Jaipur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Telecommunication Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Sep 2024
Closing Date9 Oct 2024
Tender Amount₹ 11,10,000 
Notes
Download

Costs

  • EMD

    ₹ 22,200
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation of pit in ordinary rock which does not require blasting to errect various supports and stay sets including stacking of excavated musk from the edge of excavation/pit

-

-

-

... More
(A) Height of poles/R.S. joist/M.S. rail size of pit

-

-

-

... More
9 Mtr./1.2mx0.6mx1.60m deep

100

25572

255.72

... More
(B) Lattice Tower/size of pit

-

-

-

... More
11.4/10.8Mte/1.5mx1.5x1.80m deep

-

-

-

... More
12.8/12.6Mte/1.5mx2.10m deep

8

12529

1566.22

... More
(c) Stay set/Depth of pit

-

-

-

... More
8'x3/4''-0.75x0.5x1.6m

75

17435

232.47

... More
Safe carriage of PCC Pole including loading/uin-loading

-

-

-

... More
(A) 9 Mtr. long 400 kg./11 Mtr. PCC PCC pole

-

-

-

... More
with in 10 Km.

100

23174

231.74

... More
Above 10 kms upto 30 Kms Add for each Kms or part thereof [4.75X20=95]

100

9500

95

... More
Sate carriage of steel i.e. MS rails, R.S. joists, MS Channels, MS Angles, MS Flats, GI Stay sets, GI Stay wire, GI wire, Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store/at work site

-

-

-

... More
with in 10 Km.

6

1953

325.65

... More
above 10 Kms. Add for each Kms or part thereof [4.61X20=92.20]

6

553

92.2

... More
Safe Carriage of insulator, hardware, cable etc. including loading/unloading and stacking in Nigam stores etc.

-

-

-

... More
with in 10 Km.

2

780

390.29

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[5.57x20=111.4]

2

222

111.4

... More
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolator structures etc. including loading / unloading and stacking in the Nigam Stores / at work site.

-

-

-

... More
With in 10 Kms.

4

1898

474.71

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.61x20=92.2]

4

368

92.2

... More
Errection of PCC poles in excavated pit with fixing of brackets, cross arms & top hampers as required in allignment after checking the same with plumb line. The support is to be back filled with rock with proper ramming. The nut & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailing discom store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (400Kg.)

88

39591

449.9

... More
Errection & assembly of 2 pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M.S. Channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailling Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long (200Kg.)/11Mtr.Long

6

6630

1105

... More
Errection and fixing of GI Stay sets with anchor plates in excavated pit in required position. & back filled with soil with proper ramming. The work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension size of say set/stay wire.

-

-

-

... More
8"x3/4" with 7/8 SWG Stay wire

75

20910

278.81

... More
Erection & fixing of steel struts in the excavated pit in position. The top and of the strut will be properly holed/welded with the main support muffed in cement concrete of ration 1:3:6 as per item No. 5.7. The nuts and bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rate. The cost of muffing and qroutinq will be

-

-

-

... More
Lattice Structure

4.4

15004

3410.02

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering/famer base.

8

22591

2823.89

... More
Supply and laying of rubble stone boulder having weight not less then 20 Kgs.

60

27766

462.77

... More
Fixing of all type of febricated material on errected supports with nut & bolts as per approved design & drawing of sub station.

0.85

2686

3160.02

... More
Fixing of L.T. brackets with clamp on erected support as per design. The nuts and bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
4' long.

-

-

-

... More
Guarding Bracket arms with clamp on erected support as per desing The nuts & bolts will be supplied by the contrctor as per Nigam' specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33 KV line

-

-

-

... More
Fixing and assembly of disc point channel pair with pilot plates & clamps on on erected double structure as per design. The nuts & bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33 KV line

-

-

-

... More
Fixing and assembly of disc point channel pair with pilot plates top hampers & clamps on errected single pole structure as per design. The nut & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailing discom store issue rates.

