Jhalawar Medical College Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jhalawar Medical College - JMC Tender

Services
Healthcare and Medicine
Eprocure
Opening Date28 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

  • EMD

    ₹ 80,000
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Locking mechanism of the screws must be one step locking should block the screws from coming out.

1

-

-

... More
The thickness of plate must be 2.0mm OR less and width 16.5 mm.

1

-

-

... More
The core diameter of the screws must be 3mm with outer diameter being 4.0mm and 4.5mm.

1

-

-

... More
The plates must be available in all sizes. I level, II level, III level.

1

-

-

... More
All the screws must be colour coded and available in self tapping as well as self drilling options.

1

-

-

... More
Cervical Peek Cage

-

-

-

... More
The cage must be radiolucent with sharp teeth inter body fusion cage system of implants and instruments designed for anterior cervical interbody fusion (ACIF) and should be compatible with anterior cervical plating system (ACP).

1

-

-

... More
The cages must be Curved cages, which mimic the curvature of the healthy endplate.

1

-

-

... More
The cages must be Wedge-shaped cages, which match the flattened degenerated end plate.

1

-

-

... More
All implants must be 15mm wide and 12.5mm deep and are supplied sterile pre-packed.

1

-

-

... More
The available implant heights must be 5mm, 6mm, 7mm, 8mm, 9mm and 10mm.

1

-

-

... More
Expandable Cervical Corpectomy cages

-

-

-

... More
Expandable vertebral body replacements For Cervical & upper Thoracic (C3-T2) Spine

1

-

-

... More
Should have continuous expansion system so that height can be achieved

1

-

-

... More
Should have rapid & controlled in situ expansion

1

-

-

... More
Should have locking clip to secure the expanded implant to prevent micro movements.

1

-

-

... More
Should have foot print of 11.9 mm X 15.0 mm

1

-

-

... More
Should achieve height from 17mm to 70mm & angle from 4.5 to7 degree

1

-

-

... More
Should be made of medical grade titanium material

1

-

-

... More
Locking Cervical Cage With Plate

-

-

-

... More
Expandable vertebral body replacements cage with in built cervical plate for fixation in situ with in the system for Cervical & upper Thoracic (C3-T2) Spine.

1

-

-

... More
Should have continuous expansion system so that desirable height can be achieved

1

-

-

... More
Should have rapid & controlled in situ expansion with plate providing the option of rigid, toggling and hybrid construct

1

-

-

... More
The plates must be available in all sizes. I level, II level, III level.

1

-

-

... More
Should be made of medical grade titanium material

1

-

-

... More
Locking mechanism of the plate screws must be one step locking which should block the screws from coming out.

1

-

-

... More
The core diameter of the screws must be 3mm with outer diameter being 4.0mm and 4.5mm.

1

-

-

... More
All the screws must be colour coded and available in self tapping as well as self drilling options.

1

-

-

... More
Cervical Disc replacement

-

-

-

... More
Superior and inferior implant plate made of cobalt-chromium molybdenum alloy according ISO 5832-12.

1

-

-

... More
Plasma-sprayed titanium coating.

1

-

-

... More
Inlay made of ultra-high molecular weight polyethylene (UHMWPE)

1

-

-

... More
Ball and socket principal – Metal on polymer.

1

-

-

... More
Modular anatomical design.

1

-

-

... More
Optimal primary stability due to H keel anchorage of the a prosthesis in the vertebral body.

1

-

-

... More
Anatomical foot print design for maximum endplate coverage.

1

-

-

... More
Six different footprints available for optimal coverage of the vertebral end plate : M, MD, L, LD, XL, XLD.

1

-

-

... More
Three different heights (5, 6 and 7mm) allowing adjustments to the individual dimensions of the patient’s disc.

1

-

-

... More
Lumbar Disc Replacement

-

-

-

... More
Superior and inferior implant plate made of cobalt-chromium molybdenum alloy.

1

-

-

... More
Ball and socket principle- Metal on Polymer.

1

-

-

... More
Inlay made of ultra-high molecular weight polyethylene (UHMWPE)

1

-

-

... More
There must be Vacuum Plasma spray Coating

1

-

-

... More
There must be primary stability through central keel.

1

-

-

... More
Angulations selection must be from:

1

-

-

... More
Superior Plate : 3 °, 6° and 11°

1

-

-

... More
Inferior plate : 0°, 3° and 8°

1

-

-

... More
Combinations : 3°, 6°, 9°, 11°

1

-

-

... More
Posterior Cervical Fixation System (Lateral Mass Fixation System)

-

-

-

... More
The system should have cancellous bone and cortex screws.

1

-

-

... More
The system should have locking screws for angularly stable locking and fixation of the rod.

1

-

-

... More
The system must have self-tapping and self-drilling screws.

1

-

-

... More
The system must have 3.5mm Ti Rod.

1

-

-

... More
The system should have OC fusion option.

1

-

-

... More
The system should offer hooks.

1

-

-

... More
The system should have Cancellous profile bone screws : III. 3.5mm with 2mm increments.

1

-

-

... More
The system should have Cancellous profile bone screws : IV. 4.0 mm with 2mm increments

1

-

-

... More
The system should have Cortical profile bone screws :3.5mm with 2mm increments.

1

-

-

... More
The system should have Rod = 9mm.

1

-

-

... More
Shaft Screws should have 10mm unthreaded portion Rods : IV. 3.0mm , 3.5mm Ti Rod.

1

-

-

... More
Shaft Screws should have 10mm unthreaded portion Rods : V. 3.5mm / 5.0mm Ti Rod.

1

-

-

... More
Shaft Screws should have 10mm unthreaded portion Rods : VI. 3.5mm / 6.0mm Ti Rod.

1

-

-

... More
The system should have Transverse connector: 60mm and 75 mm.

1

-

-

... More
The system should have 3.5mm Ti Transverse Bar.

1

-

-

... More
The system should have Occipital Plate/Rods.

1

-

-

... More
Mesh Cage for vertebral body replacement The mesh cage must be available in the following specifications and must come along with press fit end rings:

1

-

-

... More
Mesh, round (for Cervical))

-

-

-

... More
10mm: heights 4-18mm

1

-

-

... More
12mm: heights 4-88mm

1

-

-

... More
15mm: heights 8-88mm

1

-

-

... More
Corresponding press fit end rings, round - Angles of 00 or 2.50 in 10, 12 and 15mm diameter options.

1

-

-

... More
Mesh, oblong (For thoracic and lumbar region) – - Angles of 00 or 2.50 in 10, 12 and 15mm diameter options.

1

-

-

... More
Mesh, oblong (For thoracic and lumbar region) – - Angles of 00 or 2.50 in 10, 12 and 15mm diameter options.

1

-

-

... More
Mesh, oblong (For thoracic and lumbar region) – Dimensions: 17X22mm, 22X28mm and 26X33mm – Heights: 6-88mm End Rings, oblong

1

-

-

... More
Angles of 00 or 50for the corresponding dimensions; 17X22mm, 22X28mm and 26X33mm.

1

-

-

... More
CV Junction fixation System (occiput to C2)

-

-

-

... More
The system should have medial and lateral plates of 50& 60mm, one & two hole clamps which must allow the medial and lateral rod placement, and should be able to give 15 degree of screw angulations.

1

-

-

... More
The system must have straight and pre contoured ‘3.5mm rods.

1

-

-

... More
The system should have blunt 4.5mm occipital screws Qrid 5mm emergency screws with 4-18mm lengths.

1

-

-

... More
The system should have screwdriver shaft stardrive T15, self holding, with cordan joint as well as straight, for Quick coupling.

1

-

-

... More
The system must have the templates of occipital plates to avoid wrong plate selection.

1

-

-

... More
The system should have simple locking mechanism of each screws.

1

-

-

... More
The system should have tap for better screw purchase and 2mm torque limiting screw driver for final tightening.

1

-

-

... More
Following components should be available in system : Occipital plate (t or y shaped)

1

-

-

... More
Following components should be available in system : Transverse Connector

1

-

-

... More
CV Junction fixation System (C1 to C2)

-

-

-

... More
The system should be versatile, must have set of 6 screws and two rods

1

-

-

... More
The system must have straight and pre contoured ‘3.5mm rods.

1

-

-

... More
Titanium made 3.5 mm diameter, polyaxial screw of different lengths from 12 mm to 36 mm length for posterior cervical fixation.

1

-

-

... More
The system should have tap for better screw purchase and 2mm torque limiting screw driver for final tightening.

1

-

-

... More
Joint spacer of various sizes made of titanium

1

-

-

... More
Zero profile anterior cervical interbody fusion devices

-

-

-

... More
The implant should act as stand alone interbody fusion device for cervical spine with the benefits of as interbody spacer and as anterior cervical plate.

1

-

-

... More
The implant must be a combination ‘of plate’ and space & where the plate must automatically align when inserted.

1

-

-

... More
The implant must have radio opaque marker for posterior visualization during imaging and teeth on superior and anterior surface for initial stability.

1

-

-

... More
Spacer Component must be made of PEEK optima (polyetherketone).

1

-

-

... More
The implant must have one step locking screw and screws should form a bone wedge with 40° 5° cranial/caudal angle with 2.5° medical lateral angle.

1

-

-

... More
The screw must come with self tapping and self centering options with titanium alloy material (Ti-6AI-7NB)

1

-

-

... More
The screws must come in 3.0mm diameter & must be colour coded by screw length varying from 12, 14 & 16mm.

1

-

-

... More
Implant’s triobular thread cutting flutes should be self centering.

1

-

-

... More
The implants must come in parallel lordotic and convex implants sets with heights varying from 5mm to 12mm with an increment of 1mm each.

1

-

-

... More
Odontoid Screw

-

-

-

... More
Screw should made up of Tianium Alloy (TAN).

1

-

-

... More
Screw should be Cannulated.

1

-

-

... More
Screw should be self-drilling.

1

-

-

... More
Screw should consist of 12mm short thread.

1

-

-

... More
Screw should be of 3.5mm Ø.

1

-

-

... More
Screw should be available in the length of 36mm to 50mm.

1

-

-

... More
The whole system should thus enable the following- Help in preservation of atlantoaxial mobility with lag screw compression technique.

1

-

-

... More
With wire guiding ensures precise positioning of Implants & instruments.

1

-

-

... More
Odontoid Screw

-

-

-

... More
Top loading pedicle screw and rod system for the posterior stabilization of the lower back.

1

-

-

... More
The pedicle screw system must have polyaxial as well as monoaxial head for case specific manipulation.

1

-

-

... More
The polyaxial head should offer 25 degree of angulations about the axis of the screw.

1

-

-

... More
The pedicle screw system must have dual core screws for rapid instertion and secure anchorage in both, cortical and cancellous bone.

1

-

-

... More
The screws must be colour coded

1

-

-

... More
Single step locking mechanism.

1

-

-

... More
The option of achieving case specific lordotic and parallel compression with the same system.

1

-

-

... More
Curved rods in 6mm diameter from length 70mm to 300mm.

1

-

-

... More
Straight rod in 6mm diameter from 80mm to 150mm.

1

-

-

... More
Screw dimensions should be 4.5mm, 5.5mm, 6.5mm diameter LENGTH 30mm, 35mm, 40mm, 45mm, 50mm.

1

-

-

... More
Monoaxial, Multiaxial and Reduction screws should be available. With provision of persuader for spondylo-listhesis reduction.

1

-

-

... More
Trans Foraminal Lumbar Interbody Fusion

-

-

-

... More
The cage must be radiolucent made up of PEEK – optima material with sharp teeth designed for Trans foraminal Lumbar Interbody Fusion (TLIF).

1

-

-

... More
The cage must have rounded tapering edges allowing easy insertion thus minimizing injuries to end plates and neural structures.

1

-

-

... More
The cage must have 3 titanium markers (Two lateral, one central) to indicate the cage position on x-ray.

1

-

-

... More
The cage must have injection moulded roughened surface promoting bone integration and on growth.

1

-

-

... More
The cages must have biconvex shape providing even distribution of compressive forces along the endplates thus stability.

1

-

-

... More
The cage must have one broad graft hole and two lateral holes.

1

-

-

... More
Implants must be available in two footprints sizes 10x27mm, 11mm, 12mm, 13mm, 15mm, 17mm.

1

-

-

... More
Posterior Lumbar Interbody Fusion

-

-

-

... More
The system should be able to provide: Adequate stability - Restores disc height - Restores Lordosis - Preserves the integrity of the vertebral body endplates - Provides an optimized fusion bed

1

-

-

... More
It should be radiolucent interbody fusion system of implants and instruments for posterior Lumbar Interbody Fusion (PLIF).

1

-

-

... More
Cage must be made of PEEK optima® material facilitating radiographic assessment of fusion.

1

-

-

... More
Cage must have two x-ray markers integrated into the cages to enable easy visualization of their position postoperatively.

1

-

-

... More
PEEK material used must contain no carbon fibres, thereby reducing the risk of systemic uptake and local inflammatory response.

1

-

-

... More
Cages must be available in 6 heights in 2 mm increments, and should be supplied sterile pre-packed.

1

-

-

... More
The optimal anatomical shape and supportive superior and inferior surface design of the cage should reduces the risk of subsidence into the adjacent vertebrae.

1

-

-

... More
The cage should have perforated structure which must allows for bony ingrowth through the cage and the design must ensures optimal implant-to-endplate contact.

1

-

-

... More
Cage must be designed for an optimal fit into the natural concavity between two adjacent vertebral bodies.

1

-

-

... More
Cage must have teeth on the superior and inferior surfaces providing additional primary stability.

1

-

-

... More
The cage must be injection moulded PEEK cage so that it has roughened surface, which is superior to a machined PEEK surface in that promotes bone integration and ongrowth.

1

-

-

... More
Anterior stabilization of thoracolumbar spine

-

-

-

... More
The implant should provide anterior stabilization to thoracolumber spine.

1

-

-

... More
The implant should provide the plate and rod construct and be designed to be used along with either bone graft or with a vertebral body replacement.

1

-

-

... More
The implant should come with instruments which are designed for use in open, minima-open or endoscopically assisted approaches.

1

-

-

... More
The implants should come with telescopic mechanism with the facility of in situ compression and distraction.

1

-

-

... More
The implants should comein the following sizes : Mono-segmental : 29-33 mm, 31-37mm, 35-45mm, 41-57mm Bi-segmental : 53-71mm, 66-86mm

1

-

-

... More
Height of the implant above bone without posterior locking screws should be 7.7mm and with posterior locking screws should be 9.0 mm and convergence of screws should be of 7.0°

1

-

-

... More
The posterior screws should be of 7.0 mm diameter, cannulated for use with k-wire, dual core and double lead.

1

-

-

... More
The implants should come with polyaxial bushings which allow an angulation of 15° for screw insertion tailored to the individual anatomical situation.

1

-

-

... More
Expandable Thoracic and Lumber Corpectomy cages.

-

-

-

... More
Expandable vertebral body replacements For Lumber & Lower Thoracic (T5- L4) Spine For mono, bi &trisegmental fusion Should have rapid & controlled in situ expansion. Should have ratchet system so that height can be achieved Should have foot print of 22 X 21 mm and 25 X 28 mm Should achieve height from 20mm to 73mm & angle from -5°, 0°, 10°, 20°, -6°. Should be in Titanium TAN alloy.

1

-

-

... More
Low Profile Neuro (Mini plates)

-

-

-

... More
A Plating systems to offer Neuro surgeons a choice do rigid fixations of craniotomies and other cranial procedures which should be very low profile in nature and be a Complete system for a broad spectrum of cranial indications having following specifications technically – • A modular system having autoclavable module for instruments and implants • All plates are should be 0.5mm thick and implants should be offered in various shapes for an optimal and appropriate choice in the procedure there should include basic plates, frame plates, adaption plates-available in multi holes, burr hole covers, burr hole covers for shunt and mesh plates in various dimensions (both 0.4mm & 0.6mm should be available). • Temporal & mastoid region should have dedicated plates for use. • Screw/plate profile should be not more than 0.6mm for minimum palpability. • Despite the minimum profile, the plate strength should be comparable to thicker cranial plates. • The screws should be designed for hard cranial bones and should have a plus Drive recess for excellent screw retention in the shaft. • The screws should have a flat head and should be easy to pick up with a self holding shaft, means should have adhesive property with screw holder. • The screws must be self-drilling and self-tapping types. • Screw lengths should be available in 3-6mm. • Emergency screws having different colour than regular screws. • The screw driver handles with hexagonal coupling. • Long (66mm) and short (42mm) shafts which should be self holding in nature and compatible with all screws in the system and also fit the handle instantly. • Holding instrument for plates must be a part of the instrumentstion. • A special cutter for strut & mesh plares to be provided in the system. • Appropriate 1.3mm drill bits of 4mm & 6mm depth having stops. • Appropriate Lable clips for the screws which should be replaceable.

1

-

-

... More
Burr hole cover plate

1

-

-

... More
Cranial fixation system for craniotomized bone flaps and bone fragments in neurosurgery (equivalent to Craniofix)

1

-

-

... More
HA coated Multiaxial screws for osteoporotic spine fixation

-

-

-

... More
• (Implants compatible with vertebral column manipulation and vertebral body rotation rotation instrumentation) • Open ended Reverse thread Top loading Top Tightening fixed Angle screws (assorted size) 4.5mm, 5.5mm, 6.5mm with breako off type of plug. • Open ended Reverse thread Top loading Top Tightening Multiaxial screws (assorted size) 4.5mm, 5.5mm, 6.5mm Reduction Screws 4.5mm, 5.5mm, 5.5mm, 7.5mm Break off plugs Reduction Break off plugs Transverse connectors (assorted size) Staples 13mm, 15mm, 17mm Double Rod Staple 21, 23, 25mm rostral and Caudal Domino’s axial connectors Reverse thread Top loading Top Tighteneing pediatric Hooks-upper thoracic, laminar, Pedicular small and medium, right/left offset, Angled hooks.

