Jaipur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Sep 2024
Closing Date9 Oct 2024
Tender Amount₹ 10,30,000 
Notes
Download

Costs

  • EMD

    ₹ 20,600
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 500

Summary

Construction Of 33/11 Kv S/s Jyotinagar Jhalawar With Erection Of 33 Kv Line At 33/11 Kv S/s 11 Kv Line I/c At Location 220 Kv Jyoti Nagar Under Aen (htm-i), Jpd, Jhalawar On Labour Rate Of Arc-2023

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(A) Height of poles/ R.S . Joist/M.S.Rail size of pit

-

-

-

... More
9 Mtr/1.2m x0.6m x 1.5 m deep

10

2557

255.72

... More
(B) Lattice tower

-

-

-

... More
11.4/10.8mtr/1.5mx1.5mx1.80m deep

-

-

-

... More
Stay set /Depth of pit

-

-

-

... More
8' x 3/4"-0.75 x 0.5 x 1.6 m

-

-

-

... More
Excavated of pit in Hard rock (Where blasting/drilling is required) to erect various supports and stay set including stacking of excavated muck from the edge of excavation/pit

-

-

-

... More
(A) Height of poles/ R.S . Joist/M.S.Rail size of pit

-

-

-

... More
9 Mtr/1.2m x0.6m x 1.5 m deep

26

24926

958.7

... More
(B) Lattice tower

-

-

-

... More
11.4/10.8mtr/1.5mx1.5mx1.80m deep

-

-

-

... More
Stay set /Depth of pit

-

-

-

... More
8' x 3/4"-0.75 x 0.5 x 1.6 m

-

-

-

... More
Earth work excavotion and foundation of platform of transformers and brackers including dressing of sides and ramming of bottom Liftup to 1.5 meter including tacking out the excavated soil and depositing and refilling of jhin watering and ramming and disposal of wurplus excavated soil as directed with in a lead of 50m (2Nos of transformer platform+5 No's brekers platform )

-

-

-

... More
Hard soil mixed with boulders

45

4854

107.88

... More
Plaster on new surface on wall in cement sand mortor 1:6 including racking of joint etc. complete fine finish 25 mm think

81

10393

128.32

... More
Cement concret flooring graded 1:2:4(1-Cement :2- Coarse :4- Graded stone aggregate ) rounding of edges etc. but excluding cost of nosing of steps etc. complete.

-

-

-

... More
75 mm thick with 20mm thick nominal size aggregate.

144

57444

398.92

... More
Masonry for foundation and plinth

-

-

-

... More
Randdom rubble stone masonry for foundation & plinth in cement sand mortar 1:6 ( 1-cement :6 sand ) including labour charges.

96

184783

1924.83

... More
Safe carriage of PCC poles including loading /unloading

-

-

-

... More
A ) 9 Mtr. Long PCC pole ( 400 Kg)

-

-

-

... More
Within 10 Kms

12

2780

231.74

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Above 30 Kms. Add for each Km. or part thereof

-

-

-

... More
C ) 9 Mtr. Long PCC pole ( 200 Kg)

-

-

-

... More
Within 10 Kms

24

4667

194.46

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of steel (fabricated and unfobricated ) i.e.M.S.Rails, R.S. joist , M.S. channels M.S. Angle ,M.S. flat G.I. stay, G.I.wire Nuts & bolts etc and ACSR conductor including loading /unloading and stacking in Nigam store/ at work site.

-

-

-

... More
Within 10 Kms

5.5

1791

325.65

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of insulator, hardware, cable etc. including loading /unloading and stacking in Nigam stores etc.

-

-

-

... More
Within 10 Kms

2

780

390.29

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of fabricated lattice tower structures and sub-station structure type AB, Ab beams, Isolators structures etc. including loading /unloading and stacking at work site.

-

-

-

... More
With in 10 Kms

-

-

-

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.