-

-

-

... More
33 KV line

-

-

-

... More
Fixing of 11 kv B&S/T&C type disc insulator of 33 kv lines (each unit consiting of 3 nos disc & 1 set of H/W) on terminal point including fixing of hardware and strips

126

5916

46.96

... More
Assembly installation & commissioning of gang operated isolating switch on errected structure with setting for accurate Operation ineluding fixing of allied accessories completing all respect with post insulator and jumpering on both ends for connection with the system The nut & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(b) G.O. Switch without earthing blade

-

-

-

... More
33 KV GO switch

1

1235

1235.98

... More
Fixing of 33KV Pininisulator with Pin

282

4193

14.87

... More
Fixing of a set of 4 Nos 33 KV Cross arms (Chakri) Made of MS channel with bracing of MS Flat The Nut and bolts bolts shall be supplied by the prevailing Discom store issue rates.

-

-

-

... More
Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed. Using bolted type H/W including binding on pin insulators, jumpering of section points with binding wire / PG Clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G. clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(b) IN RURAL AREA

-

-

-

... More
ACSR DOG

14.1

36438

2584.3

... More
Laying, jointing, stringing, tensioning and clamping of G.I.Earth wire continuously on single/double pole by using earth clamps/nuts & bolts with washers and earth reel etc. including proper binding at each end. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom, store issue rates.

-

-

-

... More
IN RURAL AREA

-

-

-

... More
G.I.Earth wire 6 SWG

4.7

4202

894.23

... More
Drawing & stringing of G.I. 4 wire over the guarding bracket for guarding of road crossing/P&T crossing, Railway track crossing (for one span only) with cross G.I.wire laces at an interval of one meter each or required as per location using EYE bolt, nuts and bolts with washers etc. including binding. The EYE bolts and other nuts and bolts will be provided by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
6 SWG with laces of 10 SWG

1

845

845.11

... More
Earthing of line for all type of support as per REC construction standards using stay wire / GI wire with one pcs MS rod 20 mm dia each 3 meter long and driving into earth by mechinical means as per approved design. Drawing & specification. alll material expect MS Rod, MS Flat & Stay wire will be supplied by the contracotr, the payment will be made as per priviling Discom issue rate. ( In case of PCC poles earthing must be connected with earth wire already available on PCC pole at bottom).

15

5028

335.22

... More
Laying of MS Flat /MS Rod in 0.65 Mtr. deep excavation tranch and welding of MS Flat/Rod continuosly with 100 mm overlaping for strarght joint including coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rush

-

-

-

... More
Drilling of holes in MS Channel / Angel/Flat

-

-

-

... More
15/16" dia hole (23.81 mm dia)

-

-

-

... More
13/16" dia hole (20.63 mm dia)

-

-

-

... More
Part-2

-

-

-

... More
Grass cutting and surface dressing including removal of anwanted/rubbish plants with roots from open ground/yerd and other nigam premises with stacking of grass/plants at desired place near the ground.

1200

35976

29.98

... More
Levelling of ground up to 30 cm.depth with tracior and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder. (Including all lead & lifting)

1200

1812

1.51

... More
Excavation of pit in Hard soil

-

-

-

... More
(A) Height of poles/R.S. joist/M.S. rail size of pit

-

-

-

... More
9 Mtr./1.2mx0.6mx1.50m deep

-

-

-

... More
Excavation of pit in ordinary rock which does not require blasting to errect various supports and stay sets including stacking of excavated musk from the edge of excavation/pit

-

-

-

... More
(A) Height of poles / R.S. Joist/M.S. rail size of pit

-

-

-

... More
9 Mtr./1.2mx0.6mx1.50m deep

38

9717

255.72

... More
Fixing of 11 KV, 0.6 Mtr. Long top hamper made of ISA M.S. Angle 65X+6X6 mm on the existing pole complete including nut & bolts etc. (Steel Wt. 4.4 Kg. Approx.)