1

-

-

... More
Percutaneous Pedicular screw Systems for multilevel fixation (For MIS system)

-

-

-

... More
6. The minimal invasive pedical screw system must be offered that is suitable for offset 3 levels of fixation. 7. The raw material used for the implant should be Titanium . 8. MIS screws have to be cannulated, which designed to work in tandem with expandable retractor that facilitates screw implantation in spite of reduced visualisation within narrower working channels. 9. The placement of the rod in MISS is crucial as the surgery is Percutaneous. 10. The Rods should be precontoured.

1

-

-

... More
Bone Substitute

-

-

-

... More
Bone Substitutes should be made up of combination of BTCP (85%) and HA(15%) having capability of re-generating new bone twice as fast as hydroxyapatite. It should also have a dual mechanism of action. It should be in sterile packing and one unit should contain 10cc. It should be available in the form of Block, Cylinder, Wedge, Granules, Strip, Paste.

1

-

-

... More
Digital vertebroplasty -Kit

-

-

-

... More
Consists of: cement delivery system, Biopsy trocar/canula and vertebroplasty cement

1

-

-

... More
Digital kyphoplasty-Kit

-

-

-

... More
Consists of: Balloon placements and cement delivery system, Biopsy trocar/canula kyphoplasty cement, Inflatable balloon – 15mm/20mm, Pressure gauge syringe.

1

-

-

... More
INUSE BONE GRAFT (small, medium, large)

1

-

-

... More
SUBLAMINAR TITANIUM CABLE SYSTEM

-

-

-

... More
The Cable should be made of multiple strands of titanium to enable better grip over tissues. The individual packaging should be available in double cable and Single Cable individual sterilized packaging. It should be malleable. It should with stand twisting and knotting without loosing its tensile strength. It should have a builtin crimp to enable fixation without having to tie a knot and have optimal tension after fixation. It should be of Medical Grade Titanium and should be artifact free on MRI and CT. Titanium double cable with integral crimp Titanium single cable with integral crimp Provisionalcrimps – 2Nos Cable Tensioner – 1Nos Cable Cutter-1Nos Graphic Sterlization case

1

-

-

... More
SHUNT SYSTEM:

-

-

-

... More
1) Omaya Reservoir (Puding type) 2) Ventriculo Peritoneal Shunt (equivalent to VP shunt by Surgiwear/Hindustan Latex Pvt Ltd.) d. Lowpressure e. Medium pressure f. High pressure 5) Programmable Ventriculo peritoneal shunt with variable adjustable pressure with at least 8-10 i. variable pressure settings, non invasive, no mandatory but optional x ray ii. confirmation of pressure settings, MRI compatible 6) Theco-peritoneal shunt 7) External Ventricular drainage system External Lumbar Drainage system

1

-

-

... More
Aneurysm Clips

-

-

-

... More
vii. Sugita type viii. Made of titanium or MRI compatible material ix. Both temporary and permanent type x. Fenesterated/ non fenestrated xi. In various shapes straight/ up curve/downcurve/bayonet type/ right angle bent/ 45 angled/ lateral bent xii. Sizes mini/ 5mm/6mm/7mm/8mm/ 9 mm/10 mm/ 12 mm in each shape and type mentioned above With clip applicators availability for both permanent and temporary clips of variable sizes at the time of surgery