-

-

-

... More
Safe carriage of 11/0.4 KV distribution transformer including loading/ unloading from store to site

-

-

-

... More
b) 25 KVA & 40 KVA

-

-

-

... More
Within 10 Kms

1

238

238.51

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of 33/11 KV Power Transformer

-

-

-

... More
b) Above 1.6 MVA & Upto 3.15 MVA

-

-

-

... More
Within 10 Kms

1

4268

4268.68

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
C) 5.0 MVA

-

-

-

... More
Within 10 Kms

1

5081

5081.77

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of breakers/kiosks etc. including loading /unloading and stacking in Nigam stores etc.

-

-

-

... More
Within 10 Kms

8

7117

889.63

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe loading of Power/ distribution transformer

-

-

-

... More
(A) 33/11 KV Power Transformer

-

-

-

... More
Above 1.6 MVA & upto 3.15 MVA

1

3839

3839.29

1

5035

5035.67

... More
Safe unloading of Power/ distribution transformer

-

-

-

... More
(A) 33/11 KV Power Transformer

-

-

-

... More
Above 1.6 MVA & upto 3.15 MVA

1

3225

3225.06

... More
Above 3.15 MVA

1

4265

4265.88

... More
Erection of all type steel supports in the excavated pit in aligment after checking the same with plumb line including fixing of cross arms and top hemper beefore erecting the supports should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remainning portation of the pit will be back filling with soil. The nuts & bolts will be provided by the contractors as per Nigams specification for which payment will be made at the prevalling store issue rates.

-

-

-

... More
Lattice Structure

-

-

-

... More
Erection of Pcc poles in excavated pit with fixing of cross arms and top hemper as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailling Discom stores issue rates.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (400Kg)

-

-

-

... More
PCC Poles 9 Mtr. Long (200Kg)

-

-

-

... More
Erection of assembly of 2 pole structures of steel supports PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M(1piece) with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailling Discom stores issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long/ R.S joist (400 Kg)

-

-

-

... More
PCC Poles 9 Mtr. Long/ R.S joist (200 Kg)

6

6630

1105

... More
Providing and laying of cement concret in ratio 1:3:6 using 43 graded cement river sand and 12 mm to 20 graded blasted crusher brokenin pit/foundation according to the size / type of supports / stay set including compaction /curring for 21 days in steel plate shuttring /farmer base.

18

50830

2823.89

... More
Supplying & Laying of random rubble stone boulder having weight not less than 20 Kgs.

15.5

7172

462.77

... More
Fixing of all type of fabricated material on erected supports with nuts & bolts as per approved design & drawing of sub-station.

4.5

14220

3160.02

... More
Fixing and assembly of disc point channel pair with pilot plates top hampers & clampson erected single pole structure as per design. The nuts & bolts will be supplied by the contractor as per Nigam's specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33 KV line

2

163

81.52

... More
11 KV line

10

593

59.37

... More
Fixing of 11 KV B&S/T&C disc insulator for 33 KV line (each unit consisting of 3 nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.

30

1408

46.96

... More
Fixing of 11 KV B&S/T&C disc insulator for 11 KV line (each unit consisting of 1 nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.

30

669

22.31

... More
Fixing of 11 KV B&S/ T&C disc insulator for 11 KV line (each unit consisting of 2 nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.

30

1008

33.63

... More
Fixing of 33 KV pin insulator with pin.

9

133

14.87

... More
Fixing of 11 KV pin insulator with pin.

45

446

9.92

... More
Assembly, Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate Operation including fixing of allied accessories complete in all respect with post insulator and jumpering on both ends for connection with the system. the nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom stores issue rates.

-

-

-

... More
(B) G.O. Switch without earthing blade

-

-

-

... More
33 KV G.O Switch

5

5561

1112.29

... More
11 KV G.O Switch

14

12111

865.1

... More
Installation of lighting arrester on erected structure / supports ( set of 3 nos. including connection with earth by wire/strips as required and jumpering etc. the nuts & bolts will be provided by the contractor which payments will be made as per discom's store issue rates.

