Jodhpur Development Authority Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 57,800Document Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JDAJO_426553_1Bid Award Id
ViewTender No
JoDA/Nit-03/Elec-II/2024-25Tender Authority
Jodhpur Development Authority ViewPurchaser Address
-Website
http://https://urban.rajasthan.gov.in/joda
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Regularly Operation & maintenance of electronics pole mounting dusk down photo cell timer, clock type timer, ON-OFF panel 63/100amp rating Main switch. By required replacement all defective accessories which are bumet, broken and missing such as air break, contractor, (L&T/BCH male) 3 pole MCCB, single pole MCCB, solar plate, electronic/micro controller, copper strip lead wire insulator, hard ware. Upto supply sources. And also regularly maintain log sheet of time ON-OFF and must be intimate to site incharge/engineering incharge & if any type of need from JVVNL immediate to inform related office and any type required help to take them.
1) For 63/100 Amp rating (3-Phase) (12 Month)
15
-
-
Regularly Operation & Maintenance of manual main switch operated ON-OFF & inbcluding all need full replacement by defective, burnt, and broken accessories such as kitkat fuse, handle unclip fuse wire HRC fuse copper strip connecting rode etc. maintain log sheet and time to time intimate to site incharge/ engineer in charge & if any type of need from JVVNL immediate to inform related office and any tyupe required help to take them. 32 Amp. Switch/63 Amp. Switch/100 Amp. Switch/200 Amp. Switch (12 Month)
1
-
-
NOTE:-
1) OFF-ON must be timely SUNRISE/SUNSET if any special case as per direction by engineering incharge.
2) Authorised Working Supervisor and staff must be connectivity with zonal staff / JEN/AEN/XEN and available in prescribe working time.
3) Authorised worker and supervisor signing in register and take needful direction from engineering incharge for working.
4) Before starting work to inform to related JVVNL sub station and take needful safety direction and equipment and tools.
-
-
-
Regularly Operation & Maintenance of existing High mast lights (12.5/16/30 Mtr.High Power LED Flood Light 120W/160W/200W, 1 Navigation) & panel with replacement of defective accessories as per direction of engineering incharge (12 Month)
4
-
-
Regularly Operation & Maintenance of existing Semi High mast lights (High Power LED Flood Light 120W/160W) with replacement of defective accessories as per direction of engineering incharge (12 Month)
15
-
-
Immediate attend and take needful action on accidental pole within time as soon possible with all required labour, tools, vechiles as direction of engineering incharge.
5
-
-
Regularly Operation & Maintenance of existing LED lights (20-25 watt, 30-40 watt, 80-90 watt, 110-120 watt, LED Flood light & 40W/60W LED Post Top) with replacement of defective accessories as per direction of engineering incharge (12 Month)
200
-
-
Replacement of defective Driver in LED street light fixture (20-25 watt/30-40 watt/80-90 watt/110-120 watt).
5
-
-
Replacement of defective Surge protector in LED street light fixture (20-25 watt/30-40 watt/80-90 watt/110-120 watt).
5
-
-
Maintenance of C.C.T.V Camera With D.V.R., N.V.R. Unit, all respect for one year
1
-
-
SITC 2 MP Full HD WDR Bullet IP Camera: 1/2.8" 2 MP Progressive scan CMOS, Max. 25/30 fps@2MP (1920x1080), Supports starlight function, H.265 and H.264 triple-stream encoding, WDR (120dB), Day/Night (ICR), 3D-DNR, ROI, AWB, AGC, BLC, HLC, 2.7~13.5mm motorised lens,IR range of 60 Mtrs, IP 67, IK10, Micro SD Card, PoE, Smart Detection Tripwire, Intrusion, Video tempring , Alarm IN 1 Channel In : 5ma 5V DC, Alarm Out 1 Channel Out: 300ma 12V DC, Product should be UL, FCC, CE, ROHS Make: CP Plus/Sahun/ Bosch/ Pelco
3
-
-
SITC 8 Port Poe switch for site location 8x10/100/1000 POE + 2 Giga SFP uplink Port Make : CP/Dahua/Dink
2
-
-
Supply and drawing of ISI marked 2 coreX1.5 sqmm armoured power cable.Make:KEI/Polycab/Havells
500
-
-
Regularly Operation & Maintenance of existing LED shine board at At Ashok Udhyan As Per Requirment including replacement of defectives items like SMPS supply, LED Module, Driver etc.
12
-
-
SITC of Dome Camera, Video Resolution: 5MP, 3072x1728 Pixels @30 fps; Image Sensor: 1/2.8-inch CMOS; Built in Infra-Red: 15 mtr; High Dynamic Range- 120 dB WDR; Lense- 3.2 -10 mm, F1.6, FOV:89° (H) x 47° (V); Onvif Profile S,G,T Confirmant; UL Certified; Make: Avigilon, Bosch, Axis
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements