Jaipur Vidyut Vitran Nigam Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2025
Closing Soon27 Feb 2025
Tender Amount₹ 5,21,409 
Notes
Download

Costs

  • EMD

    ₹ 10,428
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Summary

Electric Work Under Tn-96

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BID SUBMISSION DATE - 17/02/2025, BID LAST DATE - 27/02/2025 AND BID OPENING DATE - 28/02/2025.
PRICE BID DOCUMENTS.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
9 Mtr/ 1.2mx0.6mx1.50 m deep

40

102

4091.6

... More
Levelling of ground

-

-

-

... More
Levelling of ground up to 30 cm.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)

3000

1

4530

... More
Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms liftup to 1.5 meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.

-

-

-

... More
Hard /dense soil

72

77

5546.88

... More
Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken) in foundation plinth excluding the cost of shuttering using 1 cement : 5 sand : 10 aggregate mix. Note : 1. The rates are all lead of cement, lime, ballast, sand, surkhi and grit etc. at site of work. 2. For all concrete work coarse sand shall be used no extra will be paid . 3. Concrete mix prepared by power driven mechanical mixer shall be used . 4. Under exceptional coditions, where mechanical mixer and vibrator are not used (with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator. 5. Thickness of the cement concrete should not exceeed 100 mm.

5.47

2371

12970.41

... More
Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.

26.39

128

3386.36

-

-

-

... More
The rates for complete work including racking of joints,curing,grinding,mixing and finishing T&P and scaffolding material and cost of material with all lead and lift.

-

-

-

... More
The rates cover protection of all place and things,requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.

-

-

-

... More
Masonry for foundation and plinth

-

-

-

... More
Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.

24.38

1924

46927.36

... More
Safe carriage of PCC poles including loading / un-loading

-

-

-

... More
a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole

-

-

-

... More
Within 10 Kms.

16

231

3707.84

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.@4.75/km

16

95

1520

... More
c) 9 Mtr.long 200 Kg. PCC pole

-

-

-

... More
within 10 Kms.-

24

194

4667.04

... More
Above 10 Km. & upto 30 Km. add for each Km. or part thereof @4.75/km

24

95

2280

... More
Safe carriage of steel (fabricated and unfabricated) I.e. M.S. Rails, R.S. Joists, M.S. Channels, M.S. Angles, M.S. Flat, G.I. Stay Sets, G.I. Stay Wire, G.I. Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site.

-

-

-

... More
Within 10 Kms.

5.2

325

1693.38

... More
Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
Within 10 Kms.

7.9

390

3083.29

... More
Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading from store to site (these Charges will be 1.5 times for both sides)

-

-

-

... More
b) 25 & 40 KVA

-

-

-

... More
Within 10 Kms.

1

238

238.51

... More
Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores

-

-

-

... More
Within 10 KMs.

4

889

3558.52

... More
Fixing of 11kv B&S / T&C type disc insulator for 33kv lines (each unit consiting of 3 nos. disc & 1set of H/W) on terminal point including fixing of hardware and strips.

50

46

2348

... More
Fixing of 33kv pin insulator with pins.

12

14

178.44

... More
Fixing of 11kv pin insulator with pins.

12

9

119.04

... More
Assembly, Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories complete in all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(B)G.O. switch . without earthing blade.

-

-

-

... More
33kv G.O.switch

2

1112

2224.58

... More
11kv G.O.switch

6

865

5190.6

... More
11 KV SFU (three phase)

1

963

963.97

... More
Installation of lightening arrestors on erected structure /support (1 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(A)sub-station type

-

-

-

... More
33 KV L.A. each

3

170

512.85

... More
Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33kv Horn Gap fuse set.

1

512

512.84

... More
11kv Horn Gap fuse set.

5

444

2224.8

... More
Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
25 and 40 KVA

1

621

621.01

... More
Fixing of danger plates on supports/structure

8

7

59.44

... More
Fixing of PG clamp of Panther Conductor

80

7

632.8

... More
Laying of 1100 volt heavy duty armoured XLPE cable of aluminum coudctor of following size conforming to IS: 7098 (Pt-I) (latest amended) overhead service line from pole to meter terminals for release of new LT connections/replacement of damaged/obsolete service line (except agriculture one). The cable must be fixed on wall with clamps /hooks properly at a interval of one meter.