-

-

-

... More
33 KV L.A. Set

6

1025

170.95

... More
11 KV L.A. Set

15

2224

148.32

... More
Installation testing as per Nigam's norms & commissioning of 11/0.4 KV distribution transfarner on erected supports including fixing of bases channels as per requirement jumpring of HV&LV side, crimping of lugs/clamping earth connection of body and new-trial of transfarmer with wire /strips (as already provided with earthing ) complete in all respect. the PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom stores issue rates.

-

-

-

... More
25 KVA & 40 KVA

1

621

621.01

... More
Erection of LT Distribution piller Boxes of 800/400/160/100 Amps. Capacity Each 37"x24" base as per JVVNL standard including excavation ,bricks,sand,cement masonary of size 4"x3"x10" and 3' in ground and 1 1/2' above road level with muffing to support and mounting the piller Themasonary will hase 4" x 4" opening 2" below ground level two in the rear sideand one each in the remaining sides to facilitate entry and exist of incomingand outgoing PVC cable Earthing of the piller shall be connected to DP earth with 7/10 SWG Stay Wire & lugs

-

-

-

... More
400 AMP

1

2212

2212.35

... More
Fixing of PG clamps of Dog/ Racoon Conductor

300

1491

4.97

... More
Drawing of overhead ABC conductor (Aerial Bunched Cable) on existing erected pole support including laying ,jointing, stringing complete in all respect.

-

-

-

... More
(c) 3Cx25+25sq.mm

0.01

36

3618

... More
Mesh earthing for 33/11 KV sub station as per apporved map & design using MS flat 50x6mm /MS rod 20mm dai including laying of flat/rod at the depth of 0.6 mtrs welding & jointing at joint , structures & equpments etc as under.

-

-

-

... More
Excavatoin of trench of 0.65 mtrs depth and 0.5 mtrs width.

-

-

-

... More
Ordinary rock ( where blasting is not req. )

45

13459

299.09

... More
Shapping of MS flat for connecting the equipment with earth mesh The work including the welding of MS flat with equipments/structures and also with earth mesh . the work also including coating of MS flat joints with moltem buitmen and covering joint with biutmen impregnated tape to protact frpm rust.

185

7166

38.74

... More
Filling of trench with available excavated muck in layers of 20 cm (Max) consolid-ating each deposited layers by ramming & watering with lead up to 50 mtr And lift upto 1.5 mtrs.

185

947

5.12

... More
Earthing of New 33/11 KV S/S with bentonit compound involving activities.

6

33940

5656.75

... More
Eraction of PCC poles in excavated pit in alignment after chacking the same with plumb line as per approved design and drawing of 33/11 KV Sub Station . the pit should be back filed with the soil with proper ramming below 30mm ground level and then muffed above 15 cm avarage ground level with cement concrete ratio 1:3:6 the chapter for muffing will be paid by extra as per chapter code -5.7 . the nuts & bolts will be provided by the contractor which payments will be made as per discom's store issue rates.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
PCC Pole 9 Mtr Long

24

12890

537.12

... More
PCC Pole 10/11 Mtr Long

-

-

-

... More
Laying / stranging of bus bar with ACSR / jumper connection using tie rod 33/11 KV insulator string , required hardware PG clamp / T clamp etc as per requirment including Y connection at bus bar jumpering point as per the direction of enginner incharge.

-

-

-

... More
ACSR Dog / RABBIT

450

10561

23.47

... More
Supply,stacking & spreading of stone boulders 40 mm. Mono size.( Less voids 17%)

52

51485

990.1

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works) The relays will be tested by Discom.

-

-

-

... More
33 KV VCB / SF - 6 Breaker

1

5013

5013.96

... More
11 KV VCB ( Outdoor )

7

35097

5013.96

... More
Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning lests before energization & satisfactory operation in all respect ( The CT/PT set will be tested by Discom).

