If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 33,000Document Cost
₹ 590Tender Fee
₹ 500
Summary
Levelling, Gravelling, Earth Filling In Extended Yard, Const. Of Approach Road And Other Misc Civil Works At 33 Kv S/s Baghoda
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JVVNL_436289_11Bid Award Id
ViewTender No
SE/CIVIL/JVVNL/NIT 19/2024-25Tender Authority
Jaipur Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(B-144/12.37.3)
Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only)
510
4
2040
... More
(B-144/12.37.1)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping andpriming coat with cement primer.
335
75
25125
... More
(B-145/12.42)
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).
170
86
14620
... More
(B-142/12.22.1)
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete.
(A) New Plastered Surface (three or more coats)
510
84
42840
... More
(B-146/12.46.1)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
(B) One or more coats on old work.
80
34
2720
... More
(B-145/12.41.2)
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: Old work (One or more coats).
1140
20
22800
... More
(B-/9.39)
P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge.
4
3895
15580
... More
(B-150/13.4.1)
Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm
5
617
3085
... More
9.26
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
5
617
3085
... More
(B-15.29)
Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:
Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.
109
526
57334
... More
(B-109/10.22)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
51
111
5661
... More
(B-140/12.7)
Finishing with neat cement (punning).
70
36
2520
... More
9.8
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.
150
96
14400
... More
9.8.1
(A) Extra if square,rectangular hollow tubelar sections are used or grill made by flats only
115
9
1104
... More
9.2
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
125
81
10125
... More
9.3.1
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.
60
100
6000
... More
17.1
Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding.
12
689
8268
... More
(B- /13.12)
Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
80
318
25440
... More
(B-44/1.8) Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter All kinds of soils.
12
178
2136
... More
(B-54/3.1.6)
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
56
3302
184912
... More
(B) "M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)." (3.1.2)
2
4624
9248
... More
(B-69/6.1.6)
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
19
2838
53922
... More
(B-56/3.8)
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
16
367
5872
... More
(B-103/9.36.1)
Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron rovided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.
50mm x 50mm x 3.15mm
65
629
40885
... More
11.38.3(A)
Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)
M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc.
Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004
485
1089
528165
... More
7.52
Providing and fixing machine pressed cement concrete (M-20) compressed with hydraulic compression machine kerbs or dands of size upto 60cm length as per drawing, jointing with cement mortar (1:3) over 20 mm thick base cement mortar (1:6) & painting the exposed surface with enamel paint of approved brand complete work as per direction of Engineer in charge size 15 cm x 38 cm.
155
303
46965
... More
(R-34/7.16.2.5)
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of high intensity grade sheeting exclusive of lettering, border and signs fixed over aluminium sheeting, 2mm thick fixed on a mild steel angle iron frame 50mmx50mmx6mm supported on mild steel angle iron post 75x75x6mm upto the top of sign board, length of post from bottom of sign board is 2.85m upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cmx45cmx60cm, 60cm below ground level as per approved drawing and as per MORTH specifications clause 801 Double angle post 120cm x 90cm
1
9614
9614
... More
B-1.31
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
2500
5
12500
... More
(E-95/18.12.6)
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .LLED Street Light fixture with Minimum lumen output 11225 lm
2
6765
13530
... More
(E-96/18.18.3)
PProviding & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 32 mm Dia. (E-96/18.18.3)
2
742
1484
... More
(E-56/11.2.1.1)
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4.0sqmm 2core.
50
109
5450