-

-

-

... More
4 Core 16/25 sq. mm

50

8

413

... More
Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
ACSR DOG/RABBIT

500

23

11735

... More
Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:

-

-

-

... More
Excavation of trench of 0.65 Mtrs.depth and 0.5 Mtr.width

-

-

-

... More
Hard Soil

105

152

16029.3

... More
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

440

25

11321.2

... More
Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

440

38

17045.6

... More
Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:

-

-

-

... More
Where drilling is not required

30

190

5709.3

... More
Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.

215

5

1100.8

... More
Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

250

7

1782.5

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
11 KV VCB (Indoor )

4

4062

16251.88

... More
Installation of control panel including checking of wiring and conducting all pre-commissioning tests before energization, satisfactory operation of all equipment existing thereof. ( The relay will be tested by Discom ).

-

-

-

... More
Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (The CT/PT set will be tested by Discom).

-

-

-

... More
33 KV CT(1 set of 3 Nos. ) OR PT Set

3

1236

3710.64

... More
Installation of metering points on 11 KV Out going feeder at 33/11 KV S/S.

3

19775

59326.17

... More
The installation work to be carried out as per drawing/design, under the supervision of concerned Assistant Engineer

-

-

-

... More
Mounting structure

-

-

-

... More
The requisite steel members will be supplied by contractor including the hardware. Contractor shall joint/weld the members to form the mounting structure as per drawing. Necessary tools, welding, machines, lifting devices etc. shall be arranged by contractor.

-

-

-

... More
Civil works

-

-

-

... More
Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.

-

-

-

... More
Metering Equipments:

-

-

-

... More
The requisite metering equipments (CTPT set, meter,meter box & suitable conductors for jumpers), will be provided by the concerned Assistant Engineer in healthy condition at site. The cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.

-

-

-

... More
Meter:

-

-

-

... More
Meters should be fixed firmly inside the tamper proof box, as per drawing. All the meter fixture will be provided by contractor including all consumables.

-

-

-

... More
Meter Box

-

-

-

... More
The meter box shall be provided by the concerned Assistant Engineer. However, hardware or any other items required to fix the meter inside the meter box will be provided by contractor. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box.

-

-

-

... More
Painting:

-

-

-

... More
All surfaces interior and exterior of lattice structure shall be white aluminum painted.

-

-

-

... More
Commissioning of Metering Equipments:

-

-

-

... More
Installed meters inside the box and metering equipments duly mounted on the mounting structure will be powered up by connecting load in the presence of the concerned Assistant Engineer who will arrange the necessary shut down. The completion certificate shall be furnised by contractor.be filled accordingly. Since the work involves higher A.C. voltage level, the contractor shall take full care regarding safety norms, so as to avoid any accidental hazards.

-

-

-

... More
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
On new surface

500

32

16235

... More
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
On new works with two coats.

500

48

24350

... More
Safe Carriage of 33/11 KV Power Transformer.

-

-

-

... More
C) 5.0 MVA

-

-

-

... More
within 10 Kms.

1

5081

5081.77

... More
Above 10 Kms & upto 30 Kms . Add for each Km or part thereof (5 Km)@50.81/km

1

1016

1016.2

... More
Above 30 Kms & upto 50 Kms . Add for each Km or part thereof (20 Km)@33.61/km

1

672

672.2

... More
Above 50 Kms and upto 75 Kms Add for each Km or part thereof (25 Km)@16.27/km

1

406

406.75

... More
Safe loading of power/ distribution transformer.

-

-

-

... More
(A) 33/11 KV power transformer.

-

-

-

2

5035

10071.34

... More
Safe unloading of steel fabricated/ unfabricated conductor drum & other line material.

-

-

-

... More
Safe unloading of power/distribution transformers

-

-

-

... More
a) 33/11 KV power transformer.

-

-

-

... More
Above 3.15 MVA

1

4265

4265.88

... More
Excavation of pit in ordinary rock which does not require blasting/murrad (in Jodhpur discom) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(B) Lattice Tower /Size of pit

-

-

-

... More
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep

6

1310

7863

... More
(C)Stay set/Depth of pit

-

-

-

... More
8'x 3/4" -0.75x0.5x1.6 m

4

232

929.88

... More
Safe carriage of steel (fabricated and unfabricated) I.e. M.S. Rails, R.S. Joists, M.S. Channels, M.S. Angles, M.S. Flat, G.I. Stay Sets, G.I. Stay Wire, G.I. Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site.