-

-

-

... More
Hard/Dense soil

-

-

-

... More
Fixing of M.S. Channet Channel 100x50 ISMC (For cut Point) 2x1.3 meter long with pilot patti 50x6 mm thick on single support/pole/lattice structure & necessary clamps, Nut & Bolts etc. (29.5 Kg Approx.)

-

-

-

... More
Safe carriage of PCC Pole including loading/uin-loading

-

-

-

... More
a) 9 Mtr. long 400kg/11mtr. PCC pole

-

-

-

... More
Within 10 Kms.

8

1853

231.74

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.[5.26x20=105.20]

8

760

95

... More
c) 9 mtr. long 200 Kg./11 Mtr. PCC Pole

-

-

-

... More
with in 10 Km.

30

5833

194.46

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.75x20=95]

30

2850

95

... More
Sate carriage of steel i.e. MS rails, R.S. joists, MS Channels, MS Angles, MS Flats, GI Stay sets, GI Stay wire, GI wire, Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store/at work site

-

-

-

... More
with in 10 Km.

6

1953

325.65

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.61x20=92.20]

6

553

92.2

... More
Insulator, hardware, cable, breakers, kiosks, pannels etc., including loading/unloading and stacking in Nigam store etc.

-

-

-

... More
Within 10 Kms.

2

780

390.29

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[5.57x20=111.40]

2

222

111.4

... More
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.

-

-

-

... More
Within 10 Kms.

-

-

-

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.61x20=92.20]

-

-

-

... More
Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading from store to site

-

-

-

... More
b) 25 & 40 KVA

-

-

-

... More
Within 10 Kms.

1

238

238.51

... More
Above 10 Kms. & up to 30 km Add for each Kms. or part thereof[6.78x20=135.6]

1

135

135.6

... More
Safe carrage of 33/11 KV Power transformer

-

-

-

... More
Above 1.6 MVA & upto 3.15 MVA

-

-

-

... More
Within 10 Kms.

1

4268

4268.68

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[42.70x20=854]

1

854

854

... More
Safe Loading of power/destribution transformer

-

-

-

... More
a) 33/11 KV Power transformer

-

-

-

... More
5 MVA

1

5035

5035.67

... More
Safe unloading of power/destribution transformers

-

-

-

... More
a) 33/11 KV Power transformer

-

-

-

... More
Above 3.15 MVA

1

4265

4265.88

... More
Errection and fixing of GI Stay sets with anchor plates in excavated pit in required position. & back filled with soil with proper ramming. The work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension size of say set/stay wire.

-

-

-

... More
8''x3/4" with 7/8 SWG Stay wire

-

-

-

... More
Supply and laying of rubble stone boulder having weight not less then 20 Kgs.

10

4627

462.77

... More
Fixing of all type of febricated material on errected supports with nut & bolts as per approved design & drawing of sub station.

4

12640

3160.02

... More
Fixing of 11 kv B&S/T&C type insu' tor for 33 kv lines (each unit consiting of 3 nos dise & I set of H/W) on terminal point including fixing of hardware design & drawing of sub-station.

18

845

46.96

... More
Fixing of 33 kv pin insulator with pin

6

89

14.87

... More
Fixing of 11 kv pin insulator with pin

30

297

9.92

... More
Assembly installation and commissioning of gang operated isolating switch on erected structure with setting for accurate opperation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailling Discom store issue rates.

-

-

-

... More
B) G.O. switch without earthout earthing blade.

-

-

-

... More
33 Kv G.O. Switch

2

2224

1112.29

... More
11 Kv G.O. Switch

7

6055

865.1

... More
Assembly and installation of Horn Gap set (set of 3nos) on erected structure as per desing complete in all respect with post insulator including Jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33kv Horn Gap fuse set.

1

512

512.84

... More
11 kv Horn Gap fuse set.