1

-

-

... More
Disposable items for RFTA machine compatible withInomed made model

-

-

-

... More
Patient plate with wire

1

-

-

... More
RF Reusable electrode 10 cm with wire

1

-

-

... More
RF Disposable Cannula 10 cm long , 10mm Tip, 22G

1

-

-

... More
RF Disposable Cannula 10 cm long , 5mm Tip, 22G

1

-

-

... More
RF Disposable Cannula 10 cm long , 10mm Tip, 20G

1

-

-

... More
RF Disposable Cannula 10 cm long , 5mm Tip, 20G

1

-

-

... More
RF Disposable Cannula 5 cm long , 4mm Tip, 22G

1

-

-

... More
RF Disposable Cannula 15 cm long , 10mm Tip, 20G

1

-

-

... More
RF Reusable electrode 15 cm with wire

1

-

-

... More
RF Reusable electrode 5 cm with wire

1

-

-

... More
Disposable items for Electric high speed drill Stryker made

-

-

-

... More
cutter blade

1

-

-

... More
Diamond burr of various size

1

-

-

... More
cutter burr of various sizes

1

-

-

... More
Irrigation cassette with tubing disposable

1

-

-

... More
Burr Perforator

1

-

-

... More
5100060001 PERFORATOR BIT

1

-

-

... More
5820010010 Cutting bur 1mm

1

-

-

... More
5820010220 Cutting bur 2mm

1

-

-

... More
5820010230 Cutting bur 3mm

1

-

-

... More
5820010240 Cutting bur 4mm

1

-

-

... More
5820010250 Cutting bur 5mm

1

-

-

... More
5820010260 Cutting bur 6mm

1

-

-

... More
5820012010 ROUND DIAMOND BUR 1.0MM

1

-

-

... More
5820012020 ROUND DIAMOND BUR 2.0MM

1

-

-

... More
5820012030 ROUND DIAMOND BUR 3.0MM

1

-

-

... More
5820012040 ROUND DIAMOND BUR 4.0MM

1

-

-

... More
5820012050 ROUND DIAMOND BUR 5.0MM

1

-

-

... More
5820012060 ROUND DIAMOND BUR 6.0MM

1

-

-

... More
5407FA2023 FA2 2.3MM TAPERED ROUTER 16MM

1

-

-

... More
5290075000 CORE ESSX/HUMMER IRRIGAT. CAS. ( Pk Of 10)

1

-

-

... More
5290640100 4.0MM 60 DEG. AGG SERR BLADE ( Pk Of 5)

1

-

-

... More
5290740200 4.0MM CONVEX ANGLED AGGRESSIVE ( Pk Of 5)

1

-

-

... More
5290740100 4.0MM ANGLED AGGRESSIVE BLADE ( Pk Of 5)

1

-

-

... More
5290645000 4.0MM AGGRESSIVE SERRATED ( Pk Of 5)

1

-

-

... More
5290011000 4.0MM AGGRESSIVE BLADE 11CM ( Pk Of 5)

1

-

-

... More
5290440100 4.0MM 40 DEG. AGG SERR BLADE

1

-

-

... More
Miscellaneous Items:

-

-

-

... More
Bone cement Depuy or equivalent for cranioplasty

1

-

-

... More
Customised Peek cranioplasty impant for better reconstruction of craniectomy defect

1

-

-

... More
Indocyanine green dye 20ml/50ml

1

-

-

... More
5 amino levulanic acid dye 20ml/50ml

1

-

-

... More
Polyvinyl alcohol Nasal packing with thread

1

-

-

... More
Bipolar cable: (a) Compatible with Alan made cautery (b) compatible with Storz endoscopy cautery

1

-

-

... More
Bipolar forceps non sticky tip bayonet / straight : (a) Compatible with Alan made cautery (b) compatible with Storz endoscopy cautery

1

-

-

... More
Subcutaneous ventriculo peritoneal shunt passer (paediatric)

1

-

-

... More
Subcutaneous ventriculo peritoneal shunt passer (adult)

1

-

-

... More
Disposable Microscope cover for Pentero 900

1

-

-

... More
Autoclaveble OT shoes

1

-

-

... More
NEURO SURGERY INSTRUMENTS SET

-

-

-

... More
CUSHING DURAL HOOK 140mm

1

-

-

... More
GRUENWALD FORCEPS BAYONET SHAPE,7" T.C. TIP -

1

-

-

... More
MAYO HEGARS NEEDLE HOLDERS 200mm

1

-

-

... More
HEGAR NEEDLE HOLDER WITHGROOVE 20CM

1

-

-

... More
INGE LAMINA SPREADER JAWS OPENTO 1-1/4" LENGTH 6" -

1

-

-

... More
FERRIS SMITH I.V.D RONGUERS CD.UP180mm 3mmx 10mm

1

-

-

... More
FERRIS SMITH I.V.D RONGUERS CD.UP180mm 4mm x 10mm

1

-

-

... More
BRAIN CANNULA 8MM

1

-

-

... More
BRAIN CANNULA 10MM

1

-

-

... More
MAYOS SCISSORS CD. 160mm

1

-

-

... More
VENTRICULAR CANNULA 2 X 70MM DIA.

1

-

-

... More
- DO -, 2.5 X 70MM DIA.