-

-

-

... More
33 KV CT ( 1set of 3 Nos.) OR PT Set

-

-

-

... More
11 KV CT ( 1set of 3 Nos.) OR PT Set

5

6184

1236.88

... More
Installation of metering point on 11 KV outgoing feeder at 33/11 KV S/S

5

98876

19775.39

... More
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush/ sand paper

-

-

-

... More
On new surface

280

9091

32.47

... More
painting with alluminium paint of approved brand and manufacturer as per given an even surface.

-

-

-

... More
On new works with two coast

260

12662

48.7

... More
Fabrication of steel item

-

-

-

... More
Laying of two (D/C) 11 KV ,XLPE, Cable (Al. conductor ) underground cable w/o overlapping as per relevant IS/JVVNL stanards including excavation of 50 cm witdth x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand.'A' class bricks or concrete block covering refilling soil in the remaining portion and providing / fixing cable route indicators at every 30 Mtr.of cable and at every tum.

-

-

-

... More
3x35 Sq mm to 3x185 Sq mm

40

6692

167.32

... More
Note :- Per mtr. Rate shall be paid extra for excavation of puccka road.

40

3575

89.38

... More
Installation of 11 KV cable XLPE Termination straight through joints as per mtr. Kit guidance and direction ind. Preparastion of Cable laying reffiling etc. as required. (Including crimping of lugs)

-

-

-

... More
A (i) Out door end terminal 3X50 Sqmm to 3X185 Sqmm

8

10329

1291.15

... More
C (i) Straight through joint 3X50 Sqmm to 3X185 Sqmm

-

-

-

... More
Laying, testing, termination of control cable, 1100 Volt PVC installed supply and providing of ferrules and copper lugs to designate various cores of control cable by terminal numbers for identification including utilization of cable glands.The control cable should be neatly arranged in trenches avoiding crossings, including clamping of control cable in rubber battons at regular interval and providing identity tages.

-

-

-

... More
d) 12x2.25 Sq.mm.

25

660

26.43

... More
Safe Loading of New/ old 11 KV CT PT set ( all size)

5

578

115.63

... More
Safe Unloading of New/ old 11 KV CT PT set ( all size)

5

258

51.64

... More
Fixing of Alluminium lugs

-

-

-

... More
185 Sq mm

45

939

20.88

... More
MS Nuts & Bolts

-

-

-

... More
Part-2

-

-

-

... More
Excavated of pit in ordinary rock which does not require blasting/murrad ( in Jodhpur discom) to erect various supports and stay set including stacking of excavated muck from the edge of excavation/pit

-

-

-

... More
(A) Height of poles/ R.S . Joist/M.S.Rail size of pit

-

-

-

... More
9 Mtr/1.2m x0.6m x 1.5 m deep

3

767

255.72

... More
Stay set /Depth of pit

-

-

-

... More
8' x 3/4"-0.75 x 0.5 x 1.6 m

2

464

232.47

... More
Excavated of pit in Hard rock (Where blasting/drilling is required) to erect various supports and stay set including stacking of excavated muck from the edge of excavation/pit

-

-

-

... More
(A) Height of poles/ R.S . Joist/M.S.Rail size of pit

-

-

-

... More
9 Mtr/1.2m x0.6m x 1.5 m deep

8

7669

958.7

... More
Stay set /Depth of pit

-

-

-

... More
8' x 3/4"-0.75 x 0.5 x 1.6 m

6

3983

663.94

... More
Safe carriage of PCC poles including loading /unloading

-

-

-

... More
A ) 9 Mtr. Long PCC pole 400 kg

-

-

-

... More
Within 10 Kms

11

2549

231.74

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of steel (fabricated and unfobricated ) i.e.M.S.Rails, R.S. joist , M.S. channels M.S. Angle ,M.S. flat G.I. stay, G.I.wire Nuts & bolts etc and ACSR conductor including loading /unloading and stacking in Nigam store/ at work site.