5

2224

444.96

... More
Installation of lightening arected stucture/support (set of 3 nos) including connection with earth by wire /strip as required and jumpering etc. the nut & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(A) sub-station type

-

-

-

... More
33 KV L.A. set

3

512

170.95

... More
11 KV L.A. set

-

-

-

... More
installation testing as per Nigam's norm & commissioning of 6.35/.24 KV distribution transformer on erected supports including fixing of base channels as per requirement jumpering on HV & LV side, crimping of logs / clamping earth connections of body and neutral of transformer with wire / strip (as already) provided with earthing) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
25 and 40 KVA

-

-

-

... More
Fixing of PG clamp of dog/Raccon conductor

75

372

4.97

... More
Drawing of overhead ABC conductor (Aerial Bunched Cable) on existing erected pole support including laying ,jointing, stringing complete in all respect.

-

-

-

... More
(a) 1Cx25+25sq mm

-

-

-

... More
Mesh earthing for 33/11 kv sub-station as per approved map & design using MS flat 50x6mm/MS road 20 mm dia includinglaying of flat/rod atthe depth of 0.65 Mtrs., welding & jointing at jaints structures & equipments etc. asunder.

-

-

-

... More
Excavation of trench of) 65 Mtrs. depth and 0.5 Mtr. width

-

-

-

... More
Hard soil

100

15266

152.66

... More
Laying of MS flat/MS rod in 0.65 Mtr. deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

-

-

-

... More
Shaping of MS flat for connecting the equipments with earthmesh. The work includes the welding of MS flat with equipments/structure and also with earth mesh. The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

-

-

-

... More
Preparation of spikes made of M.S. Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and providing & fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil :

-

-

-

... More
Where drilling is required

-

-

-

... More
Erection of pcc poies in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station The pit should be back filled with the soil with proper ramming below 30 cm ground level and the muffed above 15cm average ground level with cement concrete ratio1:3:6 The charges for muffing will be paid extra as per chapter code no 5.7 the nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates.

-

-

-

... More
b) In Rural area

-

-

-

... More
PCC Pole 9 mtrs long

30

12269

408.99

... More
Laying / stringing of bus bar with ACSR Dog & Jumper connection using tie rod 33KV insulator strings, required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer incharge.

-

-

-

... More
ACSR Dog

0.5

11

23.47

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization, filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
33 KV VCB (Outdoor)

1

5013

5013.96

... More
11 KV VCB (Outdoor)

5

25069

5013.96

... More
Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (the CT/PT set will be tested by Discom).

-

-

-

... More
33 KV CT (1 set of 3 Nos.) OR PT Set.

-

-

-

... More
11 KV CT (1 set of 3 Nos.) OR PT Set.

4

4947

1236.88

... More
Installation of metering points on 11 KV Out going feeder at 33/11 KV S/S.

-

-

-

... More
The installation work to be carried out as per drawing/design, under the supervision of concerned Assistant Engineer

-

-

-

... More
Mounting structure

4

79101

19775.39

... More
The requisite steel menber will be supplied by contractor including the hardware Contractor shall joint/weld the menber to form the mounting structure as per drawing necessary tools welding machine lifting device etc shall be arranged by contractor

-

-

-

... More
Civil work

-

-

-

... More
Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as requred (21 days) Area of concreting will be as per the drawing.

-

-

-

... More
Metering Equipment

-

-

-

... More
The requisite metering equipments (CTPT set, meter, meter box & suitable conductors for jumpers), will be provided by the concerned Assistant Engineer in healthy condition at site. The cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alogwith the consumable items such as PVC tapes. petroleum jelly etc. The cable should be PVC multi strandcopper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT set so installed shall be earthed by means of the MS Flat (size 50X6mm) by joining it with the nearest available at the substion. Requisite earthing material shall be made available by the contractor.

-

-

-

... More
Meter

-

-

-

... More
Meters should be fixed firmly inside the tamper proof box, as per drawing all the meter fixture will be provided by contractor including all consumables.