1

-

-

... More
GERALD DRESSING FORCEPS BAYONETPLAIN 190mm

1

-

-

... More
HUDSONS BRACE

1

-

-

... More
YASARGIL MICRO SCISSORSTRAIGHT 185mm

1

-

-

... More
JACOBSON MICRO SCISSORCURVED 185mm

1

-

-

... More
POTTS-YASARGIL MICRO SCISSORANGLED 45 DEG, 185mm

1

-

-

... More
MICRO SUTURE TYING FORCEPS ST.TIP0.3mm x 150mm

1

-

-

... More
MICRO SUTURE TYING FORCEPS CD.TIP0.3mm x 150mm

1

-

-

... More
MICRO SUTURE TYING FORCEPS ST.TIP0.5mm x 180mm

1

-

-

... More
MICRO NEEDLE HOLDER WITH CATCHST. 185mm

1

-

-

... More
YASARGIL LIGATURE GUIDE & CARRIER BALL TIPPED CURVED 185MM

1

-

-

... More
YASARGIL MICRO RASPATORY MICRODISSECTOR ANGLED 185mm

1

-

-

... More
DANDY SCALP HAEMOSTATIC FORCEPSCURVED 140mm

1

-

-

... More
CUSHING DISSECTING FORCEPS BAYONETSHAPE PLAIN 180mm

1

-

-

... More
HALSTED MOSQUITO ARTERY FORCEPS CD.125mm

1

-

-

... More
ADSON CEREBELLER RETRACTOR SHARP,ANGLED 180mm

1

-

-

... More
ADSONS DISSECTING FORCEPS PLAIN125mm

1

-

-

... More
ADSONS DISSECTING FORCEPS TOOTHED125mm

1

-

-

... More
ADSONS DISSECTING FORCEPS TOOTHED150mm

1

-

-

... More
CUSHING DISSECTING FORCEPS BAYONETSHAPE TOOTHED 200mm

1

-

-

... More
WULLSTIEN S/R RETRACTOR3 X 3 PRONGS BLUNT 13CM SISCO

1

-

-

... More
RUSKIN BONE RONGUERS D/A CD.4mm x185mm

1

-

-

... More
PENFIELD DISSECTOR DOUBLEENDED 175mm 1,2,3,4 no.

1

-

-

... More
SCHIMIDER TAYLOR SCISSOR16CM

1

-

-

... More
MALLABLE BRAIN SPATULA NARROW WITH SERRATED 200mm

1

-

-

... More
MALLEABLE RETRACTOR of various sizes

1

-

-

... More
Disc Forceps in various sizes

1

-

-

... More
Bone Punches (Ronguers) of various sizes

1

-

-

... More
GILLIES TISSUE FORCEPS 1x2 TEETH150mm

1

-

-

... More
MICRO ADSONS DISSECTING FORCEPSTOOTHED 180mm

1

-

-

... More
YASARGIL MICRO SCISSORSTRAIGHT 225mm

1

-

-

... More
YASARGIL MICRO SCISSOR BAYONETSTRAIGHT 165mm

1

-

-

... More
JACOBSON MICRO PROBE WITH BALLTIP (COUNTER PRESSER) 185mm

1

-

-

... More
CLOWARD CERVICAL VERTEBRA SPREADER

1

-

-

... More
CLOWARD LARGE CERVICAL RETRACTORSET OF 10 BLADES 255mm

1

-

-

... More
MAYO HEGAR NEEDLE HOLDER T/C TIP150MM

1

-

-

... More
TOENNIS-ADSON SCISSORS TC TIPCD. 175MM

1

-

-

... More
METZENBAUM SCISSORS TC TIP ST200mm

1

-

-

... More
COTTLE CHISEL 4mm x 180mm

1

-

-

... More
LANDOLT TUMOUR GRASPING FORCEPSBLUNT SHAFT 200mm

1

-

-

... More
MALLEABLE BRAIN SPATULAS, 8"

1

-

-

... More
CASPAR LONGUS COLLI MUSCLEDISSECTOR 175MM

1

-

-

... More
FARAZIER DURAL HOOK 5"

1

-

-

... More
Suction canula set of four, No. 1,2,3,4

1

-

-

... More
Scalpal handle bayonet shape 210mm 8.50 inch

1

-

-

... More
Cairns neuro scissors

1

-

-

... More
ListonBone cutting Forceps 275 mm curved on flat

1

-

-

... More
Hartman crocodile brain biopsy forceps 175mm

1

-

-

... More
----------------------do-------------------------------250 mm

1

-

-

... More
Adson self retaining retractor blunt 330mm

1

-

-

... More
Miskimon cerebellar retractor

1

-

-

... More
Harvey jackson laminectomy retractor hined arms blade 1.5" wide ;1.75" deep ;Length 290mm

1

-

-

... More
Kilner Needle Holder Box Joint 0.4mm ;5" length TC jaws Gold plated

1

-

-

... More
Auto clavables.steel drum's 15"x12"

1

-

-

... More
Auto clavables.s tray with LID for microsurgical ins. with Silicone matt.