-

-

-

... More
Within 10 Kms

0.8

260

325.65

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Safe carriage of insulator, hardware, cable etc. including loading /unloading and stacking in Nigam stores etc.

-

-

-

... More
Within 10 Kms

0.4

156

390.29

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Erection of Pcc poles in excavated pit with fixing of cross arms and top hemper as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailling Discom stores issue rates.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (400Kg)

5

2953

590.78

... More
Erection of assembly of 2 pole structures of steel supports PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M(1piece) with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailling Discom stores issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long/ R.S joist (400 Kg)

3

3893

1297.81

... More
Erection & fixing of G.I Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps Stay Insulator with stay wire at both ends with proper tension. Size of stay set/ stay wire.

-

-

-

... More
8' x 3/4" with 7/8 SWG stay wire

8

2230

278.81

... More
Providing and laying of cement concret in ratio 1:3:6 using 43 graded cement river sand and 12 mm to 20 graded blasted crusher brokenin pit/foundation according to the size / type of supports / stay set including compaction /curring for 21 days in steel plate shuttring /farmer base.

-

-

-

... More
Supplying & Laying of random rubble stone boulder having weight not less than 20 Kgs.

9.5

4396

462.77

... More
Fixing and assembly of disc point channel pair with pilot plates top hampers & clampson erected single pole structure as per design. The nuts & bolts will be supplied by the contractor as per Nigam's specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33 KV line

2

163

81.52

... More
Fixing of 11 KV B&S/T&C disc insulator for 33 KV line (each unit consisting of 3 nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.

18

845

46.96

... More
Fixing of 33 KV pin insulator with pin.

30

446

14.87

... More
Laying, jointing , stringing, tenstioning and clamping of conductor with proper sage as directed, using bolted type hardware including binding on pin insulators, jumpring on section point with binding wire / P.G. clamps aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging. The contractor will be provide P.G. clamps for which payment will be made as per prevailling Discom issue rate.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
ACSR DOG Conductor

0.81

2361

2915.03

... More
MS Nuts & Bolts

-

-

-

... More
Part-3

-

-

-

... More
Safe carriage of insulator, hardware, cable etc. including loading /unloading and stacking in Nigam stores etc.

-

-

-

... More
Within 10 Kms

1.7

663

390.29

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof

-

-

-

... More
Laying of 11 KV ,XLPE, Cable (Al. conductor ) underground as per relevant IS/JVVNL stanards including excavation of 30 cm witdth x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand.'A' class bricks or concrete block covering refilling soil in the remaining ( Including fixing of G.I. Pipe of required size at both end with 3 Mtr projected above the ground surface & 0.3 Mtr. below ground level)

-

-

-

... More
3x35 Sq mm to 3x185 Sq mm

-

-

-

... More
Note :- Per mtr. Rate shall be paid extra for excavation of puccka road.

-

-

-

... More
Laying of two (D/C) 11 KV ,XLPE, Cable (Al. conductor ) underground cable w/o overlapping as per relevant IS/JVVNL stanards including excavation of 50 cm witdth x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand.'A' class bricks or concrete block covering refilling soil in the remaining portion and providing / fixing cable route indicators at every 30 Mtr.of cable and at every tum.

-

-

-

... More
3x35 Sq mm to 3x185 Sq mm

160

26771

167.32

... More
Note :- Per mtr. Rate shall be paid extra for excavation of puccka road.