-

-

-

... More
Meter Box

-

-

-

... More
The meter box shall be provided by the concerned Assistant Engineer, however hardware or any other items required to fix the meter inside the meter box will be provided by the contractor, The meter box will be fixed firmly with sufficient strength at a place as per drawing The test terminal block (TTB) link type shall be provided by contractor in the meter box

-

-

-

... More
Painting

-

-

-

... More
All surface interior of lattice structure shall be white aluminium painted

-

-

-

... More
Commissioning of metering Equipment

-

-

-

... More
Installed meters inside the box and metering equipments duly mounted on the mounting structure will be powered up by connecting load in the presence of the concerned Assistant Engineer who will arrange the nesessary shut down. The completion certificate shall be furnised by contactor be filled accordingly since the work involves higher A.C. voltage level, the contractor shall take full care regarding safety norms, so as avoid any accidental

-

-

-

... More
Earth work excavation and foundation of platform of transfarmers and brakers including dressing of sides and ramming of bottoms. Lift to 1.5 meter including taking out the excavated soil and depositing and refiling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.

-

-

-

... More
Hard soil moxed with boulders transfarmer platform size [3*3.3*0.65]*2=12.9

12.9

1391

107.88

... More
kiosice size [2.5*1.3*0.65]*7=14.79

-

-

-

... More
providing and laying cement concrete including complecting etc, usining stone aggrefate 40mm nominal size [hand broken] in foundtion plinth excluding the cost shuttering using 1 cement : 5 sand : 10 aggregate mix. [3*1.70]*2=10.2030.60

70

165983

2371.19

... More
kiosice size [2.5*1.3*0.15]*7=3.41

-

-

-

... More
plaster on new surface on walls in cement , sand mortar 1:6 including racking of joint etc. complete fine finish 25mm thick .2.5*4*2=20

20

2566

128.32

... More
koisice size [2*3*7]=42

-

-

-

... More
cement concrate flooring grade 1:2:4 [1-cement : 2-coarse sand :4- graded stone aggregated ] rounding off edges etc but excluding cost of steps etc. complete.

-

-

-

... More
75mm thick with 20mm normal size aggregate.

19.8

7898

398.92

... More
koisice size [7*1.3]

-

-

-

... More
masonary for foundation and plinth

-

-

-

... More
Randon rubble stone masonary for foundation and plinth in cement sand morth 1:6 [1 cement : 6 sand] including labour charges. Power T/F [3*3.3*1.7]*2=33.66

33.66

64789

1924.83

... More
Randon rubble stone masonary for foundation and plinth in cement sand morth 1:6 [1 cement : 6 sand] including labour charges.Breaker [2.5*1.3*0.65]*7=14.79

14.79

41671

2817.52

... More
Part-3

-

-

-

... More
Conducting route e survey as per approved route map and pegging of route with tee off point selection point & double pole location.

5.6

1118

199.79

... More
Trimming of tree baranches and preparing route appraoches for the proposed line

60

1798

29.98

... More
Excavation of pit in ordinary rock which does not require blasting to errect various supports and stay sets including stacking of excavated musk from the edge of excavation/pit

-

-

-

... More
(A) Height of poles / R.S. Joist/M.S. rail size of pit

-

-

-

... More
9 Mtr./1.2mx0.6mx1.50m deep

115

29407

255.72

... More
b) Lattice Tower/size of pit

-

-

-

... More
12.8/12.6 mtr/1.5m*1.5m*2.10 m deep

5

7831

1566.22

... More
(B) Lattice Tower

-

-

-

... More
(c) Stay set/Depth of pit

-

-

-

... More
8'x3/4"-0.75x0.5x1.6m 7/10 swg

80

18597

232.47

... More
Safe carriage of PCC Pole including loading/uin-loading

-

-

-

... More
a) 9 Mtr. long 200kg/11mtr. PCC pole

-

-

-

... More
with in 10 Km.

115

22362

194.46

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.75x20=95]

115

10925

95

... More
Sate carriage of steel i.e. MS rails, R.S. joists, MS Channels, MS Angles, MS Flats, GI Stay sets, GI Stay wire, GI wire, Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store/at work site

-

-

-

... More
with in 10 Km.