-

-

-

... More
Within 10 Kms.

0.5

325

162.83

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.@4.61/km

0.5

92

46.1

... More
Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
Within 10 Kms.

0.5

390

195.15

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.@5.57/km

0.5

111

55.7

... More
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.

-

-

-

... More
Within 10 Kms.

3

474

1424.13

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof@4.61/km.

3

92

276.6

... More
Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.

-

-

-

... More
Lattice Structure

3

4888

14665.59

... More
Trimming of tree branches/plants manually/by machine and preparing route approchase for proposed line

150

29

4497

... More
Erection & fixing of G.I. Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set/stay wire

-

-

-

... More
8"x3/4" with 7/8 SWG stay wire

4

278

1115.24

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.

21

2823

59301.69

... More
Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33 KV line

1

135

135.91

... More
Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 Nos. disc.& 1set of H/W) on terminal point including fixing of hardware and strips.

12

46

563.52

... More
Fixing of 33kv pin insulator with pins.

18

14

267.66

... More
b) Fixing of PG clamp of Dog /Racoon Conductor

6

4

29.82

... More
Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
IN RURAL AREA

-

-

-

... More
ACSR DOG

0.75

2584

1938.23

... More
Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
G.I.Earth wire 6 SWG

0.25

894

223.56

... More
Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod 20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

6

335

2011.32

... More
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
On new surface

534

32

17338.98

... More
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
On new works with two coats.

534

48

26005.8

... More
Drilling of holes in MS Channel / Angle /Flat

-

-

-

... More
15/16" dia holes(23.81 mm dia.)

90

6

584.1

... More
Excavation of pit in ordinary rock which does not require blasting/murrad (in Jodhpur discom) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
A)Height of poles/R.S.Joist/M.S. Rail /Size of pit

-

-

-

... More
9 Mtr/ 1.2mx0.6mx1.50 m deep

38

255

9717.36

... More
(C)Stay set/Depth of pit

-

-

-

... More
6'x 5/8" -0.75x0.5x1.35 m

18

209

3765.78

... More
Safe carriage of PCC poles including loading / un-loading

-

-

-

... More
(C) 9 Mtr.long 200 Kg. PCC pole

-

-

-

... More
Within 10 Kms.

38

194

7389.48

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.@4.75/km

38

95

3610

... More
Safe carriage of steel (fabricated and unfabricated) I.e. M.S. Rails, R.S. Joists, M.S. Channels, M.S. Angles, M.S. Flat, G.I. Stay Sets, G.I. Stay Wire, G.I. Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site.

-

-

-

... More
Within 10 Kms.

1.5

325

488.47

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. @4.61/km

1.5

92

138.3

... More
Safe Carriage of insulator, hardware, cable etc. including loading / unloading and stacking in Nigam stores etc.

-

-

-

... More
Within 10 Kms.

1

390

390.29

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof @5.57/km.

1

111

111.4

... More
Trimming of tree branches/plants manually/by machine and preparing route approchase for proposed line

150

29

4497

... More
Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
PCC Poles 9 Mtr. Long(200Kg.)

32

378

12125.76

... More
Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long (200 Kg.)

3

1105

3315

... More
Erection & fixing of G.I. Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set/stay wire

-

-

-

... More
6"x5/8" with 7/10 SWG stay wire

18

241

4343.58

... More
Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV line

3

91

274.29

... More
Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 1 Nos. disc & 1 set of H/W ) on terminal point including fixing of hardware and strips.

36

22

803.16

... More
Fixing of 11kv pin insulator with pins.

96

9

952.32

... More
Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
IN RURAL AREA

-

-

-

... More
ACSR RABBIT

3.36

2205

7412.09

... More
Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod 20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

5

335

1676.1

... More
Drilling of holes in MS Channel / Angle /Flat

-

-

-

... More
15/16" dia holes(23.81 mm dia.)

50

6

324.5

... More
13/16" dia holes(20.63 mm dia.)

30

4

128.4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.