1

-

-

... More
Auto clavables.steel tray with LID 12"x18"

1

-

-

... More
Schlesinger IVD Rongeur, Size :- 152 mm shaft :,cup 2x10mm

1

-

-

... More
Schlesinger IVD Rongeur, Size :- 152 mm shaft:, cup 3x10mm

1

-

-

... More
Schlesinger IVD Rongeur, Size :- 152 mm shaft :,cup 4x10mm

1

-

-

... More
Hardy kerrision punch , Size :- 1mm, 40degree up’’ Length

1

-

-

... More
Cervical kerrision thin plate , Size :- 40º degree up, 2mm, 7’’ length Gold screw

1

-

-

... More
Lumbar kerrision Rongeur , Size :- 40º degree up, 3mm, 8’’ Length

1

-

-

... More
Lumbar Kerrison Rongerur Hardy style Handle with Ball spring 40º up 8’’ Length

1

-

-

... More
StilleLeur Rongeur Curved Bite, 5mm Length 229mm

1

-

-

... More
StilleLeur Rongeur curved Bite, 10 mm, Length 216 mm

1

-

-

... More
Biomimetic Synthetic Absorbable Dural Substitute.. 1.It should have thickness between 0.1 to 0.5 mm 2. It can be sutured and onlay on to the dural defect.

1

-

-

... More
Cervical Self Retaining Retractor set Length-254 mm Opening- 144 mm With Seven Pairs Retractor Blade 25mm to 55 mm@ 5mm Interval

1

-

-

... More
Vertebral body spreader with ratchet lock length – 127mm

1

-

-

... More
Mayo Hegar needle holder , length – 7’’ TC Inserts

1

-

-

... More
Adson dural needle holder fenestrated jaws , length -181mm

1

-

-

... More
Arachnoid Knife 2mm / 3 mm / 4mm

1

-

-

... More
Fogarty’s balloon catheter for endoscopic third ventriculostomy 4 Fr/ 5 Fr

1

-

-

... More
Long artery forceps

1

-

-

... More
Cheatle forceps

1

-

-

... More
Tongue depressor

1

-

-

... More
Catspaw retractor

1

-

-

... More
Markham – meyerding hemilaminectomy retractor of various sizes

1

-

-

... More
Mayo table

1

-

-

... More
Craniotomy burr perforator for use with Hudson brace

1

-

-

... More
Yasargil arachnoid knife

1

-

-

... More
Subcutaneous ventriculo peritoneal shunt passer (adult)

1

-

-

... More
Yasargil biopsy forcep

1

-

-

... More
Toothed dissecting forceps

1

-

-

... More
Wooden handle dissector

1

-

-

... More
Titanium made NEURO SURGERY INSTRUMENTS SET

-

-

-

... More
Micro-scissor of various sizes

1

-

-

... More
Micro needle holder of various sizes

1

-

-

... More
Tissue/ tumor grasping forceps of various tips and sizes

1

-

-

... More
Microscopic probe

1

-

-

... More
Microscopic scoop

1

-

-

... More
Microscopic dissector

1

-

-

... More
Microscopic curette

1

-

-

... More
Microscopicrasparatory

1

-

-

... More
Microscopic Tumor knife

1

-

-

... More
Microscopic hooks

1

-

-

... More
Modular suction cannula

1

-

-

... More
Bipolar forceps

1

-

-

... More
Instruments organization system trays

1

-

-

... More
Microscopic Arachnoid knife

1

-

-

... More
Electrical Drill (MANMAN) Craniotome & Perforator

-

-

-

... More
Craniotome cutter blade

1

-

-

... More
Craniotome hand piece

1

-

-

... More
Craniotome cutter hand piece

1

-

-

... More
Shaft for Craniotome

1

-

-

... More
Reusable Perforator 10/12/14mm burr

1

-

-

... More
Non Oxidizad Regenerated cellulose Haemostat used in Trauma and surgical procedure for Mild, Moderate to Severe bleeding, non- exothermic and have non-compression mechanism, can absorb up to 2000% - 2500% of its initial weight in fluid. Size 10x10cm (4x4 inch)

1

-

-

... More
Non Oxidizad Regenerated cellulose Haemostat used in Trauma and surgical procedure for Mild, Moderate to Severe bleeding, non- exothermic and have non-compression mechanism, can absorb up to 2000% - 2500% of its initial weight in fluid. Size 5x7.5cm (2x3 inch)

1

-

-

... More
Clauses For Electrical Drill with Craniotome & Perforator

-

-

-

... More
1. Craniotome and perforator along with shaft should be auto clavable. 2. The perforator should have safety mechanism with automatic release system as soon as it touches the soft portion of dura. 3. Cranitome cutter shoud have dura guard with thin foot plate 4. Manufacture Company should submit warranty period for at least 02 years for complete system, include 5. ng motor, perforator and Craniotome. 6. Manufacture Company should make the accessories available to the dept on demand basis at a short notice of 48 hrs. 7. Firms should quote the prices of accessories like craniotome blade and perforator separately. 8. Company should be ISO/CE certified

1

-

-

... More
Sterilit – Oil Spray

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.