6

1953

325.65

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.61x20=92.20]

6

553

92.2

... More
Insulator, hardware, cable, breakers, kiosks, pannels etc., including loading/unloading and stacking in Nigam store etc.

-

-

-

... More
Within 10 Kms.

2

780

390.29

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[5.57x20=111.40]

2

222

111.4

... More
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.

-

-

-

... More
Within 10 Kms.

2.5

1186

474.71

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.[4.61x20=92.20]

2.5

230

92.2

... More
Errection of PCC poles in excavated pit with fixing of brackets, cross arms & top hampers as required in allignment after checking the same with plumb line. The support is to be back filled with rock with proper ramming. The nut & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailing discom store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (200Kg.)

105

39787

378.93

... More
Errection & assembly of 2 pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M.S. Channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailling Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long (200Kg.)

5

5525

1105

... More
Errection and fixing of GI Stay sets with anchor plates in excavated pit in required position. & back filled with soil with proper ramming. The work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension size of say set/stay wire.

-

-

-

... More
6'x5/8" with 7/10 SWG Stay wire

80

19304

241.31

... More
Erection & fixing of steel struts in the excavated pit in position. The top and of the strut will be properly holed/welded with the main support muffed in cement concrete of ration 1:3:6 as per item No. 5.7. The nuts and bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rate. The cost of muffing and qroutinq will be

-

-

-

... More
Lattice Structure

2.5

8525

3410.02

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering/famer base.

5

14119

2823.89

... More
Supply and laying of rubble stone boulder having weight not less then 20 Kgs.

60

27766

462.77

... More
Fixing of L.T. brackets with clamp on erected support as per design. The nuts and bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
4' long.

-

-

-

... More
2' long.

-

-

-

... More
Guarding Bracket arms with clamp on erected support as per desing The nuts & bolts will be supplied by the contrctor as per Nigam' specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV line

-

-

-

... More
Fixing and assembly of disc point channel pair with pilot plates & clamps on on erected double structure as per design. The nuts & bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV line

5

457

91.43

... More
Fixing of 11 kv B&S/T&C type dise insulator of 11 kv line (each unit consiting of i nos.disc.& Iset of H/W) on terminal point including fixing of hardware and strips.

96

2141

22.31

... More
Fixing of 11 KV Pin Insulator with Pin

330

3273

9.92

... More
Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed. Using bolted type H/W including binding on pin insulators, jumpering of section points with bindingwire / PG Clamps Alluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage of charging . The contractor will be provide P.G. clamps for which payment will be made as per prevailling discom issue rate.

-

-

-

... More
IN RURAL AREA

-

-

-

... More
ACSR Rabbit

16.98

37457

2205.98

... More
ACSR WEASEL

-

-

-

... More
Laying, jointing, stringing, tensioning and clamping of G.I.Earth wire continuously on single/double pole by using earth clamps/nuts & bolts with washers and earth reel etc. including proper binding at each end. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom, store issue rates.

-

-

-

... More
IN RURAL AREA

-

-

-

... More
G.I.Earth wire 8 SWG

5.7

4197

736.47

... More
Drawing & stringing of G.I. 4 wire over the guarding bracket for guarding of road crossing/P&T crossing, Railway track crossing (for one span only) with cross G.I.wire laces at an interval of one meter each or required as per location using EYE bolt, nuts and bolts with washers etc. including binding. The EYE bolts and other nuts and bolts will be provided by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
8 SWG with laces of 10 SWG

-

-

-

... More
Earthing of line for all type of support as per REC construction standards using stay wire / GI wire with one pcs MS rod 20 mm dia each 3 meter long and driving into earth by mechinical means as per approved design. Drawing & specification. alll material expect MS Rod, MS Flat & Stay wire will be supplied by the contracotr, the payment will be made as per priviling Discom issue rate. ( In case of PCC poles earthing must be connected with earth wire already available on PCC pole at bottom).

48

16090

335.22



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.