140

12513

89.38

... More
Installation of 11 KV cable XLPE Termination straight through joints as per mtr. Kit guidance and direction ind. Preparastion of Cable laying reffiling etc. as required. (Including crimping of lugs)

-

-

-

... More
A (i) Out door end terminal 3X50 Sqmm to 3X185 Sqmm

20

25823

1291.15

... More
C (i) Straight through joint 3X50 Sqmm to 3X185 Sqmm

-

-

-

... More
Fixing of Alluminium lugs

-

-

-

... More
185 Sq mm

60

1252

20.88

... More
MS Nuts & Bolts

-

-

-

... More
Part-4

-

-

-

... More
Erection of assembly of 2 pole structures of steel supports PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M(1piece) with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per nigam specification for which the payment will be made at the prevailling Discom stores issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long/ R.S joist (200 Kg)

-

-

-

... More
Removal of PCC Poles 9 Mtr. Long/ R.S joist (200 Kg)

5

3315

663

... More
Fixing of Cross arms with clamps on erected support as per design. The nuts & bolts will be supplied by the contractor as per Nigam's specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV Cross arms

-

-

-

... More
11 KV Cross arms

5

96

19.25

... More
Fixing of Top hamper with clamps on erected support as per design. The nuts & bolts will be supplied by the contractor as per Nigam's specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV Top hamper

-

-

-

... More
11 KV Top hamper

5

37

7.44

... More
Fixing and assembly of disc point channel pair with pilot plates top hampers & clampson erected single pole structure as per design. The nuts & bolts will be supplied by the contractor as per Nigam's specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV line

-

-

-

... More
Dismental of 11 KV line

10

356

35.62

... More
Fixing of 11 KV B&S/T&C disc insulator for 11 KV line (each unit consisting of 2 nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.

-

-

-

... More
Removal of 11 KV B&S/T&C disc insulator for 11 KV line (each unit consisting of 2 nos. disc & 1 set of H/W)

60

1210

20.17

... More
Fixing of 11 KV pin insulator with pin.

-

-

-

... More
Removal of 11 KV pin insulator with pin.

15

89

5.95

... More
Laying, jointing , stringing, tenstioning and clamping of conductor with proper sage as directed, using bolted type hardware including binding on pin insulators, jumpring on section point with binding wire / P.G. clamps aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging. The contractor will be provide P.G. clamps for which payment will be made as per prevailling Discom issue rate.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
ACSR DOG Conductor

-

-

-

... More
Dismentling of ACSR DOG Conductor

0.75

1093

1457.51

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works) The relays will be tested by Discom.

-

-

-

... More
33 KV VCB / SF - 6 Breaker

-

-

-

... More
11 KV VCB ( Outdoor )

-

-

-

... More
Removal of 33 KV VCB / SF - 6 Breaker

1

3008

3008.37

... More
Removal of 11 KV VCB ( Outdoor )

6

18050

3008.37

... More
Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning lests before energization & satisfactory operation in all respect ( The CT/PT set will be tested by Discom).

-

-

-

... More
11 KV CT ( 1set of 3 Nos.) OR PT Set

-

-

-

... More
Removal of 11 KV CT ( 1set of 3 Nos.) OR PT Set

5

3710

742.12

... More
Installation of metering point on 11 KV outgoing feeder at 33/11 KV S/S

-

-

-

... More
Removal of metering point on 11 KV outgoing feeder at 33/11 KV S/S

5

59326

11865.23

... More
Laying of 11 KV ,XLPE, Cable (Al. conductor ) underground as per relevant IS/JVVNL stanards including excavation of 30 cm witdth x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand.'A' class bricks or concrete block covering refilling soil in the remaining ( Including fixing of G.I. Pipe of required size at both end with 3 Mtr projected above the ground surface & 0.3 Mtr. below ground level)

-

-

-

... More
3x35 Sq mm to 3x185 Sq mm

-

-

-

... More
Note :- Per mtr. Rate shall be paid extra for excavation of puccka road.

-

-

-

... More
Removal of 3x35 Sq mm to 3x185 Sq mm

800

45872

57.34

... More
Note :- Per mtr. Rate shall be paid extra for excavation of puccka road.

800

24200

30.25

... More
MS Nuts & Bolts

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.