Jodhpur Vidyut Vitran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 16,502Document Cost
₹ 2,950Tender Fee
₹ 590
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JdVVN_423013_1Bid Award Id
ViewTender No
TNDC 53Tender Authority
Jodhpur Vidyut Vitran Nigam Limited ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Trimming of tree branches and preparing route approaches for the purposed line
10
311
31.18
(2.4)Excavation of pit in Hard Rock
-
-
-
9 Mtr/ 1.2mx0.6mx1.50 m deep
-
-
-
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
36
35892
997.02
(2.5)Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms .Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.
-
-
-
Hard /dense soil
12
961
80.11
(2.6) Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement:5 sand:10 aggregate mix.
4.33
10677
2465.97
(2.7) Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.
60.84
8119
133.45
2.8 Cement concrete flooring grade 1:2:4 (1-cement :2- coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc. complete
-
-
-
75 mm thick with 20 mm thick nominal size aggregate.
31.68
13142
414.86
2.11.1 Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.
22.5
45040
2001.78
(3.1) Safe carriage of PCC poles including loading / un-loading
-
-
-
a) 9 Mtr.long 400 Kg. PCC pole
-
-
-
Within 10 Kms.
8
1928
241
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
8
395
49.4
c) 9 Mtr.long 200 Kg. PCC pole
-
-
-
Within 10 Kms.
28
5662
202.24
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
28
1383
49.4
(3.2) Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
-
-
-
Within 10 Kms.
5.42
1835
338.66
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
5.42
259
47.9
(3.3)Safe Carriage of insulator, hardware, cable etc. including loading/unloading and stacking in Nigam stores etc.
-
-
-
Within 10 Kms.
1.37
556
405.89
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
1.37
79
57.8
(3.5)Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site (These charges will be 1.5 times for both sides )
-
-
-
Within 10 Kms.
1
248
248.04
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
1
141
141.2
(5.6) Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
11
32304
2936.77
(5.8)Fixing of all type of fabricated material on erected support with nut & bolts as per approved design & drawing of sub-station.
4.5
14788
3286.35
(6.9)Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.
72
3516
48.84
Fixing of 33kv pin insulator with pins.
6
92
15.46
(6.16) Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
-
-
-
33 kv G.O.switch
1
1156
1156.75
11kv G.O.switch
10
8996
899.68
6.20Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of steel structure set for sub-station as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,
-
-
-
25 and 40 KVA
1
645
645.83
Fixing of PG clamp of Weasel /Rabbit Conductor
60
309
5.16
Earthing of 11/0.4 KV distribution transformer/sub station with 3 pieces of MS rod 20 mm dia each 0 meter lond and driving ther into earth
15
3504
233.6
(8.3)Mesh earthing for 33/11 kv sub-station as per approved map &design uslngMS flat 50X6mm/MS road 20mm dia Includinglaylng of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:
-
-
-
(8.3.1)Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width
-
-
-
Hard rock ( where blasting is required.)
180
166032
922.4
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.
200
5350
26.75
Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.
100
4029
40.29
8.3.4 Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:
-
-
-
Where drilling is not required
30
5937
197.92
Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.
150
799
5.33
Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.
100
742
7.42
Earthing of new 33/11 KV S/S with bentonite compound (including material ) involving following activities.
1
5882
5882.88
10.2Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station.The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6.The charges for muffing will be paid extra as per chapter no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates.
-
-
-
PCC Poles 8 Mtr. Long 200 kg
-
-
-
PCC Poles 9 Mtr. Long 200 kg
28
11909
425.34
PCC Poles 9 Mtr. Long
8
3402
425.34
10.3Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.
-
-
-
ACSR DOG/RABBIT
400
9764
24.41
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)
-
-
-
On new surface
175
5909
33.77
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)
-
-
-
On new works with two coats.
175
8863
50.65
(14.2)Fabrication of Steel structures of.M.S. Channels, MS Angel & M.S.Flat including cutting drilling and continious welding joints as per drawing and design.
-
-
-
Other steels items
1
4604
4604.99
Supply of MS nuts & bolts
200
15518
77.59
Erection of 11 kv line
-
-
-
Conducting route survey as per approved map and pegging of reoute with section point/double location
8.36
1735
207.77
(3.3)Safe Carriage of insulator, hardware, cable etc. including loading/unloading and stacking in Nigam stores etc.
-
-
-
Within 10 Kms.
3.14
1274
405.89
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
3.14
181
57.8
(20.2)Laying of two (D/C) 11 KV, XLPE, Cable (Al. conductor) underground cable w/o overlapping as per relevant IS/JdVVNL standards including excavation of 50 cm width x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
-
-
-
a) 3x35 Sq mm to 3x185 Sq mm
1570
273195
174.01
(20.3) Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required
-
-
-
A) (I) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm
16
17187
1074.23
C) (I) Straight through joint 3x35 to 3x185 Sq mm
8
17902
2237.83
(11.11) Providing and fixing of G.I. Pipe B-Class(IS:1239 marks) at the starting and finishing point of 33 & 11 KV under ground cable and to lay & clamp vertically with the existing support including labour charges
-
-
-
Providing and fixing of G.I. Pipe B-Class(IS:1239 marks) at the starting and finishing point of 33 & 11 KV under ground cable and to lay & clamp vertically with the existing support including labour charges
48
68654
1430.31
Note-1.Dismentaling, if any: Dismentaling charges for all the items will be 60% of item rates of erection charges. However, charges for transportation of the material from works site in the Nigam/sub division store shall be paid as item rate of that material(Chapter-III, Transportation of material). The payment will be made after issuance of certificate by Engineer In Charge that all the dismentaled material has been safely received in the Nigam/sub division store Note-2. The nut & bolts will be provided/supplied by the contractor which will confirm to relevant ISS & payment will be made as per prevailing Discom store issue rate. Note-3. The quality of material supplied by the contractor be got checked & approved by the circle SE. Note-4. In case of pole upper end of the GI wire provided for earthing shall be bolted with cross arm. Note-5. The qty mentioned for normal soil/ordinary rock. Hard soil which does not required drilling and Hard Rock/ CC road which required drilling are tentative & shall be payble as per actual site condition and due verification by Engineer In Charge. Note-6. Safe Carriage of PCC poles/other material including Loading/un-loading as per actual distance of work-site from place of lifting & shall be payble as per actual distance and due verification by Engineer In Charge. Note-7. Unit rates are exclusive of GST and shall be paid extra if applicable. Note-8. The work should be carried out as per specification and standard measurement of Jodhpur Discom.
-
-
-