (BS-240/2.38.1)

20

279

5580

... More
P & F Chlorinated Poly Vinyl Chloride (CPVC) pipes (IS:15778:2007 code) having thermal stability for hot & cold water supply including all CPVC plain & Brass threaded fittings including fixing the pipe with clamps at 1 meter spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete as per directions of Engineer In Charge. (Concealed work including cutting chases & making good the walls etc.). 25 mm Nominal size. (BS-240/2.38.3)

15

376

5640

... More
P & F Chlorinated Poly Vinyl Chloride (CPVC) pipes (IS:15778:2007 code) having thermal stability for hot & cold water supply including all CPVC plain & Brass threaded fittings, this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per directions of Engineer In Charge. (External work) . 15 mm Nominal size. (BS-240/2.39.1)

150

167

25050

... More
P & F Bib Cock (IS:8931 Mark) Superior quality of approved make C.P. Brass Bib Cock 15 mm. (B-232/2.7.3)

3

590

1770

... More
P & F Inlet Connection (Angle Valves) Superior quality of approved make for Wash Basin, Gyser etc. C.P. Inlet Connection 15mm Brass. (IS:8931 marked. (B-233/2.12.1)

1

501

501

... More
P & F 15 mm dia. Connection pipe of approved quality/make. PVC pipe with C.P. Brass nuts up to length 450 mm. (B-233/2.13.3)

1

101

101

... More
P & F Full-way (IS:778 Mark) or Wheel valve of approved make : Gun-metal 15 mm nominal bore. (B-233/2.15.1)

1

227

227

... More
P & F Full-way (IS:778 Mark) or Wheel valve of approved make :Gun-metal 25 mm nominal bore. (B-233/2.15.3)

1

529

529

... More
P & F PVC Storage Tank ISI Marked (IS:12701, Indicating BIS license No.) of approved make with cover, 25 mm dia. 1 M long G.I. over flow pipe & 25 cm long wash out pipe with plug & socket, including making connection etc. complete of approved design. 500 litres capacity. (B-236/2.26.3).

2

3920

7840

... More
P & F Unplasticized Poly Vinyl Chloride (UPVC) SWR pipes type 'B' for sciland waste discharge system (IS:13592:1992 Marked) of approved quality/make. 75 mm Dia. (B-257/3.44.1)

10

167

1670

... More
P & F Unplasticized Poly Vinyl Chloride (UPVC) SWR pipes type 'B' for sciland waste discharge system (IS:13592:1992 Marked) of approved quality/make. 110 mm Dia. (B-257/3.44.2)

25

336

8400

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Short point (up to 3 mtr.) E-01/1.1.1

8

359

2872

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Medium point (up to 6 mrt.) E-01/1.1.2

8

578

4624

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Long point (up to 10 mrt) E-01/1.1.3

8

772

6176

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. On board E-02/1.3.1

5

357

1785

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. E-07/7.37

2

580

1160

... More
P & F of IK08, IP-66 protected LED street light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast Aluminium material with heat dissipation fins on housing with UV stabilized PC (UV stabilization report submitted for UV cover)/Toughened Glass cover & secondary lens on each LED & should be SMD type of 3 to 5 watts each. The System efficiency =125 lm/wt & potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High, THD(I)10%, Humidity 10% to 90% RH Working Temp - 5 C to 45 C. Driver current 750 mA. The luminaire with Minimum 70% lumen maintened, CRI70 & CCT 5700K +355K. Surge protection shall be min=4 KV internal & min 10 KV external inside driver compartment, driver should be Phase to Phase protection of 440 V for 4 Hrs. Manufactures word Mark/Namr Engraved/Embossing on die cast housing to allow traceabulity/Authenticity. Fixture shall be as per IS:10322 compliance. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/Report with liable Warrenty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer In Charge. For additional technical parameters of product/work refer Annexure-A attached with this BSR. LED Street Light fixture with Minimum Lumen output 5600 lm. (E-18/18.12.3).

4

4145

16580

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E-14/73/14.1

1

3643

3643

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6 A to 32 A rating E-06/17/6.1.1.2

4

187

748

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 40 A rating E-06/17/6.1.1.3

2

415

830

... More
P & F ISI marked 32 A D.P. switch with fuse & indicating lamp including making connections, testing etc. as required.Group-2. (E 072300)

1

76

76

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1170mm (+/-10%) LED batter with min. lumen output 2200 lm E-17/87/17.1.1

8

492

3936

... More
Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD 20% ,p.f.≥0.95,CRI 80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 600mm , Min Lumens output 1800 lm LED Tube rod with Polycarbonate housing E-17/87/17.2.1

8

202

1616

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10 SWG G.I. (Hot Dipped) wire E-14/75/14.6.9

8

14

112

... More
Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .E-07/30/7.21

8

219

1752

... More
SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 0.5 HP E-21/115/21.7.1

1

10730

10730



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.